Pelin Aksit Ciris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pelin Aksit Ciris has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Robert Todd Constable
Interdepartmental Neuroscience Program, Yale School of Medicine, New Haven, USA
3 shared publications Clare M. Tempany‐Afdhal
Harvard Medical School, Boston, MA, USA
2 shared publicationsMaolin Qiu
Department of Diagnostic Radiology Yale University, School of Medicine, Magnetic Resonance Research Center New Haven Connecticut USA
2 shared publicationsMukund Balasubramanian
Harvard Medical School, Boston, MA, USA
2 shared publicationsRavi T. Seethamraju
Siemens Healthcare, Boston, MA, USA
2 shared publicationsRobert V. Mulkern
Harvard Medical School, Boston, MA, USA
2 shared publications
Latest Publications
- 11 January 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (3) , 962-963
Editorial for “Assessment of Cerebrovascular Reactivity UsingCO2‐BOLD MRI: A 15‐Year, Single Center Experience”
- 11 January 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (3) , 962-963
Editorial for “Assessment of Cerebrovascular Reactivity UsingCO2‐BOLD MRI: A 15‐Year, Single Center Experience”
- 4 August 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 36 (1) , 119-133
Information theoretic evaluation of Lorentzian, Gaussian, Voigt, and symmetric alpha-stable models of reversible transverse relaxation in cervical cancer in vivo at 3 T
Objects To better characterize cervical cancer at 3 T. MRI transverse relaxation patterns hold valuable biophysical information about cellular scale microstructure. Lorentzian modeling is typically used to represent intravoxel frequency distributions, resulting in mono-exponential decay of reversible transverse relaxation. However, deviations from mono-exponential decay are expected theoretically and observed experimentally. Materials and methods We compared the information content of four models of signal attenuation with reversible transverse relaxation. Biological phantoms and six women with cervical squamous cell carcinoma were imaged using a gradient-echo sampling of the spin-echo (GESSE) sequence. Lorentzian, Gaussian, Voigt, and Symmetric α-Stable (SAS) models were ranked using Akaike’s Information Criterion (AIC), and the model retaining the highest information content was identified at each voxel as the best model. Results The Lorentzian model resulted in information loss in large fractions of the phantoms and cervix. Gaussian and SAS models frequently had higher information content than the Lorentzian in much of the areas of interest. The Voigt model rarely surpassed the three other models in terms of information content. Discussion Gaussian and SAS models provide better fitting of data in much of the human cervix at 3 T. Minimizing information loss through improved tissue modeling may have important implications for identifying reliable biomarkers of tumor hypoxia and iron deposition.
- 4 August 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 36 (1) , 119-133
Information theoretic evaluation of Lorentzian, Gaussian, Voigt, and symmetric alpha-stable models of reversible transverse relaxation in cervical cancer in vivo at 3 T
Objects To better characterize cervical cancer at 3 T. MRI transverse relaxation patterns hold valuable biophysical information about cellular scale microstructure. Lorentzian modeling is typically used to represent intravoxel frequency distributions, resulting in mono-exponential decay of reversible transverse relaxation. However, deviations from mono-exponential decay are expected theoretically and observed experimentally. Materials and methods We compared the information content of four models of signal attenuation with reversible transverse relaxation. Biological phantoms and six women with cervical squamous cell carcinoma were imaged using a gradient-echo sampling of the spin-echo (GESSE) sequence. Lorentzian, Gaussian, Voigt, and Symmetric α-Stable (SAS) models were ranked using Akaike’s Information Criterion (AIC), and the model retaining the highest information content was identified at each voxel as the best model. Results The Lorentzian model resulted in information loss in large fractions of the phantoms and cervix. Gaussian and SAS models frequently had higher information content than the Lorentzian in much of the areas of interest. The Voigt model rarely surpassed the three other models in terms of information content. Discussion Gaussian and SAS models provide better fitting of data in much of the human cervix at 3 T. Minimizing information loss through improved tissue modeling may have important implications for identifying reliable biomarkers of tumor hypoxia and iron deposition.
