Mojdeh Monjezi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mojdeh Monjezi has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Elaheh Malakan Rad
Department of Pediatric Cardiology, Children’s Medical Center (Pediatric Center of Excellence), Tehran University of Medical Sciences, Tehran, Iran
2 shared publications Hamidreza Jamaati
Chronic Respiratory Diseases Research Center (CRDRC), National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran
2 shared publications- Hamidreza Jamaati
Chronic Respiratory Diseases Research Center, National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran
2 shared publications M.S. Saidi
2 shared publications- Ahmad Reza Pishevar
Department of Mechanical Engineering Isfahan University of Technology 84156-8311 Isfahan Iran
1 shared publication B. Firoozabadi
1 shared publication
Latest Publications
- Open Access
- 1 February 2024
- Vol. 23 (2) , 139-145
Airflow-Related Shear Stress: The Main Cause of VILI or not?
The physical basis of ventilator-induced lung injury has been explored extensively in the last decades. The three mechanisms named volutrauma (overdistension of alveoli), barotrauma (high airway pressure), and atelectrauma (cyclic opening and closing of alveoli) have been known as the main mechanisms of lung injury. Lowering tidal volume and applying positive end-expiratory pressure have been suggested to minimize these mechanisms. Besides, some researchers believe that elevated airflow-related shear stress on the epithelial cell layer could cause an inflammatory response. In this study, a simplified 0-D model for air flow in human lungs has computed the airflow-related shear stress. The airway resistance, compliance, and inertance have been calculated using Womersley analysis and included in this model. Considering a constant flow, volume-controlled mechanical ventilation, the effect of ventilation parameters including tidal volume, respiratory rate, and inspiratory/expiratory ratio on the magnitude of shear stress has been investigated. The results show that high tidal volume, high respiratory rate, and low inspiratory/expiratory ratio, increase the magnitude of wall shear stress but still in the safety range. This result suggests that airflow-related shear stress is not the primary cause of mechanical damage. So far, it has been assumed that wall shear stress plays a critical role in ventilator-induced lung injury. This paper enhances our understanding of wall shear stress magnitude, indicating that the shear stress from airflow in mechanical ventilation is not high enough to inflict mechanical damage on pulmonary epithelial cells.
- 1 February 2024
- Vol. 23 (2) , 139-145
Open AccessAirflow-Related Shear Stress: The Main Cause of VILI or not?
The physical basis of ventilator-induced lung injury has been explored extensively in the last decades. The three mechanisms named volutrauma (overdistension of alveoli), barotrauma (high airway pressure), and atelectrauma (cyclic opening and closing of alveoli) have been known as the main mechanisms of lung injury. Lowering tidal volume and applying positive end-expiratory pressure have been suggested to minimize these mechanisms. Besides, some researchers believe that elevated airflow-related shear stress on the epithelial cell layer could cause an inflammatory response. In this study, a simplified 0-D model for air flow in human lungs has computed the airflow-related shear stress. The airway resistance, compliance, and inertance have been calculated using Womersley analysis and included in this model. Considering a constant flow, volume-controlled mechanical ventilation, the effect of ventilation parameters including tidal volume, respiratory rate, and inspiratory/expiratory ratio on the magnitude of shear stress has been investigated. The results show that high tidal volume, high respiratory rate, and low inspiratory/expiratory ratio, increase the magnitude of wall shear stress but still in the safety range. This result suggests that airflow-related shear stress is not the primary cause of mechanical damage. So far, it has been assumed that wall shear stress plays a critical role in ventilator-induced lung injury. This paper enhances our understanding of wall shear stress magnitude, indicating that the shear stress from airflow in mechanical ventilation is not high enough to inflict mechanical damage on pulmonary epithelial cells.
