Latest Publications

  • Open Access

    Electromyography Frequency Spectrum Is a Better Indicator of Sleep Bruxism Severity Related to Temporomandibular Disorder Pain Than Conventional Masticatory Muscle Activation and Bruxism Time Indices—A Pilot Study

    by Minna Pitkänen, Miro Rytkönen, Tomi Miettinen, Jari Ahlberg, Frank Lobbezoo, Katja Myllymaa, Juha Töyräs, Timo Leppänen, Sami Myllymaa

    Sleep bruxism (SB) has been reportedly associated with temporomandibular disorder (TMD); however, solid evidence is lacking. Previous studies have primarily used traditional metrics, such as the masticatory muscle activity (MMA) index and bruxism time index (BTI) to investigate the link between SB and TMD. However, we aimed to examine how the electromyography (EMG) frequency spectrum is associated with TMD in SB participants. We hypothesised that the EMG signal frequencies during MMA events would be lower in SB participants with TMD pain compared to those without TMD pain. In this exploratory study, we retrospectively analysed home polysomnography data from 44 participants who indicated possible SB. The median signal frequencies and absolute power were calculated using the Fast Fourier Transform of the EMG signals during MMA events. Moreover, the MMA index and BTI were calculated, and all parameters were compared between SB participants with and without TMD pain. The results showed that the absolute power and median frequencies were significantly lower in SB participants with TMD pain compared to those without TMD pain ( p < 0.05), whereas the MMA index and BTI did not differ between the groups ( p > 0.05). These findings suggest that masticatory muscles are getting fatigued in TMD participants with SB and therefore, EMG frequency‐based analysis may provide a promising direction for future assessment of TMD consequences of SB. However, these preliminary results should be validated in future studies involving a larger and more heterogeneous pool of participants.

  • Open Access

    Corrections to “An In-Laboratory Comparison of FocusBand EEG Device and Textile Electrodes Against a Medical-Grade System and Wet Gel Electrodes”

    by Matias Rusanen, Sami Myllymaa, Laura Kalevo, Katja Myllymaa, Juha Töyräs, Timo Leppänen, Samu Kainulainen

    In the above article [1] , Table 2 partially showed erroneous values for the absolute skin-electrode impedances while the correct median absolute impedances were presented in Figure 2. The authors regret the error and apologize for the possible inconvenience. The corrected Table 2 is presented below.

  • Open Access

    Generalizable Deep Learning-Based Sleep Staging Approach for Ambulatory Textile Electrode Headband Recordings

    by Matias Rusanen, Riku Huttunen, Henri Korkalainen, Sami Myllymaa, Juha Töyräs, Katja Myllymaa, Sigridur Sigurdardottir, Kristin A. Olafsdottir, Timo Leppänen, Erna S. Arnardottir, et al.

    Reliable, automated, and user-friendly solutions for the identification of sleep stages in home environment are needed in various clinical and scientific research settings. Previously we have shown that signals recorded with an easily applicable textile electrode headband (FocusBand, T 2 Green Pty Ltd) contain characteristics similar to the standard electrooculography (EOG, E1–M2). We hypothesize that the electroencephalographic (EEG) signals recorded using the textile electrode headband are similar enough with standard EOG in order to develop an automatic neural network-based sleep staging method that generalizes from diagnostic polysomnographic (PSG) data to ambulatory sleep recordings of textile electrode-based forehead EEG. Standard EOG signals together with manually annotated sleep stages from clinical PSG dataset ( n = 876) were used to train, validate, and test a fully convolutional neural network (CNN). Furthermore, ambulatory sleep recordings including a standard set of gel-based electrodes and the textile electrode headband were conducted for 10 healthy volunteers at their homes to test the generalizability of the model. In the test set ( n = 88) of the clinical dataset, the model's accuracy for 5-stage sleep stage classification was 80% (κ = 0.73) using only the single-channel EOG. The model generalized well for the headband-data, reaching 82% (κ = 0.75) overall sleep staging accuracy. In comparison, accuracy of the model was 87% (κ = 0.82) in home recordings using the standard EOG. In conclusion, the CNN model shows potential on automatic sleep staging of healthy individuals using a reusable electrode headband in a home environment.


