Sujatha Narayanan Unni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sujatha Narayanan Unni has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Mahima Sharma
Biophotonics Lab, Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, India
7 shared publicationsChitra Shaji
Indian Institute of Technology Madras
6 shared publicationsPriya Krishnamurthy
Biophotonics Lab, Department of Applied Mechanics and Biomedical Engineering Indian Institute of Technology Chennai India
6 shared publicationsSubitcha Jayasankar
Indian Inst Technol Madras, Dept Appl Mech & Biomed Engn, Biophoton Lab, Chennai, Tamil Nadu, India
4 shared publicationsSandhya Sundaram
Department of Pathology, Sri Ramachandra Medical College and Research Institute, SRIHER, Porur, India
3 shared publicationsSubalakshmi Balasubramanian
Department of Pathology, Sri Ramachandra Medical College and Research Institute, SRIHER, Porur, India
3 shared publications
Latest Publications
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (10) , 16471-16478
Real-Time Data-Driven Localization System for Magnetic Endocapsule Devices
This paper presents a proof-of-concept of a data-driven magnetic localization framework for magnetic endocapsule devices. First, the localization has been formulated as a regression problem using a deep neural network. Learning the direct relationship between magnetic sensor network measurements and the magnetic endocapsule spatial parameters streamlines the localization process. Second, the localization system was integrated with IoT connectivity. Unlike model-driven frameworks, the proposed data-driven framework learns the localization mapping directly from experimentally acquired measurements of the magnetic sensor network. The data-driven framework reduces reliance on analytical models and bypasses indirect, iterative model-driven localization frameworks. The IoT integration functions as a system-level advantage for real-time remote monitoring of wearable and healthcare conditions with limited resources. The magnetic sensor network comprises sixteen magnetic sensors arranged in a planar grid, covering a region of interest of 150 mm × 150 mm with an inter-sensor spacing of 50 mm. The magnetic sensor network was designed with a localization range of 60 mm, spanning from 40mmto 90 mm. The end-to-end hardware of the proposed system has been developed. The data-driven magnetic localization algorithm has been deployed on hardware. The system achieves an average position error of 3.27 ± 1.92 mm and an orientation error of 3.66 ± 1.93 degrees.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (10) , 16471-16478
Real-Time Data-Driven Localization System for Magnetic Endocapsule Devices
This paper presents a proof-of-concept of a data-driven magnetic localization framework for magnetic endocapsule devices. First, the localization has been formulated as a regression problem using a deep neural network. Learning the direct relationship between magnetic sensor network measurements and the magnetic endocapsule spatial parameters streamlines the localization process. Second, the localization system was integrated with IoT connectivity. Unlike model-driven frameworks, the proposed data-driven framework learns the localization mapping directly from experimentally acquired measurements of the magnetic sensor network. The data-driven framework reduces reliance on analytical models and bypasses indirect, iterative model-driven localization frameworks. The IoT integration functions as a system-level advantage for real-time remote monitoring of wearable and healthcare conditions with limited resources. The magnetic sensor network comprises sixteen magnetic sensors arranged in a planar grid, covering a region of interest of 150 mm × 150 mm with an inter-sensor spacing of 50 mm. The magnetic sensor network was designed with a localization range of 60 mm, spanning from 40mmto 90 mm. The end-to-end hardware of the proposed system has been developed. The data-driven magnetic localization algorithm has been deployed on hardware. The system achieves an average position error of 3.27 ± 1.92 mm and an orientation error of 3.66 ± 1.93 degrees.
