Gang Wan
Gang Wan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Lori Gardi
3 shared publicationsAaron Fenster
Robarts Research Institute (Canada) and Univ. of Western Ontario (Canada) and London Health Sciences Ctr. (Canada)
2 shared publicationsZhouping Wei
Robarts Research Institute (Canada) and Univ. of Western Ontario (Canada)
2 shared publications- Aaron Fenster
Robarts Research Institute, Western University
1 shared publication Donal B. Downey
Robarts Research Institute (Canada) and London Health Sciences Ctr. (Canada)
1 shared publication- Donal B. Downey
Department of Diagnostic Radiology and Nuclear Medicine, London Health Sciences Centre, London, Ontario, Canada
1 shared publication
Latest Publications
- 30 September 2014
- Published by Taylor & Francis in Collection Management
- Vol. 39 (4) , 253-274
Collecting and Digitizing Forgotten Graduate Student Scholarship: The PILOs Project at Texas A&M University
This article describes a project at Texas A&M University Libraries to add a group of legacy student works (Projects in Lieu of Theses or Dissertations, or PILOs) to the collections in both hard copy and digital form. These unique works of institutional scholarship constitute a new area of acquisition for the libraries. The authors describe the new team-based workflows necessitated to evaluate, acquire, catalog, store, digitize, and preserve these reports. The cross-unit team that designed and implemented the project has devised a successful model upon which future collection development efforts can be built.
- 30 September 2014
- Published by Taylor & Francis in Collection Management
- Vol. 39 (4) , 253-274
Collecting and Digitizing Forgotten Graduate Student Scholarship: The PILOs Project at Texas A&M University
This article describes a project at Texas A&M University Libraries to add a group of legacy student works (Projects in Lieu of Theses or Dissertations, or PILOs) to the collections in both hard copy and digital form. These unique works of institutional scholarship constitute a new area of acquisition for the libraries. The authors describe the new team-based workflows necessitated to evaluate, acquire, catalog, store, digitize, and preserve these reports. The cross-unit team that designed and implemented the project has devised a successful model upon which future collection development efforts can be built.
- 22 July 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (1-2) , 265-272
Sensing hydrogen peroxide using a glassy carbon electrode modified with in-situ electrodeposited platinum-gold bimetallic nanoclusters on a graphene surface
- 22 July 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (1-2) , 265-272
Sensing hydrogen peroxide using a glassy carbon electrode modified with in-situ electrodeposited platinum-gold bimetallic nanoclusters on a graphene surface
- 1 July 2010
- Published by Wiley in Learned Publishing
- Vol. 23 (3) , 225-236
Knowing your users: the value of article database usage analysis
- 1 July 2010
- Published by Wiley in Learned Publishing
- Vol. 23 (3) , 225-236
Knowing your users: the value of article database usage analysis
- 1 September 2008
- Published by Taylor & Francis in Science & Technology Libraries
- Vol. 28 (4) , 289-306
Evaluating ENGnetBASE, an Engineering E‐book Database
This paper examines the content, currency, and usability of CRC Press's ENGnetBASE, a collection of engineering handbooks published in electronic format. CRC Press's editorial staff's responses to a set of questions on e‐content publication practices show that the print and electronic formats are published concurrently, print titles are not dropped from the database, and some CRC titles are released to other electronic book databases. The usage statistics from ENGnetBASE for Texas A&M indicate that users accessed the database from various locations, viewed titles throughout the day, and in many instances used the library catalog to access the titles. Best practices and lessons learned from this study include suggestions on how to maximize access to ENGnetBASE, such as by adding MARC records into the library catalog to provide an additional access point and by marketing to populations identified by the usage statistics.
- 1 September 2008
- Published by Taylor & Francis in Science & Technology Libraries
- Vol. 28 (4) , 289-306
Evaluating ENGnetBASE, an Engineering E‐book Database
This paper examines the content, currency, and usability of CRC Press's ENGnetBASE, a collection of engineering handbooks published in electronic format. CRC Press's editorial staff's responses to a set of questions on e‐content publication practices show that the print and electronic formats are published concurrently, print titles are not dropped from the database, and some CRC titles are released to other electronic book databases. The usage statistics from ENGnetBASE for Texas A&M indicate that users accessed the database from various locations, viewed titles throughout the day, and in many instances used the library catalog to access the titles. Best practices and lessons learned from this study include suggestions on how to maximize access to ENGnetBASE, such as by adding MARC records into the library catalog to provide an additional access point and by marketing to populations identified by the usage statistics.
