Bin Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bin Han has a total of 144 co-authors. Here are the top co-authors by number of shared publications:
Lei Xing
Department of Radiation Oncology, Stanford University, Stanford, California
11 shared publications- Lei Xing
Stanford University
9 shared publications Bryan Bednarz
Massachusetts General Hospital, Department of Radiation Oncology Boston, Massachusetts 02140
4 shared publications- Daniel T. Chang
Department of Radiation Oncology, University of Michigan, Ann Arbor, MI 48103, USA
4 shared publications - Lucas Kas Vitzthum
Department of Radiation Oncology, Stanford University, Stanford, California
4 shared publications M. Narayanan
RefleXion Medical, Inc., Hayward, CA
4 shared publications
Latest Publications
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e61-e62
Analysis of the Measured FDG Uptake from the First-in-Human Clinical Trial of Biology-Guided Radiotherapy
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e61-e62
Analysis of the Measured FDG Uptake from the First-in-Human Clinical Trial of Biology-Guided Radiotherapy
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e722
Dosimetric Accuracy of Multi-Target Biology-Guided Radiotherapy Treatments in a Single Session
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e722
Dosimetric Accuracy of Multi-Target Biology-Guided Radiotherapy Treatments in a Single Session
- Open Access
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e668-e669
Characterization of Biology-Guided Radiotherapy Accuracy as a Function of PET Tracer Uptake
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e668-e669
Open AccessCharacterization of Biology-Guided Radiotherapy Accuracy as a Function of PET Tracer Uptake
- 2 May 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , 505-514
Patient-Specific Auto-segmentation on Daily kVCT Images for Adaptive Radiation Therapy
- 2 May 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , 505-514
Patient-Specific Auto-segmentation on Daily kVCT Images for Adaptive Radiation Therapy
- 15 November 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1141) , 20220387
Image-mode performance characterisation of a positron emission tomography subsystem designed for Biology-guided radiotherapy (BgRT)
Objectives: In this study, we characterise the imaging-mode performance of the positron emission tomography (PET) subsystem of the RefleXion X1 machine using the NEMA NU-2 2018 standard. Methods: The X1 machine consists of two symmetrically opposing 900 arcs of PET detectors incorporated into the architecture of a ring-gantry linear accelerator rotating up to 60 RPM. PET emissions from a tumour are detected by the PET detectors and used to guide the delivery of radiation beam. Imaging performance of the PET subsystem on X1 machine was evaluated based on sensitivity of the PET detectors, spatial resolution, count-loss performance, image quality, and daily system performance check. Results: PET subsystem sensitivity was measured as 0.183 and 0.161 cps/kBq at the center and off-center positions, respectively. Spatial resolution: average FWHM values of 4.3, 5.1, and 6.7 mm for the point sources at 1, 10, and 20 cm off center, respectively were recorded. For count loss, max NECR: 2.63 kcps, max true coincidence rate: 5.56 kcps, and scatter fraction: 39.8%. The 10 mm sphere was not visible. Image-quality contrast values were: 29.6%, 64.9%, 66.5%, 81.8%, 81.2%, and background variability: 14.8%, 12.4%, 10.3%, 8.8%, 8.3%, for the 13, 17, 22, 28, 37 mm sphere sizes, respectively. Conclusions: When operating in an imaging mode, the spatial resolution and image contrast of the X1 PET subsystem were comparable to those of typical diagnostic imaging systems for large spheres, while the sensitivity and count rate were lower due to the significantly smaller PET detector area in the X1 system. Clinical efficacy when used in BgRT remains to be validated. Advances in knowledge: This is the first performance evaluation of the PET subsystem on the novel BgRT machine. The dual arcs rotating PET subsystem on RefleXion X1 machine performance is comparable to those of the typical diagnostic PET system based on the spatial resolution and image contrast for larger spheres.
