Trilochan Penthia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Trilochan Penthia has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Anup Kumar Panda
Department of Electrical Engineering National Institute of Technology Rourkela Rourkela India
12 shared publicationsMrutyunjaya Mangaraj
Department of Electrical Engineering, National Institute of Technology, Rourkela, India
5 shared publications- Mrutyunjaya Mangaraj
SRM University
5 shared publications Sunil Kumar Sarangi
4 shared publicationsNishant Patnaik
Department of Electrical & Electronics Engineering ANITS Visakhapatnam India
3 shared publications- Anup Kumar Panda
Department of Electrical Engineering, National Institute of Technology Rourkela, Rourkela, India
2 shared publications
Latest Publications
- 27 August 2020
- Published by Taylor & Francis in EPE Journal
- Vol. 31 (1) , 1-16
Real-time simulation and performance of DSTATCOM using an improved load current detection-based control technique for compensation of current harmonics and load transients
Current harmonics are introduced in a distribution system due to the increasing utilization of nonlinear loads. Therefore, elimination of harmonics from supply current is an inevitable task to do. In this paper, an adaptive control technique called I-cos-theta (Icosθ) control algorithm along with a Kernel-based training method is proposed in a fuel cell-based Distributed STATic COMpensator (DSTATCOM) simulation for harmonic compensation. Specifically, the direct and quadrature components of the load current are extracted and retrained using the Kernel-based Icosθ control algorithm. The control algorithm is implemented to generate reference currents, and then the appropriate switching pulses for the Voltage Source Inverter (VSI) of the DSTATCOM. The fuel cell is intended to maintain the DC-link voltage of the DSTATCOM during different loading conditions for power quality improvement. Further, the DC-link voltage is maintained constant at 530 V with an acceptable voltage regulation of <±16%, even under load transients and temporary supply failure conditions. Moreover, the simulation of the fuel cell-based DSTATCOM has been performed in Sim Power System (SPS)/MATLAB Simulink software. Also, a low power rated prototype is developed to verify the proposed simulation model, incorporating with the dSPACE1104 real-time environment.
- 27 August 2020
- Published by Taylor & Francis in EPE Journal
- Vol. 31 (1) , 1-16
Real-time simulation and performance of DSTATCOM using an improved load current detection-based control technique for compensation of current harmonics and load transients
Current harmonics are introduced in a distribution system due to the increasing utilization of nonlinear loads. Therefore, elimination of harmonics from supply current is an inevitable task to do. In this paper, an adaptive control technique called I-cos-theta (Icosθ) control algorithm along with a Kernel-based training method is proposed in a fuel cell-based Distributed STATic COMpensator (DSTATCOM) simulation for harmonic compensation. Specifically, the direct and quadrature components of the load current are extracted and retrained using the Kernel-based Icosθ control algorithm. The control algorithm is implemented to generate reference currents, and then the appropriate switching pulses for the Voltage Source Inverter (VSI) of the DSTATCOM. The fuel cell is intended to maintain the DC-link voltage of the DSTATCOM during different loading conditions for power quality improvement. Further, the DC-link voltage is maintained constant at 530 V with an acceptable voltage regulation of <±16%, even under load transients and temporary supply failure conditions. Moreover, the simulation of the fuel cell-based DSTATCOM has been performed in Sim Power System (SPS)/MATLAB Simulink software. Also, a low power rated prototype is developed to verify the proposed simulation model, incorporating with the dSPACE1104 real-time environment.
- 8 May 2020
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 48 (8) , 769-780
Experimental Validation of ADALINE Least Mean Square Algorithm in a Three-Phase Four-Wire DSTATCOM to Enhance Power Quality
The requirement of a robust and adaptive control algorithm in active filters is inevitable nowadays. In this paper, an ADAptive LINEar neuron (ADALINE) based Least Mean Square (LMS) control algorithm is proposed for a three-phase-four-wire (3P4W) distribution power system under unbalanced loading conditions. The proposed controller has a unique inbuilt characteristic to extract the fundamental active positive sequence component from an unbalanced load current. Particularly, the control algorithm is intended to calculate an adaptive and suitable amplitude for the three-phase reference source currents which are used for the switching pulse generation in the subsequent steps. Moreover, the Distribution STATic COMpensator (DSTATCOM) is performed to eliminate harmonic contents of supply current and harmful excessive neutral current in the system. Further, the DC-link voltage is regulated in order to reduce the power loss across the DSTATCOM, and to attain a balanced, high-quality power availability at the Point of Common Coupling (PCC). The proposed system is accomplished in the MATLAB2014a/Simulink, and a low power rated 3P4W DSTATCOM prototype incorporating with the dSPACE1104 real-time environment to verify the proposed control algorithm.
