Manfred Fuchs
Research Subjects
Manfred Fuchs has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Michael Wagner
Compumedics Neuroscan GmbH, Heussweg 25, 20255 Hamburg, Germany
5 shared publicationsJörn Kastner
Compumedics Neuroscan GmbH, Heussweg 25, 20255 Hamburg, Germany
4 shared publicationsAlfred K. Louis
Institut für Angewandte Mathematik, Universität des Saarlandes
1 shared publication- Felix Darvas
Neurologie, RWTH Aachen
1 shared publication Fernando Gasca
Compumedics Neuroscan GmbH, Heussweg 25, 20255 Hamburg, Germany
1 shared publicationHelmut Buchner
1 shared publication
Latest Publications
- 17 February 2017
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 7 (3) , 185-191
MEG and EEG dipole clusters from extended cortical sources
Data from magnetoencephalography (MEG) and electroencephalography (EEG) suffer from a rather limited signal-to-noise-ratio (SNR) due to cortical background activities and other artifacts. In order to study the effect of the SNR on the size and distribution of dipole clusters reconstructed from interictal epileptic spikes, we performed simulations using realistically shaped volume conductor models and extended cortical sources with different sensor configurations. Head models and cortical surfaces were derived from an averaged magnetic resonance image dataset (Montreal Neurological Institute). Extended sources were simulated by spherical patches with Gaussian current distributions on the folded cortical surface. Different patch sizes were used to investigate cancellation effects from opposing walls of sulcal foldings and to estimate corresponding changes in MEG and EEG sensitivity distributions. Finally, white noise was added to the simulated fields and equivalent current dipole reconstructions were performed to determine size and shape of the resulting dipole clusters. Neuronal currents are oriented perpendicular to the local cortical surface and show cancellation effects of source components on opposing sulcal walls. Since these mostly tangential aspects from large cortical patches cancel out, large extended sources exhibit more radial components in the head geometry. This effect has a larger impact on MEG data as compared to EEG, because in a spherical head model radial currents do not yield any magnetic field. Confidence volumes of single reconstructed dipoles from simulated data at different SNRs show a good correlation with the extension of clusters from repeated dipole reconstructions. Size and shape of dipole clusters reconstructed from extended cortical sources do not only depend on spike and timepoint selection, but also strongly on the SNR of the measured interictal MEG or EEG data. In a linear approximation the size of the clusters is proportional to the inverse SNR.
- 17 February 2017
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 7 (3) , 185-191
MEG and EEG dipole clusters from extended cortical sources
Data from magnetoencephalography (MEG) and electroencephalography (EEG) suffer from a rather limited signal-to-noise-ratio (SNR) due to cortical background activities and other artifacts. In order to study the effect of the SNR on the size and distribution of dipole clusters reconstructed from interictal epileptic spikes, we performed simulations using realistically shaped volume conductor models and extended cortical sources with different sensor configurations. Head models and cortical surfaces were derived from an averaged magnetic resonance image dataset (Montreal Neurological Institute). Extended sources were simulated by spherical patches with Gaussian current distributions on the folded cortical surface. Different patch sizes were used to investigate cancellation effects from opposing walls of sulcal foldings and to estimate corresponding changes in MEG and EEG sensitivity distributions. Finally, white noise was added to the simulated fields and equivalent current dipole reconstructions were performed to determine size and shape of the resulting dipole clusters. Neuronal currents are oriented perpendicular to the local cortical surface and show cancellation effects of source components on opposing sulcal walls. Since these mostly tangential aspects from large cortical patches cancel out, large extended sources exhibit more radial components in the head geometry. This effect has a larger impact on MEG data as compared to EEG, because in a spherical head model radial currents do not yield any magnetic field. Confidence volumes of single reconstructed dipoles from simulated data at different SNRs show a good correlation with the extension of clusters from repeated dipole reconstructions. Size and shape of dipole clusters reconstructed from extended cortical sources do not only depend on spike and timepoint selection, but also strongly on the SNR of the measured interictal MEG or EEG data. In a linear approximation the size of the clusters is proportional to the inverse SNR.