- 14 February 2026
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 643
Design and development of dynamic electromagnetic system for actuation of magnetic endocapsule devices
- 14 February 2026
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 643
Design and development of dynamic electromagnetic system for actuation of magnetic endocapsule devices
- 21 January 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (3)
Transparent Non-destructive Estimation of Moisture Content In Vegetables Using Hyperspectral Imaging, Multi-target regression pipeline approach and Explainable AI
The moisture content (MC) estimation has become a significant part of assessing the nutrient value, freshness, and shelf life of post-harvested fruits and vegetables. Hence, early intervention can help maintain quality and reduce spoilage of postharvest. However, manual assessment of MC requires skilled manpower and specialised equipment, which makes it costly and prone to errors. This study presents an innovative approach that integrates explainable AI (XAI) and a machine learning model to overcome such challenges. The study develops the multi-target regression (MTR) pipeline for simultaneously automated MC estimation in various agricultural samples. Hyperspectral imaging (HSI) data of broccoli, leek, and mushrooms were utilised for experimentation purposes. The MTR pipeline comprises three stages: classification, feature extraction, and regression. Random forest classifier, Partial least square, and Stacking regression models (SRM) were used for classification, feature extraction, and regression purposes. The study used 788 VIS-NIR reflectance spectra obtained from the HSI data of broccoli, leek, and mushrooms. The proposed MTR pipeline was assessed with the coefficient of determination (R2), root mean squared error (RMSE), mean square error (MSE), and mean absolute error (MAE) scores. The overall performance score of the MTR pipeline for MC prediction on unseen datasets in the VIS to NIR range was 90.17 R2, 0.07 MSE, 1.91 RMSE, and 1.33 MAE scores. The individual proposed SRMs achieved R2 scores of 81.31±7.36 % for broccoli, 98.09±0.34% for leek, and 98.54±1.21% for mushroom. The corresponding RMSE scores were 0.65±0.13%, 0.32±0.05%, and 3.08±1.18% for broccoli, leek, and mushroom, respectively. The proposed pipeline outperforms the existing state-of-the-art (SOA) methods reported in the literature. The study illustrated the significance of wavelengths for MC estimation in agricultural samples using the Explainable AI (XAI) Shapley Additive Explanations (SHAP) tool. The promising result of the study demonstrates that the involvement of XAI with the proposed pipeline facilitates transparent MC prediction in crops, ensuring supplies of higher-quality products to consumers.
- 21 January 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (3)
Transparent Non-destructive Estimation of Moisture Content In Vegetables Using Hyperspectral Imaging, Multi-target regression pipeline approach and Explainable AI
The moisture content (MC) estimation has become a significant part of assessing the nutrient value, freshness, and shelf life of post-harvested fruits and vegetables. Hence, early intervention can help maintain quality and reduce spoilage of postharvest. However, manual assessment of MC requires skilled manpower and specialised equipment, which makes it costly and prone to errors. This study presents an innovative approach that integrates explainable AI (XAI) and a machine learning model to overcome such challenges. The study develops the multi-target regression (MTR) pipeline for simultaneously automated MC estimation in various agricultural samples. Hyperspectral imaging (HSI) data of broccoli, leek, and mushrooms were utilised for experimentation purposes. The MTR pipeline comprises three stages: classification, feature extraction, and regression. Random forest classifier, Partial least square, and Stacking regression models (SRM) were used for classification, feature extraction, and regression purposes. The study used 788 VIS-NIR reflectance spectra obtained from the HSI data of broccoli, leek, and mushrooms. The proposed MTR pipeline was assessed with the coefficient of determination (R2), root mean squared error (RMSE), mean square error (MSE), and mean absolute error (MAE) scores. The overall performance score of the MTR pipeline for MC prediction on unseen datasets in the VIS to NIR range was 90.17 R2, 0.07 MSE, 1.91 RMSE, and 1.33 MAE scores. The individual proposed SRMs achieved R2 scores of 81.31±7.36 % for broccoli, 98.09±0.34% for leek, and 98.54±1.21% for mushroom. The corresponding RMSE scores were 0.65±0.13%, 0.32±0.05%, and 3.08±1.18% for broccoli, leek, and mushroom, respectively. The proposed pipeline outperforms the existing state-of-the-art (SOA) methods reported in the literature. The study illustrated the significance of wavelengths for MC estimation in agricultural samples using the Explainable AI (XAI) Shapley Additive Explanations (SHAP) tool. The promising result of the study demonstrates that the involvement of XAI with the proposed pipeline facilitates transparent MC prediction in crops, ensuring supplies of higher-quality products to consumers.
