Latest Publications
- Open Access
- 30 April 2013
- Published by IntechOpen
Cleaning, Disinfection and Sterilization of Heat-Sensitive Endoscopes
Open access peer-reviewed chapter
- 30 April 2013
- Published by IntechOpen
Open AccessCleaning, Disinfection and Sterilization of Heat-Sensitive Endoscopes
Open access peer-reviewed chapter
- Open Access
- 16 May 2012
- Published by Hindawi Limited in Diagnostic and Therapeutic Endoscopy
- Vol. 2012, 1-7
Rinsability of Orthophthalaldehyde from Endoscopes
Orthophthalaldehyde high level disinfectants are contraindicated for use with urological instruments such as cystoscopes due to anaphylaxis-like allergic reactions during surveillance of bladder cancer patients. Allergic reactions and mucosal injuries have also been reported following colonoscopy, laryngoscopy, and transesophageal echocardiography with devices disinfected using orthophthalaldehyde. Possibly these endoscopes were not adequately rinsed after disinfection by orthophthalaldehyde. We examined this possibility by means of a zone-of-inhibition test, and also a test to extract residues of orthophthalaldehyde with acetonitrile, from sections of endoscope insertion tube materials, to measure the presence of alkaline glutaraldehyde, or glutaraldehyde plus 20% w/w isopropanol, or ortho-phthalaldehyde that remained on the endoscope materials after exposure to these disinfectants followed by a series of rinses in water, or by aeration overnight. Zones of any size indicated the disinfectant had not been rinsed away from the endoscope material. There were no zones of inhibition surrounding endoscope materials soaked in glutaraldehyde or glutaraldehyde plus isopropanol after three serial water rinses according to manufacturers' rinsing directions. The endoscope material soaked in orthophthalaldehyde produced zones of inhibition even after fifteen serial rinses with water. Orthophthalaldehyde was extracted from the rinsed endoscope material by acetonitrile. These data, and other information, indicate that the high level disinfectant orthophthalaldehyde, also known as 1,2-benzene dialdehyde, cannot be rinsed away from flexible endoscope material with any practical number of rinses with water, or by drying overnight.
- 16 May 2012
- Published by Hindawi Limited in Diagnostic and Therapeutic Endoscopy
- Vol. 2012, 1-7
Open AccessRinsability of Orthophthalaldehyde from Endoscopes
Orthophthalaldehyde high level disinfectants are contraindicated for use with urological instruments such as cystoscopes due to anaphylaxis-like allergic reactions during surveillance of bladder cancer patients. Allergic reactions and mucosal injuries have also been reported following colonoscopy, laryngoscopy, and transesophageal echocardiography with devices disinfected using orthophthalaldehyde. Possibly these endoscopes were not adequately rinsed after disinfection by orthophthalaldehyde. We examined this possibility by means of a zone-of-inhibition test, and also a test to extract residues of orthophthalaldehyde with acetonitrile, from sections of endoscope insertion tube materials, to measure the presence of alkaline glutaraldehyde, or glutaraldehyde plus 20% w/w isopropanol, or ortho-phthalaldehyde that remained on the endoscope materials after exposure to these disinfectants followed by a series of rinses in water, or by aeration overnight. Zones of any size indicated the disinfectant had not been rinsed away from the endoscope material. There were no zones of inhibition surrounding endoscope materials soaked in glutaraldehyde or glutaraldehyde plus isopropanol after three serial water rinses according to manufacturers' rinsing directions. The endoscope material soaked in orthophthalaldehyde produced zones of inhibition even after fifteen serial rinses with water. Orthophthalaldehyde was extracted from the rinsed endoscope material by acetonitrile. These data, and other information, indicate that the high level disinfectant orthophthalaldehyde, also known as 1,2-benzene dialdehyde, cannot be rinsed away from flexible endoscope material with any practical number of rinses with water, or by drying overnight.
- 1 April 2010
- Published by Elsevier in American Journal of Infection Control
- Vol. 38 (3) , 205-211
Aldahol high-level disinfectant
- 1 April 2010
- Published by Elsevier in American Journal of Infection Control
- Vol. 38 (3) , 205-211
Aldahol high-level disinfectant
- 1 July 2007
- Published by Wolters Kluwer Health in Gastroenterology Nursing
- Vol. 30 (4) , 285-290
Sporicidal Activity of Disinfectants as One Possible Cause for Bacteria in Patient-Ready Endoscopes
Four endoscopes were cleaned by an experienced endoscopy technician using an enzyme detergent solution with brushing, rinsing with tap water, and then high-level disinfection in an automatic endoscope reprocessing machine using CIDEX orthophthalaldehyde solution (CIDEX OPA). After disinfection, the channels of these patient-ready endoscopes were flushed with sterile neutralizing medium, brushed with a sterile brush, and then flushed again with sterile medium. The effluent from each flush was collected in sterile bottles, immediately returned on ice to a laboratory, and tested for the presence of bacteria. An average of about 200 colony-forming units of bacteria were recovered from each endoscope. Upon staining and microscopic examination, 3 of these colonies were spore-forming bacteria, and 7 colonies were nonspore-forming bacteria. These results suggest that the endoscopes might have been contaminated with a biofilm. Bacterial biofilms have been speculated to commonly occur in endoscopes as a result of the many possible inadequacies of cleaning, disinfecting, rinsing, drying, storage, and other functions associated with the difficulties of reprocessing endoscopes. As one possible cause for a biofilm, three high-level disinfectants (CIDEX activated dialdehyde solution, CIDEX OPA, and Aldahol high-level disinfectant) were tested for their sporicidal activity against high-protein or low-protein cultures of spore-forming bacteria in suspension. The potential importance of killing spore-forming bacteria within a practical exposure time in order to prevent the formation of biofilms is discussed.
- 1 July 2007
- Published by Wolters Kluwer Health in Gastroenterology Nursing
- Vol. 30 (4) , 285-290
Sporicidal Activity of Disinfectants as One Possible Cause for Bacteria in Patient-Ready Endoscopes
Four endoscopes were cleaned by an experienced endoscopy technician using an enzyme detergent solution with brushing, rinsing with tap water, and then high-level disinfection in an automatic endoscope reprocessing machine using CIDEX orthophthalaldehyde solution (CIDEX OPA). After disinfection, the channels of these patient-ready endoscopes were flushed with sterile neutralizing medium, brushed with a sterile brush, and then flushed again with sterile medium. The effluent from each flush was collected in sterile bottles, immediately returned on ice to a laboratory, and tested for the presence of bacteria. An average of about 200 colony-forming units of bacteria were recovered from each endoscope. Upon staining and microscopic examination, 3 of these colonies were spore-forming bacteria, and 7 colonies were nonspore-forming bacteria. These results suggest that the endoscopes might have been contaminated with a biofilm. Bacterial biofilms have been speculated to commonly occur in endoscopes as a result of the many possible inadequacies of cleaning, disinfecting, rinsing, drying, storage, and other functions associated with the difficulties of reprocessing endoscopes. As one possible cause for a biofilm, three high-level disinfectants (CIDEX activated dialdehyde solution, CIDEX OPA, and Aldahol high-level disinfectant) were tested for their sporicidal activity against high-protein or low-protein cultures of spore-forming bacteria in suspension. The potential importance of killing spore-forming bacteria within a practical exposure time in order to prevent the formation of biofilms is discussed.