Massimo Morale
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Massimo Morale has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Messineo
Dipartimento di Ingegneria e Architettura, Università degli Studi di Enna “Kore”, Cittadella Universitaria, 94100 Enna, Italy
6 shared publications - Domenico Panno
Sustainability and Ecological Transition Center, University of Palermo, Piazza Marina, 61, 90133 Palermo, Italy
6 shared publications - Gianluca Scaccianoce
Department of Engineering, University of Palermo, Viale delle Scienze Bld. 9, 90128 Palermo, Italy
3 shared publications Vincenzo La Rocca
Università degli Studi di Palermo
3 shared publicationsAntonella Dispenza
Dipartimento Energia, Ingegneria dell’informazione e Modelli Matematici, Università degli Studi di Palermo, Parco d’Orleans, Viale delle Scienze, Ed. 9, 90128 Palermo, Italy
2 shared publications- Antonino La Rocca
Department of Mechanical Materials and Manufacturing Engineering, University of Nottingham, Nottingham NG7 2RD, UK
2 shared publications
Latest Publications
- 1 May 2015
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 35, 35-45
Safety study of an LNG regasification plant using an FMECA and HAZOP integrated methodology
- 1 May 2015
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 35, 35-45
Safety study of an LNG regasification plant using an FMECA and HAZOP integrated methodology
- 1 November 2014
- Published by Elsevier in Energy Conversion and Management
- Vol. 87, 495-503
Optimization of a thermoelectric system for power generation realized by “hidden” components
- 1 November 2014
- Published by Elsevier in Energy Conversion and Management
- Vol. 87, 495-503
Optimization of a thermoelectric system for power generation realized by “hidden” components
- 1 September 2013
- Published by Elsevier in Sustainable Energy Technologies and Assessments
- Vol. 3, 17-26
Absorption equipment for energy savings: A case study in Sicily
- 1 September 2013
- Published by Elsevier in Sustainable Energy Technologies and Assessments
- Vol. 3, 17-26
Absorption equipment for energy savings: A case study in Sicily
- 22 April 2013
- Published by WITPRESS LTD.
Modelling heat transfer-controlled cooling and freezing times: a comparison between computational values and experimental results
Modelling of heat transfer-controlled cooling and freezing time predictions are very important for a good preservation of foodstuffs. In that...
- 22 April 2013
- Published by WITPRESS LTD.
Modelling heat transfer-controlled cooling and freezing times: a comparison between computational values and experimental results
Modelling of heat transfer-controlled cooling and freezing time predictions are very important for a good preservation of foodstuffs. In that...
- 1 March 2013
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 19 (3) , 1044-1047
Numerical Solution of Foodstuff Freezing Problems Using Radial Basis Functions
- 1 March 2013
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 19 (3) , 1044-1047
Numerical Solution of Foodstuff Freezing Problems Using Radial Basis Functions
- 13 February 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 291-294, 1696-1700
A Testing Facility for Refrigerating Plants Equipment Working with New Fluids
A test rig was built in the department of energy, in laboratory of refrigerating engineering for test runs with a lot of fluid and equipment of various kind for commercial refrigeration. The facility has been continuously improved during the past years and allows to perform experiments aiming to assess the performance characteristics both of conventional and new equipment for commercial refrigeration. In the test rig can be tested a lot of cooling loop filled with a secondary fluid for simulation of their behavior in industrial and commercial plants (e.g.: during exploitation in supermarket and hypermarket for refrigeration of foodstuffs in cold store, display cases and cabinets, etc.). The paper reports main results of the experiments performed with the new fluid R422A versus the original refrigerating fluid R22.
- 13 February 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 291-294, 1696-1700
A Testing Facility for Refrigerating Plants Equipment Working with New Fluids
A test rig was built in the department of energy, in laboratory of refrigerating engineering for test runs with a lot of fluid and equipment of various kind for commercial refrigeration. The facility has been continuously improved during the past years and allows to perform experiments aiming to assess the performance characteristics both of conventional and new equipment for commercial refrigeration. In the test rig can be tested a lot of cooling loop filled with a secondary fluid for simulation of their behavior in industrial and commercial plants (e.g.: during exploitation in supermarket and hypermarket for refrigeration of foodstuffs in cold store, display cases and cabinets, etc.). The paper reports main results of the experiments performed with the new fluid R422A versus the original refrigerating fluid R22.