- 15 November 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1141) , 20220387
Image-mode performance characterisation of a positron emission tomography subsystem designed for Biology-guided radiotherapy (BgRT)
Objectives: In this study, we characterise the imaging-mode performance of the positron emission tomography (PET) subsystem of the RefleXion X1 machine using the NEMA NU-2 2018 standard. Methods: The X1 machine consists of two symmetrically opposing 900 arcs of PET detectors incorporated into the architecture of a ring-gantry linear accelerator rotating up to 60 RPM. PET emissions from a tumour are detected by the PET detectors and used to guide the delivery of radiation beam. Imaging performance of the PET subsystem on X1 machine was evaluated based on sensitivity of the PET detectors, spatial resolution, count-loss performance, image quality, and daily system performance check. Results: PET subsystem sensitivity was measured as 0.183 and 0.161 cps/kBq at the center and off-center positions, respectively. Spatial resolution: average FWHM values of 4.3, 5.1, and 6.7 mm for the point sources at 1, 10, and 20 cm off center, respectively were recorded. For count loss, max NECR: 2.63 kcps, max true coincidence rate: 5.56 kcps, and scatter fraction: 39.8%. The 10 mm sphere was not visible. Image-quality contrast values were: 29.6%, 64.9%, 66.5%, 81.8%, 81.2%, and background variability: 14.8%, 12.4%, 10.3%, 8.8%, 8.3%, for the 13, 17, 22, 28, 37 mm sphere sizes, respectively. Conclusions: When operating in an imaging mode, the spatial resolution and image contrast of the X1 PET subsystem were comparable to those of typical diagnostic imaging systems for large spheres, while the sensitivity and count rate were lower due to the significantly smaller PET detector area in the X1 system. Clinical efficacy when used in BgRT remains to be validated. Advances in knowledge: This is the first performance evaluation of the PET subsystem on the novel BgRT machine. The dual arcs rotating PET subsystem on RefleXion X1 machine performance is comparable to those of the typical diagnostic PET system based on the spatial resolution and image contrast for larger spheres.
- Open Access
- 28 April 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (6) , e13607
Beam commissioning of the first clinical biology‐guided radiotherapy system
This study reports the beam commissioning results for the first clinical RefleXion Linac.Methods: The X1 produces a 6 MV photon beam and the maximum clinical field size is 40 × 2 cm2 at source‐to‐axis distance of 85 cm. Treatment fields are collimated by a binary multileaf collimator (MLC) system with 64 leaves with width of 0.625 cm and y‐jaw pairs to provide either a 1 or 2 cm opening. The mechanical alignment of the radiation source, the y‐jaw, and MLC were checked with film and ion chambers. The beam parameters were characterized using a diode detector in a compact water tank. In‐air lateral profiles and in‐water percentage depth dose (PDD) were measured for beam modeling of the treatment planning system (TPS). The lateral profiles, PDDs, and output factors were acquired for field sizes from 1.25 × 1 to 40 × 2 cm2 field to verify the beam modeling. The rotational output variation and synchronicity were tested to check the gantry angle, couch motion, and gantry rotation.Results: The source misalignments were 0.049 mm in y‐direction, 0.66% out‐of‐focus in x‐direction. The divergence of the beam axis was 0.36 mm with a y‐jaw twist of 0.03°. Clinical off‐axis treatment fields shared a common center in y‐direction were within 0.03 mm. The MLC misalignment and twist were 0.57 mm and 0.15°. For all measured fields ranging from the size from 1.25 × 1 to 40 × 2 cm2, the mean difference between measured and TPS modeled PDD at 10 cm depth was −0.3%. The mean transverse profile difference in the field core was −0.3% ± 1.1%. The full‐width half maximum (FWHM) modeling was within 0.5 mm. The measured output factors agreed with TPS within 0.8%.Conclusions: This study summarizes our specific experience commissioning the first novel RefleXion linac, which may assist future users of this technology when implementing it into their own clinics.
- 28 April 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (6) , e13607
Open AccessBeam commissioning of the first clinical biology‐guided radiotherapy system
This study reports the beam commissioning results for the first clinical RefleXion Linac.Methods: The X1 produces a 6 MV photon beam and the maximum clinical field size is 40 × 2 cm2 at source‐to‐axis distance of 85 cm. Treatment fields are collimated by a binary multileaf collimator (MLC) system with 64 leaves with width of 0.625 cm and y‐jaw pairs to provide either a 1 or 2 cm opening. The mechanical alignment of the radiation source, the y‐jaw, and MLC were checked with film and ion chambers. The beam parameters were characterized using a diode detector in a compact water tank. In‐air lateral profiles and in‐water percentage depth dose (PDD) were measured for beam modeling of the treatment planning system (TPS). The lateral profiles, PDDs, and output factors were acquired for field sizes from 1.25 × 1 to 40 × 2 cm2 field to verify the beam modeling. The rotational output variation and synchronicity were tested to check the gantry angle, couch motion, and gantry rotation.Results: The source misalignments were 0.049 mm in y‐direction, 0.66% out‐of‐focus in x‐direction. The divergence of the beam axis was 0.36 mm with a y‐jaw twist of 0.03°. Clinical off‐axis treatment fields shared a common center in y‐direction were within 0.03 mm. The MLC misalignment and twist were 0.57 mm and 0.15°. For all measured fields ranging from the size from 1.25 × 1 to 40 × 2 cm2, the mean difference between measured and TPS modeled PDD at 10 cm depth was −0.3%. The mean transverse profile difference in the field core was −0.3% ± 1.1%. The full‐width half maximum (FWHM) modeling was within 0.5 mm. The measured output factors agreed with TPS within 0.8%.Conclusions: This study summarizes our specific experience commissioning the first novel RefleXion linac, which may assist future users of this technology when implementing it into their own clinics.
