María Teresa Baeza-Romero

María Teresa Baeza-Romero

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


María Teresa Baeza-Romero has a total of 231 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ambient, Indoor Air Pollution Exposures and Mild Chronic Obstructive Pulmonary Disease Trajectories in Non-Hospitalized Volunteers in Turin, Italy

    by Ornella Salimbene, Nicola Leoce, Ivano Salimbene, María Teresa Baeza-Romero, Deborah Panepinto, Gregor Čok

    Urban air pollution is a key driver of adverse respiratory outcomes, yet its precise impact on lung function trajectories in non-hospitalized patients with mild chronic obstructive pulmonary disease (COPD) has not been fully characterized. Objectives: This study investigated the complex interplay between ambient particulate matter exposure, residential microenvironmental factors, sociodemographic characteristics, and 1-year longitudinal lung function in mild COPD patients. Methods: A 1-year prospective cohort study was conducted on 50 non-hospitalized male volunteers residing in Turin (Italy) for a minimum of 5 consecutive years. Longitudinal lung function was assessed monthly via spirometric parameters, including forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), and the FEV1/FVC ratio. Ambient PM concentrations assigned according to residential location (PM2.5 and PM10) were integrated with a comprehensive residential microenvironmental and lifestyle profiling. To assess longitudinal changes in lung function while controlling for covariates, a Multivariate Analysis of Covariance (MANCOVA) was applied to estimate the simultaneous effects of these predictors on the joint lung function parameters over time. To fully account for the nested, repeated-measures structure of the dataset, linear mixed-effects models (LMMs) were deployed to calculate specific rates of functional decline over the 12 monthly intervals. This model assessed multiple exposure variables, including cooking appliances (gas vs. electric), domestic heating systems (internal vs. external boilers), smoking status, traffic exposure, and pets. Statistical associations were modeled using Principal Component Analysis (PCA) and Agglomerative Hierarchical Clustering (AHC). Results: The MANCOVA revealed a highly significant overall multivariate effect of the combined predictors on the joint lung function parameters (Wilks’ λ = 0.125, p < 0.001). Specifically, monthly PM2.5 concentrations (p = 0.001), residential proximity to primary roads (p = 0.004), and the utilization of gas-fueled cooking appliances (p = 0.002) exerted statistically significant independent effects on the decline in the spirometric profile, whereas PM10 and internal boilers did not (p > 0.05). PCA then identified four significant components explaining 88.8% of the total variance, demonstrating collinearity between ambient PM2.5 and PM10 concentrations and revealing that spatial residential distribution significantly accounts for the longitudinal variability in FEV1 and FVC. Furthermore, AHC successfully identified distinct patient clusters, confirming that indoor microenvironmental factors—predominantly the utilization of gas-fueled cooking stoves and internal boilers—could act as critical compounding risk factors alongside outdoor traffic pollution. Conclusions: These preliminary findings suggest how intersecting urban outdoor pollutants and specific household factors may potentially contribute to the trajectories of mild COPD. These data underscore the potential benefit of integrated environmental-indoor risk assessment methodologies and may inform future targeted public health interventions and preventive strategies to mitigate exacerbations in vulnerable urban populations.

  • Open Access

    Discrepancies in indoor air-cleaner performance reporting for air pollutants: implications and a standardized framework

    by María Teresa Baeza-Romero, Sascha Nehr, John Saffell, Sotirios Papathanasiou, Kostas Karatzas, Cristiana Costa Pereira, Marzenna R. Dudzinska, Giannis Papadopoulos, Sofia I.V. Sousa, Giorgos Panaras

  • Open Access

    Comment on egusphere-2026-3918

    by Anouk Marsal, Fabrizia Cavalli, Elise Di Antonio, Stephan Houdier, Pamela Dominutti, Sophie Darfeuil, Jean-Luc Jaffrezo, Stéphane Sauvage, Jean-Philippe Putaud, Ian S. Mudway, et al.

    Oxidative potential (OP) of atmospheric particulate matter (PM) is a metric of increasing scientific interest because it potentially links chemical particle properties to particle health effects. OP has been recently introduced as a recommended monitoring metric in the European Air Quality Directive. However, inconsistent protocols in the existing literature make it difficult to compare results across studies. Following a 2023 inter-laboratory comparison that focused on PM OP measured using the dithiothreitol (DTT) assay, this paper presents the findings and lessons learnt from a second inter-laboratory study focused on the ascorbic acid assay (OP-AA). In this study, twenty-six laboratories worldwide quantified OP of four PM filter samples and of one chemical compound to evaluate the entire analytical chain, including the extraction step, using a simplified OP-AA protocol. While most laboratories produced repeatable internal results when applying the simplified protocol, significant discrepancies between participants highlight the need for each laboratory to carefully evaluate deviations from the simplified OP-AA protocol. Over half of the 26 participants achieved satisfactory results, suggesting that the protocol is suitable for large-scale implementation. Beyond assessing performance, this work investigates technical, analytical, and mathematical refinements to measurement protocols. Building on the first DTT assay study, this second inter-laboratory comparison represents a significant step toward harmonizing OP assays, and provides specific recommendations to ensure consistent future measurements, ready to be applied in the new air quality directive EU 2024/2881.