  • Open Access

    Self-Applied Electrode Set Provides a Clinically Feasible Solution Enabling EEG Recording in Home Sleep Apnea Testing

    by Laura Kalevo, Tomi Miettinen, Akseli Leino, Susanna Westeren-Punnonen, Johanna Sahlman, Esa Mervaala, Juha Toyras, Timo Leppanen, Sami Myllymaa, Katja Myllymaa

    Home sleep apnea testing (HSAT) without electroencephalography (EEG) recording is increasingly used as an alternative to in-laboratory polysomnography for the diagnosis of obstructive sleep apnea (OSA). However, without EEG, electrooculography (EOG), and chin electromyography (EMG) recordings, the OSA severity may be significantly underestimated. Although several ambulatory EEG systems have been recently introduced, no patient-applied systems including EEG, EOG, and chin EMG suitable for home polysomnography are currently in clinical use. We have recently developed and pre-clinically tested a self-applied ambulatory electrode set (AES), consisting of frontal EEG, EOG, and EMG, in subjects with possible sleep bruxism. Now, in this clinical feasibility study, we investigated the signal scorability and usability of the AES as a self-administered sleep assessment approach supplementing the conventional HSAT device. We also investigated how the diagnostic parameters and OSA severity changed when utilizing the AES. Thirty-eight patients (61 % male, 25–78 years) with a clinical suspicion of OSA conducted a single-night, self-administered HSAT with a portable polysomnography device (Nox A1, Nox Medical, Reykjavik, Iceland) supplemented with AES. Only one AES recording failed. The use of AES signals in data analysis significantly affected the median apnea-hypopnea index (AHI), increasing it from 9.4 to 12.7 events/h ( $p < 0.001$ ) compared to the conventional HSAT. Also, in eight patients, the OSA severity class changed to one class worse. Perceived ease of use was well in line with that previously found among healthy volunteers. These results suggest that the AES provides an easy, clinically feasible solution to record EEG as a part of conventional HSAT.


  • Open Access

    Deep Learning Enables Accurate Automatic Sleep Staging Based on Ambulatory Forehead EEG

    by Akseli Leino, Henri Korkalainen, Laura Kalevo, Sami Nikkonen, Samu Kainulainen, Alexander Ryan, Brett Duce, Kirsi Sipila, Jari Ahlberg, Johanna Sahlman, et al.

    We have previously developed an ambulatory electrode set (AES) for the measurement of electroencephalography (EEG), electrooculography (EOG), and electromyography (EMG). The AES has been proven to be suitable for manual sleep staging and self-application in in- home polysomnography (PSG). To further facilitate the diagnostics of various sleep disorders, this study aimed to utilize a deep learning-based automated sleep staging approach for EEG signals acquired with the AES. The present neural network architecture comprises a combination of convolutional and recurrent neural networks previously shown to achieve excellent sleep scoring accuracy with a single standard EEG channel (F4-M1). In this study, the model was re- trained and tested with 135 EEG signals recorded with AES. The recordings were conducted for subjects suspected of sleep apnea or sleep bruxism. The performance of the deep learning model was evaluated with 10-fold cross-validation using manual scoring of the AES signals as a reference. The accuracy of the neural network sleep staging was 79.7% ( $\kappa =0.729$ ) for five sleep stages (W, N1, N2, N3, and R), 84.1% ( $\kappa =0.773$ ) for four sleep stages (W, light sleep, deep sleep, R), and 89.1% ( $\kappa =0.801$ ) for three sleep stages (W, NREM, R). The utilized neural network was able to accurately determine sleep stages based on EEG channels measured with the AES. The accuracy is comparable to the inter-scorer agreement of standard EEG scorings between international sleep centers. The automatic AES-based sleep staging could potentially improve the availability of PSG studies by facilitating the arrangement of self-administrated in- home PSGs.


  • Open Access

    Technical Performance of Textile-Based Dry Forehead Electrodes Compared With Medical-Grade Overnight Home Sleep Recordings

    by Matias Rusanen, Samu Kainulainen, Henri Korkalainen, Laura Kalevo, Katja Myllymaa, Timo Leppanen, Juha Juha Töyräs, Erna Sif Arnardottir, Sami Myllymaa

