Jose María González-Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jose María González-Santos has a total of 289 co-authors. Here are the top co-authors by number of shared publications:
- María Elena Arnáiz-García
Cardiovascular Surgery Department, University Hospital of Salamanca, Salamanca, Spain
25 shared publications Javier López-Rodríguez
Cardiovascular Surgery Department, University Hospital of Salamanca, Salamanca, Spain
20 shared publicationsMaría José Dalmau-Sorlí
Cardiovascular Surgery Department, University Hospital of Salamanca, Salamanca, Spain
14 shared publicationsAdolfo Arévalo-Abascal
Cardiovascular Surgery Department, University Hospital of Salamanca, Salamanca, Spain
12 shared publicationsMaría Elena Arnáiz-García
Cardiovascular Surgery Department, University Hospital of Salamanca, Salamanca, Spain
12 shared publicationsJ L Vallejo
Servicio de Cirugía Cardiovascular, Hospital General Universitario Gregorio Marañón, Madrid
10 shared publications
Latest Publications
- Open Access
- 19 January 2021
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 10 (2) , e019949
Persistent Pulmonary Hypertension in Corrected Valvular Heart Disease: Hemodynamic Insights and Long‐Term Survival
Background: The determinants and consequences of pulmonary hypertension after successfully corrected valvular heart disease remain poorly understood. We aim to clarify the hemodynamic bases and risk factors for mortality in patients with this condition. Methods and Results: We analyzed long‐term follow‐up data of 222 patients with pulmonary hypertension and valvular heart disease successfully corrected at least 1 year before enrollment who had undergone comprehensive hemodynamic and imaging characterization as per the SIOVAC (Sildenafil for Improving Outcomes After Valvular Correction) clinical trial. Median (interquartile range) mean pulmonary pressure was 37 mm Hg (32–44 mm Hg) and pulmonary artery wedge pressure was 23 mm Hg (18–26 mm Hg). Most patients were classified either as having combined precapillary and postcapillary or isolated postcapillary pulmonary hypertension. After a median follow‐up of 4.5 years, 91 deaths accounted for 4.21 higher‐than‐expected mortality in the age‐matched population. Risk factors for mortality were male sex, older age, diabetes mellitus, World Health Organization functional class III and higher pulmonary vascular resistance—either measured by catheterization or approximated from ultrasound data. Higher pulmonary vascular resistance was related to diabetes mellitus and smaller residual aortic and mitral valve areas. In turn, the latter correlated with prosthetic nominal size. Six‐month changes in the composite clinical score and in the 6‐minute walk test distance were related to survival. Conclusions: Persistent valvular heart disease–pulmonary hypertension is an ominous disease that is almost universally associated with elevated pulmonary artery wedge pressure. Pulmonary vascular resistance is a major determinant of mortality in this condition and is related to diabetes mellitus and the residual effective area of the corrected valve. These findings have important implications for individualizing valve correction procedures. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT00862043.
- 19 January 2021
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 10 (2) , e019949
Open AccessPersistent Pulmonary Hypertension in Corrected Valvular Heart Disease: Hemodynamic Insights and Long‐Term Survival
Background: The determinants and consequences of pulmonary hypertension after successfully corrected valvular heart disease remain poorly understood. We aim to clarify the hemodynamic bases and risk factors for mortality in patients with this condition. Methods and Results: We analyzed long‐term follow‐up data of 222 patients with pulmonary hypertension and valvular heart disease successfully corrected at least 1 year before enrollment who had undergone comprehensive hemodynamic and imaging characterization as per the SIOVAC (Sildenafil for Improving Outcomes After Valvular Correction) clinical trial. Median (interquartile range) mean pulmonary pressure was 37 mm Hg (32–44 mm Hg) and pulmonary artery wedge pressure was 23 mm Hg (18–26 mm Hg). Most patients were classified either as having combined precapillary and postcapillary or isolated postcapillary pulmonary hypertension. After a median follow‐up of 4.5 years, 91 deaths accounted for 4.21 higher‐than‐expected mortality in the age‐matched population. Risk factors for mortality were male sex, older age, diabetes mellitus, World Health Organization functional class III and higher pulmonary vascular resistance—either measured by catheterization or approximated from ultrasound data. Higher pulmonary vascular resistance was related to diabetes mellitus and smaller residual aortic and mitral valve areas. In turn, the latter correlated with prosthetic nominal size. Six‐month changes in the composite clinical score and in the 6‐minute walk test distance were related to survival. Conclusions: Persistent valvular heart disease–pulmonary hypertension is an ominous disease that is almost universally associated with elevated pulmonary artery wedge pressure. Pulmonary vascular resistance is a major determinant of mortality in this condition and is related to diabetes mellitus and the residual effective area of the corrected valve. These findings have important implications for individualizing valve correction procedures. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT00862043.
