Ingo Sieber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ingo Sieber has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
Ulrich Gengenbach
18 shared publicationsMartin Ungerer
8 shared publications- Ulrich Gengenbach
Institute for Automation and Applied Informatics (IAI), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
6 shared publications Horst Eggert
Forschungszentrum Karlsruhe GmbH (Germany)
5 shared publicationsAchim Wenka
Institute for Micro Process Engineering, KIT
4 shared publicationsChristian Pylatiuk
4 shared publications
Latest Publications
- 1 September 2026
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 74 (9) , 731-740
In-Process-Messmethode zur Bestimmung der Tröpfchengrößenverteilung für das Aerosol-on-Demand Jet-Drucksystem
Zusammenfassung: Auf dem Anwendungsfeld der gedruckten Elektronik hat sich der Aerosol-Jet Druck als Alternative zum Inkjet Druck auf Grund der Vorteile u.a. geringer Feature-Größen und der Möglichkeit, auf 3D geformten Oberflächen zu drucken, etabliert. Wir berichten über die Entwicklung eines patentierten Aerosol Jet-Druckkopfs. Zur Integration des Druckprozesses in einen digitalen Zwilling ist ein digitales Modell des Druckvorgangs notwendig. Die Modellierung des Aerosolsprays basiert unter anderem auf der Tröpfchengrößenverteilung. Desweiteren wird die Tröpfchengrößenverteilung auch zur Validierung des Fluid-Struktur-Wechselwirkung-Modells zur Simulation der Aerosolerzeugung benötigt. In diesem Artikel beschreiben wir die Messung der Tröpfchengrößenverteilung mit einem kommerziellen, auf dem Laserbeugungsverfahren beruhenden Messsystem und validieren damit ein einfaches Messverfahren auf Basis der Schattenwurftechnik, welches potenziell in der Lage ist, die Tröpfchengrößenverteilung auch in-line während des Druckprozesses zu bestimmen.
- 1 September 2026
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 74 (9) , 731-740
In-Process-Messmethode zur Bestimmung der Tröpfchengrößenverteilung für das Aerosol-on-Demand Jet-Drucksystem
Zusammenfassung: Auf dem Anwendungsfeld der gedruckten Elektronik hat sich der Aerosol-Jet Druck als Alternative zum Inkjet Druck auf Grund der Vorteile u.a. geringer Feature-Größen und der Möglichkeit, auf 3D geformten Oberflächen zu drucken, etabliert. Wir berichten über die Entwicklung eines patentierten Aerosol Jet-Druckkopfs. Zur Integration des Druckprozesses in einen digitalen Zwilling ist ein digitales Modell des Druckvorgangs notwendig. Die Modellierung des Aerosolsprays basiert unter anderem auf der Tröpfchengrößenverteilung. Desweiteren wird die Tröpfchengrößenverteilung auch zur Validierung des Fluid-Struktur-Wechselwirkung-Modells zur Simulation der Aerosolerzeugung benötigt. In diesem Artikel beschreiben wir die Messung der Tröpfchengrößenverteilung mit einem kommerziellen, auf dem Laserbeugungsverfahren beruhenden Messsystem und validieren damit ein einfaches Messverfahren auf Basis der Schattenwurftechnik, welches potenziell in der Lage ist, die Tröpfchengrößenverteilung auch in-line während des Druckprozesses zu bestimmen.
- Open Access
- 28 June 2026
- Published by Elsevier in Journal of Hazardous Materials Advances
- Vol. 23
Classification of microplastic particles in water using polarized light scattering and machine learning methods
- 28 June 2026
- Published by Elsevier in Journal of Hazardous Materials Advances
- Vol. 23
Open AccessClassification of microplastic particles in water using polarized light scattering and machine learning methods
- Open Access
- 6 February 2026
- Published by Elsevier in Journal of Aerosol Science
- Vol. 193
Particle image velocimetry for spray measurement of an Aerosol-on-Demand jet-printhead
- 6 February 2026
- Published by Elsevier in Journal of Aerosol Science
- Vol. 193
Open AccessParticle image velocimetry for spray measurement of an Aerosol-on-Demand jet-printhead
- Open Access
- 17 December 2025
- Published by Taylor & Francis in International Journal of Optomechatronics
- Vol. 20 (1)
Rapid deep-learning-based optical measurement of printed linear structures
- 17 December 2025
- Published by Taylor & Francis in International Journal of Optomechatronics
- Vol. 20 (1)
Open AccessRapid deep-learning-based optical measurement of printed linear structures
- 30 October 2025
- Published by Springer Nature
- p. 46-67
Usage of a Gaussian Process to Automatically Create a Reduced Model of the Particle Behavior in an Aerosol-on-Demand Printer
- 30 October 2025
- Published by Springer Nature
- p. 46-67
Usage of a Gaussian Process to Automatically Create a Reduced Model of the Particle Behavior in an Aerosol-on-Demand Printer
- Open Access
- 19 May 2025
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 10 (2) , 025007
Extrusion printing of radio frequency coplanar waveguides with commercial dispensing equipment
Coplanar waveguides (CPWs) are fundamental components of radio frequency and microwave circuits used for a variety of applications in telecommunications, radar systems and wireless communications. There is a need for low-cost and easily accessible manufacturing techniques that enable the fabrication of CPWs using commercial materials and equipment, thus reducing production costs and facilitating easy access to these versatile transmission lines. In this paper, we present CPWs on alumina substrates fabricated with an extrusion printing process based on low-cost commercial dispensing equipment and a commercial silver ink. For a 4 mm long CPW, we observe an insertion loss below 1 dB and a return loss better than 10 dB for the frequency range from 40 MHz to 33.8 GHz.
