Wilhelm von Rosenberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wilhelm von Rosenberg has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Danilo P. Mandic
Department of Electrical and Electronic Engineering, Imperial College London, United Kingdom
8 shared publications- Theerasak Chanwimalueang
Srinakharinwirot University,Faculty of Engineering,Dept. of Biomedical Engineering,Nakhon Nayok,Thailand
8 shared publications Valentin Goverdovsky
Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom
8 shared publications- Danilo P. Mandic
Imperial College London, London, United Kingdom
7 shared publications Tricia Adjei
Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom
5 shared publicationsUsman Jaffer
Imperial Vascular Unit, Imperial College Healthcare NHS Trust, London, United Kingdom
4 shared publications
Latest Publications
- 19 August 2019
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 9 (4) , 425-434
A physiology based model of heart rate variability
Heart rate variability (HRV) is governed by the autonomic nervous system (ANS) and is routinely used to estimate the state of body and mind. At the same time, recorded HRV features can vary substantially between people. A model for HRV that (1) correctly simulates observed HRV, (2) reliably functions for multiple scenarios, and (3) can be personalised using a manageable set of parameters, would be a significant step forward toward understanding individual responses to external influences, such as physical and physiological stress. Current HRV models attempt to reproduce HRV characteristics by mimicking the statistical properties of measured HRV signals. The model presented here for the simulation of HRV follows a radically different approach, as it is based on an approximation of the physiology behind the triggering of a heart beat and the biophysics mechanisms of how the triggering process—and thereby the HRV—is governed by the ANS. The model takes into account the metabolisation rates of neurotransmitters and the change in membrane potential depending on transmitter and ion concentrations. It produces an HRV time series that not only exhibits the features observed in real data, but also explains a reduction of low frequency band-power for physically or psychologically high intensity scenarios. Furthermore, the proposed model enables the personalisation of input parameters to the physiology of different people, a unique feature not present in existing methods. All these aspects are crucial for the understanding and application of future wearable health.
- 19 August 2019
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 9 (4) , 425-434
A physiology based model of heart rate variability
Heart rate variability (HRV) is governed by the autonomic nervous system (ANS) and is routinely used to estimate the state of body and mind. At the same time, recorded HRV features can vary substantially between people. A model for HRV that (1) correctly simulates observed HRV, (2) reliably functions for multiple scenarios, and (3) can be personalised using a manageable set of parameters, would be a significant step forward toward understanding individual responses to external influences, such as physical and physiological stress. Current HRV models attempt to reproduce HRV characteristics by mimicking the statistical properties of measured HRV signals. The model presented here for the simulation of HRV follows a radically different approach, as it is based on an approximation of the physiology behind the triggering of a heart beat and the biophysics mechanisms of how the triggering process—and thereby the HRV—is governed by the ANS. The model takes into account the metabolisation rates of neurotransmitters and the change in membrane potential depending on transmitter and ion concentrations. It produces an HRV time series that not only exhibits the features observed in real data, but also explains a reduction of low frequency band-power for physically or psychologically high intensity scenarios. Furthermore, the proposed model enables the personalisation of input parameters to the physiology of different people, a unique feature not present in existing methods. All these aspects are crucial for the understanding and application of future wearable health.
- Open Access
- 7 August 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 922
Early Postnatal Heart Rate Variability in Healthy Newborn Infants
Background: Despite the increasing interest in fetal and neonatal heart rate variability (HRV) analysis and its potential use as a tool for early disease stratification, no studies have previously described the normal trends of HRV in healthy babies during the first hours of postnatal life. Methods: We prospectively recruited 150 healthy babies from the postnatal ward and continuously recorded their electrocardiogram during the first 24 h after birth. Babies were included if born in good condition and stayed with their mother. Babies requiring any medication or treatment were excluded. Five-minute segments of the electrocardiogram (non-overlapping time-windows) with more than 90% consecutive good quality beats were included in the calculation of hourly medians and interquartile ranges to describe HRV trends over the first 24 h. We used multilevel mixed effects regression with auto-regressive covariance structure for all repeated measures analysis and t-tests to compare group differences. Non-normally distributed variables were log-transformed. Results: Nine out of 16 HRV metrics (including heart rate) changed significantly over the 24 h [Heart rate p < 0.01; Standard deviation of the NN intervals p = 0.01; Standard deviation of the Poincaré plot lengthwise p < 0.01; Cardiac sympathetic index (CSI) p < 0.01; Normalized high frequency power p = 0.03; Normalized low frequency power p < 0.01; Total power p < 0.01; HRV index p = 0.01; Parseval index p = 0.03], adjusted for relevant clinical variables. We observed an increase in several HRV metrics during the first 6 h followed by a gradual normalization by approximately 12 h of age. Between 6 and 12 h of age, only heart rate and the normalized low frequency power changed significantly, while between 12 and 18 h no metric, other than heart rate, changed significantly. Analysis with multilevel mixed effects regression analysis (multivariable) revealed that gestational age, reduced fetal movements, cardiotocography and maternal chronic or pregnancy induced illness were significant predictors of several HRV metrics. Conclusion: Heart rate variability changes significantly during the first day of life, particularly during the first 6 h. The significant correlations between HRV and clinical risk variables support the hypothesis that HRV is a good indicator of overall wellbeing of a baby and is sensitive to detect birth-related stress and monitor its resolution over time.