- Open Access
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , e532-e533
The kVCT System Commissioning of a Novel Medical Linear Accelerator Designed for Biology-Guided Radiotherapy
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , e532-e533
Open AccessThe kVCT System Commissioning of a Novel Medical Linear Accelerator Designed for Biology-Guided Radiotherapy
- Open Access
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , e515-e516
Comparison of a First-in-Class LINAC-Integrated PET System and a Diagnostic PET/CT Scanner
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , e515-e516
Open AccessComparison of a First-in-Class LINAC-Integrated PET System and a Diagnostic PET/CT Scanner
- 10 October 2021
- Published by Wiley in Medical Physics
- Vol. 48 (11) , 7450-7460
Small‐field measurement and Monte Carlo model validation of a novel image‐guided radiotherapy system
Purpose: The RefleXion™ X1 is a novel radiotherapy system that is designed for image‐guided radiotherapy, and eventually, biology‐guided radiotherapy (BgRT). BgRT is a treatment paradigm that tracks tumor motion using real‐time positron emission signals. This study reports the small‐field measurement results and the validation of a Monte Carlo (MC) model of the first clinical RefleXion unit.Methods: The RefleXion linear accelerator (linac) produces a 6 MV flattening filter free (FFF) photon beam and consists of a binary multileaf collimator (MLC) system with 64 leaves and two pairs of y‐jaws. The maximum clinical field size achievable is 400 × 20 mm2. The y‐jaws provide either a 10 or 20 mm opening at source‐to‐axis distance (SAD) of 850 mm. The width of each MLC leaf at SAD is 6.25 mm. Percentage depth doses (PDDs) and relative beam profiles were acquired using an Edge diode detector in a water tank for field sizes from 12.5 × 10 to 100 × 20 mm2. Beam profiles were also measured using films. Output factors of fields ranging from 6.25 × 10 to 100 × 20 mm2 were measured using W2 scintillator detector, Edge detector, and films. Output correction factors k of the Edge detector for RefleXion were calculated. An MC model of the linac including pre‐MLC beam sources and detailed structures of MLC and lower y‐jaws was validated against the measurements. Simulation codes BEAMnrc and GATE were utilized.Results: The diode measured PDD at 10 cm depth (PDD10) increases from 53.6% to 56.9% as the field opens from 12.5 × 10 to 100 × 20 mm2. The W2‐measured output factor increases from 0.706 to 1 as the field opens from 6.25 × 10 to 100 × 20 mm2 (reference field size). The output factors acquired by diode and film differ from the W2 results by 1.65% (std = 1.49%) and 2.09% (std = 1.41%) on average, respectively. The profile penumbra and full‐width half‐maximum (FWHM) measured by diode agree well with the film results with a deviation of 0.60 mm and 0.73% on average, respectively. The averaged beam profile consistency calculated between the diode‐ and film‐measured profiles among different depths is within 1.72%. By taking the W2 measurements as the ground truth, the output correction factors k for Edge detector ranging from 0.958 to 1 were reported. For the MC model validation, the simulated PDD10 agreed within 0.6% to the diode measurement. The MC‐simulated output factor differed from the W2 results by 2.3% on average (std = 3.7%), while the MC simulated beam penumbra differed from the diode results by 0.67 mm on average (std = 0.42 mm). The MC FWHM agreed with the diode results to within 1.40% on average. The averaged beam profile consistency calculated between the diode and MC profiles among different depths is less than 1.29%.Conclusions: This study represents the first small‐field dosimetry of a clinical RefleXion system. A complete and accurate MC model of the RefleXion linac has been validated.
