SKSaeed Kermani

Saeed Kermani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Saeed Kermani has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Predicting Severe Knee Arthritis Based on Two Inertial Measurement Unit Sensors as a Dynamic Coordinate System Using Classical Machine Learning

    by Erfan Azizi, Mohammadsadegh Darbankhalesi, Amirhossein Zare, Zahra Sadat Rezaeian, Saeed Kermani

    Background: Aging of societies in recent and upcoming years has made musculoskeletal disorders a significant challenge for healthcare system. Knee osteoarthritis (KOA) is a progressive musculoskeletal disorder that is typically diagnosed using radiographs. Considering the drawbacks of X-ray imaging, such as exposure to ionizing radiation, the need for a noninvasive, low-cost alternative method for diagnosing KOA is essential. The purpose of this study was to evaluate the ability of a wearable device to differentiate between healthy individuals and those with severe osteoarthritis (grade 4). Methods: The wearable device consisted of two inertial measurement unit (IMU) sensors, one on the lower leg and one on the thigh. One of the sensors is used as a dynamic coordinate system to improve the accuracy of the measurements. In this study, to discriminate between 1433 labeled IMU signals collected from 15 healthy individuals and 15 people with severe KOA aged over 45, new features were extracted and defined in dynamic coordinates. These features were employed in four different classifiers: (1) naive Bayes, (2) K-nearest neighbors (KNNs), (3) support vector machine, and (4) random forest. Each classifier was evaluated using the 10-fold cross-validation method (K = 10). The data were applied to these models, and based on their outputs, four performance metrics – accuracy, precision, sensitivity, and specificity – were calculated to assess the classification of these two groups using the mentioned software. Results: The evaluation of the selected classifiers involved calculating the four specified metrics and their average and variance values. The highest accuracy was achieved by KNN, with an accuracy of 93.71 ± 1.1 and a precision of 93 ± 1.31. Conclusion: The novel features based on the dynamic coordinate system, along with the success of the proposed KNN model, demonstrate the effectiveness of the proposed algorithm in diagnosing between signals received from healthy individuals and patients. The proposed algorithm outperforms existing methods in similar articles in sensitivity showing an improvement of 4% and at least. The main objective of this study is to investigate the feasibility of using a wearable device as an auxiliary tool in the diagnosis of arthritis. The reported results in this study are related to two groups of individuals with severe arthritis (grade 4), and there is a possibility of weaker results with the current method.


  • Open Access

    Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming

    by Fateme Vahabi, Saeed Kermani, Zahra Vahabi, Nader Pestechian

    Automating the camera Lucida method which is a standard way for focusing microscopic images is a very challenging study for many scientists. Hence, actually combining hardware and software to automate microscopic imaging systems is one of the most important issues in the field of medicine as well. This idea reduces scanning time and increases the accuracy of user's results in this field. Closed-loop control system has been designed and implemented in the hardware part to move the stage in predefined limits of 15°. This system produces 50 consecutive images from parasites at the mentioned spatial distances in two directions of the z-axis. Then, by introducing our proposed relational software with combining images, a high-contrast image can be presented. This colored image is focused on many subparts of the sample even with different ruggedness. After implementing the closed-loop controller, stages movement was repeated eight times with an average step displacement of 20 μm which were measured in two directions of the z-axis by a digital micrometer. On average, the movement's error was 1 μm. In software, the edge intensity energy index has been calculated for image quality evaluation. The standard camera Lucida method has been simulated with acceptable results based on experts' opinions and also mean squared error parameters. Mechanical movement in stage has an accuracy of about 95% which will meet the expectations of laboratory user. Although output-focused colored images from our combining software can be replaced by the traditional fully accepted Camera Lucida method.

  • Open Access

    Automated Drawing Tube (Camera Lucida) Method in Light Microscopy Images Analysis Can Comes True

    by Fatemeh Vahabi, Saeed Kermani, Zahra Vahabi, Nader Pestechian

    Background: In a light microscope, image acquisition with different component depths is difficult, and there are various approaches for solving this problem. One of the common approaches is Camera Lucida (CL). This method has some disadvantages such as time-consuming, handed problems in painting, causing user boring, and produce gray scale output images. Aims and Objectives: In this study, we purposed a novel-combined hardware and software method. In this article, we try to present an automated method for our designed microscope. Materials and Methods: We have done a project with designed code number 377,694 to design and implement an upgraded light microscope. That project was about automatic movement of a stage with closed-looped control of a servomotor. Furthermore, automated camera catches images in predefined positions. That project has acceptable results in different parts, which encourage us to work on this study. This study help specialist have good fixative of all components in a sample. It is about trying to have useful Lucida Camera (drawing tube) in an automated scheme. Results: This method is an acceptable usual way for microscopic specialists, but with some disadvantages. It is time-consuming and boring that effect on the accuracy of results. Hence, how can be good if automated similar method could be implemented is exciting and affective. This studies idea comes from the basis of manual drawing tube (CL) method. In this experimental study, we have taken 400 handed an image of microorganisms. Captured images are from its whole body or various organs. They have been captured in different z-axis positions of stage, and hence components with different depths could be focused. Each patch checked for its edge strength to choose highest resolutions sub image and reconstruct focused image like a puzzle. This process has been continued for all areas to merge and complete reconstructed image as output. Conclusion: Comparing edge strength with other images and mean square error with manual focused on confirm our method with pleasure outcomes. Furthermore, independent focusing of an internal component in a sample body has been surveyed. It helps to have better resolution in internal selected component for more analysis and replace in its primitive image. This article presents efficient consequences with good accuracy and saving time in process period, which could be useful in different microscopes types and various samples type.