- 7 August 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 922
Open AccessEarly Postnatal Heart Rate Variability in Healthy Newborn Infants
Background: Despite the increasing interest in fetal and neonatal heart rate variability (HRV) analysis and its potential use as a tool for early disease stratification, no studies have previously described the normal trends of HRV in healthy babies during the first hours of postnatal life. Methods: We prospectively recruited 150 healthy babies from the postnatal ward and continuously recorded their electrocardiogram during the first 24 h after birth. Babies were included if born in good condition and stayed with their mother. Babies requiring any medication or treatment were excluded. Five-minute segments of the electrocardiogram (non-overlapping time-windows) with more than 90% consecutive good quality beats were included in the calculation of hourly medians and interquartile ranges to describe HRV trends over the first 24 h. We used multilevel mixed effects regression with auto-regressive covariance structure for all repeated measures analysis and t-tests to compare group differences. Non-normally distributed variables were log-transformed. Results: Nine out of 16 HRV metrics (including heart rate) changed significantly over the 24 h [Heart rate p < 0.01; Standard deviation of the NN intervals p = 0.01; Standard deviation of the Poincaré plot lengthwise p < 0.01; Cardiac sympathetic index (CSI) p < 0.01; Normalized high frequency power p = 0.03; Normalized low frequency power p < 0.01; Total power p < 0.01; HRV index p = 0.01; Parseval index p = 0.03], adjusted for relevant clinical variables. We observed an increase in several HRV metrics during the first 6 h followed by a gradual normalization by approximately 12 h of age. Between 6 and 12 h of age, only heart rate and the normalized low frequency power changed significantly, while between 12 and 18 h no metric, other than heart rate, changed significantly. Analysis with multilevel mixed effects regression analysis (multivariable) revealed that gestational age, reduced fetal movements, cardiotocography and maternal chronic or pregnancy induced illness were significant predictors of several HRV metrics. Conclusion: Heart rate variability changes significantly during the first day of life, particularly during the first 6 h. The significant correlations between HRV and clinical risk variables support the hypothesis that HRV is a good indicator of overall wellbeing of a baby and is sensitive to detect birth-related stress and monitor its resolution over time.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 5777-5780
Hearables: Feasibility and Validation of In-Ear Electrocardiogram
Out-of-clinic, continuous monitoring of vital signs is envisaged to become the backbone of future e-health. The emerging wrist worn devices have already proven to be a success in the measurement of pulse, however, a susceptibility to artefacts and missing data caused by regular motion in everyday activities, and the inability to continuously acquire the electrocardiogram call into question the utility of this technology in future e-Health. With this in mind, the head, and in particular the ear canals, have been investigated as possible locations for wearable devices. The ears offer a stable position relative to the vital signs during everyday activities, such as sitting, walking, running and sleeping, as well as being a practical and widely accepted base for wearable accessories. This all suggests that the ear canals are a most natural location for physiological sensing in the community. This work addresses the feasibility of recording the ECG from the ear canals, from a one-fits-all, user-friendly device. For rigour and clarity, we quantitatively compare the timings of the identified P-, QRS-, and T-waves within Ear-ECG and standard arm-ECG. Finally, to depict a future e-Health scenario for the Ear-ECG technology, a case study with an abnormal heart condition, the ventricular bigeminy, is presented. A comprehensive study over ten subjects demonstrates conclusively the possibility of in-ear cardiac monitoring in normal daily life.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 5777-5780
Hearables: Feasibility and Validation of In-Ear Electrocardiogram
Out-of-clinic, continuous monitoring of vital signs is envisaged to become the backbone of future e-health. The emerging wrist worn devices have already proven to be a success in the measurement of pulse, however, a susceptibility to artefacts and missing data caused by regular motion in everyday activities, and the inability to continuously acquire the electrocardiogram call into question the utility of this technology in future e-Health. With this in mind, the head, and in particular the ear canals, have been investigated as possible locations for wearable devices. The ears offer a stable position relative to the vital signs during everyday activities, such as sitting, walking, running and sleeping, as well as being a practical and widely accepted base for wearable accessories. This all suggests that the ear canals are a most natural location for physiological sensing in the community. This work addresses the feasibility of recording the ECG from the ear canals, from a one-fits-all, user-friendly device. For rigour and clarity, we quantitatively compare the timings of the identified P-, QRS-, and T-waves within Ear-ECG and standard arm-ECG. Finally, to depict a future e-Health scenario for the Ear-ECG technology, a case study with an abnormal heart condition, the ventricular bigeminy, is presented. A comprehensive study over ten subjects demonstrates conclusively the possibility of in-ear cardiac monitoring in normal daily life.