- Open Access
- 11 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (20) , 9418
Anti-Cancer Drug Screening with Microfluidic Technology
The up-and-coming microfluidic technology is the most promising platform for designing anti-cancer drugs and new point-of-care diagnostics. Compared to conventional drug screening methods based on Petri dishes and animal studies, drug delivery in microfluidic systems has many advantages. For instance, these platforms offer high-throughput drug screening, require a small number of samples, provide an in vivo-like microenvironment for cells, and eliminate ethical issues associated with animal studies. Multiple cell cultures in microfluidic chips could better mimic the 3D tumor environment using low reagents consumption. The clinical experiments have shown that combinatorial drug treatments have a better therapeutic effect than monodrug therapy. Many attempts have been made in this field in the last decade. This review highlights the applications of microfluidic chips in anti-cancer drug screening and systematically categorizes these systems as a function of sample size and combination of drug screening. Finally, it provides a perspective on the future of the clinical applications of microfluidic systems for anti-cancer drug development.
- 11 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (20) , 9418
Open AccessAnti-Cancer Drug Screening with Microfluidic Technology
The up-and-coming microfluidic technology is the most promising platform for designing anti-cancer drugs and new point-of-care diagnostics. Compared to conventional drug screening methods based on Petri dishes and animal studies, drug delivery in microfluidic systems has many advantages. For instance, these platforms offer high-throughput drug screening, require a small number of samples, provide an in vivo-like microenvironment for cells, and eliminate ethical issues associated with animal studies. Multiple cell cultures in microfluidic chips could better mimic the 3D tumor environment using low reagents consumption. The clinical experiments have shown that combinatorial drug treatments have a better therapeutic effect than monodrug therapy. Many attempts have been made in this field in the last decade. This review highlights the applications of microfluidic chips in anti-cancer drug screening and systematically categorizes these systems as a function of sample size and combination of drug screening. Finally, it provides a perspective on the future of the clinical applications of microfluidic systems for anti-cancer drug development.
- Open Access
- 15 September 2020
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 19 (1) , 1-14
The effects of pressure- versus volume-controlled ventilation on ventilator work of breathing
Background: Measurement of work of breathing (WOB) during mechanical ventilation is essential to assess the status and progress of intensive care patients. Increasing ventilator WOB is known as a risk factor for ventilator-induced lung injury (VILI). In addition, the minimization of WOB is crucial to facilitate the weaning process. Several studies have assessed the effects of varying inspiratory flow waveforms on the patient’s WOB during assisted ventilation, but there are few studies on the different effect of inspiratory flow waveforms on ventilator WOB during controlled ventilation. Methods: In this paper, we analyze the ventilator WOB, termed mechanical work (MW) for three common inspiratory flow waveforms both in normal subjects and COPD patients. We use Rohrer’s equation for the resistance of the endotracheal tube (ETT) and lung airways. The resistance of pulmonary and chest wall tissue are also considered. Then, the resistive MW required to overcome each component of the respiratory resistance is computed for square and sinusoidal waveforms in volume-controlled ventilation (VCV), and decelerating waveform of flow in pressure-controlled ventilation (PCV). Results: The results indicate that under the constant I:E ratio, a square flow profile best minimizes the MW both in normal subjects and COPD patients. Furthermore, the large I:E ratio may be used to lower MW. The comparison of results shows that ETT and lung airways have the main contribution to resistive MW in normals and COPDs, respectively. Conclusion: These findings support that for lowering the MW especially in patients with obstructive lung diseases, flow with square waveforms in VCV, are more favorable than decelerating waveform of flow in PCV. Our analysis suggests the square profile is the best choice from the viewpoint of less MW.