- 8 May 2020
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 48 (8) , 769-780
Experimental Validation of ADALINE Least Mean Square Algorithm in a Three-Phase Four-Wire DSTATCOM to Enhance Power Quality
The requirement of a robust and adaptive control algorithm in active filters is inevitable nowadays. In this paper, an ADAptive LINEar neuron (ADALINE) based Least Mean Square (LMS) control algorithm is proposed for a three-phase-four-wire (3P4W) distribution power system under unbalanced loading conditions. The proposed controller has a unique inbuilt characteristic to extract the fundamental active positive sequence component from an unbalanced load current. Particularly, the control algorithm is intended to calculate an adaptive and suitable amplitude for the three-phase reference source currents which are used for the switching pulse generation in the subsequent steps. Moreover, the Distribution STATic COMpensator (DSTATCOM) is performed to eliminate harmonic contents of supply current and harmful excessive neutral current in the system. Further, the DC-link voltage is regulated in order to reduce the power loss across the DSTATCOM, and to attain a balanced, high-quality power availability at the Point of Common Coupling (PCC). The proposed system is accomplished in the MATLAB2014a/Simulink, and a low power rated 3P4W DSTATCOM prototype incorporating with the dSPACE1104 real-time environment to verify the proposed control algorithm.
- Open Access
- 25 March 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (10) , 1872-1881
Performance of SMES system with non‐linear dynamic evolution control approach for pulsed power load compensation
Superconducting magnetic energy storage (SMES) system is one of the efficient pulsed power compensators. Its response to the load fluctuations is faster and competent. This study proposes a non‐linear dynamic evolution control (NDEC) approach for SMES system. The control approach is implemented to regulate the error of three‐phase compensating current and DC‐link voltage. The control functions required for voltage source inverter (VSI) and bi‐directional DC–DC converter of the SMES system are derived using the NDEC control approach. A proportional–integral (PI) controller is replaced by the NDEC in the inner loop of a traditional pulse‐width‐modulation control strategy of VSI for the quick response and effective energy exchange. The elementary idea of implementing NDEC is to govern the system dynamics by maintaining a zero‐error state irrespective of load uncertainties quickly. Detrimental high rating stress on the system due to pulsed power load is substantially reduced with the proposed NDEC strategy. Source current is maintained almost balanced and harmonic‐free in order to ensure a quality and reliable supply to surrounding loads. The variation in source current is drastically reduced from 260 to 6% using the proposed system. Moreover, a comparative study between PI and NDEC‐based control scheme is presented using MATLAB simulation and experimental results.
- 25 March 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (10) , 1872-1881
Open AccessPerformance of SMES system with non‐linear dynamic evolution control approach for pulsed power load compensation
Superconducting magnetic energy storage (SMES) system is one of the efficient pulsed power compensators. Its response to the load fluctuations is faster and competent. This study proposes a non‐linear dynamic evolution control (NDEC) approach for SMES system. The control approach is implemented to regulate the error of three‐phase compensating current and DC‐link voltage. The control functions required for voltage source inverter (VSI) and bi‐directional DC–DC converter of the SMES system are derived using the NDEC control approach. A proportional–integral (PI) controller is replaced by the NDEC in the inner loop of a traditional pulse‐width‐modulation control strategy of VSI for the quick response and effective energy exchange. The elementary idea of implementing NDEC is to govern the system dynamics by maintaining a zero‐error state irrespective of load uncertainties quickly. Detrimental high rating stress on the system due to pulsed power load is substantially reduced with the proposed NDEC strategy. Source current is maintained almost balanced and harmonic‐free in order to ensure a quality and reliable supply to surrounding loads. The variation in source current is drastically reduced from 260 to 6% using the proposed system. Moreover, a comparative study between PI and NDEC‐based control scheme is presented using MATLAB simulation and experimental results.
- Open Access
- 19 December 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (3) , 516-524
Adaptive LMBP training‐based icosϕ control technique for DSTATCOM
In this study, the design and implementation of a new hybrid soft computing control technique called Levenberg–Marquardt backpropagation (LMBP)‐based icosϕ is proposed. Two different compensation techniques are evaluated for the performance analysis of three‐phase three‐wire (3P3W) voltage source converter (VSC)‐based DSTATCOM. The first one is the conventional icosϕ control technique whereas the other one is called the LMBP‐based icosϕ control technique. The better power quality of the system is obtained using the proposed control algorithm by maintaining a less voltage across the capacitor as compared to the conventional one. So, the reduction in the size of the DSTATCOM is realised by the LMBP‐based control algorithm. Furthermore, the performance parameters such as load balancing, harmonics elimination, power factor improvement, and voltage regulation are evaluated under both balanced and unbalanced loading conditions as per the IEEE guidelines. The effectiveness of the proposed controller is studied in the MATLAB/Simulink environment and also validated with a low power rated prototype experimental results.
