David S. Ching
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David S. Ching has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Christopher J. Elkins
Stanford University
3 shared publications- Cosmin Safta
Sandia National Laboratories, Livermore, USA
2 shared publications - John Chilleri
Sandia National Laboratories, Livermore, CA, USA
2 shared publications John K. Eaton
Department of Mechanical Engineering, Stanford University, 488 Escondido Mall, Stanford, CA94305, USA
2 shared publications- John K. Eaton
Department of Mechanical Engineering, Stanford University, Stanford, USA
2 shared publications - Lee Rashkin
Sandia National Laboratories, Albuquerque, NM 87185, USA
2 shared publications
Latest Publications
- Open Access
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 166905-166925
ENCoRP: A Tool to Compute and Visualize an Electrical Network’s Conductive and Radiative Propagation
We present ENCoRP, a tool for computing and visualizing the frequency-domain conductive and radiative propagation associated with an injected signal traversing a user-defined electrical network. Emulating real-world power grids, ENCoRP allows the user to construct an electrical network composed of cables and nodes, with cables containing phase wires and ground/neutral wires and nodes representing various electrical elements, including transmitters, receivers, junction boxes, terminating loads, and shunt loads. ENCoRP is composed of a MATLAB-based graphical user interface that works in conjunction with a Python conductive model and COMSOL Multiphysics® radiative model. The interface may be used to visualize and output the network parameters (ABCD, S, Y, or Z), spatially resolved voltages and currents, or electric and magnetic fields. The underlying models and equations are presented, the numerical limitations are discussed, and the results are verified against Personal Simulation Program with Integrated Circuit Emphasis (PSpice). We conclude with an application of the tool to a hybrid wired-wireless system wherein we examine the electromagnetic fields experienced by a standalone device in the presence of an electrical network.
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 166905-166925
Open AccessENCoRP: A Tool to Compute and Visualize an Electrical Network’s Conductive and Radiative Propagation
We present ENCoRP, a tool for computing and visualizing the frequency-domain conductive and radiative propagation associated with an injected signal traversing a user-defined electrical network. Emulating real-world power grids, ENCoRP allows the user to construct an electrical network composed of cables and nodes, with cables containing phase wires and ground/neutral wires and nodes representing various electrical elements, including transmitters, receivers, junction boxes, terminating loads, and shunt loads. ENCoRP is composed of a MATLAB-based graphical user interface that works in conjunction with a Python conductive model and COMSOL Multiphysics® radiative model. The interface may be used to visualize and output the network parameters (ABCD, S, Y, or Z), spatially resolved voltages and currents, or electric and magnetic fields. The underlying models and equations are presented, the numerical limitations are discussed, and the results are verified against Personal Simulation Program with Integrated Circuit Emphasis (PSpice). We conclude with an application of the tool to a hybrid wired-wireless system wherein we examine the electromagnetic fields experienced by a standalone device in the presence of an electrical network.
- Open Access
Industrial PLC Network Modeling and Parameter Identification Using Sensitivity Analysis and Mean Field Variational Inference
A multiple input multiple output (MIMO) power line communication (PLC) model for industrial facilities was developed that uses the physics of a bottom-up model but can be calibrated like top-down models. The PLC model considers 4-conductor cables (three-phase conductors and a ground conductor) and has several load types, including motor loads. The model is calibrated to data using mean field variational inference with a sensitivity analysis to reduce the parameter space. The results show that the inference method can accurately identify many of the model parameters, and the model is accurate even when the network is modified.
Open AccessIndustrial PLC Network Modeling and Parameter Identification Using Sensitivity Analysis and Mean Field Variational Inference
A multiple input multiple output (MIMO) power line communication (PLC) model for industrial facilities was developed that uses the physics of a bottom-up model but can be calibrated like top-down models. The PLC model considers 4-conductor cables (three-phase conductors and a ground conductor) and has several load types, including motor loads. The model is calibrated to data using mean field variational inference with a sensitivity analysis to reduce the parameter space. The results show that the inference method can accurately identify many of the model parameters, and the model is accurate even when the network is modified.
