Saeed Kermani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Saeed Kermani has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Hamid Sanei
Isfahan Cardiovascular Research Center, Cardiovascular Research Institute Isfahan University of Medical Sciences Isfahan Iran
3 shared publications - Hossein Rabbani
Medical Image and Signal Processing Research Center, School of Advanced Technologies in Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
3 shared publications Hossein Yousefi-Banaem
3 shared publicationsAlireza Daneshmehr
2 shared publications- Alireza Mehri Dehnavi
Affiliation Department of Bioelectrics and Biomedical Engineering, School of Advanced Technologies in Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
2 shared publications - Daryoush Shahbazi-Gahrouei
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
2 shared publications
Latest Publications
- Open Access
- 1 March 2025
- Published by Wolters Kluwer Health in Journal of Medical Signals & Sensors
- Vol. 15 (3) , 8
Predicting Severe Knee Arthritis Based on Two Inertial Measurement Unit Sensors as a Dynamic Coordinate System Using Classical Machine Learning
Background: Aging of societies in recent and upcoming years has made musculoskeletal disorders a significant challenge for healthcare system. Knee osteoarthritis (KOA) is a progressive musculoskeletal disorder that is typically diagnosed using radiographs. Considering the drawbacks of X-ray imaging, such as exposure to ionizing radiation, the need for a noninvasive, low-cost alternative method for diagnosing KOA is essential. The purpose of this study was to evaluate the ability of a wearable device to differentiate between healthy individuals and those with severe osteoarthritis (grade 4). Methods: The wearable device consisted of two inertial measurement unit (IMU) sensors, one on the lower leg and one on the thigh. One of the sensors is used as a dynamic coordinate system to improve the accuracy of the measurements. In this study, to discriminate between 1433 labeled IMU signals collected from 15 healthy individuals and 15 people with severe KOA aged over 45, new features were extracted and defined in dynamic coordinates. These features were employed in four different classifiers: (1) naive Bayes, (2) K-nearest neighbors (KNNs), (3) support vector machine, and (4) random forest. Each classifier was evaluated using the 10-fold cross-validation method (K = 10). The data were applied to these models, and based on their outputs, four performance metrics – accuracy, precision, sensitivity, and specificity – were calculated to assess the classification of these two groups using the mentioned software. Results: The evaluation of the selected classifiers involved calculating the four specified metrics and their average and variance values. The highest accuracy was achieved by KNN, with an accuracy of 93.71 ± 1.1 and a precision of 93 ± 1.31. Conclusion: The novel features based on the dynamic coordinate system, along with the success of the proposed KNN model, demonstrate the effectiveness of the proposed algorithm in diagnosing between signals received from healthy individuals and patients. The proposed algorithm outperforms existing methods in similar articles in sensitivity showing an improvement of 4% and at least. The main objective of this study is to investigate the feasibility of using a wearable device as an auxiliary tool in the diagnosis of arthritis. The reported results in this study are related to two groups of individuals with severe arthritis (grade 4), and there is a possibility of weaker results with the current method.
- 1 March 2025
- Published by Wolters Kluwer Health in Journal of Medical Signals & Sensors
- Vol. 15 (3) , 8
Open AccessPredicting Severe Knee Arthritis Based on Two Inertial Measurement Unit Sensors as a Dynamic Coordinate System Using Classical Machine Learning
Background: Aging of societies in recent and upcoming years has made musculoskeletal disorders a significant challenge for healthcare system. Knee osteoarthritis (KOA) is a progressive musculoskeletal disorder that is typically diagnosed using radiographs. Considering the drawbacks of X-ray imaging, such as exposure to ionizing radiation, the need for a noninvasive, low-cost alternative method for diagnosing KOA is essential. The purpose of this study was to evaluate the ability of a wearable device to differentiate between healthy individuals and those with severe osteoarthritis (grade 4). Methods: The wearable device consisted of two inertial measurement unit (IMU) sensors, one on the lower leg and one on the thigh. One of the sensors is used as a dynamic coordinate system to improve the accuracy of the measurements. In this study, to discriminate between 1433 labeled IMU signals collected from 15 healthy individuals and 15 people with severe KOA aged over 45, new features were extracted and defined in dynamic coordinates. These features were employed in four different classifiers: (1) naive Bayes, (2) K-nearest neighbors (KNNs), (3) support vector machine, and (4) random forest. Each classifier was evaluated using the 10-fold cross-validation method (K = 10). The data were applied to these models, and based on their outputs, four performance metrics – accuracy, precision, sensitivity, and specificity – were calculated to assess the classification of these two groups using the mentioned software. Results: The evaluation of the selected classifiers involved calculating the four specified metrics and their average and variance values. The highest accuracy was achieved by KNN, with an accuracy of 93.71 ± 1.1 and a precision of 93 ± 1.31. Conclusion: The novel features based on the dynamic coordinate system, along with the success of the proposed KNN model, demonstrate the effectiveness of the proposed algorithm in diagnosing between signals received from healthy individuals and patients. The proposed algorithm outperforms existing methods in similar articles in sensitivity showing an improvement of 4% and at least. The main objective of this study is to investigate the feasibility of using a wearable device as an auxiliary tool in the diagnosis of arthritis. The reported results in this study are related to two groups of individuals with severe arthritis (grade 4), and there is a possibility of weaker results with the current method.