- 15 September 2020
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 19 (1) , 1-14
Open AccessThe effects of pressure- versus volume-controlled ventilation on ventilator work of breathing
Background: Measurement of work of breathing (WOB) during mechanical ventilation is essential to assess the status and progress of intensive care patients. Increasing ventilator WOB is known as a risk factor for ventilator-induced lung injury (VILI). In addition, the minimization of WOB is crucial to facilitate the weaning process. Several studies have assessed the effects of varying inspiratory flow waveforms on the patient’s WOB during assisted ventilation, but there are few studies on the different effect of inspiratory flow waveforms on ventilator WOB during controlled ventilation. Methods: In this paper, we analyze the ventilator WOB, termed mechanical work (MW) for three common inspiratory flow waveforms both in normal subjects and COPD patients. We use Rohrer’s equation for the resistance of the endotracheal tube (ETT) and lung airways. The resistance of pulmonary and chest wall tissue are also considered. Then, the resistive MW required to overcome each component of the respiratory resistance is computed for square and sinusoidal waveforms in volume-controlled ventilation (VCV), and decelerating waveform of flow in pressure-controlled ventilation (PCV). Results: The results indicate that under the constant I:E ratio, a square flow profile best minimizes the MW both in normal subjects and COPD patients. Furthermore, the large I:E ratio may be used to lower MW. The comparison of results shows that ETT and lung airways have the main contribution to resistive MW in normals and COPDs, respectively. Conclusion: These findings support that for lowering the MW especially in patients with obstructive lung diseases, flow with square waveforms in VCV, are more favorable than decelerating waveform of flow in PCV. Our analysis suggests the square profile is the best choice from the viewpoint of less MW.
- Open Access
- 11 May 2020
- Published by Springer Nature in Research Square
Effect of inspiratory flow waveforms on the mechanical work of ventilation; a fluid dynamic analysis
In most intensive care patients, the mechanical work (MW) is increased due to airway obstruction and/or tracheal intubation. Increasing MW is known as a risk factor for ventilator induced lung injury (VILI). Moeover, minimizing of MW is crucial to facilitate weaning process. In this paper MW is compared between three different inspiratory flow waveforms. The fluid dynamic analysis is used to compute the resistive pressure drop and the resistive work. We have compared square, sinusoidal and decelerating flow waveforms under the same tidal volume. The results show that under the constant tidal volume and I:E ratio, for tidal volumes below 1 lit, an square flow profile is beneficial for minimizing MW while a sinusoidal flow profile is prefered for tidal volumes of 1 lit or higher. It is shown that for make a decision about most beneficial flow profile in terms of less MW, both tidal volume and I:E ratio is important. By the way the results suggest to use decelerating flow waveforms with higher 1:E ratio. The qualitative conclusion is that in order to lower the MW especially in patients with obstructive lung diseases, sinusoidal, square and decelerating flow became preferable respectively with increasing I:E ratio. Our study suggest the square and sinusoidal profile for tidal volumes below and equal or over 1 lit, respectively in pointwiew of less MW. This paper also encouraged the engineers to add an option to select sinusoidal flow waveform in VCV mode to lower MW when tidal volume is l lit or higher.
- 11 May 2020
- Published by Springer Nature in Research Square
Open AccessEffect of inspiratory flow waveforms on the mechanical work of ventilation; a fluid dynamic analysis
In most intensive care patients, the mechanical work (MW) is increased due to airway obstruction and/or tracheal intubation. Increasing MW is known as a risk factor for ventilator induced lung injury (VILI). Moeover, minimizing of MW is crucial to facilitate weaning process. In this paper MW is compared between three different inspiratory flow waveforms. The fluid dynamic analysis is used to compute the resistive pressure drop and the resistive work. We have compared square, sinusoidal and decelerating flow waveforms under the same tidal volume. The results show that under the constant tidal volume and I:E ratio, for tidal volumes below 1 lit, an square flow profile is beneficial for minimizing MW while a sinusoidal flow profile is prefered for tidal volumes of 1 lit or higher. It is shown that for make a decision about most beneficial flow profile in terms of less MW, both tidal volume and I:E ratio is important. By the way the results suggest to use decelerating flow waveforms with higher 1:E ratio. The qualitative conclusion is that in order to lower the MW especially in patients with obstructive lung diseases, sinusoidal, square and decelerating flow became preferable respectively with increasing I:E ratio. Our study suggest the square and sinusoidal profile for tidal volumes below and equal or over 1 lit, respectively in pointwiew of less MW. This paper also encouraged the engineers to add an option to select sinusoidal flow waveform in VCV mode to lower MW when tidal volume is l lit or higher.