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
Smart MDD—A portable optical device for rapid, automated, and ultra-sensitive detection of malathion in liquid samples
Pesticides are often used in agriculture to reduce post-harvest losses due to contamination and to increase productivity. Long-term exposure to these pesticides in food leads to serious health issues in humans and animals. Advanced sensing techniques are crucial for detecting pesticide traces in agricultural products present in low amounts. This study demonstrates an aptamer-based colorimetric assay for detecting organophosphorus pesticides, namely, malathion. In the absence of malathion, the aptamer binds with cationic polymer PDDA, preventing its aggregation with gold nanoparticles. Upon binding with malathion, the PDDA is left free, forming aggregation with AuNPs, resulting in a color change from red to blue. This assay is integrated into a smart optical detection device with a built-in display for standalone operations. The optical absorbance ratio (518/633 nm) was utilized as a marker to detect malathion traces in water, achieving a limit of detection of 248.36 pM within the quantification range (100–1000 pM) and a sensitivity of 0.0015 a.u./pM. Polynomial regression models were applied to compare the performance of the spectrophotometer and the device, yielding R2 values of 0.9468 and 0.9489, demonstrating a strong correlation between the intensity ratio and malathion concentration. A predictive model developed using polynomial regression to estimate malathion concentration based on the device’s measured intensity ratio achieved a root mean square error of 9.85%. These findings highlight the potential of the developed device for accurate and reliable pesticide detection. The portability and cost-effectiveness promise its use for on-site monitoring in environmental and precision agriculture settings.
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
Smart MDD—A portable optical device for rapid, automated, and ultra-sensitive detection of malathion in liquid samples
Pesticides are often used in agriculture to reduce post-harvest losses due to contamination and to increase productivity. Long-term exposure to these pesticides in food leads to serious health issues in humans and animals. Advanced sensing techniques are crucial for detecting pesticide traces in agricultural products present in low amounts. This study demonstrates an aptamer-based colorimetric assay for detecting organophosphorus pesticides, namely, malathion. In the absence of malathion, the aptamer binds with cationic polymer PDDA, preventing its aggregation with gold nanoparticles. Upon binding with malathion, the PDDA is left free, forming aggregation with AuNPs, resulting in a color change from red to blue. This assay is integrated into a smart optical detection device with a built-in display for standalone operations. The optical absorbance ratio (518/633 nm) was utilized as a marker to detect malathion traces in water, achieving a limit of detection of 248.36 pM within the quantification range (100–1000 pM) and a sensitivity of 0.0015 a.u./pM. Polynomial regression models were applied to compare the performance of the spectrophotometer and the device, yielding R2 values of 0.9468 and 0.9489, demonstrating a strong correlation between the intensity ratio and malathion concentration. A predictive model developed using polynomial regression to estimate malathion concentration based on the device’s measured intensity ratio achieved a root mean square error of 9.85%. These findings highlight the potential of the developed device for accurate and reliable pesticide detection. The portability and cost-effectiveness promise its use for on-site monitoring in environmental and precision agriculture settings.
- Open Access
- 1 July 2025
- Published by Springer Nature in Cureus Journal of Computer Science
- Vol. 2 (1)
Effective Multiclass Grapevine Leaves Disease Classification Using Hyperspectral Imaging and Optimized Artificial Neural Network
Cureus Journals Grapevine farming is one of the most common and economical agricultural practices worldwide. The grapevine crop is affected by various diseases caused by biotic or abiotic stress, which degrade production and quality. Therefore, precise identification of disease is predominant for sustainable viticulture. This article proposes a potential solution for automatically detecting various diseases, damages, and healthy samples. The study develops an optimized artificial neural network (ANN) and trains it with a composite loss function consisting of weighted categorical cross-entropy (WCCE) and label smoothing (LS). The WCCE helps address the class imbalance challenge, whereas LS prevents the model from being overconfident and makes it generalized. The study utilizes the grapevine leaf hyperspectral imaging dataset, which falls under the visible and near infrared (400-900 nm) range and has 204 bands/wavelengths from 87,305 spectra extracted via the region of interest. The 30 signature relevant wavelengths for disease detection, identified using linear discriminant analysis, are significant as they represent the most informative parts of the spectrum for disease detection, thereby helping reduce data redundancy. For further experimentation, the dataset was randomly split into Dataset-A, which contained 70% of the total spectra for a 10-fold cross-validation setting, and the remaining 30% was allocated to Dataset-B, which was reserved as an unseen dataset to evaluate the model's robustness. The optimized ANN performed best among the other classifiers in terms of performance metrics (classification accuracy, precision, recall, and F1-score). For the full range, the optimized ANN achieved 96.37%±0.26% classification accuracy on Dataset-A and 96.47% on Dataset-B. Moreover, for the significant 30 wavelengths, the optimized ANN achieved 95.47%±0.34% classification accuracy on Dataset-A and 95.17% classification accuracy on Dataset-B. The promising results demonstrated that the proposed model can be used as a mass-screening tool for potential diseases to boost the production and quality of the grape crop.