- Open Access
- 29 May 2023
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 13 (2) , 160-164
Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming
Automating the camera Lucida method which is a standard way for focusing microscopic images is a very challenging study for many scientists. Hence, actually combining hardware and software to automate microscopic imaging systems is one of the most important issues in the field of medicine as well. This idea reduces scanning time and increases the accuracy of user's results in this field. Closed-loop control system has been designed and implemented in the hardware part to move the stage in predefined limits of 15°. This system produces 50 consecutive images from parasites at the mentioned spatial distances in two directions of the z-axis. Then, by introducing our proposed relational software with combining images, a high-contrast image can be presented. This colored image is focused on many subparts of the sample even with different ruggedness. After implementing the closed-loop controller, stages movement was repeated eight times with an average step displacement of 20 μm which were measured in two directions of the z-axis by a digital micrometer. On average, the movement's error was 1 μm. In software, the edge intensity energy index has been calculated for image quality evaluation. The standard camera Lucida method has been simulated with acceptable results based on experts' opinions and also mean squared error parameters. Mechanical movement in stage has an accuracy of about 95% which will meet the expectations of laboratory user. Although output-focused colored images from our combining software can be replaced by the traditional fully accepted Camera Lucida method.
- 29 May 2023
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 13 (2) , 160-164
Open AccessAutomated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming
Automating the camera Lucida method which is a standard way for focusing microscopic images is a very challenging study for many scientists. Hence, actually combining hardware and software to automate microscopic imaging systems is one of the most important issues in the field of medicine as well. This idea reduces scanning time and increases the accuracy of user's results in this field. Closed-loop control system has been designed and implemented in the hardware part to move the stage in predefined limits of 15°. This system produces 50 consecutive images from parasites at the mentioned spatial distances in two directions of the z-axis. Then, by introducing our proposed relational software with combining images, a high-contrast image can be presented. This colored image is focused on many subparts of the sample even with different ruggedness. After implementing the closed-loop controller, stages movement was repeated eight times with an average step displacement of 20 μm which were measured in two directions of the z-axis by a digital micrometer. On average, the movement's error was 1 μm. In software, the edge intensity energy index has been calculated for image quality evaluation. The standard camera Lucida method has been simulated with acceptable results based on experts' opinions and also mean squared error parameters. Mechanical movement in stage has an accuracy of about 95% which will meet the expectations of laboratory user. Although output-focused colored images from our combining software can be replaced by the traditional fully accepted Camera Lucida method.
