David Menard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Menard has a total of 215 co-authors. Here are the top co-authors by number of shared publications:
A. Yelon
Département de Génie Physique & Regroupement Québécois des Matériaux de Pointe, Polytechnique Montréal, Montréal, QC, Canada
39 shared publicationsP. Ciureanu
22 shared publicationsArthur Yelon
Département de génie physique and Regroupement québécois des matériaux de pointe, Polytechnique Montréal, Montréal, QC, Canada
14 shared publicationsLouis-Philippe Carignan
Department of Engineering Physics, Regroupement Québécois sur les Matériaux de Pointe (RQMP), École Polytechnique de Montréal, Montreal, Qc, Canada
14 shared publications- Basile Dufay
UNICAEN, ENSICAEN, CNRS, GREYC, Normandie Universit, Caen, France
12 shared publications - Sébastien Saez
Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen (GREYC), CNRS UMR 6072-ENSICAEN
12 shared publications
Latest Publications
- 31 August 2026
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 656
Isothermal remanent magnetization measurements of oriented MnP nanoparticles embedded in a GaP epilayer
- 31 August 2026
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 656
Isothermal remanent magnetization measurements of oriented MnP nanoparticles embedded in a GaP epilayer
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (22) , 27369-27374
Magneto-Optical Detection of Synthetic Malaria Pigment in Photonic Crystal Fiber
The necessity to develop new technologies for high-sensitivity malaria diagnosis has sparked a global effort in medical and integrative sciences. Most developing procedures rely on research-grade instruments, sophisticated assays, or on expertise. In this work, we propose an alternative optical methodology using a compact and user-friendly apparatus based on a photonic crystal fiber (PCF). Malaria pigment known as hemozoin is an insoluble reddish brown microcrystalline. These crystallites stand out from other blood components in terms of their exceptional magneto-optical features. Consequently, they can function as spinning entities in suspension in response to the external magnetic field. Here synthetic hemozoin (SHz) was obtained in a forthright way with a high yield of 75%. In addition, the prepared sample was characterized morphologically and structurally. The PCF’s nanoholes were filled with the aqueous suspension of SHz with various concentrations and transmitted power recorded in response to the magnetic field. We demonstrate a sensor with a detection threshold of 7.2 parasite/μl well below the level of clinical relevance (50-100 parasite/μl) at a very small liquid sample (less than 0.5 μl). The results of this investigation may provide new light on potential medicinal and sensor applications.
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (22) , 27369-27374
Magneto-Optical Detection of Synthetic Malaria Pigment in Photonic Crystal Fiber
The necessity to develop new technologies for high-sensitivity malaria diagnosis has sparked a global effort in medical and integrative sciences. Most developing procedures rely on research-grade instruments, sophisticated assays, or on expertise. In this work, we propose an alternative optical methodology using a compact and user-friendly apparatus based on a photonic crystal fiber (PCF). Malaria pigment known as hemozoin is an insoluble reddish brown microcrystalline. These crystallites stand out from other blood components in terms of their exceptional magneto-optical features. Consequently, they can function as spinning entities in suspension in response to the external magnetic field. Here synthetic hemozoin (SHz) was obtained in a forthright way with a high yield of 75%. In addition, the prepared sample was characterized morphologically and structurally. The PCF’s nanoholes were filled with the aqueous suspension of SHz with various concentrations and transmitted power recorded in response to the magnetic field. We demonstrate a sensor with a detection threshold of 7.2 parasite/μl well below the level of clinical relevance (50-100 parasite/μl) at a very small liquid sample (less than 0.5 μl). The results of this investigation may provide new light on potential medicinal and sensor applications.
