GLGregory S. Lewis

Gregory S. Lewis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gregory S. Lewis has a total of 284 co-authors. Here are the top co-authors by number of shared publications:

  • April D. Armstrong

    Department of Orthopaedics and Rehabilitation, Bone and Joint Institute, Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania

    15 shared publications
  • Evan P. Roush

    Penn State Hershey Milton S Hershey Medical Center, Hershey, Pennsylvania

    15 shared publications
  • Hwabok Wee

    Department of Orthopaedics and Rehabilitation, Penn State College of Medicine , Hershey, PA 17033

    12 shared publications
  • Stephen J. Piazza

    Biomechanics Laboratory, Department of Kinesiology, The Pennsylvania State University, University Park, PA 16802, USA

    8 shared publications
  • Allen R. Kunselman

    Department of Public Health Sciences, Penn State College of Medicine, 500 University Drive, Hershey, PA 17033, USA

    7 shared publications
  • J. Spence Reid

    Department of Orthopaedics and Therapy Services, Penn State College of Medicine, Hershey, PA 17033, USA

    7 shared publications

Latest Publications

  • Flexure-Based Locking Plates Can Modulate Interfragmentary Motion in Distal Femur and Diaphyseal Fractures: A Parametric Finite Element Analysis

    by Connor Huxman, Gary Updegrove, April Armstrong, Hwabok Wee, Mary I. Frecker, Jared Butler, Gregory S. Lewis

    Axial interfragmentary motion is known to stimulate fracture healing. A mechanically compliant fracture fixation plate incorporating flexures is proposed to provide controlled axial micromotion to long bone fractures. To explore the concept's feasibility, computational modeling of general diaphyseal and distal femur fractures treated with both rigid and compliant plates is conducted. In Part I of this study, a diaphyseal fracture finite element model for novel compliant plates is validated against experimental data with good agreement. In Part II, a parametric analysis is conducted using the validated model to characterize the performance of many compliant plate designs with varying geometry and materials. Under axial loading, all compliant plate configurations provided greater (1.03 mm versus 0.22 mm) and more symmetric (270–390%) axial interfragmentary motion than rigid plates. Steel compliant plates with thicker flexures (0.3–0.6 mm) may provide the best performance given their enhanced motion and comparable bending/torsional rigidity. In Part III, compliant plates are adapted for use in treating distal femur fractures. Results demonstrate that compared to a rigid plate, a compliant distal femur plate with increased thickness can effectively modulate interfragmentary motion—that is, increase the insufficient near cortex motion under low loads (from 0.14 mm to 0.23 mm) and reduce the excessive far cortex motion under large loads (from 7.96 mm to 2.54 mm). Flexure-based locking plates represent a promising new approach to treating diaphyseal and/or distal femur fractures. Additional research is needed to investigate in vivo performance.


  • Understanding Patient and Care Partner Experiences With Rehabilitation After Hospitalization for Advanced Heart Failure: “I Was Thinking I’d Just Be Like I Was Before I Got This”

    by Sarah Stone, Tamra Keeney, Ferhat Yildiz, Aniyah Travis, Erin Coglianese, Gregory D Lewis, Joseph A Greer, Karen Steinhauser, Amy M Pastva, Ana-Maria Vranceanu, et al.

    Importance: Advanced heart failure (HF) is a life-limiting condition that frequently necessitates hospitalization and subsequent post-acute rehabilitation for older adults. Despite high rates of post-acute care utilization, a notable gap exists in understanding the rehabilitation experiences of both patients and their care partners. Objective: The objective was to conduct semi-structured interviews with older adults hospitalized with advanced HF and their care partners to explore their prior experiences with HF rehabilitation, including perceived benefits, unmet needs, and opportunities for improvement. Design: Between 2021 and 2023, a qualitative descriptive approach was used to conduct semi-structured interviews with patients hospitalized at an urban academic medical center with advanced HF (n = 12) and care partners (n = 11). Human-centered design principles and the Framework Method were used to guide study design and analyze semi-structured interviews. Setting: Qualitative interviews were conducted at bedside, in a quiet area in the hospital, or via Zoom after discharge. Interview location was guided by participant preferences and whether the patient had previously participated in HF rehabilitation prior to their current admission or was initiating rehabilitation for the first time following their hospitalization. Participants: Patients were eligible to participate if they were community-dwelling (non-institutionalized), aged 65 years and older, had New York Heart Association Class III to IV symptoms, able to speak and read English, and had a history of receiving rehabilitation for their HF in the past (in any setting) or would be initiating it upon discharge. Patients were excluded if they were undergoing advanced therapy (organ transplant or left ventricular assist device placement), had severe cognitive impairment (diagnosis of Alzheimer disease or related dementia, delirium, or altered mental status), or were enrolled in hospice during hospitalization or at hospital discharge. Results: Three deductive domains were characterized: (1) patient and care partner rehabilitation experiences, (2) facilitators and barriers to participating in rehabilitation, and (3) recommendations for optimizing rehabilitation. In the recommendations domain, several inductive themes emerged, including: (1) enhance rehabilitation structure, (2) optimize communication between patients and therapists, (3) incorporate symptom management, and (4) provide structured activity recommendations and goals. Relevance: Older adults with advanced HF are frequently hospitalized and require post-acute rehabilitation to address impairments in physical function. Our findings characterize patient and care partner experiences with post-acute rehabilitation and identify areas for improvement that may support the development of more effective post-acute rehabilitation interventions in advanced HF.