- 1 May 2019
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 7 (3) , 382-386
A pilot study of preoperative heart rate variability predicting pain during local anesthetic varicose vein surgery
- 1 May 2019
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 7 (3) , 382-386
A pilot study of preoperative heart rate variability predicting pain during local anesthetic varicose vein surgery
- Open Access
- 30 April 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 505
The ClassA Framework: HRV Based Assessment of SNS and PNS Dynamics Without LF-HF Controversies
The powers of the low frequency (LF) and high frequency (HF) components of heart rate variability (HRV) have become the de facto standard metrics in the assessment of the stress response, and the related activities of the sympathetic nervous system (SNS) and the parasympathetic nervous system (PNS). However, the widely adopted physiological interpretations of the LF and HF components in SNS /PNS balance are now questioned, which puts under serious scrutiny stress assessments which employ the LF and HF components. To avoid these controversies, we here introduce the novel Classification Angle (ClassA) framework, which yields a family of metrics which quantify cardiac dynamics in three-dimensions. This is achieved using a finite-difference plot of HRV, which displays successive rates of change of HRV, and is demonstrated to provide sufficient degrees of freedom to determine cardiac deceleration and/or acceleration. The robustness and accuracy of the novel ClassA framework is verified using HRV signals from ten males, recorded during standardized stress tests, consisting of rest, mental arithmetic, meditation, exercise and further meditation. Comparative statistical testing demonstrates that unlike the existing LF-HF metrics, the ClassA metrics are capable of distinguishing both the physical and mental stress epochs from the epochs of no stress, with statistical significance (Bonferroni corrected p-value ≤ 0.025); HF was able to distinguish physical stress from no stress, but was not able to identify mental stress. The ClassA results also indicated that at moderate levels of stress, the extent of parasympathetic withdrawal was greater than the extent of sympathetic activation. Finally, the analyses and the experimental results provide conclusive evidence that the proposed nonlinear approach to quantify cardiac activity from HRV resolves three critical obstacles to current HRV stress assessments: (i) it is not based on controversial assumptions of balance between the LF and HF powers; (ii) its temporal resolution when estimating parasympathetic dominance is as little as 10 s of HRV data, while only 60 s to estimate sympathetic dominance; (iii) unlike LF and HF analyses, the ClassA framework does not require the prohibitive assumption of signal stationarity. The ClassA framework is unique in offering HRV based stress analysis in three-dimensions.
