AVAniketh Venkataram

Aniketh Venkataram

*This is an algorithmically generated author record based on publicly available information.

Aniketh Venkataram has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Rajashekara Babu

    Department of General Surgery, Bangalore Medical College and Research Institute, No. 182, 100 Feet Ring Road, Banashankari 3rd Stage, Bangalore 560085, India

    4 shared publications
  • Sadashivaiah Shivaswamy

    Department of General Surgery, Bangalore Medical College and Research Institute, No. 182, 100 Feet Ring Road, Banashankari 3rd Stage, Bangalore 560085, India

    4 shared publications
  • Shivashankar Santhosh

    Department of General Surgery, Bangalore Medical College and Research Institute, No. 182, 100 Feet Ring Road, Banashankari 3rd Stage, Bangalore 560085, India

    4 shared publications
  • Deeksha Rao

    Bangalore, India

    3 shared publications
  • Sunderraj Ellur

    Department of Plastic Surgery, St. Johns Medical College, Bangalore, India

    3 shared publications
  • Venkataram Mysore

    Bangalore, India

    3 shared publications

Latest Publications

  • Open Access

    A Component-Based Approach to Deviated Nose Correction: The SAT (Shape Axis Tilt) System

    by Aniketh Venkataram

    Correspondence: Aniketh Venkataram (E-mail: anikethv@gmail.com) Abstract Background Deviated or crooked nose correction represents one of the hardest challenges in all of plastic surgery. The surgery often involves functional correction as well as cosmetic. While the term deviated is used as an umbrella term, this can include several varieties, each of which requires to be tackled uniquely. While several classifications for deviated nose exist, many are complicated and do not correlate with the surgical maneuvers required for their correction. Methodology Patient records were reviewed retrospectively for age, sex, technique used, results, and patient satisfaction. All procedures were done with open rhinoplasty. Results Deviated noses were analyzed in terms of deviations of shape (S), deviation of longitudinal axis (A), and deviation of vertical tilt (T), also known as the SAT system. These were further prioritized in terms of the primary deformity and secondary deformities. Each of these components required unique surgical maneuvers. These included spreader grafts, overlapping, caudal resection, and bony excisions. Maneuvers were classified as corrective and camouflage. Conclusion Rhinoplasty is a fascinating surgery where multiple roads can lead to the same destination. Deviated noses represent a unique challenge in their complexity and variety. With our component-based system, we hope to ease this difficult challenge. Keywords: deviated nose correction, shape axis tilt system, crooked nose, open rhinoplasty Article published online: 10 November 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

  • Open Access

    Migraine Surgery in India: Early Experience and Outcomes from a Pioneering Surgical Series

    by Aniketh Venkataram, Mihir Shankar

    Correspondence: Aniketh Venkataram (E-mail: anikethv@gmail.com) Abstract Background Chronic migraine remains a debilitating condition affecting a significant proportion of the population, with limited success from conventional medical therapies in many cases. Migraine surgery, targeting peripheral trigger sites, has emerged as an effective surgical option in select patients. Despite its growing global acceptance, this approach remains virtually unexplored in India. We report the first clinical series of migraine surgery performed in India, highlighting its feasibility, safety, and early outcomes. Methodology A prospective series of eight patients with chronic, refractory migraine headaches underwent peripheral nerve decompression surgery between 2023 and 2025. All patients were carefully selected based on a thorough neurological evaluation and consistent trigger site identification. Surgical decompression was performed at the supraorbital and/or temporal trigger sites under general anesthesia. Postoperative follow-up ranged from 6 to 18 months, with outcomes assessed using patient-reported frequency, intensity, and duration of headaches. Results Of the eight patients operated on, seven (87.5%) reported significant improvement in their migraine symptoms, including reduced headache frequency and severity. One patient (12.5%) experienced mild improvement. There were no surgical complications or adverse events in any case. All patients tolerated the procedure well, and postoperative recovery was uneventful. Discussion This initial experience demonstrates that migraine surgery is a feasible and safe option for selected patients in the Indian clinical setting. The outcomes are consistent with international data, underscoring the potential of this procedure to offer durable relief to patients with chronic, treatment-resistant migraine. As the first surgical team in India to adopt and perform migraine surgery, we hope to catalyze broader awareness and interest in this field. Keywords: migraine surgery, chronic migraine, peripheral nerve decompression, peripheral trigger sites Article published online: 10 November 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

  • Open Access

    Combined supraperiosteal microfat grafting and intradermal nanofat for the treatment of periorbital melanosis (dark circles)

    by Aniketh Venkataram

    Objectives: Dark circles are one of the most common aesthetic concerns in India. While several treatment options exist, none address both volume deficiency and skin quality simultaneously. We felt that fat grafting and nanofat provided a novel treatment option to address both aspects of dark circles in one treatment. Material and Methods: Patient records were examined from 2017 to 2021. A total of 28 patients were identified as having undergone fat grafting and nanofat for dark circles specifically. The patients were analyzed for age, gender, volumes injected, and outcomes based on patient self-assessment. Results: A total of 36 patients underwent fat grafting ranging from the age of 20 to 40 (average 31). All procedures were done under local anesthesia as day care procedures. The volumes injected range from 2 cc/side to 8 cc/side, with an average of 4.36 cc. Using the Likert scale, 28 (77%) rated their results as very satisfied. Six (17%) rated it as satisfied. One rated it as neutral and two rated it as average, and underwent a second session of fat grafting where another 2 cc was injected per side. Conclusion: Fat grafting and nanofat are an exciting treatment option for the treatment of dark circles, which is usually regarded as a recalcitrant problem. It has the advantages of addressing both volume and skin quality, being a single-stage procedure, and producing comparatively long-lasting results.