- Open Access
- 1 January 2017
- Published by Elsevier in NeuroImage: Clinical
- Vol. 13, 138-153
Automated white matter fiber tract identification in patients with brain tumors
- 1 January 2017
- Published by Elsevier in NeuroImage: Clinical
- Vol. 13, 138-153
Open AccessAutomated white matter fiber tract identification in patients with brain tumors
- 31 May 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 29 (7) , 999-1009
Characterization of gradient echo signal decays in healthy and cancerous prostate at 3T improves with a Gaussian augmentation of the mono‐exponential (GAME) model
A biomarker of cancer aggressiveness, such as hypoxia, could substantially impact treatment decisions in the prostate, especially radiation therapy, by balancing treatment morbidity (urinary incontinence, erectile dysfunction, etc.) against mortality. R2* mapping with Mono‐Exponential (ME) decay modeling has shown potential for identifying areas of prostate cancer hypoxia at 1.5T. However, Gaussian deviations from ME decay have been observed in other tissues at 3T. The purpose of this study is to assess whether gradient‐echo signal decays are better characterized by a standard ME decay model, or a Gaussian Augmentation of the Mono‐Exponential (GAME) decay model, in the prostate at 3T. Multi‐gradient‐echo signals were acquired on 20 consecutive patients with a clinical suspicion of prostate cancer undergoing MR‐guided prostate biopsies. Data were fitted with both ME and GAME models. The information contents of these models were compared using Akaike's information criterion (second order, AICC), in skeletal muscle, the prostate central gland (CG), and peripheral zone (PZ) regions of interest (ROIs). The GAME model had higher information content in 30% of the prostate on average (across all patients and ROIs), covering up to 67% of cancerous PZ ROIs, and up to 100% of cancerous CG ROIs (in individual patients). The higher information content of GAME became more prominent in regions that would be assumed hypoxic using ME alone, reaching 50% of the PZ and 70% of the CG as ME R2* approached 40 s−1. R2* mapping may have important applications in MRI; however, information lost due to modeling could mask differences in parameters due to underlying tissue anatomy or physiology. The GAME model improves characterization of signal behavior in the prostate at 3T, and may increase the potential for determining correlates of fit parameters with biomarkers, for example of oxygenation status.
- 31 May 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 29 (7) , 999-1009
Characterization of gradient echo signal decays in healthy and cancerous prostate at 3T improves with a Gaussian augmentation of the mono‐exponential (GAME) model
A biomarker of cancer aggressiveness, such as hypoxia, could substantially impact treatment decisions in the prostate, especially radiation therapy, by balancing treatment morbidity (urinary incontinence, erectile dysfunction, etc.) against mortality. R2* mapping with Mono‐Exponential (ME) decay modeling has shown potential for identifying areas of prostate cancer hypoxia at 1.5T. However, Gaussian deviations from ME decay have been observed in other tissues at 3T. The purpose of this study is to assess whether gradient‐echo signal decays are better characterized by a standard ME decay model, or a Gaussian Augmentation of the Mono‐Exponential (GAME) decay model, in the prostate at 3T. Multi‐gradient‐echo signals were acquired on 20 consecutive patients with a clinical suspicion of prostate cancer undergoing MR‐guided prostate biopsies. Data were fitted with both ME and GAME models. The information contents of these models were compared using Akaike's information criterion (second order, AICC), in skeletal muscle, the prostate central gland (CG), and peripheral zone (PZ) regions of interest (ROIs). The GAME model had higher information content in 30% of the prostate on average (across all patients and ROIs), covering up to 67% of cancerous PZ ROIs, and up to 100% of cancerous CG ROIs (in individual patients). The higher information content of GAME became more prominent in regions that would be assumed hypoxic using ME alone, reaching 50% of the PZ and 70% of the CG as ME R2* approached 40 s−1. R2* mapping may have important applications in MRI; however, information lost due to modeling could mask differences in parameters due to underlying tissue anatomy or physiology. The GAME model improves characterization of signal behavior in the prostate at 3T, and may increase the potential for determining correlates of fit parameters with biomarkers, for example of oxygenation status.
