FBFrank Hendrik Bosch

Frank Hendrik Bosch

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Frank Hendrik Bosch has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Continuous Monitoring by a Wearable Sensor Did Not Enhance Discharge Decision-Making in an Acute Admission Ward: Results of a Randomized Controlled Trial

    by Niels Kant, Sjoerd H. Garssen, Carlijn A. Vernooij, Gert-Jan Mauritz, Mark V. Koning, Frank H. Bosch, Carine J.M. Doggen

    Adding continuous monitoring to usual care at an acute admission ward did not have an effect on the proportion of patients safely discharged. Implementation challenges of continuous monitoring may have contributed to the lack of effect observed.

  • Open Access

    Predicting whether patients in an acute medical unit are physiologically fit-for-discharge using machine learning: A proof-of-concept

    by S.H. Garssen, C.A. Vernooij, N. Kant, M.V. Koning, F.H. Bosch, C.J.M. Doggen, B.P. Veldkamp, W.F.J. Verhaegh, S.F. Oude Wesselink


  • Open Access

    Enhancing discharge decision-making through continuous monitoring in an acute admission ward: a randomized controlled trial

    by Niels Kant, Sjoerd H. Garssen, Carlijn A. Vernooij, Gert-Jan Mauritz, Mark V. Koning, Frank H. Bosch, Carine J. M. Doggen

    In Acute Admission Wards, vital signs are commonly measured only intermittently. This may result in failure to detect early signs of patient deterioration and impede timely identification of patient stability, ultimately leading to prolonged stays and avoidable hospital admissions. Therefore, continuous vital sign monitoring may improve hospital efficacy. The objective of this randomized controlled trial was to evaluate the effect of continuous monitoring on the proportion of patients safely discharged home directly from an Acute Admission Ward. Patients were randomized to either the control group, which received usual care, or the sensor group, which additionally received continuous monitoring using a wearable sensor. The continuous measurements could be considered in discharge decision-making by physicians during the daily bedside rounds. Safe discharge was defined as no unplanned readmissions, emergency department revisits or deaths, within 30 days after discharge. Additionally, length of stay, the number of Intensive Care Unit admissions and Rapid Response Team calls were assessed. In total, 400 patients were randomized, of which 394 completed follow-up, with 196 assigned to the sensor group and 198 to the control group. The proportion of patients safely discharged home was 33.2% in the sensor group and 30.8% in the control group (p = 0.62). No significant differences were observed in secondary outcomes. The trial was terminated prematurely due to futility. In conclusion, continuous monitoring did not have an effect on the proportion of patients safely discharged from an Acute Admission Ward. Implementation challenges of continuous monitoring may have contributed to the lack of effect observed. Trial registration: https://clinicaltrials.gov/ct2/show/NCT05181111. Registered: January 6, 2022.


  • Open Access

    POCUS in dyspnea, nontraumatic hypotension, and shock; a systematic review of existing evidence

    by Bram Kok, David Wolthuis, Frank Bosch, Hans van der Hoeven, Michiel Blans


  • Open Access

    Universal Do-Not-Resuscitate Orders, Social Worth, and Life-Years

    by Eric C.T. Geijteman, Frank H. Bosch, Yvo M. Smulders


  • Point-of-care ultrasound in internal medicine: A position paper by the ultrasound working group of the European federation of internal medicine

    by J. Torres-Macho, T. Aro, I. Bruckner, C. Cogliati, O.H. Gilja, A. Gurghean, E. Karlafti, M. Krsek, Z. Monhart, A. Müller-Marbach, et al.


  • Open Access

    The use of an external ultrasound fixator (Probefix) on intensive care patients: a feasibility study

    by M. J. Blans, F. H. Bosch, J. G. van der Hoeven

    Background: In critical care medicine, the use of transthoracic echo (TTE) is expanding. TTE can be used to measure dynamic parameters such as cardiac output (CO). An important asset of TTE is that it is a non-invasive technique. The Probefix is an external ultrasound holder strapped to the patient which makes it possible to measure CO using TTE in a fixed position possibly making the CO measurements more accurate compared to separate TTE CO measurements. The feasibility of the use of the Probefix to measure CO before and after a passive leg raising test (PLR) was studied. Intensive care patients were included after detection of hypovolemia using Flotrac. Endpoints were the possibility to use Probefix. Also CO measurements with and without the use of Probefix, before and after a PLR were compared to the CO measurements using Flotrac. Side effects in terms of skin alterations after the use of Probefix and patient’s comments on (dis)comfort were evaluated. Results: Ten patients were included; in eight patients, sufficient recordings with the use of Probefix could be obtained. Using Bland–Altman plots, no difference was found in accuracy of measurements of CO with or without the use of Probefix before and after a PLR compared to Flotrac generated CO. There were only mild and temporary skin effects of the use of Probefix. Conclusions: In this small feasibility study, the Probefix could be used in eight out of ten intensive care patients. The use of Probefix did not result in more or less accurate CO measurements compared to manually recorded TTE CO measurements. We suggest that larger studies on the use of Probefix in intensive care patients are needed.