- Open Access
- 1 October 2021
- Published by Medknow in Journal of Microscopy and Ultrastructure
- Vol. 9 (4) , 170-176
Automated Drawing Tube (Camera Lucida) Method in Light Microscopy Images Analysis Can Comes True
Background: In a light microscope, image acquisition with different component depths is difficult, and there are various approaches for solving this problem. One of the common approaches is Camera Lucida (CL). This method has some disadvantages such as time-consuming, handed problems in painting, causing user boring, and produce gray scale output images. Aims and Objectives: In this study, we purposed a novel-combined hardware and software method. In this article, we try to present an automated method for our designed microscope. Materials and Methods: We have done a project with designed code number 377,694 to design and implement an upgraded light microscope. That project was about automatic movement of a stage with closed-looped control of a servomotor. Furthermore, automated camera catches images in predefined positions. That project has acceptable results in different parts, which encourage us to work on this study. This study help specialist have good fixative of all components in a sample. It is about trying to have useful Lucida Camera (drawing tube) in an automated scheme. Results: This method is an acceptable usual way for microscopic specialists, but with some disadvantages. It is time-consuming and boring that effect on the accuracy of results. Hence, how can be good if automated similar method could be implemented is exciting and affective. This studies idea comes from the basis of manual drawing tube (CL) method. In this experimental study, we have taken 400 handed an image of microorganisms. Captured images are from its whole body or various organs. They have been captured in different z-axis positions of stage, and hence components with different depths could be focused. Each patch checked for its edge strength to choose highest resolutions sub image and reconstruct focused image like a puzzle. This process has been continued for all areas to merge and complete reconstructed image as output. Conclusion: Comparing edge strength with other images and mean square error with manual focused on confirm our method with pleasure outcomes. Furthermore, independent focusing of an internal component in a sample body has been surveyed. It helps to have better resolution in internal selected component for more analysis and replace in its primitive image. This article presents efficient consequences with good accuracy and saving time in process period, which could be useful in different microscopes types and various samples type.
- 1 October 2021
- Published by Medknow in Journal of Microscopy and Ultrastructure
- Vol. 9 (4) , 170-176
Open AccessAutomated Drawing Tube (Camera Lucida) Method in Light Microscopy Images Analysis Can Comes True
Background: In a light microscope, image acquisition with different component depths is difficult, and there are various approaches for solving this problem. One of the common approaches is Camera Lucida (CL). This method has some disadvantages such as time-consuming, handed problems in painting, causing user boring, and produce gray scale output images. Aims and Objectives: In this study, we purposed a novel-combined hardware and software method. In this article, we try to present an automated method for our designed microscope. Materials and Methods: We have done a project with designed code number 377,694 to design and implement an upgraded light microscope. That project was about automatic movement of a stage with closed-looped control of a servomotor. Furthermore, automated camera catches images in predefined positions. That project has acceptable results in different parts, which encourage us to work on this study. This study help specialist have good fixative of all components in a sample. It is about trying to have useful Lucida Camera (drawing tube) in an automated scheme. Results: This method is an acceptable usual way for microscopic specialists, but with some disadvantages. It is time-consuming and boring that effect on the accuracy of results. Hence, how can be good if automated similar method could be implemented is exciting and affective. This studies idea comes from the basis of manual drawing tube (CL) method. In this experimental study, we have taken 400 handed an image of microorganisms. Captured images are from its whole body or various organs. They have been captured in different z-axis positions of stage, and hence components with different depths could be focused. Each patch checked for its edge strength to choose highest resolutions sub image and reconstruct focused image like a puzzle. This process has been continued for all areas to merge and complete reconstructed image as output. Conclusion: Comparing edge strength with other images and mean square error with manual focused on confirm our method with pleasure outcomes. Furthermore, independent focusing of an internal component in a sample body has been surveyed. It helps to have better resolution in internal selected component for more analysis and replace in its primitive image. This article presents efficient consequences with good accuracy and saving time in process period, which could be useful in different microscopes types and various samples type.
- 28 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (9) , 3576-3586
A Multichannel Intraluminal Impedance Gastroesophageal Reflux Characterization Algorithm Based On Sparse Representation
Gastroesophageal reflux disease (GERD) is a common digestive disorder with troublesome symptoms that has been affected millions of people worldwide. Multichannel Intraluminal ImpedancepH (MIIpH) monitoring is a recently developed technique, which is currently considered as the gold standard for the diagnosis of GERD. In this paper, we address the problem of characterizing gastroesophageal reflux events in MII signals. A GER detection algorithm has been developed based on the sparse representation of local segments. Two dictionaries are trained using the online dictionary learning approach from the distal impedance data of selected patches of GER and no specific patterns intervals. A classifier is then designed based on the l_pnorm of dictionary approximations. Next, a preliminary permutation mask is obtained from the classification results of patches, which is then used in postprocessing procedure to investigate the exact timings of GERs at all impedance sites. Our algorithm was tested on 33 MII episodes, resulting a sensitivity of 96.97% and a positive predictive value of 94.12%.