  • Open Access

    Comment on egusphere-2026-3918

    by Anouk Marsal, Fabrizia Cavalli, Elise Di Antonio, Stephan Houdier, Pamela Dominutti, Sophie Darfeuil, Jean-Luc Jaffrezo, Stéphane Sauvage, Jean-Philippe Putaud, Ian S. Mudway, et al.

    Oxidative potential (OP) of atmospheric particulate matter (PM) is a metric of increasing scientific interest because it potentially links chemical particle properties to particle health effects. OP has been recently introduced as a recommended monitoring metric in the European Air Quality Directive. However, inconsistent protocols in the existing literature make it difficult to compare results across studies. Following a 2023 inter-laboratory comparison that focused on PM OP measured using the dithiothreitol (DTT) assay, this paper presents the findings and lessons learnt from a second inter-laboratory study focused on the ascorbic acid assay (OP-AA). In this study, twenty-six laboratories worldwide quantified OP of four PM filter samples and of one chemical compound to evaluate the entire analytical chain, including the extraction step, using a simplified OP-AA protocol. While most laboratories produced repeatable internal results when applying the simplified protocol, significant discrepancies between participants highlight the need for each laboratory to carefully evaluate deviations from the simplified OP-AA protocol. Over half of the 26 participants achieved satisfactory results, suggesting that the protocol is suitable for large-scale implementation. Beyond assessing performance, this work investigates technical, analytical, and mathematical refinements to measurement protocols. Building on the first DTT assay study, this second inter-laboratory comparison represents a significant step toward harmonizing OP assays, and provides specific recommendations to ensure consistent future measurements, ready to be applied in the new air quality directive EU 2024/2881.

  • Open Access

    Supplementary material to "Harmonizing measurements of oxidative potential of PM: an interlaboratory comparison of the ascorbic acid assay"

    by Anouk Marsal, Fabrizia Cavalli, Elise Di Antonio, Stephan Houdier, Pamela Dominutti, Sophie Darfeuil, Jean-Luc Jaffrezo, Stéphane Sauvage, Jean-Philippe Putaud, Ian S. Mudway, et al.

  • Open Access

    Harmonizing measurements of oxidative potential of PM: an interlaboratory comparison of the ascorbic acid assay

    by Anouk Marsal, Fabrizia Cavalli, Elise Di Antonio, Stephan Houdier, Pamela Dominutti, Sophie Darfeuil, Jean-Luc Jaffrezo, Stéphane Sauvage, Jean-Philippe Putaud, Ian S. Mudway, et al.

    Oxidative potential (OP) of atmospheric particulate matter (PM) is a metric of increasing scientific interest because it potentially links chemical particle properties to particle health effects. OP has been recently introduced as a recommended monitoring metric in the European Air Quality Directive. However, inconsistent protocols in the existing literature make it difficult to compare results across studies. Following a 2023 inter-laboratory comparison that focused on PM OP measured using the dithiothreitol (DTT) assay, this paper presents the findings and lessons learnt from a second inter-laboratory study focused on the ascorbic acid assay (OP-AA). In this study, twenty-six laboratories worldwide quantified OP of four PM filter samples and of one chemical compound to evaluate the entire analytical chain, including the extraction step, using a simplified OP-AA protocol. While most laboratories produced repeatable internal results when applying the simplified protocol, significant discrepancies between participants highlight the need for each laboratory to carefully evaluate deviations from the simplified OP-AA protocol. Over half of the 26 participants achieved satisfactory results, suggesting that the protocol is suitable for large-scale implementation. Beyond assessing performance, this work investigates technical, analytical, and mathematical refinements to measurement protocols. Building on the first DTT assay study, this second inter-laboratory comparison represents a significant step toward harmonizing OP assays, and provides specific recommendations to ensure consistent future measurements, ready to be applied in the new air quality directive EU 2024/2881.