- 1 April 2007
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 24 (2) , 101-119
Development of Volume Conductor and Source Models to Localize Epileptic Foci
There is increasing interest in mapping and source reconstruction from electrocorticoencephalographic (ECoG) grid data and comparison to surface EEG evaluations of epileptic patients. ECoG mapping onto three-dimensional renderings of the individual cortical anatomy derived from magnetic resonance images and computed tomography (CT) is performed after coregistration of anatomical and functional coordinate systems. Source reconstructions from ECoG and EEG are compared using different source models and realistically shaped volume conductor models. Realistically shaped volume conductor models for EEG source reconstruction are a prerequisite for improved localization accuracy. Individual boundary element method (BEM) models derived from MRI represent the "gold standard" and can approximate isotropic homogeneous head compartments and thus give an improved description of the head shape as compared with classical oversimplifying spherical shell models. Anisotropic volume conduction properties of the bone layer or the white matter fibers can be described by the finite element method (FEM); unfortunately, these models require a huge computational effort and are thus not used in daily applications. To avoid this computational effort, head models derived from an averaged MRI dataset can be used. Highly refined models with a large number of nodes and thus better numerical accuracy can be used by this approach, because the setup is performed only once and the decomposed models or precomputed leadfield matrices are saved for later application. Individual image data are not at all needed, if an overlay of the reconstruction results with the anatomy is not desired. With precomputed leadfield matrices and linear interpolation techniques, at least standardized BEM and FEM volume conductor models derived from averaged MRI datasets can achieve the same computational speed as analytical spherical models. The smoothed cortical envelope is used as a realistically shaped single-shell volume conductor model for ECoG source reconstruction, whereas three-compartment BEM-models are required for EEG. The authors describe how to localize ECoG-grid electrode positions and how to segment the cortical surface from coregistered magnetic resonance and CT images. Landmark-based coregistration is performed using common fiducials in both image modalities. Another more promising automatic approach is based on mutual three-dimensional volume gray-level information. The ECoG electrode positions can be retrieved from three-dimensional CT slices manually using cursors in thresholded images with depth information. Alternatively, the smoothed envelope of the cortical surface segmented from the MRI is used to semiautomatically determine the grid electrode positions by marking the four corners and measuring distances along the smoothed surface. With extended source patches for cortically constrained scans and current density reconstructions, results from ECoG and surface EEG data were compared. Single equivalent dipoles were used to explain the EEG far fields, and results were compared with the original current density distributions explaining the ECoG data. The authors studied the performance of spherical and realistically shaped BEM volume conductor models for EEG and ECoG source reconstruction in spherical and nonspherical parts of the head with simulations and measured epileptic spike data. Only small differences between spherical and realistically shaped models were found in the spherical parts of the head, whereas realistically shaped models are superior to spherical approximations in both single-shell ECoG and three-shell EEG cases in the nonspherical parts, such as the temporal lobe areas. The ECoG near field is more complicated to interpret than the surface EEG far field and cannot be explained in general by simple equivalent dipoles. However, from simulations with realistically shaped volume conductor models and cortically constrained source models, the authors studied how the bone and skin layer act as spatial low pass filters that smooth and simplify the surface EEG maps generated by much more complicated-looking source configurations derived from measured ECoG data.