- 28 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (9) , 3576-3586
A Multichannel Intraluminal Impedance Gastroesophageal Reflux Characterization Algorithm Based On Sparse Representation
Gastroesophageal reflux disease (GERD) is a common digestive disorder with troublesome symptoms that has been affected millions of people worldwide. Multichannel Intraluminal ImpedancepH (MIIpH) monitoring is a recently developed technique, which is currently considered as the gold standard for the diagnosis of GERD. In this paper, we address the problem of characterizing gastroesophageal reflux events in MII signals. A GER detection algorithm has been developed based on the sparse representation of local segments. Two dictionaries are trained using the online dictionary learning approach from the distal impedance data of selected patches of GER and no specific patterns intervals. A classifier is then designed based on the l_pnorm of dictionary approximations. Next, a preliminary permutation mask is obtained from the classification results of patches, which is then used in postprocessing procedure to investigate the exact timings of GERs at all impedance sites. Our algorithm was tested on 33 MII episodes, resulting a sensitivity of 96.97% and a positive predictive value of 94.12%.
- Open Access
- 1 January 2020
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 10 (2) , 105-112
On the bioactivity and mechanical properties of gehlenite nanobioceramic: A comparative study
Ty are assessed and compared with hydroxyapatite (HA) for bone tissue regeneration. Method: Gehlenite and HA nanoparticles are synthesized through sol–gel method and coprecipitation technique, respectively, and their physical and chemical properties are characterized through X-ray diffraction, Fourier transform infrared spectroscopy, and transmission electron microscopy. Results: The results prove that the gehlenite and HA phases without any undesirable phase are obtained, and the particles of both compounds are in the nanometer range with spherical morphology. The compressive strength of both compounds are assessed, and the values for gehlenite and HA disks are 144 ± 5 and 150 ± 4.8 MPa, respectively. Next, their bioactivity potential is assessed into simulated body fluid (SBF) up to 21 days, and the results show that after 14 days, gehlenite disk's surface is completely covered with newly formed Ca-P particles. However, some sporadic precipitations after 21 days soaking into SBF are formed onto the HA disk's surface. Conclusion: This comparative study shows that nanostructured gehlenite disk with desirable mechanical properties and faster bioactivity kinetic than HA can be considered as a promising bioceramic for bone tissue regeneration....
- 1 January 2020
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 10 (2) , 105-112
Open AccessOn the bioactivity and mechanical properties of gehlenite nanobioceramic: A comparative study
Ty are assessed and compared with hydroxyapatite (HA) for bone tissue regeneration. Method: Gehlenite and HA nanoparticles are synthesized through sol–gel method and coprecipitation technique, respectively, and their physical and chemical properties are characterized through X-ray diffraction, Fourier transform infrared spectroscopy, and transmission electron microscopy. Results: The results prove that the gehlenite and HA phases without any undesirable phase are obtained, and the particles of both compounds are in the nanometer range with spherical morphology. The compressive strength of both compounds are assessed, and the values for gehlenite and HA disks are 144 ± 5 and 150 ± 4.8 MPa, respectively. Next, their bioactivity potential is assessed into simulated body fluid (SBF) up to 21 days, and the results show that after 14 days, gehlenite disk's surface is completely covered with newly formed Ca-P particles. However, some sporadic precipitations after 21 days soaking into SBF are formed onto the HA disk's surface. Conclusion: This comparative study shows that nanostructured gehlenite disk with desirable mechanical properties and faster bioactivity kinetic than HA can be considered as a promising bioceramic for bone tissue regeneration....
- Open Access
- 1 January 2020
- Published by Institution of Engineering and Technology (IET) in IET Image Processing
- Vol. 14 (1) , 132-137
Automatic detection of acute lymphoblastic leukaemia based on extending the multifractal features
The main purpose of this study is to introduce a new species of features to improve the diagnosis efficiency of acute lymphoblastic leukaemia from microscopic images. First, the authors segmented nuclei by the k ‐means and watershed algorithms. They extracted three sets of geometrical, statistical, and chaotic features from nuclei images. Six chaotic features were extracted by calculating the fractal dimension from five sub‐images driven from the nuclei images, with their grey levels being modified. The authors classified the images into binary and multiclass types via the support vector machine algorithm. They conducted principal component analysis for dimensional reduction of feature space and then evaluated the proposed algorithm for the overfitting problem. The obtained overall results represent 99% accuracy, 99% specificity, and 97% sensitivity values in the classification of six‐cell groups. The difference between the train and test errors was <3%, which proves that the classification performance had improved by using the multifractal features.
