Salvador Luque
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Salvador Luque has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- José González-Aguilar
High Temperature Processes Unit, IMDEA Energy, Avda. Ramón de la Sagra 3, 28935 Móstoles, Spain
8 shared publications - Thomas Povey
Univ Oxford, Dept Engn Sci, Parks Rd, Oxford OX1 3PJ, England
7 shared publications Manuel Romero
4 shared publications- Manuel Romero
IMDEA Energy Institute, Avda. Ramón de la Sagra, 3, 28935 Móstoles, Spain
4 shared publications Sergio Santiago
Unit of High Temperature Processes; IMDEA Energy Institute; Avda. Ramón de la Sagra 3, 28935 Móstoles Spain
3 shared publicationsT. V. Jones
Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK
2 shared publications
Latest Publications
- 1 January 2020
- Published by Elsevier
- p. 586-599
Open Volumetric Air Receiver: Current Status, Challenges and Innovative Solutions
- 1 January 2020
- Published by Elsevier
- p. 586-599
Open Volumetric Air Receiver: Current Status, Challenges and Innovative Solutions
- 1 November 2018
- Published by Elsevier in Solar Energy
- Vol. 174, 342-351
Exploiting volumetric effects in novel additively manufactured open solar receivers
- 1 November 2018
- Published by Elsevier in Solar Energy
- Vol. 174, 342-351
Exploiting volumetric effects in novel additively manufactured open solar receivers
- 3 January 2018
- Published by Wiley in Journal of Heat Transfer
- Vol. 140 (4)
A New Transient High Heat Flux Convection Calibration Facility for Heat Transfer Gauges in High Enthalpy Flows
This paper presents a novel transient method for calibrating heat transfer gauges for convective wall heat flux measurements in high enthalpy flows. The new method relies on the transient heating of sensor substrates under rapid exposure to a hot flow in order to obtain the necessary reference heat flux. Compared to previous calibration facilities, the new facility is simple, inexpensive, easy to adapt for different flow configurations and sensor geometries, and quick to run across a wide range of conditions. In this paper, the design of the new calibration facility is described and the transient calibration method explained. The method is demonstrated by calibrating a Gardon gauge at convective heat transfer coefficients between 300 and 600 W/m2 K. Typical facility data and calibration results are presented in terms of voltage-heat flux sensitivity and calibration correction ratio. These results are shown to agree with theoretical estimates within the estimated calibration uncertainty.
- 3 January 2018
- Published by Wiley in Journal of Heat Transfer
- Vol. 140 (4)
A New Transient High Heat Flux Convection Calibration Facility for Heat Transfer Gauges in High Enthalpy Flows
This paper presents a novel transient method for calibrating heat transfer gauges for convective wall heat flux measurements in high enthalpy flows. The new method relies on the transient heating of sensor substrates under rapid exposure to a hot flow in order to obtain the necessary reference heat flux. Compared to previous calibration facilities, the new facility is simple, inexpensive, easy to adapt for different flow configurations and sensor geometries, and quick to run across a wide range of conditions. In this paper, the design of the new calibration facility is described and the transient calibration method explained. The method is demonstrated by calibrating a Gardon gauge at convective heat transfer coefficients between 300 and 600 W/m2 K. Typical facility data and calibration results are presented in terms of voltage-heat flux sensitivity and calibration correction ratio. These results are shown to agree with theoretical estimates within the estimated calibration uncertainty.
- 28 September 2017
- Published by Wiley in International Journal of Energy Research
- Vol. 42 (3) , 966-976
A new calorimetric facility to investigate radiative-convective heat exchangers for concentrated solar power applications
- 28 September 2017
- Published by Wiley in International Journal of Energy Research
- Vol. 42 (3) , 966-976
A new calorimetric facility to investigate radiative-convective heat exchangers for concentrated solar power applications
- 19 July 2017
- Published by Wiley in Journal of Turbomachinery
- Vol. 139 (11) , 111005
Effects of Coolant Density, Specific Heat Capacity, and Biot Number on Turbine Vane Cooling Effectiveness
This paper describes the effects of coolant-to-mainstream density ratio and specific heat capacity flux ratio (the product of blowing ratio and specific heat capacity ratio) on the overall cooling effectiveness of high pressure (HP) turbine vanes. Experimental measurements have been conducted at correct engine-matched conditions of Mach number, Reynolds number, turbulence intensity, and coolant-to-mainstream momentum flux ratio. Vanes tested were fully cooled production parts from an engine currently in service. A foreign gas mixture of SF6 and Ar was selected for injection as coolant in the facility so that density and blowing ratios were also matched to the engine situation. The isentropic exponent of the foreign gas mixture coincides with that of air. Full-coverage surface maps of overall cooling effectiveness were acquired by an infrared (IR) thermography technique at a range of mainstream-to-coolant temperature ratios. Measurements were subsequently scaled to engine conditions by employing a new theory based on the principle of superposition and a recovery and redistribution temperature demonstrated in previous papers. It is shown that the two aerodynamically matched situations of air- and foreign-gas-cooled experiments give virtually the same effectiveness trends and patterns. Actual levels differ, however, on account of specific heat capacity flux ratio differences. The effect is described and quantified by a one-dimensional analytical model of the vane wall. Differences in Biot number with respect to engine conditions are discussed as they also influence the scaling of turbine metal temperatures.