- 13 February 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 291-294, 1631-1635
Analysis of Air Cycle and Efficiency Evaluation for a Blast Freezing Tunnel Plant
Air refrigerating systems offer a suitable alternative to vapour compression systems. Air can be used as working fluid in gas compression cycles for refrigeration, air conditioning and heat pump systems. This paper gives some results of theoretical investigation into improved air cycles for refrigeration systems and a comparison is made with their performances. The case-study relates to a dual purpose refrigerating plant. A blast freezing tunnel gives the coldest air stream and, in cascade, the air coming out from the tunnel is used in a channel network for feeding a lot of chilling cells. The case-study analysed indicates that there is a real possibility to build plants which will be equipped with air inverse cycles.
- 13 February 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 291-294, 1631-1635
Analysis of Air Cycle and Efficiency Evaluation for a Blast Freezing Tunnel Plant
Air refrigerating systems offer a suitable alternative to vapour compression systems. Air can be used as working fluid in gas compression cycles for refrigeration, air conditioning and heat pump systems. This paper gives some results of theoretical investigation into improved air cycles for refrigeration systems and a comparison is made with their performances. The case-study relates to a dual purpose refrigerating plant. A blast freezing tunnel gives the coldest air stream and, in cascade, the air coming out from the tunnel is used in a channel network for feeding a lot of chilling cells. The case-study analysed indicates that there is a real possibility to build plants which will be equipped with air inverse cycles.
- 1 December 2012
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 260-261, 611-617
Advanced Refrigerating Plants Based on Transcritical Cycles Working with Carbon Dioxide for Commercial Refrigeration
Supermarkets and hypermarkets require a huge amount of energy to maintain chilled and frozen food in product display cases and cold storage rooms and thermal comfort in the whole building. Systems exploited require very large refrigerant charges for operation and suffer significant leakages. The challenge for advanced systems, based on equipment which reduce TEWI, suggests the proposal of carbon dioxide: a natural working fluid. This paper deals with a feasibility study of a refrigerating system for a big hypermarket in Sicily based on a three-stage transcritical cycle working with carbon dioxide which is compared with an alternative system composed of two cycles operating as a binary refrigerating plant: a top cycle working with propane and a bottom cycle working with carbon dioxide. The cold is produced at two temperature: - 15°C and -35°C. In both alternative systems, cold at -15°C will be delivered to display cases, cold stores etc. by means of a secondary loop into which circulates a refrigerant fluid (e.g. an ethylene-glycol solution), while cold at -35°C will be delivered by another loop into which circulates directly liquid carbon dioxide. Main results obtained demonstrate the effective feasibility of plants which seem suitable for commercial refrigeration, bearing in mind that is of capital relevance the best operating efficiency of the secondary loop system. This depends mainly on thorough design and building of the secondary loops, especially for those which op erate at lower temperature.
- 1 December 2012
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 260-261, 611-617
Advanced Refrigerating Plants Based on Transcritical Cycles Working with Carbon Dioxide for Commercial Refrigeration
Supermarkets and hypermarkets require a huge amount of energy to maintain chilled and frozen food in product display cases and cold storage rooms and thermal comfort in the whole building. Systems exploited require very large refrigerant charges for operation and suffer significant leakages. The challenge for advanced systems, based on equipment which reduce TEWI, suggests the proposal of carbon dioxide: a natural working fluid. This paper deals with a feasibility study of a refrigerating system for a big hypermarket in Sicily based on a three-stage transcritical cycle working with carbon dioxide which is compared with an alternative system composed of two cycles operating as a binary refrigerating plant: a top cycle working with propane and a bottom cycle working with carbon dioxide. The cold is produced at two temperature: - 15°C and -35°C. In both alternative systems, cold at -15°C will be delivered to display cases, cold stores etc. by means of a secondary loop into which circulates a refrigerant fluid (e.g. an ethylene-glycol solution), while cold at -35°C will be delivered by another loop into which circulates directly liquid carbon dioxide. Main results obtained demonstrate the effective feasibility of plants which seem suitable for commercial refrigeration, bearing in mind that is of capital relevance the best operating efficiency of the secondary loop system. This depends mainly on thorough design and building of the secondary loops, especially for those which op erate at lower temperature.
- 1 November 2010
- Published by Elsevier in Applied Thermal Engineering
- Vol. 30 (16) , 2386-2395
Comparing different control strategies for indoor thermal comfort aimed at the evaluation of the energy cost of quality of building
- 1 November 2010
- Published by Elsevier in Applied Thermal Engineering
- Vol. 30 (16) , 2386-2395
Comparing different control strategies for indoor thermal comfort aimed at the evaluation of the energy cost of quality of building