- 1 July 2025
- Published by Springer Nature in Cureus Journal of Computer Science
- Vol. 2 (1)
Open AccessEffective Multiclass Grapevine Leaves Disease Classification Using Hyperspectral Imaging and Optimized Artificial Neural Network
Cureus Journals Grapevine farming is one of the most common and economical agricultural practices worldwide. The grapevine crop is affected by various diseases caused by biotic or abiotic stress, which degrade production and quality. Therefore, precise identification of disease is predominant for sustainable viticulture. This article proposes a potential solution for automatically detecting various diseases, damages, and healthy samples. The study develops an optimized artificial neural network (ANN) and trains it with a composite loss function consisting of weighted categorical cross-entropy (WCCE) and label smoothing (LS). The WCCE helps address the class imbalance challenge, whereas LS prevents the model from being overconfident and makes it generalized. The study utilizes the grapevine leaf hyperspectral imaging dataset, which falls under the visible and near infrared (400-900 nm) range and has 204 bands/wavelengths from 87,305 spectra extracted via the region of interest. The 30 signature relevant wavelengths for disease detection, identified using linear discriminant analysis, are significant as they represent the most informative parts of the spectrum for disease detection, thereby helping reduce data redundancy. For further experimentation, the dataset was randomly split into Dataset-A, which contained 70% of the total spectra for a 10-fold cross-validation setting, and the remaining 30% was allocated to Dataset-B, which was reserved as an unseen dataset to evaluate the model's robustness. The optimized ANN performed best among the other classifiers in terms of performance metrics (classification accuracy, precision, recall, and F1-score). For the full range, the optimized ANN achieved 96.37%±0.26% classification accuracy on Dataset-A and 96.47% on Dataset-B. Moreover, for the significant 30 wavelengths, the optimized ANN achieved 95.47%±0.34% classification accuracy on Dataset-A and 95.17% classification accuracy on Dataset-B. The promising results demonstrated that the proposed model can be used as a mass-screening tool for potential diseases to boost the production and quality of the grape crop.
- Open Access
- 9 May 2025
- Published by Elsevier in Results in Surfaces and Interfaces
- Vol. 19
Laser polarization induced surface structuring of 316L stainless steel and influence on biocompatibility and antibacterial performance
- 9 May 2025
- Published by Elsevier in Results in Surfaces and Interfaces
- Vol. 19
Open AccessLaser polarization induced surface structuring of 316L stainless steel and influence on biocompatibility and antibacterial performance
- 5 March 2025
- Published by Wiley in Journal of Biophotonics
- Vol. 18 (5) , e202400565
Differentiation of Bacterial Species in Liquid Culture Using Laser Speckle Contrast Imaging
Bacterial identification is vital for healthcare and environmental quality control. Traditional bacterial identification methods require extensive sample preparation, including cultivation, staining, and microscopy, making them time‐consuming and labor‐intensive. This study proposes the application of Laser Speckle Contrast Imaging (LSCI) as a novel approach to capture variations in speckle patterns between the start and end of the lag caused by changes in the shape and arrangement of bacterial cells during cell division in liquid cultures at lower cell concentrations, such as in the lag phase. Our approach offers an efficient alternative to traditional methods of bacterial species identification demonstrated with Escherichia coli and Micrococcus luteus pairs. Also, the differentiation of strains ( E. coli ATCC25922 and DH5α) is carried out based on the percentage change in speckle contrast between the end of lag and mid‐log phase of their growth curve.