- 19 July 2017
- Published by Wiley in Journal of Turbomachinery
- Vol. 139 (11) , 111005
Effects of Coolant Density, Specific Heat Capacity, and Biot Number on Turbine Vane Cooling Effectiveness
This paper describes the effects of coolant-to-mainstream density ratio and specific heat capacity flux ratio (the product of blowing ratio and specific heat capacity ratio) on the overall cooling effectiveness of high pressure (HP) turbine vanes. Experimental measurements have been conducted at correct engine-matched conditions of Mach number, Reynolds number, turbulence intensity, and coolant-to-mainstream momentum flux ratio. Vanes tested were fully cooled production parts from an engine currently in service. A foreign gas mixture of SF6 and Ar was selected for injection as coolant in the facility so that density and blowing ratios were also matched to the engine situation. The isentropic exponent of the foreign gas mixture coincides with that of air. Full-coverage surface maps of overall cooling effectiveness were acquired by an infrared (IR) thermography technique at a range of mainstream-to-coolant temperature ratios. Measurements were subsequently scaled to engine conditions by employing a new theory based on the principle of superposition and a recovery and redistribution temperature demonstrated in previous papers. It is shown that the two aerodynamically matched situations of air- and foreign-gas-cooled experiments give virtually the same effectiveness trends and patterns. Actual levels differ, however, on account of specific heat capacity flux ratio differences. The effect is described and quantified by a one-dimensional analytical model of the vane wall. Differences in Biot number with respect to engine conditions are discussed as they also influence the scaling of turbine metal temperatures.
- 15 March 2017
- Published by Wiley in Journal of Turbomachinery
- Vol. 139 (8) , 081001
Scaling of Turbine Metal Temperatures in Cooled Compressible Flows—Experimental Demonstration of a New Theory
Experimental measurements of overall cooling effectiveness conducted on a high-pressure turbine vane in a warm rig flow are scaled to engine conditions in this paper. A new theory for the scaling of turbine metal temperatures in cooled compressible flows has been applied, based on the principle of superposition, and demonstrated analytically and numerically in a previous paper. The analysis employs a definition of overall cooling effectiveness based on a new recovery and redistribution temperature, which makes it independent of the temperature boundary conditions of the hot and cold flow streams. This enables the vane external wall temperatures to be scaled to engine conditions by varying, in a fixed aerodynamic field, the mainstream-to-coolant temperature ratio. Experimental validation of the theory is provided in this article. Measurements were conducted in the Annular Sector Heat Transfer Facility, which employs fully cooled nozzle guide vanes, production parts of a civil aviation engine currently in service. Mainstream Mach and Reynolds numbers, inlet turbulence intensity, and coolant-to-mainstream total pressure ratio (and thus momentum flux ratio) are all matched to engine conditions. Full-coverage overall cooling effectiveness distributions, acquired by infrared thermography, are presented for a range of mainstream-to-coolant temperature ratios between 1.05 and 1.22 and subsequently scaled to engine conditions by an iterative procedure. In reducing to practice the principles of the new scaling theory, it is demonstrated that direct validation of turbine cooling system performance is possible in experiments at lower than engine temperatures.