- 8 August 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 58 (6) , 1311
Huge right-sided vegetations associated with pacemaker lead endocarditis
- 8 August 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 58 (6) , 1311
Huge right-sided vegetations associated with pacemaker lead endocarditis
- Open Access
- 12 June 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 58 (3) , 657
Giant pericardial cyst as the cause of syncope
- 12 June 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 58 (3) , 657
Open AccessGiant pericardial cyst as the cause of syncope
- 1 March 2020
- Published by Edizioni Minerva Medica in The Journal of Cardiovascular Surgery
- Vol. 61 (2) , 256-263
Spontaneous rupture of a mechanical valve in a mitral position (On-X) with migration-embolization to aortic bifurcation from the perspective of the vascular surgeon
We report on the case of spontaneous rupture of an On-X-pure pyrolytic carbon mechanical valve prosthesis implanted seven years earlier, in a mitral position, at our hospital. The patient was admitted with valvular dysfunction and acute pulmonary edema requiring emergency surgery (prosthesis replacement); the absence of a leaflet was confirmed intraoperatively. The patient presented severe respiratory failure, which prolonged the postoperative period. A CT scan showed that the migrated leaflet was located in the aortic bifurcation with no apparent arterial lesion. Four months later, once the patient had recovered, laparotomy and aortotomy were performed in order to retrieve the leaflet, which was found to have become included (neoendothelized) in the aortic wall without compromising the latter's integrity or obstructing the blood flow. A subsequent CT scan confirmed the persistence of the leaflet in its initial position. The literature review highlights two singular facts: 1) this is the second published case of the escape of a leaflet from an On-X prosthesis (the first patient died); 2) this is the first case in which a laparotomy was performed to retrieve the leaflet but finally a decision was made to leave it in situ. Seven months later, the patient remained asymptomatic.
- 1 March 2020
- Published by Edizioni Minerva Medica in The Journal of Cardiovascular Surgery
- Vol. 61 (2) , 256-263
Spontaneous rupture of a mechanical valve in a mitral position (On-X) with migration-embolization to aortic bifurcation from the perspective of the vascular surgeon
We report on the case of spontaneous rupture of an On-X-pure pyrolytic carbon mechanical valve prosthesis implanted seven years earlier, in a mitral position, at our hospital. The patient was admitted with valvular dysfunction and acute pulmonary edema requiring emergency surgery (prosthesis replacement); the absence of a leaflet was confirmed intraoperatively. The patient presented severe respiratory failure, which prolonged the postoperative period. A CT scan showed that the migrated leaflet was located in the aortic bifurcation with no apparent arterial lesion. Four months later, once the patient had recovered, laparotomy and aortotomy were performed in order to retrieve the leaflet, which was found to have become included (neoendothelized) in the aortic wall without compromising the latter's integrity or obstructing the blood flow. A subsequent CT scan confirmed the persistence of the leaflet in its initial position. The literature review highlights two singular facts: 1) this is the second published case of the escape of a leaflet from an On-X prosthesis (the first patient died); 2) this is the first case in which a laparotomy was performed to retrieve the leaflet but finally a decision was made to leave it in situ. Seven months later, the patient remained asymptomatic.
- Open Access
- 1 October 2018
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 55 (5) , 1018
Aspergillus niger prosthetic valve endocarditis
María Elena Arnáiz-García, José María González-Santos, Carlos Amorós-Rivera, Adolfo Arévalo-Abascal; Aspergillus niger prosthetic valve endocarditis, European
- 1 October 2018
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 55 (5) , 1018
Open AccessAspergillus niger prosthetic valve endocarditis
María Elena Arnáiz-García, José María González-Santos, Carlos Amorós-Rivera, Adolfo Arévalo-Abascal; Aspergillus niger prosthetic valve endocarditis, European
- Open Access
- 1 September 2017
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 24 (5) , 328-331
Registro Español de Reparación Valvular 2015
- 1 September 2017
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 24 (5) , 328-331
Open AccessRegistro Español de Reparación Valvular 2015
- 1 May 2017
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 9 (S6) , S488-S497
Wrapping of the ascending aorta revisited—is there any role left for conservative treatment of ascending aortic aneurysm?