- 12 March 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (4) , 1020-1030
Characterizing gradient echo signal decays in gynecologic cancers at 3T using a Gaussian augmentation of the monoexponential (GAME) model
Purpose: To assess whether mapping with a standard Monoexponential (ME) or a Gaussian Augmentation of the Monoexponential (GAME) decay model better characterizes gradient‐echo signal decays in gynecological cancers after external beam radiation therapy at 3T, and evaluate implications of modeling for noninvasive identification of intratumoral hypoxia.Materials and Methods: Multi‐gradient‐echo signals were acquired on 25 consecutive patients with gynecologic cancers and three healthy participants during inhalation of different oxygen concentrations at 3T. Data were fitted with both ME and GAME models. Models were compared using F‐tests in tumors and muscles in patients, muscles, cervix, and uterus in healthy participants, and across oxygenation levels.Results: GAME significantly improved fitting over ME (P < 0.05): Improvements with GAME covered 34% of tumor regions‐of‐interest on average, ranging from 6% (of a vaginal tumor) to 68% (of a cervical tumor) in individual tumors. Improvements with GAME were more prominent in areas that would be assumed hypoxic based on ME alone, reaching 90% as ME approached 100 Hz. Gradient echo decay parameters at different oxygenation levels were not significantly different (P = 0.81).Conclusion: may prove sensitive to hypoxia; however, inaccurate representations of underlying data may limit the success of quantitative assessments. Although the degree to which R2 or σ values correlate with hypoxia remains unknown, improved characterization with GAME increases the potential for determining any correlates of fit parameters with biomarkers, such as oxygenation status. J. MAGN. RESON. IMAGING 2016;44:1020–1030.
- 12 March 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (4) , 1020-1030
Characterizing gradient echo signal decays in gynecologic cancers at 3T using a Gaussian augmentation of the monoexponential (GAME) model
Purpose: To assess whether mapping with a standard Monoexponential (ME) or a Gaussian Augmentation of the Monoexponential (GAME) decay model better characterizes gradient‐echo signal decays in gynecological cancers after external beam radiation therapy at 3T, and evaluate implications of modeling for noninvasive identification of intratumoral hypoxia.Materials and Methods: Multi‐gradient‐echo signals were acquired on 25 consecutive patients with gynecologic cancers and three healthy participants during inhalation of different oxygen concentrations at 3T. Data were fitted with both ME and GAME models. Models were compared using F‐tests in tumors and muscles in patients, muscles, cervix, and uterus in healthy participants, and across oxygenation levels.Results: GAME significantly improved fitting over ME (P < 0.05): Improvements with GAME covered 34% of tumor regions‐of‐interest on average, ranging from 6% (of a vaginal tumor) to 68% (of a cervical tumor) in individual tumors. Improvements with GAME were more prominent in areas that would be assumed hypoxic based on ME alone, reaching 90% as ME approached 100 Hz. Gradient echo decay parameters at different oxygenation levels were not significantly different (P = 0.81).Conclusion: may prove sensitive to hypoxia; however, inaccurate representations of underlying data may limit the success of quantitative assessments. Although the degree to which R2 or σ values correlate with hypoxia remains unknown, improved characterization with GAME increases the potential for determining any correlates of fit parameters with biomarkers, such as oxygenation status. J. MAGN. RESON. IMAGING 2016;44:1020–1030.
- 10 March 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (3) , 1193-1200
Dual‐Pathway sequences for MR thermometry: When and where to use them
Purpose: Dual‐pathway sequences have been proposed to help improve the temperature‐to‐noise ratio (TNR) in MR thermometry. The present work establishes how much of an improvement these so‐called “PSIF‐FISP” sequences may bring in various organs and tissues.Methods: Simulations and TNR calculations were validated against analytical equations, phantom, abdomen, and brain scans. Relative TNRs for PSIF‐FISP, as compared to a dual‐FISP reference standard, were calculated for flip angle (FA) = 1 to 85 º and repetition time (TR) = 6 to 60 ms, for gray matter, white matter, cervix, endometrium, myometrium, prostate, kidney medulla and cortex, bone marrow, pancreas, spleen, muscle, and liver tissues.Results: PSIF‐FISP was TNR superior in the kidney, pelvis, spleen, or gray matter at most tested TR and FA settings, and benefits increased at shorter TRs. PSIF‐FISP was TNR superior in other tissues, e.g., liver, muscle, pancreas, for only short TR settings (20 ms or less). The TNR benefits of PSIF‐FISP increased slightly with FA, and strongly with decreasing TR. Up to two‐ to three‐fold reductions in TR with 20% TNR gains were achievable. In any given tissue, TNR performance is expected to further improve with heating, due to changes in relaxation rates.Conclusion: Dual‐pathway PSIF‐FISP can improve TNR and acquisition speed over standard gradient‐recalled echo sequences, but optimal acquisition parameters are tissue dependent. Magn Reson Med 77:1193–1200, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- 10 March 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (3) , 1193-1200