  • Open Access

    RELAx – REstricted versus Liberal positive end-expiratory pressure in patients without ARDS: protocol for a randomized controlled trial

    by Anna Geke Algera, Luigi Pisani, Dennis C. J. Bergmans, Sylvia Den Boer, Corianne A. J. De Borgie, Frank H. Bosch, Karina Bruin, Thomas G. Cherpanath, Rogier M. Determann, Arjen M. Dondorp, et al.

    Evidence for benefit of high positive end-expiratory pressure (PEEP) is largely lacking for invasively ventilated, critically ill patients with uninjured lungs. We hypothesize that ventilation with low PEEP is noninferior to ventilation with high PEEP with regard to the number of ventilator-free days and being alive at day 28 in this population. The “REstricted versus Liberal positive end-expiratory pressure in patients without ARDS” trial (RELAx) is a national, multicenter, randomized controlled, noninferiority trial in adult intensive care unit (ICU) patients with uninjured lungs who are expected not to be extubated within 24 h. RELAx will run in 13 ICUs in the Netherlands to enroll 980 patients under invasive ventilation. In all patients, low tidal volumes are used. Patients assigned to ventilation with low PEEP will receive the lowest possible PEEP between 0 and 5 cm H2O, while patients assigned to ventilation with high PEEP will receive PEEP of 8 cm H2O. The primary endpoint is the number of ventilator-free days and being alive at day 28, a composite endpoint for liberation from the ventilator and mortality until day 28, with a noninferiority margin for a difference between groups of 0.5 days. Secondary endpoints are length of stay (LOS), mortality, and occurrence of pulmonary complications, including severe hypoxemia, major atelectasis, need for rescue therapies, pneumonia, pneumothorax, and development of acute respiratory distress syndrome (ARDS). Hemodynamic support and sedation needs will be collected and compared. RELAx will be the first sufficiently sized randomized controlled trial in invasively ventilated, critically ill patients with uninjured lungs using a clinically relevant and objective endpoint to determine whether invasive, low-tidal-volume ventilation with low PEEP is noninferior to ventilation with high PEEP. ClinicalTrials.gov , ID: NCT03167580 . Registered on 23 May 2017.


  • Open Access

    Early EEG for outcome prediction of postanoxic coma: prospective cohort study with cost-minimization analysis

    by Lotte Sondag, Barry J. Ruijter, Marleen C. Tjepkema-Cloostermans, Albertus Beishuizen, Frank H. Bosch, Janine A. van Til, Michel J. A. M. van Putten, Jeannette Hofmeijer

    We recently showed that electroencephalography (EEG) patterns within the first 24 hours robustly contribute to multimodal prediction of poor or good neurological outcome of comatose patients after cardiac arrest. Here, we confirm these results and present a cost-minimization analysis. Early prognosis contributes to communication between doctors and family, and may prevent inappropriate treatment. A prospective cohort study including 430 subsequent comatose patients after cardiac arrest was conducted at intensive care units of two teaching hospitals. Continuous EEG was started within 12 hours after cardiac arrest and continued up to 3 days. EEG patterns were visually classified as unfavorable (isoelectric, low-voltage, or burst suppression with identical bursts) or favorable (continuous patterns) at 12 and 24 hours after cardiac arrest. Outcome at 6 months was classified as good (cerebral performance category (CPC) 1 or 2) or poor (CPC 3, 4, or 5). Predictive values of EEG measures and cost-consequences from a hospital perspective were investigated, assuming EEG-based decision- making about withdrawal of life-sustaining treatment in the case of a poor predicted outcome. Poor outcome occurred in 197 patients (51% of those included in the analyses). Unfavorable EEG patterns at 24 hours predicted a poor outcome with specificity of 100% (95% CI 98–100%) and sensitivity of 29% (95% CI 22–36%). Favorable patterns at 12 hours predicted good outcome with specificity of 88% (95% CI 81–93%) and sensitivity of 51% (95% CI 42–60%). Treatment withdrawal based on an unfavorable EEG pattern at 24 hours resulted in a reduced mean ICU length of stay without increased mortality in the long term. This gave small cost reductions, depending on the timing of withdrawal. Early EEG contributes to reliable prediction of good or poor outcome of postanoxic coma and may lead to reduced length of ICU stay. In turn, this may bring small cost reductions.