- 10 October 2021
- Published by Wiley in Medical Physics
- Vol. 48 (11) , 7450-7460
Small‐field measurement and Monte Carlo model validation of a novel image‐guided radiotherapy system
Purpose: The RefleXion™ X1 is a novel radiotherapy system that is designed for image‐guided radiotherapy, and eventually, biology‐guided radiotherapy (BgRT). BgRT is a treatment paradigm that tracks tumor motion using real‐time positron emission signals. This study reports the small‐field measurement results and the validation of a Monte Carlo (MC) model of the first clinical RefleXion unit.Methods: The RefleXion linear accelerator (linac) produces a 6 MV flattening filter free (FFF) photon beam and consists of a binary multileaf collimator (MLC) system with 64 leaves and two pairs of y‐jaws. The maximum clinical field size achievable is 400 × 20 mm2. The y‐jaws provide either a 10 or 20 mm opening at source‐to‐axis distance (SAD) of 850 mm. The width of each MLC leaf at SAD is 6.25 mm. Percentage depth doses (PDDs) and relative beam profiles were acquired using an Edge diode detector in a water tank for field sizes from 12.5 × 10 to 100 × 20 mm2. Beam profiles were also measured using films. Output factors of fields ranging from 6.25 × 10 to 100 × 20 mm2 were measured using W2 scintillator detector, Edge detector, and films. Output correction factors k of the Edge detector for RefleXion were calculated. An MC model of the linac including pre‐MLC beam sources and detailed structures of MLC and lower y‐jaws was validated against the measurements. Simulation codes BEAMnrc and GATE were utilized.Results: The diode measured PDD at 10 cm depth (PDD10) increases from 53.6% to 56.9% as the field opens from 12.5 × 10 to 100 × 20 mm2. The W2‐measured output factor increases from 0.706 to 1 as the field opens from 6.25 × 10 to 100 × 20 mm2 (reference field size). The output factors acquired by diode and film differ from the W2 results by 1.65% (std = 1.49%) and 2.09% (std = 1.41%) on average, respectively. The profile penumbra and full‐width half‐maximum (FWHM) measured by diode agree well with the film results with a deviation of 0.60 mm and 0.73% on average, respectively. The averaged beam profile consistency calculated between the diode‐ and film‐measured profiles among different depths is within 1.72%. By taking the W2 measurements as the ground truth, the output correction factors k for Edge detector ranging from 0.958 to 1 were reported. For the MC model validation, the simulated PDD10 agreed within 0.6% to the diode measurement. The MC‐simulated output factor differed from the W2 results by 2.3% on average (std = 3.7%), while the MC simulated beam penumbra differed from the diode results by 0.67 mm on average (std = 0.42 mm). The MC FWHM agreed with the diode results to within 1.40% on average. The averaged beam profile consistency calculated between the diode and MC profiles among different depths is less than 1.29%.Conclusions: This study represents the first small‐field dosimetry of a clinical RefleXion system. A complete and accurate MC model of the RefleXion linac has been validated.
- 14 September 2021
- Published by Wiley in Medical Physics
- Vol. 48 (11) , 6810-6819
Deep learning‐enabled EPID‐based 3D dosimetry for dose verification of step‐and‐shoot radiotherapy
Purpose: The study aims at a novel dosimetry methodology to reconstruct a 3D dose distribution as imparted to a virtual cylindrical phantom using an electronic portal imaging device (EPID).Methods: A deep learning‐based signal processing strategy, referred to as 3DosiNet, is utilized to learn a mapping from an EPID image to planar dose distributions at given depths. The network was trained with the volumetric dose exported from the clinical treatment planning system (TPS). Given the latent inconsistency between measurements and corresponding TPS calculations, unsupervised learning is formulated in 3DosiNet to capture abstractive image features that are less sensitive to the potential variations.Results: Validation experiments were performed using five regular fields and three clinical intensity‐modulated radiation therapy (IMRT) cases. The measured dose profiles and percentage depth dose (PDD) curves were compared with those measured using standard tools in terms of the 1D gamma index. The mean gamma pass rates (2%/2 mm) over the regular fields are 100% and 97.3% for the dose profile and PDD measurements, respectively. The measured volumetric dose was compared to the corresponding TPS calculation in terms of the 3D gamma index. The mean 2%/2 mm gamma pass rates are 97.9% for square fields and 94.9% for the IMRT fields.Conclusions: The system promises to be a practical 3D dosimetric tool for pre‐treatment patient‐specific quality assurance and further developed for in‐treatment patient dose monitoring.
- 14 September 2021
- Published by Wiley in Medical Physics
- Vol. 48 (11) , 6810-6819
Deep learning‐enabled EPID‐based 3D dosimetry for dose verification of step‐and‐shoot radiotherapy
Purpose: The study aims at a novel dosimetry methodology to reconstruct a 3D dose distribution as imparted to a virtual cylindrical phantom using an electronic portal imaging device (EPID).Methods: A deep learning‐based signal processing strategy, referred to as 3DosiNet, is utilized to learn a mapping from an EPID image to planar dose distributions at given depths. The network was trained with the volumetric dose exported from the clinical treatment planning system (TPS). Given the latent inconsistency between measurements and corresponding TPS calculations, unsupervised learning is formulated in 3DosiNet to capture abstractive image features that are less sensitive to the potential variations.Results: Validation experiments were performed using five regular fields and three clinical intensity‐modulated radiation therapy (IMRT) cases. The measured dose profiles and percentage depth dose (PDD) curves were compared with those measured using standard tools in terms of the 1D gamma index. The mean gamma pass rates (2%/2 mm) over the regular fields are 100% and 97.3% for the dose profile and PDD measurements, respectively. The measured volumetric dose was compared to the corresponding TPS calculation in terms of the 3D gamma index. The mean 2%/2 mm gamma pass rates are 97.9% for square fields and 94.9% for the IMRT fields.Conclusions: The system promises to be a practical 3D dosimetric tool for pre‐treatment patient‐specific quality assurance and further developed for in‐treatment patient dose monitoring.