- 19 May 2025
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 10 (2) , 025007
Open AccessExtrusion printing of radio frequency coplanar waveguides with commercial dispensing equipment
Coplanar waveguides (CPWs) are fundamental components of radio frequency and microwave circuits used for a variety of applications in telecommunications, radar systems and wireless communications. There is a need for low-cost and easily accessible manufacturing techniques that enable the fabrication of CPWs using commercial materials and equipment, thus reducing production costs and facilitating easy access to these versatile transmission lines. In this paper, we present CPWs on alumina substrates fabricated with an extrusion printing process based on low-cost commercial dispensing equipment and a commercial silver ink. For a 4 mm long CPW, we observe an insertion loss below 1 dB and a return loss better than 10 dB for the frequency range from 40 MHz to 33.8 GHz.
- Open Access
- 1 January 2025
- Published by INSTICC
- p. 201-208
Digital Twin Concept for a Novel Aerosol-on-Demand Jet-Printing System
- 1 January 2025
- Published by INSTICC
- p. 201-208
Open AccessDigital Twin Concept for a Novel Aerosol-on-Demand Jet-Printing System
- 21 December 2024
- Published by Springer Nature
- p. 61-78
Tolerancing of the Atomiser Unit of an Aerosol-on-Demand Jet-Printhead
- 21 December 2024
- Published by Springer Nature
- p. 61-78
Tolerancing of the Atomiser Unit of an Aerosol-on-Demand Jet-Printhead
- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Design, Simulation, and Evaluation of a Low-Cost Photometer for Dissolved Ozone Measurement
The measurement of the dissolved ozone concentration is beneficial in various areas, where ozone is applied, such as medicine, disinfection, food processing, and wastewater treatment. Especially for medical ozone therapy, the measurement directly before and during the treatment is essential to avoid over- and under-dosing. For the wide range application of ozone measurement during medical therapy and in research, low-cost and reproducible measurement devices are indispensable. We present a low-cost photometer that measures the ozone concentration with UV photometry. It consists mainly of 3D-printed parts, while all other parts are commercially available. The root mean squared percentage error of the designed photometer is 14.68% and the root mean squared error is $\mathbf{1.04}\mathbf{mgl}^{-1}$ . We measured concentrations between $\mathbf{0\ mgl}^{-1}$ and $\mathbf{19}\mathbf{mgl}^{-1}$ , since higher concentrations cannot be produced with the ozone generator used. In principle, however, higher concentrations can also be measured with the photometer, such as the concentrations typical in ozone therapy of up to $\mathbf{30}\mathbf{mgl}^{-1}$ . We achieve good measurement results with the photometer in comparison with a commercial reference measuring instrument for dissolved ozone, although the reference instrument has a mean square error of 8.2%, but is more expensive by a factor of 17 than the photometer presented here. Low-cost instruments, such as the photometer, provide accurate and inexpensive measurements that are adaptable to a wide range of applications. For example, the photometer can be used in medicine for ozone therapy. The ozone concentration can be measured directly before the injection and thus before the treatment.- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Design, Simulation, and Evaluation of a Low-Cost Photometer for Dissolved Ozone Measurement
The measurement of the dissolved ozone concentration is beneficial in various areas, where ozone is applied, such as medicine, disinfection, food processing, and wastewater treatment. Especially for medical ozone therapy, the measurement directly before and during the treatment is essential to avoid over- and under-dosing. For the wide range application of ozone measurement during medical therapy and in research, low-cost and reproducible measurement devices are indispensable. We present a low-cost photometer that measures the ozone concentration with UV photometry. It consists mainly of 3D-printed parts, while all other parts are commercially available. The root mean squared percentage error of the designed photometer is 14.68% and the root mean squared error is $\mathbf{1.04}\mathbf{mgl}^{-1}$ . We measured concentrations between $\mathbf{0\ mgl}^{-1}$ and $\mathbf{19}\mathbf{mgl}^{-1}$ , since higher concentrations cannot be produced with the ozone generator used. In principle, however, higher concentrations can also be measured with the photometer, such as the concentrations typical in ozone therapy of up to $\mathbf{30}\mathbf{mgl}^{-1}$ . We achieve good measurement results with the photometer in comparison with a commercial reference measuring instrument for dissolved ozone, although the reference instrument has a mean square error of 8.2%, but is more expensive by a factor of 17 than the photometer presented here. Low-cost instruments, such as the photometer, provide accurate and inexpensive measurements that are adaptable to a wide range of applications. For example, the photometer can be used in medicine for ozone therapy. The ozone concentration can be measured directly before the injection and thus before the treatment.