  • Open Access

    Effects of Plate‐Bone Contact on Bridge Plate Fracture Fixation Biomechanics: Computational, Experimental, and Analytical Modeling

    by Zachary A. Koroneos, Hwabok Wee, J. Spence Reid, Gregory S. Lewis

    Bridge plating is commonly used for internal fixation of comminuted fractures. The inner working length between screws has been established as a key parameter controlling postoperative biomechanical stability. However, plate‐bone contact may affect these biomechanics in complex ways, and the offset between the plate and bone is variable across surgeries. The objective of this study was to examine the effects of construct and loading parameters on interfragmentary motion and maximum plate stress of bridge plating constructs. Finite element models were developed with variations in inner working length, plate‐bone offset, fracture gap size, and loading type and magnitudes. Experiments with synthetic bones were conducted in parallel to support model credibility. Analytical models were also developed based on beam bending and torsion of the plate, assuming rigidity outside the inner working length. Finite element and experimental results of axial and torsional loading scenarios without plate‐bone contact confirmed linear relationships between inner working length and interfragmentary motion. Analytical predictions of interfragmentary motion showed very good agreement with the finite element simulations in these scenarios. Conversely, in cases with plate‐bone contact, a shorter effective working length was formed, and results were dependent on additional variables such as fracture gap. The study shows how the mechanics of bridge plating can be understood and predicted based on beam theory up to the point of plate‐bone contact, and how interfragmentary motions and maximum plate stresses are influenced by the interaction of surgical variables in the presence of plate‐bone contact.


  • Dynamic Fracture Fixation Plates: A Systematic Review of Evolving Design Approaches

    by Connor Huxman, April Armstrong, Gary Updegrove, Gregory S. Lewis, Jared Butler

    Fracture fixation with standard locked plates can suppress interfragmentary motion beneficial for secondary bone healing. To address this limitation, dynamic fracture fixation plates have been developed which seek to maintain bending and torsional rigidity while providing controlled axial micromotion. This article provides a comprehensive systematic review of the history and current state of proposed dynamic plating technologies to better inform future development. 59 records (51 articles, 8 patents) describing 26 unique dynamic plating devices were identified across three literature and patent databases using PRISMA review guidelines. Concepts were grouped into one of 9 engineering approach categories, including plates that incorporate sliding mechanisms, elastic inserts, lattice structures, and mechanically compliant flexures, among others. Devices are compared in their technological characteristics, ranges of axial motion, stiffnesses, and levels of development. Despite many dynamic technologies demonstrating good healing results experimentally and clinically, widespread clinical adoption has not occurred. Some explanations for this are provided, including production costs for complex designs and the current co-existence of both rigid and flexible fixation approaches. Overall, dynamic plating offers a promising area of innovation to address the ongoing concerns of non-union rates associated with standard locked plating of long bone fractures.