- 1 September 2023
- Published by American Physical Society (APS) in Physical Review B
- Vol. 108 (9) , 094402
Ferromagnetic resonance damping mechanisms in CoFeB thin films with Cr substitution
The substitution of iron atoms by chromium in CoFeB films has been proposed to reduce the critical current density for current-driven magnetization switching in spin transfer torque devices by reducing its magnetization. Yet the effect of Cr on the magnetic damping has remained elusive. Ferromagnetic resonance (FMR) measurements up to 110 GHz and 5 T, as well as angle-dependent FMR measurements at 9.5 and 17 GHz, are used to discriminate between different mechanisms of FMR damping in thin films (, 4, 8, and 18). A constant isotropic Gilbert parameter is used to phenomenologically describe the magnetization damping for each composition, increasing from 0.005 to 0.022 as the amount of Cr increases from 0% to 18%. Two thirds of this contribution appear to be accounted for by intrinsic spin-orbit damping, and the balance is mostly due to extrinsic two-magnon scattering. While the introduction of Cr increases the spin-orbit damping, it nevertheless reduces the corresponding magnetic relaxation rate. The amorphous films with a high scattering rate exhibit a so-called conductivitylike damping at room temperature, in agreement with the breathing Fermi surface model. The presence of Cr also seems to inhibit internal fluctuations of the magnetization, reducing the two-magnon damping. The reduction of due to lower magnetization is partly mitigated by the overall increase in magnetic damping.- 1 September 2023
- Published by American Physical Society (APS) in Physical Review B
- Vol. 108 (9) , 094402
Ferromagnetic resonance damping mechanisms in CoFeB thin films with Cr substitution
The substitution of iron atoms by chromium in CoFeB films has been proposed to reduce the critical current density for current-driven magnetization switching in spin transfer torque devices by reducing its magnetization. Yet the effect of Cr on the magnetic damping has remained elusive. Ferromagnetic resonance (FMR) measurements up to 110 GHz and 5 T, as well as angle-dependent FMR measurements at 9.5 and 17 GHz, are used to discriminate between different mechanisms of FMR damping in thin films (, 4, 8, and 18). A constant isotropic Gilbert parameter is used to phenomenologically describe the magnetization damping for each composition, increasing from 0.005 to 0.022 as the amount of Cr increases from 0% to 18%. Two thirds of this contribution appear to be accounted for by intrinsic spin-orbit damping, and the balance is mostly due to extrinsic two-magnon scattering. While the introduction of Cr increases the spin-orbit damping, it nevertheless reduces the corresponding magnetic relaxation rate. The amorphous films with a high scattering rate exhibit a so-called conductivitylike damping at room temperature, in agreement with the breathing Fermi surface model. The presence of Cr also seems to inhibit internal fluctuations of the magnetization, reducing the two-magnon damping. The reduction of due to lower magnetization is partly mitigated by the overall increase in magnetic damping.- Open Access
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
Large-scale vibrating coil magnetometer for the magnetic characterization of bulk superconductors
This work presents the design and validation of a vibrating coil magnetometer for the characterization of the field dependence of the critical current density of centimeter-sized bulk superconductors as an alternative to the destructive methods typically used. The magnetometer is also shown to be capable of measuring the magnetic moment in an applied field of up to 5 T for diverse magnetic materials, such as soft and hard ferromagnets and high-temperature superconducting pellets. The vibrating coil magnetometer was first optimized using finite element simulations and calibrated using a commercial vibrating sample magnetometer. The vibrating coil magnetometer was benchmarked with hysteresis measurements of a Nd2Fe14B disk made with a commercial hysteresisgraph, showing good agreement between the different setups. The magnetic hysteresis of a YBa2Cu3O7−x superconducting pellet was measured at 77 K, showing a penetration field of 1 T and an irreversibility field of 4 T. The field dependent critical current density of the superconductor was then inferred from the magnetic hysteresis measurements and extrapolated at low fields. Finally, the resulting critical current density was used to successfully reproduce the measured magnetization curve of the pellet at 2 T with finite element simulations.
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
Open AccessLarge-scale vibrating coil magnetometer for the magnetic characterization of bulk superconductors
This work presents the design and validation of a vibrating coil magnetometer for the characterization of the field dependence of the critical current density of centimeter-sized bulk superconductors as an alternative to the destructive methods typically used. The magnetometer is also shown to be capable of measuring the magnetic moment in an applied field of up to 5 T for diverse magnetic materials, such as soft and hard ferromagnets and high-temperature superconducting pellets. The vibrating coil magnetometer was first optimized using finite element simulations and calibrated using a commercial vibrating sample magnetometer. The vibrating coil magnetometer was benchmarked with hysteresis measurements of a Nd2Fe14B disk made with a commercial hysteresisgraph, showing good agreement between the different setups. The magnetic hysteresis of a YBa2Cu3O7−x superconducting pellet was measured at 77 K, showing a penetration field of 1 T and an irreversibility field of 4 T. The field dependent critical current density of the superconductor was then inferred from the magnetic hysteresis measurements and extrapolated at low fields. Finally, the resulting critical current density was used to successfully reproduce the measured magnetization curve of the pellet at 2 T with finite element simulations.