- 30 April 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 505
Open AccessThe ClassA Framework: HRV Based Assessment of SNS and PNS Dynamics Without LF-HF Controversies
The powers of the low frequency (LF) and high frequency (HF) components of heart rate variability (HRV) have become the de facto standard metrics in the assessment of the stress response, and the related activities of the sympathetic nervous system (SNS) and the parasympathetic nervous system (PNS). However, the widely adopted physiological interpretations of the LF and HF components in SNS /PNS balance are now questioned, which puts under serious scrutiny stress assessments which employ the LF and HF components. To avoid these controversies, we here introduce the novel Classification Angle (ClassA) framework, which yields a family of metrics which quantify cardiac dynamics in three-dimensions. This is achieved using a finite-difference plot of HRV, which displays successive rates of change of HRV, and is demonstrated to provide sufficient degrees of freedom to determine cardiac deceleration and/or acceleration. The robustness and accuracy of the novel ClassA framework is verified using HRV signals from ten males, recorded during standardized stress tests, consisting of rest, mental arithmetic, meditation, exercise and further meditation. Comparative statistical testing demonstrates that unlike the existing LF-HF metrics, the ClassA metrics are capable of distinguishing both the physical and mental stress epochs from the epochs of no stress, with statistical significance (Bonferroni corrected p-value ≤ 0.025); HF was able to distinguish physical stress from no stress, but was not able to identify mental stress. The ClassA results also indicated that at moderate levels of stress, the extent of parasympathetic withdrawal was greater than the extent of sympathetic activation. Finally, the analyses and the experimental results provide conclusive evidence that the proposed nonlinear approach to quantify cardiac activity from HRV resolves three critical obstacles to current HRV stress assessments: (i) it is not based on controversial assumptions of balance between the LF and HF powers; (ii) its temporal resolution when estimating parasympathetic dominance is as little as 10 s of HRV data, while only 60 s to estimate sympathetic dominance; (iii) unlike LF and HF analyses, the ClassA framework does not require the prohibitive assumption of signal stationarity. The ClassA framework is unique in offering HRV based stress analysis in three-dimensions.
- Open Access
- 9 October 2018
- Published by S. Karger AG in Neonatology
- Vol. 115 (1) , 59-67
Prognostic Accuracy of Heart Rate Variability Analysis in Neonatal Encephalopathy: A Systematic Review
Background: Heart rate variability analysis offers real-time quantification of autonomic disturbance after perinatal asphyxia, and may therefore aid in disease stratification and prognostication after neonatal encephalopathy (NE). Objective: To systematically review the existing literature on the accuracy of early heart rate variability (HRV) to predict brain injury and adverse neurodevelopmental outcomes after NE. Design/Methods: We systematically searched the literature published between May 1947 and May 2018. We included all prospective and retrospective studies reporting HRV metrics, within the first 7 days of life in babies with NE, and its association with adverse outcomes (defined as evidence of brain injury on magnetic resonance imaging and/or abnormal neurodevelopment at ≥1 year of age). We extracted raw data wherever possible to calculate the prognostic indices with confidence intervals. Results: We retrieved 379 citations, 5 of which met the criteria. One further study was excluded as it analysed an already-included cohort. The 4 studies provided data on 205 babies, 80 (39%) of whom had adverse outcomes. Prognostic accuracy was reported for 12 different HRV metrics and the area under the curve (AUC) varied between 0.79 and 0.94. The best performing metric reported in the included studies was the relative power of high-frequency band, with an AUC of 0.94. Conclusions: HRV metrics are a promising bedside tool for early prediction of brain injury and neurodevelopmental outcome in babies with NE. Due to the small number of studies available, their heterogeneity and methodological limitations, further research is needed to refine this tool so that it can be used in clinical practice.
- 9 October 2018
- Published by S. Karger AG in Neonatology
- Vol. 115 (1) , 59-67
Open AccessPrognostic Accuracy of Heart Rate Variability Analysis in Neonatal Encephalopathy: A Systematic Review
Background: Heart rate variability analysis offers real-time quantification of autonomic disturbance after perinatal asphyxia, and may therefore aid in disease stratification and prognostication after neonatal encephalopathy (NE). Objective: To systematically review the existing literature on the accuracy of early heart rate variability (HRV) to predict brain injury and adverse neurodevelopmental outcomes after NE. Design/Methods: We systematically searched the literature published between May 1947 and May 2018. We included all prospective and retrospective studies reporting HRV metrics, within the first 7 days of life in babies with NE, and its association with adverse outcomes (defined as evidence of brain injury on magnetic resonance imaging and/or abnormal neurodevelopment at ≥1 year of age). We extracted raw data wherever possible to calculate the prognostic indices with confidence intervals. Results: We retrieved 379 citations, 5 of which met the criteria. One further study was excluded as it analysed an already-included cohort. The 4 studies provided data on 205 babies, 80 (39%) of whom had adverse outcomes. Prognostic accuracy was reported for 12 different HRV metrics and the area under the curve (AUC) varied between 0.79 and 0.94. The best performing metric reported in the included studies was the relative power of high-frequency band, with an AUC of 0.94. Conclusions: HRV metrics are a promising bedside tool for early prediction of brain injury and neurodevelopmental outcome in babies with NE. Due to the small number of studies available, their heterogeneity and methodological limitations, further research is needed to refine this tool so that it can be used in clinical practice.