    The current clinically used electroencephalography (EEG) sensors are not self-applicable. This complicates the recording of the brain’s electrical activity in unattended home polysomnography (PSG). When EEG is not recorded, the sleep architecture cannot be accurately determined, which decreases the accuracy of home-based diagnosis of sleep disorders. The aim of this study was to compare the technical performance of FocusBand, an easily applicable textile electrode headband, to that of clinical EEG and electrooculography (EOG) electrodes. Overnight unattended recordings were conducted at participants’ ( $n =10$ ) homes. Signals were recorded using a portable Nox A1 PSG device. The FocusBand’s forehead EEG (Fp1-Fp2) signals contained features that are visible at both, the standard EEG (F4-M1) and EOG (E1-M2) signals. The FocusBand’s EEG signal amplitudes were significantly lower compared to standard EEG (F4-M1; average difference 98%) and EOG (E1-M2; average difference 29%) signals during all sleep stages. Despite the amplitude difference, forehead EEG signals displayed typical EEG characteristics related to certain sleep stages. However, the frequency content of the FocusBand-based signals was more similar to that of the standard EOG signals than that of standard EEG signals. The majority of the artifacts seen in the FocusBand signals were related to a loosened headband. High differences in the frequency content of the compared signals were also found during wakefulness, suggesting susceptibility of the textile electrodes to electrode movement artifacts. This study demonstrates that the forehead biopotential signals recorded using an easily attachable textile electrode headband could be useful in home-based sleep recordings.


  • Open Access

    An In-Laboratory Comparison of FocusBand EEG Device and Textile Electrodes Against a Medical-Grade System and Wet Gel Electrodes

    by Matias Rusanen, Sami Myllymaa, Laura Kalevo, Katja Myllymaa, Juha Töyräs, Timo Leppänen, Samu Kainulainen

    In this study, FocusBand (FocusBand Technologies, T 2 Green Pty Ltd.) textile electrodes were tested against medical-grade wet electrodes to investigate the possible differences in skin-electrode interface behavior and EEG signals’ quality. In vivo electrical impedance spectroscopy and simultaneous forehead EEG measurements were performed with ten healthy subjects. In addition, the FocusBand device was tested in a stand-alone manner against a medical-grade reference system using similar test measurements. Compared to wet electrodes, textile electrodes had higher median absolute skin-electrode impedances five minutes after the attachment, but this difference decreased to 50–55 % of the initial during the first 60 minutes on all measured frequencies (1–1000 Hz). Textile and wet electrodes produced highly consistent EEG signals at forehead Fp1 and Fp2 locations. From those, Fp1 signals were more consistent in terms of normalized cross-correlations and agreement of the relative spectral powers. A stand-alone comparison showed that the FocusBand device can be used to record forehead biopotential signals, but the quality was not as consistent as with the medical-grade system. Based on impedance characteristics, a recording made using FocusBand textile electrodes may be more susceptible to artifacts than recording made using the medical-grade wet electrodes. However, FocusBand textile electrodes can be used, after a short stabilization period, to reliably record forehead EEG signals with a quality almost equal to that reached with medical-grade wet electrodes.


  • Open Access

    Improved Sweat Artifact Tolerance of Screen-Printed EEG Electrodes by Material Selection-Comparison of Electrochemical Properties in Artificial Sweat

    by Laura Kalevo, Tomi Miettinen, Akseli Leino, Samu Kainulainen, Katja Myllymaa, Juha Toyras, Timo Leppanen, Sami Myllymaa, Juha Tvyrds

    The accurate diagnosis of sleep disorders requires an electroencephalography (EEG) recording. However, in-home EEG sleep monitoring has been hindered by the present cumbersome electrode systems which are impractical for patient self-application. To overcome this shortcoming, we recently introduced a self-applicable facial electrode set with screen-printed EEG electrodes. However, one remaining challenge in overnight EEG measurements is the presence of a low-frequency sweat artifact commonly occurring in sleep recordings. Here, the purpose was to improve the electrochemical properties of the electrodes so that they are more sweat tolerant. We selected three commercial Ag and Ag/AgCl inks (manufactured by Dupont, PPG, and ECM) for the fabrication of screen-printed electrode sets with differently shaped ink layers and compared their electrochemical properties. The open circuit potential and electrical impedance spectroscopy measurements were conducted in a custom-made electrochemical cell filled first with physiological saline and then with artificial sweat. Based on our measurements, the Ag/AgCl layer on top (i.e. in contact with the solution) mainly determines the electrochemical characteristics whereas the Ag layer underneath plays only a minor role. In artificial sweat, the ECM electrodes possessed the most satisfactory properties being very stable with the most reproducible impedance characteristics (standard deviations were significantly (p<0.05) lower than the PPG and DUPONT electrodes). This study demonstrates that the screen-printing technique is suitable for the production of highly reproducible EEG electrodes with high stability and adequate impedance characteristics. However, careful selection of ink materials is essential due to the observed differences in their electrochemical stabilities in artificial sweat.