PSPaul S. Sheeran

Paul S. Sheeran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paul S. Sheeran has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Synthesis and Characterization of Multi-Modal Phase-Change Porphyrin Droplets

    by Kimoon Yoo, Alexander Dhaliwal, Juan Chen, Paul S. Sheeran, Gang Zheng

    Phase-change droplets are a class of ultrasound contrast agents that can convert into echogenic microbubbles in situ with the application of sufficient acoustic energy. Droplets are smaller and more stable than their microbubble counterparts. However, traditional ultrasound contrast agents are not trackable beyond acoustic feedback measurements, which makes quantifying contrast agent bio-distribution or accumulation ex vivo difficult. Researchers may have to rely on fluorescent or optically absorbent companion diagnostic particles to infer bio-distribution. The purpose of this protocol is to detail steps for creating multi-modal phase-change porphyrin droplets using a condensation method. Porphyrins are fluorescent molecules with distinct absorbance bands that can be conjugated onto lipids and incorporated into droplets to extend droplet versatility, enabling more robust bio-distribution while retaining acoustic properties. Seven formulations with varying porphyrin-lipid and base lipid contents were made to investigate microbubble and droplet size distributions. Characterizations suited to porphyrin-containing structures are also described in the protocol to demonstrate their analytic versatility in-solution. Sizing showed that the post-condensed mean diameters were 1.72 to 2.38 times smaller than precursor populations. Absorbance characterization showed intact assemblies had a Q-band peak of 700 nm while disrupted samples had an absorbance peak at 671 nm. Fluorescence characterization showed intact 30% porphyrin-lipid assemblies were fluorescently quenched (>97%), with fluorescence recovery achieved upon disruption. Acoustic vaporization showed that porphyrin droplets were non-echogenic at lower pressures and could be converted into echogenic microbubbles with sufficient pressures. These characterizations show the potential for porphyrin droplets to eliminate the need for absorbance or fluorescence-based companion diagnostic strategies to quantify ultrasound contrast agent bio-distribution for delivery or therapeutic applications in vivo or ex vivo.

  • Optimization of Phase-Change Contrast Agents for Targeting MDA-MB-231 Breast Cancer Cells

    by Kyle P. Hadinger, Joseph P. Marshalek, Paul S. Sheeran, Paul A. Dayton, Terry O. Matsunaga


  • Impact of Encapsulation on in vitro and in vivo Performance of Volatile Nanoscale Phase-Shift Perfluorocarbon Droplets

    by Kimoon Yoo, Wesley R. Walker, Ross Williams, Charles Tremblay-Darveau, Peter N. Burns, Paul S. Sheeran


  • 3-D Perfusion Imaging Using Principal Curvature Detection Rendering

    by Charles Tremblay-Darveau, Paul S. Sheeran, Cindy Kim Vu, Ross Williams, Matthew Bruce, Peter N. Burns

    Three-dimensional contrast-enhanced ultrasound (CEUS) imaging presents a clear advantage over its 2D counterpart in detecting and characterizing suspicious lesions as it properly surveys the inherent heterogeneity of tumours. However, 3D CEUS is also slow compared to 2D CEUS and tends to undersample the microbubble wash-in. This makes it difficult to resolve the feeding vessels, an important oncogenic marker, from the background perfusion cloud. Contrast-enhanced Doppler is helpful in isolating this conduit flow, but requires too many pulses in conventional line-by-line beamforming design. Recent breakthroughs in plane-wave imaging have greatly accelerated the volumetric imaging frame rate, but volumetric Doppler angiography still remains challenging when considering realtime limitations on the Doppler ensemble length. In this work, we demonstrate the feasibility of volumetric CEUS angiography subjected to real-time imaging constraints. Namely, we show how principal curvature detection can significantly improve 3D rendering of relatively noisy ultrasound angiograms without degrading the spatial resolution while subjected to a reasonable Doppler ensemble size. Singular Value Decomposition is also shown to be capable of identifying the quasi-stationary capillary perfusion.


  • The Role of Microbubble Echo Phase Lag in Multipulse Contrast-Enhanced Ultrasound Imaging

    by Charles Tremblay-Darveau, Paul S. Sheeran, Cindy Kim Vu, Ross Williams, Ze Zhang, Matthew Bruce, Peter N. Burns

    In this paper, we assess the importance of microbubble shell composition for contrast-enhanced imaging sequences commonly used on clinical scanners. While the gas core dynamics are primarily responsible for the nonlinear harmonic response of microbubbles at diagnostic pressures, it is now understood that the shell rheology plays a dominant role in the nonlinear response of microbubbles subjected to low acoustic pressures. Of particular interest here, acoustic pressures of tens of kPa can cause a reversible phase transition of the phospholipid coatings from a stiff elastic organized state, to a less stiff, disorganized buckled state. Such a transition from an elastic to buckled shell induces a steep variation of the shell elasticity, which alters the microbubble acoustic scattering properties. We demonstrate in this work that this mechanism plays a dominant role in contrast pulse sequences that modulate the amplitude of the insonifying pulse pressure. The contrast-to-tissue ratio for amplitude modulation (AM), pulse inversion (PI) and amplitude modulation pulse inversion (AMPI) is measured in vitro for Definity, Sonazoid, both lipid-encapsulted microbubbles, and the albumin-coated Optison. It is found that pulse sequences using amplitude modulation significantly enhanced the nonlinear response of all studied microbubbles compared to pulse inversion (up to 15 dB more) when low insonation pressures under 200kPa were used. Further investigation reveals that the origin of the hyper-echoicity is a small phase lag occurring between the echoes from the full and half amplitude driving pulses, and that the effect could be attributed to the shell-softening dynamics of lipid and albumin coating. We assess that this additional phase in microbubble ultrasound scattering can have a dominant role in the contrastto- tissue ratio achieved in contrast sequences using amplitude modulation. We also show that the pressure dependent phase lag is a specific marker for microbubbles, with no equivalent in tissue, which can be used to segment microbubbles from tissue harmonics and significantly increase the CTR.