- 5 March 2025
- Published by Wiley in Journal of Biophotonics
- Vol. 18 (5) , e202400565
Differentiation of Bacterial Species in Liquid Culture Using Laser Speckle Contrast Imaging
Bacterial identification is vital for healthcare and environmental quality control. Traditional bacterial identification methods require extensive sample preparation, including cultivation, staining, and microscopy, making them time‐consuming and labor‐intensive. This study proposes the application of Laser Speckle Contrast Imaging (LSCI) as a novel approach to capture variations in speckle patterns between the start and end of the lag caused by changes in the shape and arrangement of bacterial cells during cell division in liquid cultures at lower cell concentrations, such as in the lag phase. Our approach offers an efficient alternative to traditional methods of bacterial species identification demonstrated with Escherichia coli and Micrococcus luteus pairs. Also, the differentiation of strains ( E. coli ATCC25922 and DH5α) is carried out based on the percentage change in speckle contrast between the end of lag and mid‐log phase of their growth curve.
- 10 November 2024
- Published by Elsevier in Journal of Microbiological Methods
- Vol. 227, 107068
Laser Speckle Image analysis for identifying the minimum lethal concentration of ampicillin in Escherichia coli liquid cultures
- 10 November 2024
- Published by Elsevier in Journal of Microbiological Methods
- Vol. 227, 107068
Laser Speckle Image analysis for identifying the minimum lethal concentration of ampicillin in Escherichia coli liquid cultures
- 23 September 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065026
Multi-layered silicone-based breast tissue phantom for multi-modal optical spectroscopy
The heterogeneity, non-uniform nature, and ethical concerns in sourcing biological tissues pose several challenges to designing, calibrating, standardizing, and evaluating the performance of spectroscopy-based diagnostic methods. A synthetic phantom module that can resemble a multi-layered tissue structure while including multiple tissue biomarkers with long-shelf life and stability is vital to overcome these challenges. This work uses a multi-layered silicone phantom to incorporate multiple biomarkers suitable for multi-modal spectroscopy testing and calibration. The phantom mimics the microcalcification distribution in the breast tissues using hydroxyapatite and the endogenous fluorescence seen in the tissues using Flavin Adenine Dinucleotide (FAD) and Nicotinamide Adenine Dinucleotide (NADH). The utility of this phantom for tumor margin analysis is analyzed using Diffuse reflectance, fluorescence, and Raman spectroscopy. The observed relative differences in intensity with changes in the silicone tumor layer depth and thickness are suitable for instrument calibration and fiber-optic probe design for tumor margin analysis.
- 23 September 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065026
Multi-layered silicone-based breast tissue phantom for multi-modal optical spectroscopy
The heterogeneity, non-uniform nature, and ethical concerns in sourcing biological tissues pose several challenges to designing, calibrating, standardizing, and evaluating the performance of spectroscopy-based diagnostic methods. A synthetic phantom module that can resemble a multi-layered tissue structure while including multiple tissue biomarkers with long-shelf life and stability is vital to overcome these challenges. This work uses a multi-layered silicone phantom to incorporate multiple biomarkers suitable for multi-modal spectroscopy testing and calibration. The phantom mimics the microcalcification distribution in the breast tissues using hydroxyapatite and the endogenous fluorescence seen in the tissues using Flavin Adenine Dinucleotide (FAD) and Nicotinamide Adenine Dinucleotide (NADH). The utility of this phantom for tumor margin analysis is analyzed using Diffuse reflectance, fluorescence, and Raman spectroscopy. The observed relative differences in intensity with changes in the silicone tumor layer depth and thickness are suitable for instrument calibration and fiber-optic probe design for tumor margin analysis.