- 26 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Magazine
- Vol. 35 (3) , 110-130
Bringing Wearable Sensors into the Classroom: A Participatory Approach [SP Education]
By bringing research into the curriculum, this article explores new opportunities to refresh some classic signal processing courses. Since 2015, we in the Electrical and Electronic Engineering (EEE) Department of Imperial College London, United Kingdom, have explored the extent to which the level of student engagement and learning can be enhanced by inviting the students to perform signal processing exercises on their own physiological data. More specifically, using new wearable sensor technology and video instructions as an experiment guide, the students are asked to record their electrocardiograms (ECGs) and perform both time- and spectral-domain estimation tasks on their own real-world data. In this way, the students not only gain experience with recording hardware and sources of signal contamination (baseline wanders and artifacts), but they also are highly motivated by being kept in the loop and through their part ownership of their course.
- 26 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Magazine
- Vol. 35 (3) , 110-130
Bringing Wearable Sensors into the Classroom: A Participatory Approach [SP Education]
By bringing research into the curriculum, this article explores new opportunities to refresh some classic signal processing courses. Since 2015, we in the Electrical and Electronic Engineering (EEE) Department of Imperial College London, United Kingdom, have explored the extent to which the level of student engagement and learning can be enhanced by inviting the students to perform signal processing exercises on their own physiological data. More specifically, using new wearable sensor technology and video instructions as an experiment guide, the students are asked to record their electrocardiograms (ECGs) and perform both time- and spectral-domain estimation tasks on their own real-world data. In this way, the students not only gain experience with recording hardware and sources of signal contamination (baseline wanders and artifacts), but they also are highly motivated by being kept in the loop and through their part ownership of their course.
- Open Access
- 19 April 2018
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 12 (1) , 1-10
Self-assessment of surgical ward crisis management using video replay augmented with stress biofeedback
We aimed to explore the feasibility and attitudes towards using video replay augmented with real time stress quantification for the self-assessment of clinical skills during simulated surgical ward crisis management. Twenty two clinicians participated in 3 different simulated ward based scenarios of deteriorating post-operative patients. Continuous ECG recordings were made for all participants to monitor stress levels using heart rate variability (HRV) indices. Video recordings of simulated scenarios augmented with real time stress biofeedback were replayed to participants. They were then asked to self-assess their performance using an objective assessment tool. Participants attitudes were explored using a post study questionnaire. Using HRV stress indices, we demonstrated higher stress levels in novice participants. Self-assessment scores were significantly higher in more experienced participants. Overall, participants felt that video replay and augmented stress biofeedback were useful in self-assessment. Self-assessment using an objective self-assessment tool alongside video replay augmented with stress biofeedback is feasible in a simulated setting and well liked by participants.
- 19 April 2018
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 12 (1) , 1-10
Open AccessSelf-assessment of surgical ward crisis management using video replay augmented with stress biofeedback
We aimed to explore the feasibility and attitudes towards using video replay augmented with real time stress quantification for the self-assessment of clinical skills during simulated surgical ward crisis management. Twenty two clinicians participated in 3 different simulated ward based scenarios of deteriorating post-operative patients. Continuous ECG recordings were made for all participants to monitor stress levels using heart rate variability (HRV) indices. Video recordings of simulated scenarios augmented with real time stress biofeedback were replayed to participants. They were then asked to self-assess their performance using an objective assessment tool. Participants attitudes were explored using a post study questionnaire. Using HRV stress indices, we demonstrated higher stress levels in novice participants. Self-assessment scores were significantly higher in more experienced participants. Overall, participants felt that video replay and augmented stress biofeedback were useful in self-assessment. Self-assessment using an objective self-assessment tool alongside video replay augmented with stress biofeedback is feasible in a simulated setting and well liked by participants.
- Open Access
- 15 November 2017
- Published by The Royal Society in Royal Society Open Science
- Vol. 4 (11) , 171214
Hearables: feasibility of recording cardiac rhythms from head and in-ear locations
Mobile technologies for the recording of vital signs and neural signals are envisaged to underpin the operation of future health services. For practical purposes, unobtrusive devices are favoured, such as those embedded in a helmet or incorporated onto an earplug. However, these locations have so far been underexplored, as the comparably narrow neck impedes the propagation of vital signals from the torso to the head surface. To establish the principles behind electrocardiogram (ECG) recordings from head and ear locations, we first introduce a realistic three-dimensional biophysics model for the propagation of cardiac electric potentials to the head surface, which demonstrates the feasibility of head-ECG recordings. Next, the proposed biophysics propagation model is verified over comprehensive real-world experiments based on head- and in-ear-ECG measurements. It is shown both that the proposed model is an excellent match for the recordings, and that the quality of head- and ear-ECG is sufficient for a reliable identification of the timing and shape of the characteristic P-, Q-, R-, S- and T-waves within the cardiac cycle. This opens up a range of new possibilities in the identification and management of heart conditions, such as myocardial infarction and atrial fibrillation, based on 24/7 continuous in-ear measurements. The study therefore paves the way for the incorporation of the cardiac modality into future ‘hearables’, unobtrusive devices for health monitoring.