- 28 November 2021
- Published by Springer Nature
- p. 1297-1331
Electron Paramagnetic and Ferromagnetic Resonance
- 28 November 2021
- Published by Springer Nature
- p. 1297-1331
Electron Paramagnetic and Ferromagnetic Resonance
- 28 May 2021
- Published by Springer Nature
- p. 1-35
Electron Paramagnetic and Ferromagnetic Resonance
- 30 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (2) , 1-4
Optimization of Magnetoelastic Torquemeter Designs
The performance of magnetoelastic torquemeters based on the changes in a measurable magnetic field is obtained with a simplified numerical model, assuming isotropic magnetoelastic properties throughout the ferromagnetic shaft and independent magnetic cells. The output gain of two torquemeter designs is obtained as a function of the distance of the magnetometers and of the width of the magnetic bands. Results show that a radial sensor configuration gives a gain 1.76 times larger in average than an axial sensor configuration. It is also shown that the radial configuration is more sensitive to magnetometer position errors, and requires a tighter control over the device parameters to maintain a constant gain. Further computations reveal that fluctuations in the magnetization of the shaft decrease the gain, increases the signal offset and that the shaft radius can alter this dependency due to an enhance magnetoelastic response.
- 30 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (2) , 1-4
Optimization of Magnetoelastic Torquemeter Designs
The performance of magnetoelastic torquemeters based on the changes in a measurable magnetic field is obtained with a simplified numerical model, assuming isotropic magnetoelastic properties throughout the ferromagnetic shaft and independent magnetic cells. The output gain of two torquemeter designs is obtained as a function of the distance of the magnetometers and of the width of the magnetic bands. Results show that a radial sensor configuration gives a gain 1.76 times larger in average than an axial sensor configuration. It is also shown that the radial configuration is more sensitive to magnetometer position errors, and requires a tighter control over the device parameters to maintain a constant gain. Further computations reveal that fluctuations in the magnetization of the shaft decrease the gain, increases the signal offset and that the shaft radius can alter this dependency due to an enhance magnetoelastic response.
- 1 November 2017
- Published by Elsevier in Scripta Materialia
- Vol. 140, 63-66
The effect of Al substitution on the structural and magnetic properties of epitaxial thin films of epsilon ferrite
- 1 November 2017
- Published by Elsevier in Scripta Materialia
- Vol. 140, 63-66
The effect of Al substitution on the structural and magnetic properties of epitaxial thin films of epsilon ferrite
- 1 October 2017
- Published by Elsevier in Water Research
- Vol. 123, 30-39
The influence of iron oxide nanoparticles upon the adsorption of organic matter on magnetic powdered activated carbon
- 1 October 2017
- Published by Elsevier in Water Research
- Vol. 123, 30-39
The influence of iron oxide nanoparticles upon the adsorption of organic matter on magnetic powdered activated carbon
- 4 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (21) , 6888-6894
Study of the Low-Frequency Excess Equivalent Magnetic Noise in GMI-Based Devices
Low-frequency equivalent magnetic noise levels of four different giant magneto-impedance (GMI) samples, exhibiting 1/f spectral behavior, have been experimentally determined, for several excitation conditions (involving both dc current and ac excitation amplitude). Under appropriate conditions, for which the noise level at 1 Hz is minimal, coherence measurements show that the main noise source responsible for this low frequency noise is the intrinsic noise of the GMI sample. The lowest corresponding magnetic noise performances of the four samples were determined. The lowest noise level observed was 17 pT/(Hz)1/2 at 1 Hz. It has been proposed that the imaginary part of the magnetic susceptibility, χ", a measure of the low frequency magnetization fluctuations, determines the resulting magnetic noise level of the sensor. Its values at 1 Hz have been been evaluated for all four samples. Using these evaluations, expected noise levels at 1 Hz are computed, based on a previously proposed theoretical model, and compared with the measured noise performances. Under conditions for which correlation measurements show that system noise is dominated by sensor noise, the two sets of values are in reasonably good agreement, suggesting that the proposed model for low frequency excess noise of GMI materials is essentially correct.
- 4 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (21) , 6888-6894
Study of the Low-Frequency Excess Equivalent Magnetic Noise in GMI-Based Devices
Low-frequency equivalent magnetic noise levels of four different giant magneto-impedance (GMI) samples, exhibiting 1/f spectral behavior, have been experimentally determined, for several excitation conditions (involving both dc current and ac excitation amplitude). Under appropriate conditions, for which the noise level at 1 Hz is minimal, coherence measurements show that the main noise source responsible for this low frequency noise is the intrinsic noise of the GMI sample. The lowest corresponding magnetic noise performances of the four samples were determined. The lowest noise level observed was 17 pT/(Hz)1/2 at 1 Hz. It has been proposed that the imaginary part of the magnetic susceptibility, χ", a measure of the low frequency magnetization fluctuations, determines the resulting magnetic noise level of the sensor. Its values at 1 Hz have been been evaluated for all four samples. Using these evaluations, expected noise levels at 1 Hz are computed, based on a previously proposed theoretical model, and compared with the measured noise performances. Under conditions for which correlation measurements show that system noise is dominated by sensor noise, the two sets of values are in reasonably good agreement, suggesting that the proposed model for low frequency excess noise of GMI materials is essentially correct.