Dual‐Pathway sequences for MR thermometry: When and where to use them
Purpose: Dual‐pathway sequences have been proposed to help improve the temperature‐to‐noise ratio (TNR) in MR thermometry. The present work establishes how much of an improvement these so‐called “PSIF‐FISP” sequences may bring in various organs and tissues.Methods: Simulations and TNR calculations were validated against analytical equations, phantom, abdomen, and brain scans. Relative TNRs for PSIF‐FISP, as compared to a dual‐FISP reference standard, were calculated for flip angle (FA) = 1 to 85 º and repetition time (TR) = 6 to 60 ms, for gray matter, white matter, cervix, endometrium, myometrium, prostate, kidney medulla and cortex, bone marrow, pancreas, spleen, muscle, and liver tissues.Results: PSIF‐FISP was TNR superior in the kidney, pelvis, spleen, or gray matter at most tested TR and FA settings, and benefits increased at shorter TRs. PSIF‐FISP was TNR superior in other tissues, e.g., liver, muscle, pancreas, for only short TR settings (20 ms or less). The TNR benefits of PSIF‐FISP increased slightly with FA, and strongly with decreasing TR. Up to two‐ to three‐fold reductions in TR with 20% TNR gains were achievable. In any given tissue, TNR performance is expected to further improve with heating, due to changes in relaxation rates.Conclusion: Dual‐pathway PSIF‐FISP can improve TNR and acquisition speed over standard gradient‐recalled echo sequences, but optimal acquisition parameters are tissue dependent. Magn Reson Med 77:1193–1200, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- Open Access
- 21 October 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (3) , 864-875
Noninvasive MRI measurement of the absolute cerebral blood volume–cerebral blood flow relationship during visual stimulation in healthy humans
Purpose: The relationship between cerebral blood volume (CBV) and cerebral blood flow (CBF) underlies blood oxygenation level–dependent functional MRI signal. This study investigates the potential for improved characterization of the CBV‐CBF relationship in humans, and examines sex effects as well as spatial variations in the CBV‐CBF relationship.Methods: Healthy subjects were imaged noninvasively at rest and during visual stimulation, constituting the first MRI measurement of the absolute CBV‐CBF relationship in humans with complete coverage of the functional areas of interest.Results: CBV and CBF estimates were consistent with the literature, and their relationship varied both spatially and with sex. In a region of interest with stimulus‐induced activation in CBV and CBF at a significance level of the P < 0.05, a power function fit resulted in CBV = 2.1 CBF0.32 across all subjects, CBV = 0.8 CBF0.51 in females and CBV = 4.4 CBF0.15 in males. Exponents decreased in both sexes as ROIs were expanded to include less significantly activated regions.Conclusion: Consideration for potential sex‐related differences, as well as regional variations under a range of physiological states, may reconcile some of the variation across literature and advance our understanding of the underlying cerebrovascular physiology. Magn Reson Med 72:864–875, 2014.
- 21 October 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (3) , 864-875
Open AccessNoninvasive MRI measurement of the absolute cerebral blood volume–cerebral blood flow relationship during visual stimulation in healthy humans
Purpose: The relationship between cerebral blood volume (CBV) and cerebral blood flow (CBF) underlies blood oxygenation level–dependent functional MRI signal. This study investigates the potential for improved characterization of the CBV‐CBF relationship in humans, and examines sex effects as well as spatial variations in the CBV‐CBF relationship.Methods: Healthy subjects were imaged noninvasively at rest and during visual stimulation, constituting the first MRI measurement of the absolute CBV‐CBF relationship in humans with complete coverage of the functional areas of interest.Results: CBV and CBF estimates were consistent with the literature, and their relationship varied both spatially and with sex. In a region of interest with stimulus‐induced activation in CBV and CBF at a significance level of the P < 0.05, a power function fit resulted in CBV = 2.1 CBF0.32 across all subjects, CBV = 0.8 CBF0.51 in females and CBV = 4.4 CBF0.15 in males. Exponents decreased in both sexes as ROIs were expanded to include less significantly activated regions.Conclusion: Consideration for potential sex‐related differences, as well as regional variations under a range of physiological states, may reconcile some of the variation across literature and advance our understanding of the underlying cerebrovascular physiology. Magn Reson Med 72:864–875, 2014.