- 18 September 2019
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 47 (12) , 2353-2354
Airflow Simulation in Pulmonary Conducting Airways
- 18 September 2019
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 47 (12) , 2353-2354
Airflow Simulation in Pulmonary Conducting Airways
- 23 April 2016
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (2) , 213-224
Pulsatile blood flow in total cavopulmonary connection: a comparison between Y-shaped and T-shaped geometry
Single-ventricle anomaly is a hereditary heart disease that is characterized by anatomical malformations. The main consequence of this malformation is desaturated blood flow, which without proper treatment increases the risk of death. The classical treatment is based on a three-stage palliative procedure which should begin from the first few days of patient’s life. The final stage is known as Fontan procedure, in which inferior vena cava is directly connected to pulmonary arteries without going through the ventricle. This connection is called total cavopulmonary connection (TCPC). After surgery, the single ventricle supplies adequate and saturated systemic blood flow to the body; however, TCPC contains low pressure and low flow pulsatility. To overcome this problem, a new method is proposed wherein pulsatile blood will be directed to the TCPC through the stenosed main pulmonary artery. In this study, through the use of Computational Fluid Dynamics, T-shaped (MRI-based) and Y-shaped (computer-generated) geometries are compared in order to determine the influence of this modification on pulsation of blood flow as well as energy loss in pulmonary arteries. The results indicate that energy loss in Y-shaped geometry is far less than T-shaped geometry, while the difference in flow pulsatility is insignificant.
- 23 April 2016
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (2) , 213-224
Pulsatile blood flow in total cavopulmonary connection: a comparison between Y-shaped and T-shaped geometry
Single-ventricle anomaly is a hereditary heart disease that is characterized by anatomical malformations. The main consequence of this malformation is desaturated blood flow, which without proper treatment increases the risk of death. The classical treatment is based on a three-stage palliative procedure which should begin from the first few days of patient’s life. The final stage is known as Fontan procedure, in which inferior vena cava is directly connected to pulmonary arteries without going through the ventricle. This connection is called total cavopulmonary connection (TCPC). After surgery, the single ventricle supplies adequate and saturated systemic blood flow to the body; however, TCPC contains low pressure and low flow pulsatility. To overcome this problem, a new method is proposed wherein pulsatile blood will be directed to the TCPC through the stenosed main pulmonary artery. In this study, through the use of Computational Fluid Dynamics, T-shaped (MRI-based) and Y-shaped (computer-generated) geometries are compared in order to determine the influence of this modification on pulsation of blood flow as well as energy loss in pulmonary arteries. The results indicate that energy loss in Y-shaped geometry is far less than T-shaped geometry, while the difference in flow pulsatility is insignificant.
- 1 June 2014
- Published by Elsevier in Atmospheric Environment
- Vol. 89, 199-206
Comparison between Lagrangian and Eulerian approaches in predicting motion of micron-sized particles in laminar flows
- 1 June 2014
- Published by Elsevier in Atmospheric Environment
- Vol. 89, 199-206
Comparison between Lagrangian and Eulerian approaches in predicting motion of micron-sized particles in laminar flows
- 1 December 2012
- Published by Elsevier in Scientia Iranica
- Vol. 19 (6) , 1479-1486
Prediction of particle deposition in the respiratory track using 3D–1D modeling
- 1 December 2012
- Published by Elsevier in Scientia Iranica
- Vol. 19 (6) , 1479-1486
Prediction of particle deposition in the respiratory track using 3D–1D modeling