Tiberiu Polocoser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tiberiu Polocoser has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Bohumil Kasal
Technische Universität Braunschweig
7 shared publications Frank Stöckel
Surfactor
3 shared publicationsAndreas Heiduschke
HESS TIMBER GmbH & Co. KG
2 shared publicationsBohumil Kasal
Technische Universität Braunschweig and Fraunhofer Wilhelm Klauditz Institute
2 shared publications- Norbert Rüther
Fraunhofer Institut für Holzforschung, Wilhelm-Klauditz-Institut WKI Riedenkamp 3 38112 Braunschweig
2 shared publications - Stanislav Pospíšil
ÚTAM AV ČR, v.v.i.
2 shared publications
Latest Publications
- 19 May 2018
- Published by Springer Nature in Materials and Structures
- Vol. 51 (3) , 71
Dynamic material properties of wood subjected to low-velocity impact
- 19 May 2018
- Published by Springer Nature in Materials and Structures
- Vol. 51 (3) , 71
Dynamic material properties of wood subjected to low-velocity impact
- 14 January 2018
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 21 (11) , 1652-1663
Report on the seismic performance of three-dimensional moment-resisting timber frames with frictional damping in beam-to-column connections
The seismic performance of three-dimensional moment-resisting timber frames with frictional damping devices was investigated experimentally. This article describes a novel three-dimensional beam-to-column connection which was designed to behave rigidly up to moderate seismic intensities and to start the frictional dissipating behavior at higher intensities. The three-dimensional beam-to-column connection component was initially tested under cyclic loading, and then the connection was mounted in a three-level prototype frame and tested on a shake table. From the cyclic loading tests, the energy dissipation of the proposed beam-to-column connection was higher than the equivalent rigid connection. The frame demonstrated self-aligning capabilities without permanent drift at seismic intensities up to 1.4 g and maintained strength up to high seismic intensities of 2 g. Because wood frames allow for large elastic deflections and can exhibit excellent self-aligning capabilities (i.e., connections tolerate large rotations within safe stress levels), the proposed frictional beam-to-column connection is a promising alternative for moment-resisting timber frames that can be used to prevent structural members from reaching critical stresses.
- 14 January 2018
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 21 (11) , 1652-1663
Report on the seismic performance of three-dimensional moment-resisting timber frames with frictional damping in beam-to-column connections
The seismic performance of three-dimensional moment-resisting timber frames with frictional damping devices was investigated experimentally. This article describes a novel three-dimensional beam-to-column connection which was designed to behave rigidly up to moderate seismic intensities and to start the frictional dissipating behavior at higher intensities. The three-dimensional beam-to-column connection component was initially tested under cyclic loading, and then the connection was mounted in a three-level prototype frame and tested on a shake table. From the cyclic loading tests, the energy dissipation of the proposed beam-to-column connection was higher than the equivalent rigid connection. The frame demonstrated self-aligning capabilities without permanent drift at seismic intensities up to 1.4 g and maintained strength up to high seismic intensities of 2 g. Because wood frames allow for large elastic deflections and can exhibit excellent self-aligning capabilities (i.e., connections tolerate large rotations within safe stress levels), the proposed frictional beam-to-column connection is a promising alternative for moment-resisting timber frames that can be used to prevent structural members from reaching critical stresses.
- 5 July 2017
- Published by Springer Nature in Journal of Dynamic Behavior of Materials
- Vol. 3 (3) , 436-460
Design of Experiment and Pitfalls of Low-Velocity Pendulum Impact Testing
- 5 July 2017
- Published by Springer Nature in Journal of Dynamic Behavior of Materials
- Vol. 3 (3) , 436-460
Design of Experiment and Pitfalls of Low-Velocity Pendulum Impact Testing
- 9 June 2017
- Published by Springer Nature in Wood Science and Technology
- Vol. 51 (6) , 1479-1534
State-of-the-art: intermediate and high strain rate testing of solid wood
- 9 June 2017
- Published by Springer Nature in Wood Science and Technology
- Vol. 51 (6) , 1479-1534
State-of-the-art: intermediate and high strain rate testing of solid wood
- 3 March 2017
- Published by Springer Nature in Journal of Dynamic Behavior of Materials
- Vol. 3 (1) , 45-63
What was Timoshenko’s Small-Increment Method? With an Application to Low-Velocity Impact of a Wood Beam
- 3 March 2017
- Published by Springer Nature in Journal of Dynamic Behavior of Materials
- Vol. 3 (1) , 45-63
What was Timoshenko’s Small-Increment Method? With an Application to Low-Velocity Impact of a Wood Beam
- 1 August 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 28 (8)
Low-Velocity Transverse Impact of Small, Clear Spruce and Pine Specimens with Additional Energy Absorbing Treatments
Single-blow impact testing of spruce and pine specimens were done to assess the effects of additional E-glass reinforcing on the tension face of a beam along with a rubber lamina adhered to the impact face. Comparisons between classic three-point static bending and dynamic pendulum tests proved the wood specimens did not absorb more energy in a dynamic loading; conversely, when reinforced with E-glass the spruce specimens absorbed about 2.5 times more energy, and the pine specimens absorbed 1.4 times more energy. The pine specimens treated with rubber and E-glass absorbed only about 1.5 times more energy, indicating a minimal positive effect by adding rubber. The most critical aspect of testing was the strain rate sensitivity of the E-glass.