  • A Multichannel Intraluminal Impedance Gastroesophageal Reflux Characterization Algorithm Based On Sparse Representation

    by Azra Rasouli, Hossein Rabbani, Saeed Kermani, Mostafa Raisi, Maryam Soheilipour, Peyman Adibi

    Gastroesophageal reflux disease (GERD) is a common digestive disorder with troublesome symptoms that has been affected millions of people worldwide. Multichannel Intraluminal ImpedancepH (MIIpH) monitoring is a recently developed technique, which is currently considered as the gold standard for the diagnosis of GERD. In this paper, we address the problem of characterizing gastroesophageal reflux events in MII signals. A GER detection algorithm has been developed based on the sparse representation of local segments. Two dictionaries are trained using the online dictionary learning approach from the distal impedance data of selected patches of GER and no specific patterns intervals. A classifier is then designed based on the l_pnorm of dictionary approximations. Next, a preliminary permutation mask is obtained from the classification results of patches, which is then used in postprocessing procedure to investigate the exact timings of GERs at all impedance sites. Our algorithm was tested on 33 MII episodes, resulting a sensitivity of 96.97% and a positive predictive value of 94.12%.


  • Open Access

    On the bioactivity and mechanical properties of gehlenite nanobioceramic: A comparative study

    by Saeed Kermani, Ashkan Bigham, Ahmad Saudi, AmirHamed Aghajanian, Mohammad Rafienia

    Ty are assessed and compared with hydroxyapatite (HA) for bone tissue regeneration. Method: Gehlenite and HA nanoparticles are synthesized through sol–gel method and coprecipitation technique, respectively, and their physical and chemical properties are characterized through X-ray diffraction, Fourier transform infrared spectroscopy, and transmission electron microscopy. Results: The results prove that the gehlenite and HA phases without any undesirable phase are obtained, and the particles of both compounds are in the nanometer range with spherical morphology. The compressive strength of both compounds are assessed, and the values for gehlenite and HA disks are 144 ± 5 and 150 ± 4.8 MPa, respectively. Next, their bioactivity potential is assessed into simulated body fluid (SBF) up to 21 days, and the results show that after 14 days, gehlenite disk's surface is completely covered with newly formed Ca-P particles. However, some sporadic precipitations after 21 days soaking into SBF are formed onto the HA disk's surface. Conclusion: This comparative study shows that nanostructured gehlenite disk with desirable mechanical properties and faster bioactivity kinetic than HA can be considered as a promising bioceramic for bone tissue regeneration....


  • Open Access

    Automatic detection of acute lymphoblastic leukaemia based on extending the multifractal features

    by Mohamadreza Abbasi, Saeed Kermani, Ardeshir Tajebib, Morteza Moradi Amin, Manije Abbasi

    The main purpose of this study is to introduce a new species of features to improve the diagnosis efficiency of acute lymphoblastic leukaemia from microscopic images. First, the authors segmented nuclei by the k ‐means and watershed algorithms. They extracted three sets of geometrical, statistical, and chaotic features from nuclei images. Six chaotic features were extracted by calculating the fractal dimension from five sub‐images driven from the nuclei images, with their grey levels being modified. The authors classified the images into binary and multiclass types via the support vector machine algorithm. They conducted principal component analysis for dimensional reduction of feature space and then evaluated the proposed algorithm for the overfitting problem. The obtained overall results represent 99% accuracy, 99% specificity, and 97% sensitivity values in the classification of six‐cell groups. The difference between the train and test errors was <3%, which proves that the classification performance had improved by using the multifractal features.


  • Open Access

    Designing an Inverter-based Operational Transconductance Amplifier-capacitor Filter with Low Power Consumption for Biomedical Applications

    by Saeed Kermani, Sajad Yousefinezhad, Saeed Hosseinnia

    The operational transconductance amplifier-capacitor (OTA-C) filter is one of the best structures for implementing continuous-time filters. It is particularly important to design a universal OTA-C filter capable of generating the desired filter response via a single structure, thus reducing the filter circuit power consumption as well as noise and the occupied space on the electronic chip. In this study, an inverter-based universal OTA-C filter with very low power consumption and acceptable noise was designed with applications in bioelectric and biomedical equipment for recording biomedical signals. The very low power consumption of the proposed filter was achieved through introducing bias in subthreshold MOSFET transistors. The proposed filter is also capable of simultaneously receiving favorable low-, band-, and high-pass filter responses. The performance of the proposed filter was simulated and analyzed via HSPICE software (level 49) and 180 nm complementary metal-oxide-semiconductor technology. The rate of power consumption and noise obtained from simulations are 7.1 nW and 10.18 nA, respectively, so this filter has reduced noise as well as power consumption. The proposed universal OTA-C filter was designed based on the minimum number of transconductance blocks and an inverter circuit by three transconductance blocks (OTA).