  • Open Access

    Highly sensitive ammonia sensing at room temperature with Ce/Pr mixed oxide/oxidized MWCNT composite

    by Jhon Mauricio Aguirre-Cortés, Miriam Villa-Díaz, María Teresa Baeza-Romero, José Solla-Gullón, Edelmira Valero

  • Open Access

    Discrepancies in indoor air-cleaner performance reporting for air pollutants: implications and a standardized framework

    by Maria Teresa Baeza_Romero, Sascha Nehr, John Saffell, Sotirios Papathanasiou, Kostas Karatzas, Cristiana Costa Pereira, Marzenna Dudzinska, Giannis Papadopoulos, Sofia Sousa, Giorgos Panaras

    The rapid growth of the indoor air-cleaner market has introduced significant variability in how pollutant removal performance is reported, limiting the ability to evaluate these technologies as environmental mitigation tools. This study presents a data-driven analysis of 413 commercially available indoor air-cleaning devices, systematically assessing the reporting of particulate matter, gas-phase pollutants (including volatile organic compounds), and biological removal claims. The results reveal widespread inconsistencies, including the use of terms such as “HEPA” without filter class or test reference, gas-phase claims lacking compound specificity or test conditions, and biological efficacy claims without quantitative metrics or defined methods. In addition, key parameters such as operating conditions, energy use, acoustics, and potential by-product emissions are frequently incompletely reported. These limitations hinder the interpretation of air-cleaner performance and may lead to misestimation of pollutant removal effectiveness under real indoor conditions. To address these issues, a harmonized taxonomy and a Minimum Technical Data Sheet (mTDS) are defined, providing a structured framework for transparent and comparable reporting of performance and technical specifications. This approach supports improved interpretation of pollutant removal processes and more reliable assessment of indoor air-cleaning technologies in the context of environmental quality and exposure mitigation.

  • Open Access

    Evaluation of analytical techniques for organic peroxide measurements in polar and non-polar systems.

    by Daniel Alba-Elena, Xinke Wang, Jonathan Abbatt, Edelmira Valero, Maria Teresa Baeza-Romero

    Peroxides and hydroperoxides are generated during the oxidation of volatile organic compounds (VOCs) in both gaseous and aqueous phases. The ozonolysis of alkenes in the gas phase is a significant source of peroxy radicals (RO2) in both nocturnal and diurnal chemistry. In the absence of NO, the recombination reactions of RO2 radicals lead to the formation of H2O2 and/or organic hydroperoxides (Atkinson, 2000). Hydroperoxides are highly reactive and play a crucial role in atmospheric chemistry, such as the oxidation of SO2 to H2SO4 in atmospheric aqueous droplets and heterogeneous SO2 uptake (Wang, 2021). Moreover, peroxides are suggested to constitute a significant fraction of laboratory-generated secondary organic aerosol (SOA) (Docherty 2005) and can serve as reservoirs of HOx and ROx radicals (Li, 2016).Various spectrophotometric methods have been employed to quantify SOA-bound peroxides offline. The Iodometry method quantifies peroxides present in any form (H2O2, ROOH, and ROOR) except for tertiary dialkyl peroxides. The principle of the method is A faster and more sensitive alternative to this method was developed by our group, which accelerates the reaction by microwave heating (Alba-Elena, 2023). These assays typically use water as a solvent. Here, for the first time, an alternative procedure using 1-propanol as an organic solvent is proposed and tested for H2O2 and various less reactive peroxides.Other spectrophotometric methods include: the 4-nitrophenyl boronic acid (NPBA) assay, which is based on the reaction between the hydroperoxide and NPBA to form the colored nitrophenol, the absorbance of which is measured (Jiang, 2017), and the Fenton reaction-assisted ferrous-xylenol (FOX2) assay, which is based on the oxidation of Fe2+ by the organic hydroperoxide to form Fe3+, which forms a complex with Xylenol orange that can be detected spectrometrically (Morrison, 2023).All these assays, as well as the 2,7-dichlorofluorescein-based horseradish peroxidase (DCF-HRP) assay, a widely used fluorescence method that is more sensitive to H2O2 compared to other organic peroxides and hydroperoxides (Badali, 2015), have been tested using water and polar organic solvents such as 1-propanol and non-polar organic solvents such as chloroform. Their response to different types of peroxide: H2O2, tertbutyl hydroperoxide, ditertbutyl peroxide, methyl ethyl ketone peroxide, and dibenzoyl peroxide, has been evaluated. A comparative study of the results, their different characteristics, and their possible interferences has been conducted. ACKNOWLEDGEMENTThis research was supported by the Spanish Ministry of Science, Innovation and Universities (MICINN, https://www.ciencia.gob.es/) with grants PID2019-106468RB-I00 and PID2022-139724OB-I00, funded by MCIN/AEI/10.13039/501100011033 and co-funded by the European Union; the UCLM groups research grant No. 2022-GRIN-34199, funded by the own research plan of the UCLM for applied research projects, co-financed by the European Fund for Regional Development (FEDER). D. Alba thanks MCIN/AEI for his “Contrato Predoctoral” Ref BES-2020-094874 associated to the project indicated.

  • Selective and highly sensitive measurement of H2O2 and organic hydroperoxides with PtNP/Poly(Brilliant Green)/SPCE

    by Sergio Blázquez, Rebeca Jiménez-Pérez, José González-Rodríguez, María-Isabel González-Sánchez, María Teresa Baeza-Romero, Edelmira Valero