YZYing Zou

Ying Zou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ying Zou has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Yong Wang

    Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai, China

    6 shared publications
  • Renzhong Tai

    Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China

    3 shared publications
  • Huaina Yu

    Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China

    2 shared publications
  • Xiangzhi Zhang

    Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China

    2 shared publications
  • Yanqing Wu

    Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences Shanghai China

    2 shared publications
  • Zhenhua Chen

    Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China

    2 shared publications

Latest Publications

  • Confined-walking mode for an elliptical polarized undulator and its application

    by Ying Zou, Qinglei Zhang, Jidong Zhang, Jingwei Zhuo, Geyang Jiang, Ping Liu, Bocheng Jiang, Lifang Zheng, Qiaogen Zhou, Lixin Yin, et al.

    Elliptical polarized undulators (EPUs) are broadly used in the soft X-ray energy range. They have the advantage of providing photons with both varied energy and polarization through adjustments to the value of the gap and/or shift magnet arrays in an undulator. Yet these adjustments may create a disturbance on the stability of the electron beam in a storage ring. To correct such a disturbance, it is necessary to establish a feed-forward table of key nodes in the gap-shift-defined two-dimensional parameter space. Such a table can only be scanned during machine-study time. For a free-walking mode, whereby an undulator is allowed to manoeuvre in the whole gap-shift space, all the key nodes need to be scanned at the expense of a large amount of machine-study time. This will greatly delay the employment of a full-polarization capable undulator (especially circularly polarized). By analyzing data-collecting patterns of user experiments, this paper defines a reduced set of key nodes in gap-shift parameter space, with the number of key nodes to be scanned for feed-forwarding scaled down to one-third of the original; and introduces a new walking mode for EPUs: confined-walking mode, whereby the undulator is manoeuvred only within the reduced set of key nodes. Such a mode is firstly realized on the EPUs at the DREAMLINE beamline at Shanghai Synchrotron Radiation Facility (SSRF). Under confined-walking mode, the undulator movements are stable and there is no obvious disturbance to the electron beam with the feed-forward system in operation. Successful experiments have been carried out using the circularly polarized light obtained via the new walking mode. This mode is expected to be applied to future EPUs at SSRF with the increasing requirements for various polarization modes.


  • Soft x-ray spectroscopic endstation at beamline 08U1A of Shanghai Synchrotron Radiation Facility

    by Haigang Liu, Jiefeng Cao, Yong Wang, Zhenhua Chen, Huaina Yu, Lijuan Zhang, Zijian Xu, Zhi Guo, Xiangzhi Zhang, Xiangjun Zhen, et al.

    A spectroscopic endstation with magnetic field, voltage, and low temperature control has been installed and commissioned at the soft X-ray beamline 08U1A of Shanghai Synchrotron Radiation Facility, which can obtain a magnetic field up to ±0.53 T, applied current and bias voltage, and cryogenic temperatures down to 14 K with a Gifford-McMahon cycle cryocooler. The endstation can perform soft X-ray absorption spectroscopy methods including total electron yield, fluorescence yield, and X-ray excited optical luminance. Combined with an elliptically polarized undulator and the in situ conditions, the endstation can effectively perform X-ray magnetic circular and linear dichroism experiments in the soft X-ray range between photon energies of 250 and 2000 eV.


  • Design of wide-range energy material beamline at the Shanghai Synchrotron Radiation Facility

    by Zhen-Hua Chen, Fan-Fei Sun, Ying Zou, Fei Song, Shuo Zhang, Zheng Jiang, Yong Wang, Ren-Zhong Tai


  • Optimization of the design for beamline with fast polarization switching elliptically polarized undulators

    by Jiefeng Cao, Yong Wang, Ying Zou, Xiangzhi Zhang, Yanqing Wu, Renzhong Tai

    Fast switching of X-ray polarization with a lock-in amplifier is a good method for acquiring weak signals from background noise for X-ray magnetic circular dichroism (XMCD) experiments. The usual way to obtain a beam with fast polarization switching is to use two series of elliptically polarized undulators (tandem twin EPUs). The two EPUs generate two individual beams. Each beam has a different polarization and is fast switched into the beamline. It is very important to ensure that the energy resolution, the flux and the spot size at the sample of the two beams are equal in XMCD experiments. However, it is difficult in beamline design because the distances from the two EPUs to the beamline optics are different and the beamline is not switchable. In this work, a beamline design without an entrance slit for fast polarization switching EPUs is discussed. The energy resolution of the two beams can be tuned to be equal by minor rotation of the optics in the monochromator. The flux of the two beams can be balanced through separation bladesX, Yin the exit slit, and by adjusting the position of theXblades along the beam. The spot size of the two beams can be adjusted to be equal by shifting the sample as well.


  • Open Access

    A new extra-focus monochromator designed for high-performance VUV beamlines

    by Chaofan Xue, Yanqing Wu, Ying Zou, Lian Xue, Yong Wang, Zijian Xu, Renzhong Tai

    A new monochromator called an extra-focus constant-included-angle varied-line-spacing (VLS) cylindrical-grating monochromator (extra-focus CIA-VCGM) is described. This monochromator is based on the Hettrick–Underwood scheme where the plane VLS grating is replaced by a cylindrical one in order to zero the defocus at three reference photon energies in the vacuum-ultraviolet range. It has a simple mechanical structure and a fixed focus spot with high performance over a wide energy range. Furthermore, its mechanical compatibility with a standard VLS plane-grating monochromator allows convenient extension into the soft-X-ray range.


  • Development of a XEOL detection system for the scanning transmission X-ray microscopy beamline at the Shanghai Synchrotron Radiation Facility

    by Huaina Yu, Zhenhua Chen, Xiangyu Meng, Yong Wang, Ying Zou, Renzhong Tai, Yuting Nie, Xuhui Sun

    We describe the design and capabilities of the x-ray excited optical luminescence (XEOL) technique at the scanning transmission x-ray microscopy beamline (BL08U1A) of the Shanghai Synchrotron Radiation Facility. The detection system is a functional expanding of the original end station, making full use of its precision positioning stages. The simultaneous collection of XEOL and total electron yield spectra is realized using homemade software when the excitation energy is scanned. The setup is validated by the 2D near-edge x-ray absorption spectroscopy (NEXAFS) XEOL mapping across the O K-edge of a nanostructured ZnO sample. The ability to detect the signal of very weak light-emitting material is verified by using TiO2 nanopowder.