  • Bicortical Compression and Construct Stability With Variable Pitch Locking Screws in Cadaveric Specimens: Erratum

    by Zachary A. Bsc Koroneos, Shelby Bsc Alwine, Peter Bsc Tortora, Michaela Bsc Pitcher, Christian Bsc Benedict, Hwabok Wee, Allen Ma Kunselman, Michael Aynardi, Gregory S. Lewis

  • Bicortical Compression and Construct Stability With Variable Pitch Locking Screws in Cadaveric Specimens

    by Zachary A. Bsc Koroneos, Shelby Bsc Alwine, Peter Bsc Tortora, Michaela Bsc Pitcher, Christian Bsc Benedict, Hwabok Wee, Allen Ma Kunselman, Michael Aynardi, Gregory S. Lewis

    OBJECTIVES: A variable pitch locking screw is intended to provide interfragmentary compression combined with fixed angle stability of locking plate constructs. The objective of this study was to compare variable pitch locking screws (3.5-mm KreuLock Ti locking compression screws, Arthrex Inc., Naples, FL) with standard locking screws (from the same manufacturer) in bicortical fixation scenarios in cadaver bone by assessing (1) interfragmentary compression and plate-bone compression and (2) construct biomechanical stability. METHODS: Nine matched pairs of fresh-frozen cadaveric specimens with an average age of 67.2 years (range, 37–83) were used. Interfragmentary compression and plate-bone compression associated with insertion of single bicortical screws were compared between the variable pitch and standard locking screws at increasing levels of torque. The specimens tested were distal tibiae having a simulated longitudinal fracture. Additionally, fibulae were osteotomized to create a stable longitudinal fracture pattern and were fixed with a 5-screw plate construct with either all variable pitch or all standard locking screws. One of the 5 screws was placed across the osteotomy without lagging. Fibulae were tested cyclically with axial with torsional loading to compare displacements, rotation, and loads at failure or tested in 4-point bending to compare construct stiffness and maximum force to failure. RESULTS: Interfragmentary and plate-bone compression forces in the distal tibia model varied across specimens but were significantly higher with variable pitch locking screws compared with standard locking screws [512 N (SD = 324 N) vs. 79 N (SD = 64 N), P = 0.002, and 242 N (SD = 119 N) vs. 104 N (SD = 123 N), P = 0.028, respectively]. In cyclic loading of fibula constructs, no significant differences were detected in construct axial displacement or angular displacement (P > 0.05). In 4-point bending, no differences were detected in maximum force or bending stiffness (P > 0.05). CONCLUSIONS: Variable pitch locking screws produced interfragmentary compression between cortices and plate-bone compression that was greater than that produced by standard locking screws. In a stable bicortical fibula fixation scenario under external loading, the stability of variable pitch locking screw constructs was similar to constructs with standard locking screws.


  • Open Access

    Mechanically compliant locking plates for diaphyseal fracture fixation: A biomechanical study

    by Connor Huxman, Gregory Lewis, April Armstrong, Gary Updegrove, Zachary Koroneos, Jared Butler

    Axial micromotion between bone fragments can stimulate callus formation and fracture healing. In this study, we propose a novel mechanically compliant locking plate which achieves up to 0.6 mm of interfragmentary motion as flexures machined into the plate elastically deflect under physiological load. We investigated the biomechanical performance of three compliant plate variations in comparison to rigid control plates with small and large working lengths in a comminuted bridge plating scenario using humeral diaphysis surrogates. Under static axial loading, average interfragmentary motion was 6 times larger at 100 N (0.38 vs. 0.05 mm) and nearly three times larger at 350 N (0.58 vs. 0.2 mm) for compliant plates than rigid plates, respectively. Compliant plates delivered between 2.5 and 3.4 times more symmetric interfragmentary motion than rigid plates (p < 0.01). The bi‐phasic stiffness of compliant pates provided 74%–96% lower initial axial stiffness up to approximately 100 N (p < 0.01), after which compliant plate stiffness was similar to rigid plates with increased working length (p > 0.3). The strength to failure of compliant plates under dynamic loading was on average 48%–55% lower than rigid plate groups (p < 0.01); however, all plates survived cyclic fatigue loading of 100,000 cycles at 350 N. This work characterizes the improvement in interfragmentary motion and the reduction in strength to failure of compliant plates compared to control rigid plates. Compliant plates may offer potential in comminuted fracture healing due to their ability to deliver symmetric interfragmentary motion into the range known to stimulate callus formation while surviving moderate fatigue loading with no signs of failure.


  • Open Access

    Biomechanics of fracture healing: how best to optimize your construct in the OR

    by Michael Hast, Vaida Glatt, Michael Archdeacon, Eric Ledet, Gregory Lewis, Jaimo Ahn, Justin Haller

    Orthopaedic surgeons routinely assess the biomechanical environment of a fracture to create a fixation construct that provides the appropriate amount of stability in efforts to optimize fracture healing. Emerging concepts and technologies including reverse dynamization, “smart plates” that measure construct strain, and FractSim software that models fracture strain represent recent developments in optimizing construct biomechanics to accelerate bone healing and minimize construct failure.