- 1 April 2007
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 24 (2) , 101-119
Development of Volume Conductor and Source Models to Localize Epileptic Foci
There is increasing interest in mapping and source reconstruction from electrocorticoencephalographic (ECoG) grid data and comparison to surface EEG evaluations of epileptic patients. ECoG mapping onto three-dimensional renderings of the individual cortical anatomy derived from magnetic resonance images and computed tomography (CT) is performed after coregistration of anatomical and functional coordinate systems. Source reconstructions from ECoG and EEG are compared using different source models and realistically shaped volume conductor models. Realistically shaped volume conductor models for EEG source reconstruction are a prerequisite for improved localization accuracy. Individual boundary element method (BEM) models derived from MRI represent the "gold standard" and can approximate isotropic homogeneous head compartments and thus give an improved description of the head shape as compared with classical oversimplifying spherical shell models. Anisotropic volume conduction properties of the bone layer or the white matter fibers can be described by the finite element method (FEM); unfortunately, these models require a huge computational effort and are thus not used in daily applications. To avoid this computational effort, head models derived from an averaged MRI dataset can be used. Highly refined models with a large number of nodes and thus better numerical accuracy can be used by this approach, because the setup is performed only once and the decomposed models or precomputed leadfield matrices are saved for later application. Individual image data are not at all needed, if an overlay of the reconstruction results with the anatomy is not desired. With precomputed leadfield matrices and linear interpolation techniques, at least standardized BEM and FEM volume conductor models derived from averaged MRI datasets can achieve the same computational speed as analytical spherical models. The smoothed cortical envelope is used as a realistically shaped single-shell volume conductor model for ECoG source reconstruction, whereas three-compartment BEM-models are required for EEG. The authors describe how to localize ECoG-grid electrode positions and how to segment the cortical surface from coregistered magnetic resonance and CT images. Landmark-based coregistration is performed using common fiducials in both image modalities. Another more promising automatic approach is based on mutual three-dimensional volume gray-level information. The ECoG electrode positions can be retrieved from three-dimensional CT slices manually using cursors in thresholded images with depth information. Alternatively, the smoothed envelope of the cortical surface segmented from the MRI is used to semiautomatically determine the grid electrode positions by marking the four corners and measuring distances along the smoothed surface. With extended source patches for cortically constrained scans and current density reconstructions, results from ECoG and surface EEG data were compared. Single equivalent dipoles were used to explain the EEG far fields, and results were compared with the original current density distributions explaining the ECoG data. The authors studied the performance of spherical and realistically shaped BEM volume conductor models for EEG and ECoG source reconstruction in spherical and nonspherical parts of the head with simulations and measured epileptic spike data. Only small differences between spherical and realistically shaped models were found in the spherical parts of the head, whereas realistically shaped models are superior to spherical approximations in both single-shell ECoG and three-shell EEG cases in the nonspherical parts, such as the temporal lobe areas. The ECoG near field is more complicated to interpret than the surface EEG far field and cannot be explained in general by simple equivalent dipoles. However, from simulations with realistically shaped volume conductor models and cortically constrained source models, the authors studied how the bone and skin layer act as spatial low pass filters that smooth and simplify the surface EEG maps generated by much more complicated-looking source configurations derived from measured ECoG data.
- 1 June 2004
- Published by Elsevier in Clinical Neurophysiology
- Vol. 115 (6) , 1442-1451
Confidence limits of dipole source reconstruction results
- 1 June 2004
- Published by Elsevier in Clinical Neurophysiology
- Vol. 115 (6) , 1442-1451
Confidence limits of dipole source reconstruction results
- 1 February 2004
- Published by Elsevier in Physical Medicine and Rehabilitation Clinics of North America
- Vol. 15 (1) , 251-262
Overview of dipole source localization
- 1 February 2004
- Published by Elsevier in Physical Medicine and Rehabilitation Clinics of North America
- Vol. 15 (1) , 251-262
Overview of dipole source localization
- 1 January 2003
- Published by Springer Nature
- p. 472-482
Spatio-Temporal Current Density Reconstruction from EEG-/MEG-Data
- 1 January 2003
- Published by Springer Nature
- p. 472-482
Spatio-Temporal Current Density Reconstruction from EEG-/MEG-Data
- Top Cited Papers
- 1 May 2002
- Published by Elsevier in Clinical Neurophysiology
- Vol. 113 (5) , 702-712
A standardized boundary element method volume conductor model
- 1 May 2002
- Published by Elsevier in Clinical Neurophysiology
- Vol. 113 (5) , 702-712
Top Cited PapersA standardized boundary element method volume conductor model
- 1 August 2001
- Published by Elsevier in Clinical Neurophysiology
- Vol. 112 (8) , 1400-1407
Boundary element method volume conductor models for EEG source reconstruction
- 1 August 2001
- Published by Elsevier in Clinical Neurophysiology
- Vol. 112 (8) , 1400-1407
Boundary element method volume conductor models for EEG source reconstruction
- 1 January 1999
- Published by Springer Nature
- p. 597-603
Mediziner, Physiker und Ingenieure erforschen Funktionen des Gehirns
- 1 January 1999
- Published by Springer Nature
- p. 597-603
Mediziner, Physiker und Ingenieure erforschen Funktionen des Gehirns
- 1 January 1998
- Published by Springer Nature
- p. 455-459
EEG/MEG Quellen Rekonstruktion