- 1 January 2020
- Published by Institution of Engineering and Technology (IET) in IET Image Processing
- Vol. 14 (1) , 132-137
Open AccessAutomatic detection of acute lymphoblastic leukaemia based on extending the multifractal features
The main purpose of this study is to introduce a new species of features to improve the diagnosis efficiency of acute lymphoblastic leukaemia from microscopic images. First, the authors segmented nuclei by the k ‐means and watershed algorithms. They extracted three sets of geometrical, statistical, and chaotic features from nuclei images. Six chaotic features were extracted by calculating the fractal dimension from five sub‐images driven from the nuclei images, with their grey levels being modified. The authors classified the images into binary and multiclass types via the support vector machine algorithm. They conducted principal component analysis for dimensional reduction of feature space and then evaluated the proposed algorithm for the overfitting problem. The obtained overall results represent 99% accuracy, 99% specificity, and 97% sensitivity values in the classification of six‐cell groups. The difference between the train and test errors was <3%, which proves that the classification performance had improved by using the multifractal features.
- 1 October 2018
- Published by Elsevier in Physica Medica
- Vol. 54, 103-116
A hybrid graph-based approach for right ventricle segmentation in cardiac MRI by long axis information transition
- 1 October 2018
- Published by Elsevier in Physica Medica
- Vol. 54, 103-116
A hybrid graph-based approach for right ventricle segmentation in cardiac MRI by long axis information transition
- 1 June 2018
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 159, 103-109
The design and validation of a hybrid digital-signal-processing plug-in for traditional cochlear implant speech processors
- 1 June 2018
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 159, 103-109
The design and validation of a hybrid digital-signal-processing plug-in for traditional cochlear implant speech processors
- Open Access
- 1 January 2018
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 8 (1) , 53-59
Designing an Inverter-based Operational Transconductance Amplifier-capacitor Filter with Low Power Consumption for Biomedical Applications
The operational transconductance amplifier-capacitor (OTA-C) filter is one of the best structures for implementing continuous-time filters. It is particularly important to design a universal OTA-C filter capable of generating the desired filter response via a single structure, thus reducing the filter circuit power consumption as well as noise and the occupied space on the electronic chip. In this study, an inverter-based universal OTA-C filter with very low power consumption and acceptable noise was designed with applications in bioelectric and biomedical equipment for recording biomedical signals. The very low power consumption of the proposed filter was achieved through introducing bias in subthreshold MOSFET transistors. The proposed filter is also capable of simultaneously receiving favorable low-, band-, and high-pass filter responses. The performance of the proposed filter was simulated and analyzed via HSPICE software (level 49) and 180 nm complementary metal-oxide-semiconductor technology. The rate of power consumption and noise obtained from simulations are 7.1 nW and 10.18 nA, respectively, so this filter has reduced noise as well as power consumption. The proposed universal OTA-C filter was designed based on the minimum number of transconductance blocks and an inverter circuit by three transconductance blocks (OTA).
- 1 January 2018
- Published by Medknow in Journal of Medical Signals & Sensors
- Vol. 8 (1) , 53-59
Open AccessDesigning an Inverter-based Operational Transconductance Amplifier-capacitor Filter with Low Power Consumption for Biomedical Applications
The operational transconductance amplifier-capacitor (OTA-C) filter is one of the best structures for implementing continuous-time filters. It is particularly important to design a universal OTA-C filter capable of generating the desired filter response via a single structure, thus reducing the filter circuit power consumption as well as noise and the occupied space on the electronic chip. In this study, an inverter-based universal OTA-C filter with very low power consumption and acceptable noise was designed with applications in bioelectric and biomedical equipment for recording biomedical signals. The very low power consumption of the proposed filter was achieved through introducing bias in subthreshold MOSFET transistors. The proposed filter is also capable of simultaneously receiving favorable low-, band-, and high-pass filter responses. The performance of the proposed filter was simulated and analyzed via HSPICE software (level 49) and 180 nm complementary metal-oxide-semiconductor technology. The rate of power consumption and noise obtained from simulations are 7.1 nW and 10.18 nA, respectively, so this filter has reduced noise as well as power consumption. The proposed universal OTA-C filter was designed based on the minimum number of transconductance blocks and an inverter circuit by three transconductance blocks (OTA).