- 1 August 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 28 (8)
Low-Velocity Transverse Impact of Small, Clear Spruce and Pine Specimens with Additional Energy Absorbing Treatments
Single-blow impact testing of spruce and pine specimens were done to assess the effects of additional E-glass reinforcing on the tension face of a beam along with a rubber lamina adhered to the impact face. Comparisons between classic three-point static bending and dynamic pendulum tests proved the wood specimens did not absorb more energy in a dynamic loading; conversely, when reinforced with E-glass the spruce specimens absorbed about 2.5 times more energy, and the pine specimens absorbed 1.4 times more energy. The pine specimens treated with rubber and E-glass absorbed only about 1.5 times more energy, indicating a minimal positive effect by adding rubber. The most critical aspect of testing was the strain rate sensitivity of the E-glass.
- 19 April 2015
- Published by Springer Nature
- p. 359-372
High-Performance Composite-Reinforced Earthquake Resistant Buildings with Self-Aligning Capabilities
- 19 April 2015
- Published by Springer Nature
- p. 359-372
High-Performance Composite-Reinforced Earthquake Resistant Buildings with Self-Aligning Capabilities
- 9 January 2015
- Published by Springer Nature in European Journal of Wood and Wood Products
- Vol. 73 (2) , 271-273
Numerical calculations of the influence of the slope of grain on the effect of knots
- 9 January 2015
- Published by Springer Nature in European Journal of Wood and Wood Products
- Vol. 73 (2) , 271-273
Numerical calculations of the influence of the slope of grain on the effect of knots
- 1 December 2014
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 28 (6)
Heavy Laminated Timber Frames with Rigid Three-Dimensional Beam-to-Column Connections
This article presents the seismic performance of a timber frame with three-dimensional (3D) rigid connections. The connections were made with self-tapping screws and hardwood blocks were used to support the beams. The frame was designed to resist high seismic excitations with the goal of controlling the drift. The moment-rotation characteristics of the connections were measured in the laboratory by applying static cyclic loads. The frame made of laminated wood beams and columns, and cross-laminated lumber deck, was subjected to seismic, white noise, snapback, and sinusoidal sweep excitations. The synthetic seismic excitation was designed to contain a considerable amount of energy close to the frame’s first natural frequency. The structure showed no significant damage up to a peak ground acceleration of 1.25g. Failure of the frame occurred due to shearing of the columns with a peak ground acceleration of 1.5g. The designed structure fulfilled with current serviceability limits up to 0.8g
- 1 December 2014
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 28 (6)
Heavy Laminated Timber Frames with Rigid Three-Dimensional Beam-to-Column Connections
This article presents the seismic performance of a timber frame with three-dimensional (3D) rigid connections. The connections were made with self-tapping screws and hardwood blocks were used to support the beams. The frame was designed to resist high seismic excitations with the goal of controlling the drift. The moment-rotation characteristics of the connections were measured in the laboratory by applying static cyclic loads. The frame made of laminated wood beams and columns, and cross-laminated lumber deck, was subjected to seismic, white noise, snapback, and sinusoidal sweep excitations. The synthetic seismic excitation was designed to contain a considerable amount of energy close to the frame’s first natural frequency. The structure showed no significant damage up to a peak ground acceleration of 1.25g. Failure of the frame occurred due to shearing of the columns with a peak ground acceleration of 1.5g. The designed structure fulfilled with current serviceability limits up to 0.8g
- 1 December 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 25 (12) , 1898-1909
Evaluation of Remediation Techniques for Circular Holes in the Webs of Wood I-Joists
This is an author's peer-reviewed final manuscript, as accepted by the publisher. The published article is copyrighted by the American Society of Civil Engineers and can be found at: http://ascelibrary.org/journal/jmcee7.Remediation methods and strength predictions were evaluated for wood I-joists with single, circular holes in the webs, leaving utilities in place. A full-scale bending test using four equally-spaced point loads was applied to three depths of joists with varying flange widths and span lengths of 4.88 m and 2.44 m. Failure modes for long span joists without holes were in the flanges in tension, compression or lateral buckling; but once a hole was introduced the majority failed in shear. The curved beam approach and manufacturers software were employed to predict strength. Seven remediation techniques were investigated initially, and remediation effectiveness was evaluated based on strength, stiffness, and ease of installation/cost. The oriented strand board (OSB) collar remediation worked very well and returned 8 out of 12 series of joists to a strength statistically equivalent to the “No Hole” condition. The OSB collar was not quite as effective in returning stiffness to the joists, but was easier to install and less expensive than a laminated strand lumber patch
- 1 December 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 25 (12) , 1898-1909
Evaluation of Remediation Techniques for Circular Holes in the Webs of Wood I-Joists
This is an author's peer-reviewed final manuscript, as accepted by the publisher. The published article is copyrighted by the American Society of Civil Engineers and can be found at: http://ascelibrary.org/journal/jmcee7.Remediation methods and strength predictions were evaluated for wood I-joists with single, circular holes in the webs, leaving utilities in place. A full-scale bending test using four equally-spaced point loads was applied to three depths of joists with varying flange widths and span lengths of 4.88 m and 2.44 m. Failure modes for long span joists without holes were in the flanges in tension, compression or lateral buckling; but once a hole was introduced the majority failed in shear. The curved beam approach and manufacturers software were employed to predict strength. Seven remediation techniques were investigated initially, and remediation effectiveness was evaluated based on strength, stiffness, and ease of installation/cost. The oriented strand board (OSB) collar remediation worked very well and returned 8 out of 12 series of joists to a strength statistically equivalent to the “No Hole” condition. The OSB collar was not quite as effective in returning stiffness to the joists, but was easier to install and less expensive than a laminated strand lumber patch