- 15 March 2017
- Published by Wiley in Journal of Turbomachinery
- Vol. 139 (8) , 081001
Scaling of Turbine Metal Temperatures in Cooled Compressible Flows—Experimental Demonstration of a New Theory
Experimental measurements of overall cooling effectiveness conducted on a high-pressure turbine vane in a warm rig flow are scaled to engine conditions in this paper. A new theory for the scaling of turbine metal temperatures in cooled compressible flows has been applied, based on the principle of superposition, and demonstrated analytically and numerically in a previous paper. The analysis employs a definition of overall cooling effectiveness based on a new recovery and redistribution temperature, which makes it independent of the temperature boundary conditions of the hot and cold flow streams. This enables the vane external wall temperatures to be scaled to engine conditions by varying, in a fixed aerodynamic field, the mainstream-to-coolant temperature ratio. Experimental validation of the theory is provided in this article. Measurements were conducted in the Annular Sector Heat Transfer Facility, which employs fully cooled nozzle guide vanes, production parts of a civil aviation engine currently in service. Mainstream Mach and Reynolds numbers, inlet turbulence intensity, and coolant-to-mainstream total pressure ratio (and thus momentum flux ratio) are all matched to engine conditions. Full-coverage overall cooling effectiveness distributions, acquired by infrared thermography, are presented for a range of mainstream-to-coolant temperature ratios between 1.05 and 1.22 and subsequently scaled to engine conditions by an iterative procedure. In reducing to practice the principles of the new scaling theory, it is demonstrated that direct validation of turbine cooling system performance is possible in experiments at lower than engine temperatures.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
Ultra-modular 500m2 heliostat field for high flux/high temperature solar-driven processes
The main objective of the European Project SUN-to-LIQUID is the scale-up and experimental demonstration of the complete process chain to solar liquid fuels from H2O and CO2. This implies moving from a 4 kW laboratory setup to a pre-commercial plant including a heliostat field. The small power and high irradiance onto the focal spot is forcing the optical design to behave half way between a large solar furnace and an extremely small central receiver system. The customized heliostat field makes use of the most recent developments on small size heliostats and a tower with reduced optical height (15 m) to minimize visual impact. A heliostat field of 250kWth (500 m2 reflective surface) has been built adjacent to IMDEA Energy premises at the Technology Park of Móstoles, Spain, and consists of 169 small size heliostats (1.9 m × 1.6 m). In spite of the small size and compactness of the field, when all heliostats are aligned, it is possible to fulfil the specified flux above 2500 kW/m2 for at least 50 kW and an aperture of 16 cm, with a peak flux of 3000 kW/m2.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
Ultra-modular 500m2 heliostat field for high flux/high temperature solar-driven processes
The main objective of the European Project SUN-to-LIQUID is the scale-up and experimental demonstration of the complete process chain to solar liquid fuels from H2O and CO2. This implies moving from a 4 kW laboratory setup to a pre-commercial plant including a heliostat field. The small power and high irradiance onto the focal spot is forcing the optical design to behave half way between a large solar furnace and an extremely small central receiver system. The customized heliostat field makes use of the most recent developments on small size heliostats and a tower with reduced optical height (15 m) to minimize visual impact. A heliostat field of 250kWth (500 m2 reflective surface) has been built adjacent to IMDEA Energy premises at the Technology Park of Móstoles, Spain, and consists of 169 small size heliostats (1.9 m × 1.6 m). In spite of the small size and compactness of the field, when all heliostats are aligned, it is possible to fulfil the specified flux above 2500 kW/m2 for at least 50 kW and an aperture of 16 cm, with a peak flux of 3000 kW/m2.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1850, 030034
A parametric experimental study of aerothermal performance and efficiency in monolithic volumetric absorbers
This paper presents experimental thermal efficiency measurements conducted on nine monolithic absorbers manufactured in siliconized silicon carbide with square flow channels. The effects of two geometric parameters on efficiency have been investigated: flow channel width and absorber length. Experiments have been conducted in the test bench for optical and thermal absorber characterizations at the IMDEA Energy Institute, which employs a 7 kWe (1.2 kWth) high flux solar simulator. The facility is modular in design and allows for a rapid interchangeability of the test components. Experimental measurements are benchmarked against on-sun tests conducted in a pilot deployment with a similar monolithic configuration. The effects of absorber cross-sectional geometry on thermal efficiency are discussed. It is generally concluded that a significantly larger effect of the forced convection heat transfer mechanism with respect to the radiative mode is necessary in order to achieve the volumetric effect in this type of monolithic absorbers.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1850, 030034
A parametric experimental study of aerothermal performance and efficiency in monolithic volumetric absorbers
This paper presents experimental thermal efficiency measurements conducted on nine monolithic absorbers manufactured in siliconized silicon carbide with square flow channels. The effects of two geometric parameters on efficiency have been investigated: flow channel width and absorber length. Experiments have been conducted in the test bench for optical and thermal absorber characterizations at the IMDEA Energy Institute, which employs a 7 kWe (1.2 kWth) high flux solar simulator. The facility is modular in design and allows for a rapid interchangeability of the test components. Experimental measurements are benchmarked against on-sun tests conducted in a pilot deployment with a similar monolithic configuration. The effects of absorber cross-sectional geometry on thermal efficiency are discussed. It is generally concluded that a significantly larger effect of the forced convection heat transfer mechanism with respect to the radiative mode is necessary in order to achieve the volumetric effect in this type of monolithic absorbers.