- Open Access
Sensitivity-Informed Bayesian Inference for Home PLC Network Models with Unknown Parameters
Bayesian inference is used to calibrate a bottom-up home PLC network model with unknown loads and wires at frequencies up to 30 MHz. A network topology with over 50 parameters is calibrated using global sensitivity analysis and transitional Markov Chain Monte Carlo (TMCMC). The sensitivity-informed Bayesian inference computes Sobol indices for each network parameter and applies TMCMC to calibrate the most sensitive parameters for a given network topology. A greedy random search with TMCMC is used to refine the discrete random variables of the network. This results in a model that can accurately compute the transfer function despite noisy training data and a high dimensional parameter space. The model is able to infer some parameters of the network used to produce the training data, and accurately computes the transfer function under extrapolative scenarios.
Open AccessSensitivity-Informed Bayesian Inference for Home PLC Network Models with Unknown Parameters
Bayesian inference is used to calibrate a bottom-up home PLC network model with unknown loads and wires at frequencies up to 30 MHz. A network topology with over 50 parameters is calibrated using global sensitivity analysis and transitional Markov Chain Monte Carlo (TMCMC). The sensitivity-informed Bayesian inference computes Sobol indices for each network parameter and applies TMCMC to calibrate the most sensitive parameters for a given network topology. A greedy random search with TMCMC is used to refine the discrete random variables of the network. This results in a model that can accurately compute the transfer function despite noisy training data and a high dimensional parameter space. The model is able to infer some parameters of the network used to produce the training data, and accurately computes the transfer function under extrapolative scenarios.
- 27 December 2019
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 885
Large-eddy simulation study of unsteady wake dynamics and geometric sensitivity on a skewed bump
Large-eddy simulations of a skewed bump are performed with the bump at angles of bump. The separation bubble and wake oscillate in the spanwise direction. Conditional averaging shows that the vortices are associated with low streamwise velocity and high turbulence. Surface pressures on the bump have negatively skewed distributions in regions on the upstream face and in the separation bubble. In the separation bubble, fluctuations associated with the shedding cycle contribute to the negative skewness.
- 27 December 2019
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 885
Large-eddy simulation study of unsteady wake dynamics and geometric sensitivity on a skewed bump
Large-eddy simulations of a skewed bump are performed with the bump at angles of bump. The separation bubble and wake oscillate in the spanwise direction. Conditional averaging shows that the vortices are associated with low streamwise velocity and high turbulence. Surface pressures on the bump have negatively skewed distributions in regions on the upstream face and in the separation bubble. In the separation bubble, fluctuations associated with the shedding cycle contribute to the negative skewness.
- 4 September 2018
- Published by Springer Nature in Experiments in Fluids
- Vol. 59 (10) , 144
Unsteady vortex structures in the wake of nonaxisymmetric bumps using spiral MRV
- 4 September 2018
- Published by Springer Nature in Experiments in Fluids
- Vol. 59 (10) , 144
Unsteady vortex structures in the wake of nonaxisymmetric bumps using spiral MRV
- 29 August 2018
- Published by Springer Nature in Experiments in Fluids
- Vol. 59 (9) , 1-14
Investigation of geometric sensitivity of a non-axisymmetric bump: 3D mean velocity measurements
- 29 August 2018
- Published by Springer Nature in Experiments in Fluids
- Vol. 59 (9) , 1-14
Investigation of geometric sensitivity of a non-axisymmetric bump: 3D mean velocity measurements
- 17 May 2018
- Published by Springer Nature in Experiments in Fluids
- Vol. 59 (6) , 99
3D Measurements of coupled freestream turbulence and secondary flow effects on film cooling
- 17 May 2018
- Published by Springer Nature in Experiments in Fluids
- Vol. 59 (6) , 99
3D Measurements of coupled freestream turbulence and secondary flow effects on film cooling