Dilatation of the ascending aorta (AA) is a common finding in patients with aortic valve disease. The clinical practice guidelines recommend replacing the AA whenever the diameter exceeds 45 mm. However, no consensus has been reached regarding the approach when the aorta is only moderately dilated. Although the risk in aorta replacement is generally low, it may be higher when associated with other complex surgical procedures or it is carried out in elderly patients or patients with significant comorbidity. This would justify the use of alternative surgical techniques, which reduce surgical risk and guarantee a durable correction of the aortic pathology. Conservative treatment of aneurysms of the AA via wrapping with different synthetic materials has been implemented for many years. The most commonly used technical variant is wrapping the dilated aorta with a vascular prosthesis with a predetermined diameter. When this technique is adequately applied, it immediately reduces the diameter of the AA and, to a lesser degree, the diameter of the aortic root and arch, while at the same time it reinforces the weak aortic wall. These effects lead to a drop-in wall shear stress and in the risk of aortic dissection and rupture, and persist over time. Although the low elasticity of the external support causes significant changes in the histologic structure of the aortic wall, mainly atrophy and alterations typical of a foreign body-induced reaction, this does not seem to involve a higher risk of complications. In some selected patients, this technique may be used in cases other than post-stenotic aortopathy, and also in aortas with a larger diameter.
- 1 May 2017
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 9 (S6) , S488-S497
Wrapping of the ascending aorta revisited—is there any role left for conservative treatment of ascending aortic aneurysm?
Dilatation of the ascending aorta (AA) is a common finding in patients with aortic valve disease. The clinical practice guidelines recommend replacing the AA whenever the diameter exceeds 45 mm. However, no consensus has been reached regarding the approach when the aorta is only moderately dilated. Although the risk in aorta replacement is generally low, it may be higher when associated with other complex surgical procedures or it is carried out in elderly patients or patients with significant comorbidity. This would justify the use of alternative surgical techniques, which reduce surgical risk and guarantee a durable correction of the aortic pathology. Conservative treatment of aneurysms of the AA via wrapping with different synthetic materials has been implemented for many years. The most commonly used technical variant is wrapping the dilated aorta with a vascular prosthesis with a predetermined diameter. When this technique is adequately applied, it immediately reduces the diameter of the AA and, to a lesser degree, the diameter of the aortic root and arch, while at the same time it reinforces the weak aortic wall. These effects lead to a drop-in wall shear stress and in the risk of aortic dissection and rupture, and persist over time. Although the low elasticity of the external support causes significant changes in the histologic structure of the aortic wall, mainly atrophy and alterations typical of a foreign body-induced reaction, this does not seem to involve a higher risk of complications. In some selected patients, this technique may be used in cases other than post-stenotic aortopathy, and also in aortas with a larger diameter.
- Open Access
- 14 April 2017
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 24 (3) , 184-185
Estudio aleatorizado para comparar los resultados de la utilización de una o las 2 arterias mamarias en la cirugía coronaria
- 14 April 2017
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 24 (3) , 184-185
Open AccessEstudio aleatorizado para comparar los resultados de la utilización de una o las 2 arterias mamarias en la cirugía coronaria
- 1 January 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 103 (1) , e91
A Mitral Heart Valve Prosthesis Hidden Under Perivalvular Pannus
- 1 January 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 103 (1) , e91
A Mitral Heart Valve Prosthesis Hidden Under Perivalvular Pannus
- 21 December 2016
- Published by Polskie Towarzystwo Kardiologiczne in Polish Heart Journal
- Vol. 74 (12) , 1505
Stenosis, more than critical, of the left main coronary artery in an asymptomatic patient
- 21 December 2016
- Published by Polskie Towarzystwo Kardiologiczne in Polish Heart Journal
- Vol. 74 (12) , 1505
Stenosis, more than critical, of the left main coronary artery in an asymptomatic patient