- Open Access
- 1 June 2006
- Published by American Library Association in Information Technology and Libraries
- Vol. 25 (2) , 88-94
Visualizations for Digital Libraries
The concept of digital libraries is familiar to both librarians and library patrons today. These new libraries have broken the limits of space and distance by delivering information in various formats via the Internet. Since most digital libraries contain a colossal amount of information, it is critical to design more user-friendly interfaces to explore, understand, and manage their content. One important technique for designing such interfaces is information visualization. Although computer-aided information visualization is a relatively new research area, numerous visualization applications already exist in various fields today. Furthermore, many library professionals are also starting to realize that combining information visualization techniques and current library technologies, such as digital libraries, can help library users find information more effectively and efficiently. This article first discusses three major tasks that most visualization for digital libraries emphasize, and then introduces several current applications of information visualization for digital libraries.
- 1 June 2006
- Published by American Library Association in Information Technology and Libraries
- Vol. 25 (2) , 88-94
Open AccessVisualizations for Digital Libraries
The concept of digital libraries is familiar to both librarians and library patrons today. These new libraries have broken the limits of space and distance by delivering information in various formats via the Internet. Since most digital libraries contain a colossal amount of information, it is critical to design more user-friendly interfaces to explore, understand, and manage their content. One important technique for designing such interfaces is information visualization. Although computer-aided information visualization is a relatively new research area, numerous visualization applications already exist in various fields today. Furthermore, many library professionals are also starting to realize that combining information visualization techniques and current library technologies, such as digital libraries, can help library users find information more effectively and efficiently. This article first discusses three major tasks that most visualization for digital libraries emphasize, and then introduces several current applications of information visualization for digital libraries.
- 16 March 2005
- Published by Wiley in Medical Physics
- Vol. 32 (4) , 902-909
Brachytherapy needle deflection evaluation and correction
In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively.
- 16 March 2005
- Published by Wiley in Medical Physics
- Vol. 32 (4) , 902-909
Brachytherapy needle deflection evaluation and correction
In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively.
- 5 May 2004
- Published by SPIE-Intl Soc Optical Eng
- p. 361-370
Robotic-aided 3D TRUS guided intraoperative prostate brachytherapy
We have developed a robotic aided 3D transrectal ultrasound (TRUS) guided, intraoperative prostate brachytherapy. This system allows brachytherapy needles to be inserted into the prostate along various trajectories including oblique to avoid pubic arch interference. We unified the robotic coordinate system with the 3D TRUS image coordinate system. In addition, we also hdeveloped the method to automatically detect the needle in TRUS images for oblique insertion. We have evaluated our prototype system using prostate phantoms in terms of different needle insertion depths and the distances of the needle from the TRUS transducer. We have shown that our robotic aided 3D TRUS guided system was capable of placing the needle tip with approximately 0.74 mm ± 0.24 mm accuracy at a target identified in the 3D TRUS image. Brachytherapy accuracy was tested by dropping 0.8 mm beads into prostate phantoms via various angles up to ± 20°. Our results showed that the bead-dropping accuracy was 2.59 mm ± 0.76 mm with the error due to the needle deflection caused by the needle's bevel.
- 5 May 2004
- Published by SPIE-Intl Soc Optical Eng
- p. 361-370
Robotic-aided 3D TRUS guided intraoperative prostate brachytherapy
We have developed a robotic aided 3D transrectal ultrasound (TRUS) guided, intraoperative prostate brachytherapy. This system allows brachytherapy needles to be inserted into the prostate along various trajectories including oblique to avoid pubic arch interference. We unified the robotic coordinate system with the 3D TRUS image coordinate system. In addition, we also hdeveloped the method to automatically detect the needle in TRUS images for oblique insertion. We have evaluated our prototype system using prostate phantoms in terms of different needle insertion depths and the distances of the needle from the TRUS transducer. We have shown that our robotic aided 3D TRUS guided system was capable of placing the needle tip with approximately 0.74 mm ± 0.24 mm accuracy at a target identified in the 3D TRUS image. Brachytherapy accuracy was tested by dropping 0.8 mm beads into prostate phantoms via various angles up to ± 20°. Our results showed that the bead-dropping accuracy was 2.59 mm ± 0.76 mm with the error due to the needle deflection caused by the needle's bevel.