- 15 November 2017
- Published by The Royal Society in Royal Society Open Science
- Vol. 4 (11) , 171214
Open AccessHearables: feasibility of recording cardiac rhythms from head and in-ear locations
Mobile technologies for the recording of vital signs and neural signals are envisaged to underpin the operation of future health services. For practical purposes, unobtrusive devices are favoured, such as those embedded in a helmet or incorporated onto an earplug. However, these locations have so far been underexplored, as the comparably narrow neck impedes the propagation of vital signals from the torso to the head surface. To establish the principles behind electrocardiogram (ECG) recordings from head and ear locations, we first introduce a realistic three-dimensional biophysics model for the propagation of cardiac electric potentials to the head surface, which demonstrates the feasibility of head-ECG recordings. Next, the proposed biophysics propagation model is verified over comprehensive real-world experiments based on head- and in-ear-ECG measurements. It is shown both that the proposed model is an excellent match for the recordings, and that the quality of head- and ear-ECG is sufficient for a reliable identification of the timing and shape of the characteristic P-, Q-, R-, S- and T-waves within the cardiac cycle. This opens up a range of new possibilities in the identification and management of heart conditions, such as myocardial infarction and atrial fibrillation, based on 24/7 continuous in-ear measurements. The study therefore paves the way for the incorporation of the cardiac modality into future ‘hearables’, unobtrusive devices for health monitoring.
- Open Access
- 8 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 5, 1-10
Pain Prediction From ECG in Vascular Surgery
Varicose vein surgeries are routine outpatient procedures, which are often performed under local anaesthesia. The use of local anaesthesia both minimises the risk to patients and is cost effective, however, a number of patients still experience pain during surgery. Surgical teams must therefore decide to administer either a general or local anaesthetic based on their subjective qualitative assessment of patient anxiety and sensitivity to pain, without any means to objectively validate their decision. To this end, we develop a 3-D polynomial surface fit, of physiological metrics and numerical pain ratings from patients, in order to model the link between the modulation of cardiovascular responses and pain in varicose vein surgeries. Spectral and structural complexity features found in heart rate variability signals, recorded immediately prior to 17 varicose vein surgeries, are used as pain metrics. The so obtained pain prediction model is validated through a leave-one-out validation, and achieved a Kappa coefficient of 0.72 (substantial agreement) and an area below a receiver operating characteristic curve of 0.97 (almost perfect accuracy). This proof-of-concept study conclusively demonstrates the feasibility of the accurate classification of pain sensitivity, and introduces a mathematical model to aid clinicians in the objective administration of the safest and most cost-effective anaesthetic to individual patients.
- 8 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 5, 1-10
Open AccessPain Prediction From ECG in Vascular Surgery
Varicose vein surgeries are routine outpatient procedures, which are often performed under local anaesthesia. The use of local anaesthesia both minimises the risk to patients and is cost effective, however, a number of patients still experience pain during surgery. Surgical teams must therefore decide to administer either a general or local anaesthetic based on their subjective qualitative assessment of patient anxiety and sensitivity to pain, without any means to objectively validate their decision. To this end, we develop a 3-D polynomial surface fit, of physiological metrics and numerical pain ratings from patients, in order to model the link between the modulation of cardiovascular responses and pain in varicose vein surgeries. Spectral and structural complexity features found in heart rate variability signals, recorded immediately prior to 17 varicose vein surgeries, are used as pain metrics. The so obtained pain prediction model is validated through a leave-one-out validation, and achieved a Kappa coefficient of 0.72 (substantial agreement) and an area below a receiver operating characteristic curve of 0.97 (almost perfect accuracy). This proof-of-concept study conclusively demonstrates the feasibility of the accurate classification of pain sensitivity, and introduces a mathematical model to aid clinicians in the objective administration of the safest and most cost-effective anaesthetic to individual patients.