  • More Than Bubbles: Creating Phase-Shift Droplets from Commercially Available Ultrasound Contrast Agents

    by Paul S. Sheeran, Kimoon Yoo, Ross Williams, Melissa Yin, F. Stuart Foster, Peter N. Burns


  • Open Access

    Methods of Generating Submicrometer Phase-Shift Perfluorocarbon Droplets for Applications in Medical Ultrasonography

    by Paul S. Sheeran, Naomi Matsuura, Mark A. Borden, Ross Williams, Terry O. Matsunaga, Peter N. Burns, Paul A. Dayton

    Continued advances in the field of ultrasound and ultrasound contrast agents have created new approaches to imaging and medical intervention. Phase-shift perfluorocarbon droplets, which can be vaporized by ultrasound energy to transition from the liquid to the vapor state, are one of the most highly researched alternatives to clinical ultrasound contrast agents (i.e., microbubbles). In this paper, part of a special issue on methods in biomedical ultrasonics, we survey current techniques to prepare ultrasound-activated nanoscale phase-shift perfluorocarbon droplets, including sonication, extrusion, homogenization, microfluidics, and microbubble condensation. We provide example protocols and discuss advantages and limitations of each approach. Finally, we discuss best practice in characterization of this class of contrast agents with respect to size distribution and ultrasound activation.


  • Concepts and Tradeoffs in Velocity Estimation With Plane-Wave Contrast-Enhanced Doppler

    by Charles Tremblay-Darveau, Ross Williams, Paul S. Sheeran, Laurent Milot, Matthew Bruce, Peter N. Burns

    While long Doppler ensembles are, in principle, beneficial for velocity estimates, short acoustic pulses must be used in microbubble contrast-enhanced (CE) Doppler to mitigate microbubble destruction. This introduces inherent tradeoffs in velocity estimates with autocorrelators, which are studied here. A model of the autocorrelation function adapted to the microbubble Doppler signal accounting for transit time, the echo frequency uncertainty, and contrast-agent destruction is derived and validated in vitro. It is further demonstrated that a local measurement of the center frequency of the microbubble echo is essential in order to avoid significant bias in velocity estimates arising from the linear and nonlinear frequency-dependent scattering of microbubbles and compensate for the inherent speckle nature of the received echo frequency. For these reasons, broadband Doppler estimators (2-D autocorrelator and Radon projection) are better suited than simpler narrow-band estimators (1-D autocorrelator and 1-D Fourier transform) for CE flow assessment. A case study of perfusion in a VX-2 carcinoma using CE plane-wave Doppler is also shown. We demonstrate that even when considering all uncertainties associated with microbubble-related decorrelation (destruction, pulse bandwidth, transit time, and flow gradient) and the need for real-time imaging, a coefficient of variation of 4% on the axial velocity is achievable with plane-wave imaging.


  • Image-Guided Ultrasound Characterization of Volatile Sub-Micron Phase-Shift Droplets in the 20–40 MHz Frequency Range

    by Paul S. Sheeran, Yasaman Daghighi, Kimoon Yoo, Ross Williams, Emmanuel Cherin, F. Stuart Foster, Peter N. Burns


  • Open Access

    High-intensity focused ultrasound ablation enhancement in vivo via phase-shift nanodroplets compared to microbubbles

    by Linsey C. Moyer, Kelsie F. Timbie, Paul S. Sheeran, Richard J. Price, G. Wilson Miller, Paul A. Dayton

    During high-intensity focused ultrasound (HIFU) surgical procedures, there is a need to rapidly ablate pathological tissue while minimizing damage to healthy tissue. Current techniques are limited by relatively long procedure times and risks of off-target heating of healthy tissue. One possible solution is the use of microbubbles, which can improve the efficiency of thermal energy delivery during HIFU procedures. However, microbubbles also suffer from limitations such as low spatial selectivity and short circulation time in vivo. In this study, the use of a dual-perfluorocarbon nanodroplet that can enhance thermal ablation, yet retains high spatial selectivity and circulation half-life, was evaluated in vivo and compared to traditional microbubble agents during HIFU ablations of rat liver. High-intensity focused ultrasound (1.1 MHz, 4.1 MPa, 15-s continuous wave) was applied to rat liver in vivo, and heating was monitored during sonication by magnetic resonance thermometry. Thermometry data were analyzed to quantify temperature rise and ablated area, both at the target and prefocally, for HIFU applied 5, 15, or 95 min after intravenous injection of either nanodroplet or microbubble agents. Sham control experiments (no injected agents) were also performed. At all three time points, nanodroplets significantly enhanced thermal delivery to the target, achieving temperatures 130 % higher and ablated areas 30 times larger than no-agent control sonications. Nanodroplets did not significantly enhance off-target surface heating. Microbubbles also resulted in significantly greater thermal delivery, but heating was concentrated at the proximal surface of the animal, causing skin burns. Furthermore, microbubbles resulted in lower thermal delivery to the desired target than even the control case, with the notable exception of the 95-min time point. Results indicate that the nanodroplet formulation studied here can substantially increase thermal delivery at the acoustic focus while avoiding prefocal heating. In contrast, microbubbles resulted in greater prefocal heating and less heating at the target. Furthermore, nanodroplets are sufficiently stable to enhance HIFU ablation in vivo for at least 1.5 h after injection. The use of a dual-perfluorocarbon nanodroplet formulation as described herein could substantially reduce HIFU procedure times without increasing the risk of skin burns.