- 6 February 2004
- Published by Wiley in Medical Physics
- Vol. 31 (3) , 539-548
Robot-assisted 3D-TRUS guided prostate brachytherapy: System integration and validation
Current transperineal prostate brachytherapy uses transrectal ultrasound (TRUS) guidance and a template at a fixed position to guide needles along parallel trajectories. However, pubic arch interference (PAI) with the implant path obstructs part of the prostate from being targeted by the brachytherapy needles along parallel trajectories. To solve the PAI problem, some investigators have explored other insertion trajectories than parallel, i.e., oblique. However, parallel trajectory constraints in current brachytherapy procedure do not allow oblique insertion. In this paper, we describe a robot-assisted, three-dimensional (3D) TRUS guided approach to solve this problem. Our prototype consists of a commercial robot, and a 3D TRUS imaging system including an ultrasound machine, image acquisition apparatus and 3D TRUS image reconstruction, and display software. In our approach, we use the robot as a movable needle guide, i.e., the robot positions the needle before insertion, but the physician inserts the needle into the patient's prostate. In a later phase of our work, we will include robot insertion. By unifying the robot, ultrasound transducer, and the 3D TRUS image coordinate systems, the position of the template hole can be accurately related to 3D TRUS image coordinate system, allowing accurate and consistent insertion of the needle via the template hole into the targeted position in the prostate. The unification of the various coordinate systems includes two steps, i.e., 3D image calibration and robot calibration. Our testing of the system showed that the needle placement accuracy of the robot system at the "patient's" skin position was 0.15 mm+/-0.06 mm, and the mean needle angulation error was 0.07 degrees. The fiducial localization error (FLE) in localizing the intersections of the nylon strings for image calibration was 0.13 mm, and the FLE in localizing the divots for robot calibration was 0.37 mm. The fiducial registration error for image calibration was 0.12 mm and 0.52 mm for robot calibration. The target registration error for image calibration was 0.23 mm, and 0.68 mm for robot calibration. Evaluation of the complete system showed that needles can be used to target positions in agar phantoms with a mean error of 0.79 mm+/-0.32 mm.
- 6 February 2004
- Published by Wiley in Medical Physics
- Vol. 31 (3) , 539-548
Robot-assisted 3D-TRUS guided prostate brachytherapy: System integration and validation
Current transperineal prostate brachytherapy uses transrectal ultrasound (TRUS) guidance and a template at a fixed position to guide needles along parallel trajectories. However, pubic arch interference (PAI) with the implant path obstructs part of the prostate from being targeted by the brachytherapy needles along parallel trajectories. To solve the PAI problem, some investigators have explored other insertion trajectories than parallel, i.e., oblique. However, parallel trajectory constraints in current brachytherapy procedure do not allow oblique insertion. In this paper, we describe a robot-assisted, three-dimensional (3D) TRUS guided approach to solve this problem. Our prototype consists of a commercial robot, and a 3D TRUS imaging system including an ultrasound machine, image acquisition apparatus and 3D TRUS image reconstruction, and display software. In our approach, we use the robot as a movable needle guide, i.e., the robot positions the needle before insertion, but the physician inserts the needle into the patient's prostate. In a later phase of our work, we will include robot insertion. By unifying the robot, ultrasound transducer, and the 3D TRUS image coordinate systems, the position of the template hole can be accurately related to 3D TRUS image coordinate system, allowing accurate and consistent insertion of the needle via the template hole into the targeted position in the prostate. The unification of the various coordinate systems includes two steps, i.e., 3D image calibration and robot calibration. Our testing of the system showed that the needle placement accuracy of the robot system at the "patient's" skin position was 0.15 mm+/-0.06 mm, and the mean needle angulation error was 0.07 degrees. The fiducial localization error (FLE) in localizing the intersections of the nylon strings for image calibration was 0.13 mm, and the FLE in localizing the divots for robot calibration was 0.37 mm. The fiducial registration error for image calibration was 0.12 mm and 0.52 mm for robot calibration. The target registration error for image calibration was 0.23 mm, and 0.68 mm for robot calibration. Evaluation of the complete system showed that needles can be used to target positions in agar phantoms with a mean error of 0.79 mm+/-0.32 mm.