- Open Access
- 6 September 2013
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (1) , 133-141
Navigated DENSE strain imaging for post-radiofrequency ablation lesion assessment in the swine left atria
Prior work has demonstrated that magnetic resonance imaging (MRI) strain can separate necrotic/stunned myocardium from healthy myocardium in the left ventricle (LV). We surmised that high-resolution MRI strain, using navigator-echo-triggered DENSE, could differentiate radiofrequency ablated tissue around the pulmonary vein (PV) from tissue that had not been damaged by radiofrequency energy, similarly to navigated 3D myocardial delayed enhancement (3D-MDE). A respiratory-navigated 2D-DENSE sequence was developed, providing strain encoding in two spatial directions with 1.2 × 1.0 × 4 mm3 resolution. It was tested in the LV of infarcted sheep. In four swine, incomplete circumferential lesions were created around the right superior pulmonary vein (RSPV) using ablation catheters, recorded with electro-anatomic mapping, and imaged 1 h later using atrial-diastolic DENSE and 3D-MDE at the left atrium/RSPV junction. DENSE detected ablation gaps (regions with >12% strain) in similar positions to 3D-MDE (2D cross-correlation 0.89 ± 0.05). Low-strain (<8%) areas were, on average, 33% larger than equivalent MDE regions, so they include both injured and necrotic regions. Optimal DENSE orientation was perpendicular to the PV trunk, with high shear strain in adjacent viable tissue appearing as a sensitive marker of ablation lesions. Magnetic resonance imaging strain may be a non-contrast alternative to 3D-MDE in intra-procedural monitoring of atrial ablation lesions.
- 6 September 2013
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (1) , 133-141
Open AccessNavigated DENSE strain imaging for post-radiofrequency ablation lesion assessment in the swine left atria
Prior work has demonstrated that magnetic resonance imaging (MRI) strain can separate necrotic/stunned myocardium from healthy myocardium in the left ventricle (LV). We surmised that high-resolution MRI strain, using navigator-echo-triggered DENSE, could differentiate radiofrequency ablated tissue around the pulmonary vein (PV) from tissue that had not been damaged by radiofrequency energy, similarly to navigated 3D myocardial delayed enhancement (3D-MDE). A respiratory-navigated 2D-DENSE sequence was developed, providing strain encoding in two spatial directions with 1.2 × 1.0 × 4 mm3 resolution. It was tested in the LV of infarcted sheep. In four swine, incomplete circumferential lesions were created around the right superior pulmonary vein (RSPV) using ablation catheters, recorded with electro-anatomic mapping, and imaged 1 h later using atrial-diastolic DENSE and 3D-MDE at the left atrium/RSPV junction. DENSE detected ablation gaps (regions with >12% strain) in similar positions to 3D-MDE (2D cross-correlation 0.89 ± 0.05). Low-strain (<8%) areas were, on average, 33% larger than equivalent MDE regions, so they include both injured and necrotic regions. Optimal DENSE orientation was perpendicular to the PV trunk, with high shear strain in adjacent viable tissue appearing as a sensitive marker of ablation lesions. Magnetic resonance imaging strain may be a non-contrast alternative to 3D-MDE in intra-procedural monitoring of atrial ablation lesions.
- Open Access
- 8 March 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (2) , 580-590
Non‐invasive quantification of absolute cerebral blood volume during functional activation applicable to the whole human brain
Purpose Cerebral blood volume (CBV) changes in many diverse pathologic conditions, and in response to functional challenges along with changes in blood flow, blood oxygenation, and the cerebral metabolic rate of oxygen. The feasibility of a new method for non‐invasive quantification of absolute cerebral blood volume that can be applicable to the whole human brain was investigated. Methods Multi‐slice data were acquired at 3 T using a novel inversion recovery echo planar imaging (IR‐EPI) pulse sequence with varying contrast weightings and an efficient rotating slice acquisition order, at rest and during visual activation. A biophysical model was used to estimate absolute cerebral blood volume at rest and during activation, and oxygenation during activation, on data from 13 normal human subjects. Results Cerebral blood volume increased by 21.7% from 6.6 ± 0.8 mL/100 mL of brain parenchyma at rest to 8.0 ± 1.3 mL/100 mL of brain parenchyma in the occipital cortex during visual activation, with average blood oxygenation of 84 ± 2.1% during activation, comparing well with literature. Conclusion The method is feasible, and could foster improved understanding of the fundamental physiological relationship between neuronal activity, hemodynamic changes, and metabolism underlying brain activation; complement existing methods for estimating compartmental changes; and potentially find utility in evaluating vascular health. Magn Reson Med 71:580–590, 2014.