- 19 December 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (3) , 516-524
Open AccessAdaptive LMBP training‐based icosϕ control technique for DSTATCOM
In this study, the design and implementation of a new hybrid soft computing control technique called Levenberg–Marquardt backpropagation (LMBP)‐based icosϕ is proposed. Two different compensation techniques are evaluated for the performance analysis of three‐phase three‐wire (3P3W) voltage source converter (VSC)‐based DSTATCOM. The first one is the conventional icosϕ control technique whereas the other one is called the LMBP‐based icosϕ control technique. The better power quality of the system is obtained using the proposed control algorithm by maintaining a less voltage across the capacitor as compared to the conventional one. So, the reduction in the size of the DSTATCOM is realised by the LMBP‐based control algorithm. Furthermore, the performance parameters such as load balancing, harmonics elimination, power factor improvement, and voltage regulation are evaluated under both balanced and unbalanced loading conditions as per the IEEE guidelines. The effectiveness of the proposed controller is studied in the MATLAB/Simulink environment and also validated with a low power rated prototype experimental results.
- 26 September 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (2) , e2728
Design and implementation of a cascaded transformer coupled multilevel inverter-based shunt active filter under different grid voltage conditions
- 26 September 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (2) , e2728
Design and implementation of a cascaded transformer coupled multilevel inverter-based shunt active filter under different grid voltage conditions
- 1 February 2018
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 95, 275-286
Implementing dynamic evolution control approach for DC-link voltage regulation of superconducting magnetic energy storage system
- 1 February 2018
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 95, 275-286
Implementing dynamic evolution control approach for DC-link voltage regulation of superconducting magnetic energy storage system
- 2 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 6 (4) , 1884-1891
Closed-Loop-Controlled Cascaded Current-Controlled Dynamic Evolution Control-Based Voltage-Doubler PFC Converter for Improved Dynamic Performance
In this paper, the closed-loop performance of Voltage-Doubler Power Factor Correction (VD PFC) converter under Dynamic Evolution Control (DEC) scheme is examined. The VD PFC circuit mainly used for enhancing low-line efficiency with reduced conduction and switching losses is essentially required to operate at high duty ratio (say D > 0.5). The proposed DEC scheme ensures this operating feature even under transient conditions. Since, researchers haven’t focused on the dynamic performance of the closed-loop controller for the VD PFC converter, the effectiveness of the proposed DEC technique is comparatively evaluated by implementing it in different control loops. In this research work, the DEC is separately implemented in voltage control loop and in current control loop which is termed as VC-DEC scheme and CC-DEC scheme respectively. The dynamic performance (quick response of desired output) and voltage-doubler property of the VD PFC converter under the open-loop condition, VC-DEC scheme, CC-DEC scheme are tested at a low-line input range of 70VRMS to 100VRMS to justify its characteristics of enhanced low-line efficiency. Besides, its performance is tested for different loading conditions based on several key performance indices. The relevant switching functions for VD PFC converter are derived by considering its system dynamics and corresponding loop dynamic. A hardware prototype of 390 VDC, 1.5 kW VD-PFC is designed with the controller being implemented using MATLAB/Simulink and dSPACE1104 interface.
- 2 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 6 (4) , 1884-1891
Closed-Loop-Controlled Cascaded Current-Controlled Dynamic Evolution Control-Based Voltage-Doubler PFC Converter for Improved Dynamic Performance
In this paper, the closed-loop performance of Voltage-Doubler Power Factor Correction (VD PFC) converter under Dynamic Evolution Control (DEC) scheme is examined. The VD PFC circuit mainly used for enhancing low-line efficiency with reduced conduction and switching losses is essentially required to operate at high duty ratio (say D > 0.5). The proposed DEC scheme ensures this operating feature even under transient conditions. Since, researchers haven’t focused on the dynamic performance of the closed-loop controller for the VD PFC converter, the effectiveness of the proposed DEC technique is comparatively evaluated by implementing it in different control loops. In this research work, the DEC is separately implemented in voltage control loop and in current control loop which is termed as VC-DEC scheme and CC-DEC scheme respectively. The dynamic performance (quick response of desired output) and voltage-doubler property of the VD PFC converter under the open-loop condition, VC-DEC scheme, CC-DEC scheme are tested at a low-line input range of 70VRMS to 100VRMS to justify its characteristics of enhanced low-line efficiency. Besides, its performance is tested for different loading conditions based on several key performance indices. The relevant switching functions for VD PFC converter are derived by considering its system dynamics and corresponding loop dynamic. A hardware prototype of 390 VDC, 1.5 kW VD-PFC is designed with the controller being implemented using MATLAB/Simulink and dSPACE1104 interface.