Steven Leuridan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Steven Leuridan has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Kathleen Denis
KU Leuven, Department of Mechanical Engineering, Smart Instrumentation, B-3000 Leuven, Belgium
6 shared publications - Leonard Pastrav
KU Leuven, Department of Mechanical Engineering, Smart Instrumentation, B-3000 Leuven, Belgium
5 shared publications - Quentin Goossens
Georgia Institute of Technology
4 shared publications - Wim Desmet
KU Leuven, Department of Mechanical Engineering, Mecha(tro)nic System Dynamics Section, B-3000 Leuven, Belgium
3 shared publications - Alexander Van Tongel
Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, Ghent, Belgium
2 shared publications Jos Vander Sloten
Department of Mechanical Engineering, Biomechanics Division. KU Leuven, Celestijnenlaan 300c, Box 2419, 3001 Leuven, Belgium
2 shared publications
Latest Publications
- 1 September 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 49 (1) , 109-120
Vibration-based fixation assessment of tibial knee implants: A combined in vitro and in silico feasibility study
The preoperative diagnosis of loosening of cemented tibial knee implants is challenging. This feasibility study explored the basic potential of a vibration-based method as an alternative diagnostic technique to assess the fixation state of a cemented tibia implant and establish the method's sensitivity limits. A combined in vitro and in silico approach was pursued. Several loosening cases were simulated. The largest changes in the vibrational behavior were obtained in the frequency range above 1500 Hz. The vibrational behavior was described with two features; the frequency response function and the power spectral density band power. Using both features, all experimentally simulated loosening cases could clearly be distinguished from the fully cemented cases. By complementing the experimental work with an in silico study, it was shown that loosening of approximately 14% of the implant surface on the lateral and medial side was detectable with a vibration-based method. Proximal lateral and medial locations on the tibia or locations toward the edge of the implant surface measured in the longitudinal direction were the most sensitive measurement and excitation locations to assess implant fixation. These results contribute to the development of vibration-based methods as an alternative follow-up method to detect loosened tibia implants.
- 1 September 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 49 (1) , 109-120
Vibration-based fixation assessment of tibial knee implants: A combined in vitro and in silico feasibility study
The preoperative diagnosis of loosening of cemented tibial knee implants is challenging. This feasibility study explored the basic potential of a vibration-based method as an alternative diagnostic technique to assess the fixation state of a cemented tibia implant and establish the method's sensitivity limits. A combined in vitro and in silico approach was pursued. Several loosening cases were simulated. The largest changes in the vibrational behavior were obtained in the frequency range above 1500 Hz. The vibrational behavior was described with two features; the frequency response function and the power spectral density band power. Using both features, all experimentally simulated loosening cases could clearly be distinguished from the fully cemented cases. By complementing the experimental work with an in silico study, it was shown that loosening of approximately 14% of the implant surface on the lateral and medial side was detectable with a vibration-based method. Proximal lateral and medial locations on the tibia or locations toward the edge of the implant surface measured in the longitudinal direction were the most sensitive measurement and excitation locations to assess implant fixation. These results contribute to the development of vibration-based methods as an alternative follow-up method to detect loosened tibia implants.
- 1 February 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 66, 12-18
Determination of replicate composite bone material properties using modal analysis
- 1 February 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 66, 12-18
Determination of replicate composite bone material properties using modal analysis
- 11 April 2016
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 25 (6) , e156-e165
A nondestructive method to verify the glenosphere-baseplate assembly in reverse shoulder arthroplasty
- 11 April 2016
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 25 (6) , e156-e165
A nondestructive method to verify the glenosphere-baseplate assembly in reverse shoulder arthroplasty
- Open Access
- 25 November 2015
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 10 (1) , 181
Consequences of reaming with flat and convex reamers for bone volume and surface area of the glenoid; a basic science study
The effect of reaming on bone volume and surface area of the glenoid is not precisely known. We hypothesize that (1) convex reamers create a larger surface area than flat reamers, (2) flat reamers cause less bone loss than convex reamers, and (3) the amount of bone loss increases with the amount of version correction. Reaming procedures with different types of reamers are performed on similar-sized uniconcave and biconcave glenoids created from Sawbones foam blocks. The loss of bone volume, the size of the remaining surface area, and the reaming depth are measured and evaluated. Reaming with convex reamers results in a significantly larger surface area than with flat reamers for both uniconcave and biconcave glenoids (p = 0.013 and p = 0.001). Convex reamers cause more bone loss than flat reamers, but the difference is only significant for uniconcave glenoids (p = 0.007). In biconcave glenoids, convex reamers remove a similar amount of bone as flat reamers, but offer a larger surface area while maximizing the correction of the retroversion. In pathological uniconcave glenoids, convex reamers are preferred because of the conforming shape.
- 25 November 2015
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 10 (1) , 181
Open AccessConsequences of reaming with flat and convex reamers for bone volume and surface area of the glenoid; a basic science study
The effect of reaming on bone volume and surface area of the glenoid is not precisely known. We hypothesize that (1) convex reamers create a larger surface area than flat reamers, (2) flat reamers cause less bone loss than convex reamers, and (3) the amount of bone loss increases with the amount of version correction. Reaming procedures with different types of reamers are performed on similar-sized uniconcave and biconcave glenoids created from Sawbones foam blocks. The loss of bone volume, the size of the remaining surface area, and the reaming depth are measured and evaluated. Reaming with convex reamers results in a significantly larger surface area than with flat reamers for both uniconcave and biconcave glenoids (p = 0.013 and p = 0.001). Convex reamers cause more bone loss than flat reamers, but the difference is only significant for uniconcave glenoids (p = 0.007). In biconcave glenoids, convex reamers remove a similar amount of bone as flat reamers, but offer a larger surface area while maximizing the correction of the retroversion. In pathological uniconcave glenoids, convex reamers are preferred because of the conforming shape.
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S360
ASSESSING THE INITIAL STABILITY OF THE ACETABULAR IMPLANT: DEVELOPMENT OF AN INTRAOPERATIVE TOOL
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S360
ASSESSING THE INITIAL STABILITY OF THE ACETABULAR IMPLANT: DEVELOPMENT OF AN INTRAOPERATIVE TOOL