  • Understanding the Relationship between Torque, Rotational Speed (RPM), and Tissue Characteristics in Follicular Unit Excision Harvest

    by Aniketh Venkataram, Venkataram Mysore, Deeksha Rao

    Introduction: The aim of follicular unit excision (FUE) is to harvest grafts without transection. To date, the effect of motor dynamics such as torque and revolutions per minute (RPM) on harvest success has not been studied; therefore, we chose to study the effect of torque and RPM variation on FUE graft harvest. Materials & Methods: We analysed hair diameter and skin laxity on 40 patients prior to surgery. Patients were randomized into two groups. In the first group of 20, RPM was fixed and torque varied; in the second group of 20, it was the opposite and RPM was varied and torque fixed. Grafts were harvested at each setting and analysed for transection, and the time of harvesting was noted. This was correlated with hair diameter and skin laxity. Results: At high laxity, low torque was required. As the laxity reduced, higher torque was needed to overcome the resistance. Torque had a minimum value required based on the tissue resistance for the harvest to be viable. It was found that increasing RPM increased the speed of harvest. The maximum RPM tolerated before transection rate was unacceptable was proportional to the hair diameter. Discussion: Energy spent is a product of torque and RPM. Torque is the minimum force needed to drill through the surface. RPM is the speed at which the drill rotates. Our energy expended should be lower than the energy needed to damage the graft. Our recommendation is to keep the torque as low as needed: the greater the skin laxity, lower the torque needed. Additionally, we recommend keeping the RPM as high as possible to increase the speed of the harvest without leading to unacceptable levels of transection: the higher the hair diameter, the higher the RPM tolerated. With these manipulations, a successful harvest would be possible in nearly all cases.

  • Mechanics of Follicular Unit Excision: Understanding the Role of Torque and Angular Velocity in Optimizing Graft Harvest

    by Aniketh Mbbs Venkataram, Venkataram MBBS. DVD. DNB. M.D. DipRCPath (LOND) FRCP(Glasgow) Mysore, Deeksha Mbbs Rao, Sajin Mbbs Alexander, Sandeep Makam

    An abstract is unavailable. This article is available as a PDF only.


  • Enhancing Patient Outcomes in Aesthetic Breast Implant Procedures Using Proven Antimicrobial Breast Pocket Irrigations: A 20-Year Follow-up

    by Aniketh Venkataram, Nicholas Lahar, William P Adams

    Background: Capsular contracture (CC) remains the most common complication of implant-based aesthetic and reconstructive breast surgery. With subclinical infection proven to be the primary etiology, antimicrobial breast pocket irrigation has been recommended as the key step to reduce CC but has not been universally adopted.Objectives: The purpose of this study was to review the rates of CC observed when applying proven antimicrobial breast pocket irrigations.Methods: Data from patients undergoing cosmetic breast augmentation were recorded prospectively from 1997 to 2017. The irrigation was performed with either a Betadine-containing (50% Betadine or “Betadine triple”) or a non-Betadine triple antibiotic regimen. The database was assessed to determine the type of implant used, the incidence of CC, and possible contributing factors. The degree of CC was recorded according to the Baker classification.Results: A 20-year prospective data collection yielded 2088 patients with 4176 implants; of these patients, 826 had textured implants and 1262 had smooth implants. The incidence of Grade III/IV CC was found to be 0.57% in all patients undergoing primary breast augmentation (1.21% in textured implants and 0.16% in smooth implants).Conclusions: This study constitutes the largest and longest review of CC in a controlled, single-surgeon setting. The incidence of CC is low and reinforces the efficacy/utility of antimicrobial breast pocket irrigation. Both the Betadine and non-Betadine antibiotic regimens were found to be effective, with the Betadine regimen being preferred. Universal adoption of Betadine-containing antimicrobial breast pocket irrigation is recommended to reduce CC and other device-associated infections.Level of Evidence: 4:


  • Lagophthalmos after rhinoplasty- a possible complication

    by Aniketh Venkataram, Paul S. Nassif, Brittany A. Leader, Deeksha Rao, Grace L. Peng, Rajeshwari Biradar


  • Open Access

    Beware of the Impostors—Scalp Pathology Primer for the Hair Transplant Surgeon

    by Aniketh Venkataram, Mysore Venkataram

    Histopathological features are important for the practicing hair transplant surgeon to ensure proper case selection, diagnosis, choice of proper treatment, and successful outcome. While the primary focus of the hair transplant surgeon is androgenetic alopecia (AGA), it is important to be aware of other conditions that can mimic AGA, whose treatment may be different. This article outlines some of these conditions such as scarring alopecias, alopecia areata, etc., and how to distinguish them. Proper identification will ensure proper treatment and avoid potential missteps in management.


  • Open Access

    Regenerative Medicine Treatments for Androgenetic Alopecia

    by Venkataram Mysore, Sajin Alexander, Suman Nepal, Aniketh Venkataram

    Regenerative medicine and the role of stem cells are being studied for applications in nearly every field of medicine. The pluripotent nature of stem cells underlies their vast potential for treatment of androgenic alopecia. Several advances in recent years have heightened interest in this field, chief among them are the evolution of simpler techniques to isolate regenerative elements and stems cells. These techniques are easy, outpatient procedures with immediate injection, often single session with harvest, and minimal manipulation (usually physical). This paper seeks to critically review the existing data and determine the current evidence and their role in practice.