- 8 March 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (2) , 580-590
Open AccessNon‐invasive quantification of absolute cerebral blood volume during functional activation applicable to the whole human brain
Purpose Cerebral blood volume (CBV) changes in many diverse pathologic conditions, and in response to functional challenges along with changes in blood flow, blood oxygenation, and the cerebral metabolic rate of oxygen. The feasibility of a new method for non‐invasive quantification of absolute cerebral blood volume that can be applicable to the whole human brain was investigated. Methods Multi‐slice data were acquired at 3 T using a novel inversion recovery echo planar imaging (IR‐EPI) pulse sequence with varying contrast weightings and an efficient rotating slice acquisition order, at rest and during visual activation. A biophysical model was used to estimate absolute cerebral blood volume at rest and during activation, and oxygenation during activation, on data from 13 normal human subjects. Results Cerebral blood volume increased by 21.7% from 6.6 ± 0.8 mL/100 mL of brain parenchyma at rest to 8.0 ± 1.3 mL/100 mL of brain parenchyma in the occipital cortex during visual activation, with average blood oxygenation of 84 ± 2.1% during activation, comparing well with literature. Conclusion The method is feasible, and could foster improved understanding of the fundamental physiological relationship between neuronal activity, hemodynamic changes, and metabolism underlying brain activation; complement existing methods for estimating compartmental changes; and potentially find utility in evaluating vascular health. Magn Reson Med 71:580–590, 2014.
- Open Access
- 14 May 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 64 (2) , 447-456
O‐space imaging: Highly efficient parallel imaging using second‐order nonlinear fields as encoding gradients with no phase encoding
Recent improvements in parallel imaging have been driven by the use of greater numbers of independent surface coils placed so as to minimize aliasing along the phase‐encode direction(s). However, gains from increasing the number of coils diminish as coil coupling problems begin to dominate and the ratio of acceleration gain to expense for multiple receiver chains becomes prohibitive. In this work, we redesign the spatial‐encoding strategy in order to gain efficiency, achieving a gradient encoding scheme that is complementary to the spatial encoding provided by the receiver coils. This approach leads to “O‐space” imaging, wherein the gradient shapes are tailored to an existing surface coil array, making more efficient use of the spatial information contained in the coil profiles. In its simplest form, for each acquired echo the Z2 spherical harmonic is used to project the object onto sets of concentric rings, while the X and Y gradients are used to offset this projection within the imaging plane. The theory is presented, an algorithm is introduced for image reconstruction, and simulations reveal that O‐space encoding achieves high encoding efficiency compared to sensitivity encoding (SENSE) radial k‐space trajectories, and parallel imaging technique with localized gradients (PatLoc), suggesting that O‐space imaging holds great potential for accelerated scanning. Magn Reson Med, 2010.
- 14 May 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 64 (2) , 447-456
Open AccessO‐space imaging: Highly efficient parallel imaging using second‐order nonlinear fields as encoding gradients with no phase encoding
Recent improvements in parallel imaging have been driven by the use of greater numbers of independent surface coils placed so as to minimize aliasing along the phase‐encode direction(s). However, gains from increasing the number of coils diminish as coil coupling problems begin to dominate and the ratio of acceleration gain to expense for multiple receiver chains becomes prohibitive. In this work, we redesign the spatial‐encoding strategy in order to gain efficiency, achieving a gradient encoding scheme that is complementary to the spatial encoding provided by the receiver coils. This approach leads to “O‐space” imaging, wherein the gradient shapes are tailored to an existing surface coil array, making more efficient use of the spatial information contained in the coil profiles. In its simplest form, for each acquired echo the Z2 spherical harmonic is used to project the object onto sets of concentric rings, while the X and Y gradients are used to offset this projection within the imaging plane. The theory is presented, an algorithm is introduced for image reconstruction, and simulations reveal that O‐space encoding achieves high encoding efficiency compared to sensitivity encoding (SENSE) radial k‐space trajectories, and parallel imaging technique with localized gradients (PatLoc), suggesting that O‐space imaging holds great potential for accelerated scanning. Magn Reson Med, 2010.