Kevin Little
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kevin Little has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Szynkman
Physique des Particules Université de Montréal 6128, succ. centre-ville H3C 3J7 Montréal C.P QC Canada
3 shared publications - David London
Université de Montréal
3 shared publications - Ken Kiers
Physics and Engineering Department Taylor University 236 West Reade Ave. 46989 Upland IN USA
3 shared publications - Makiko Nagashima
Physique des Particules Université de Montréal 6128, succ. centre-ville H3C 3J7 Montréal C.P QC Canada
3 shared publications - Emily L. Marshall
Department of Radiology University of Florida Gainesville, FL USA
2 shared publications Ingrid Reiser
The University of Chicago Chicago Illinois USA
2 shared publications
Latest Publications
- Open Access
- 19 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70511
Design and implementation of an AAPM volunteer database for advancing global medical physics initiatives
Purpose: The purpose of this study is to assess American Association of Physicists in Medicine (AAPM) members' availability to volunteer, share their expertise, and promote global collaboration in medical physics by partnering with international colleagues who seek support in strengthening their medical physics practice. Methods: The questionnaire was administered to AAPM members to assess their willingness to volunteer, preferred engagement modalities, and availability for different types of volunteer activities. The questionnaire was integrated into the AAPM member profile and covered therapy, diagnostic, and nuclear medicine disciplines, capturing participants' visiting preferences and expertise in teaching and training. Respondents were categorized based on demographic factors such as years of experience, expertise areas, and geographic location. Results: A total of 409 AAPM members completed and submitted 427 responses to the questionnaire (18 members submitted two discipline‐specific sets). The 4% response rate confines this report to exploratory findings rather than predictive conclusions for all AAPM members. Most respondents expressed a preference for short‐term engagements, with 49.2% favoring visits of less than one week. Volunteers reported significant expertise, with a substantial portion having more than 15 years of professional experience. Additionally, respondents demonstrated active participation in international activities, with 57 engaged in AAPM initiatives and over 100 involved in private nonprofit or nongovernmental organizations (NGOs). Conclusions: This report highlights the breadth of expertise and willingness of AAPM members to collaborate and support education across all specialties, contributing to the advancement of global medical physics. While the volunteer data shows significant experience and expertise, targeted recruitment is needed in certain specialized areas. This initiative offers a scalable and sustainable model for global volunteerism in medical physics, complementing traditional in person training and addressing the needs of low‐ and middle‐income countries (LMICs).
- 19 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70511
Open AccessDesign and implementation of an AAPM volunteer database for advancing global medical physics initiatives
Purpose: The purpose of this study is to assess American Association of Physicists in Medicine (AAPM) members' availability to volunteer, share their expertise, and promote global collaboration in medical physics by partnering with international colleagues who seek support in strengthening their medical physics practice. Methods: The questionnaire was administered to AAPM members to assess their willingness to volunteer, preferred engagement modalities, and availability for different types of volunteer activities. The questionnaire was integrated into the AAPM member profile and covered therapy, diagnostic, and nuclear medicine disciplines, capturing participants' visiting preferences and expertise in teaching and training. Respondents were categorized based on demographic factors such as years of experience, expertise areas, and geographic location. Results: A total of 409 AAPM members completed and submitted 427 responses to the questionnaire (18 members submitted two discipline‐specific sets). The 4% response rate confines this report to exploratory findings rather than predictive conclusions for all AAPM members. Most respondents expressed a preference for short‐term engagements, with 49.2% favoring visits of less than one week. Volunteers reported significant expertise, with a substantial portion having more than 15 years of professional experience. Additionally, respondents demonstrated active participation in international activities, with 57 engaged in AAPM initiatives and over 100 involved in private nonprofit or nongovernmental organizations (NGOs). Conclusions: This report highlights the breadth of expertise and willingness of AAPM members to collaborate and support education across all specialties, contributing to the advancement of global medical physics. While the volunteer data shows significant experience and expertise, targeted recruitment is needed in certain specialized areas. This initiative offers a scalable and sustainable model for global volunteerism in medical physics, complementing traditional in person training and addressing the needs of low‐ and middle‐income countries (LMICs).
- Open Access
- 24 March 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (5) , e70084
Shielding resources for four common radiopharmaceuticals utilized for imaging and therapy: Tc‐99m, F‐18, I‐131, and Lu‐177
Introduction: The use of radioactive materials in the United States has been tightly regulated by the Nuclear Regulatory Commission and other entities for many decades. In 2015, however, the Joint Commission began to require hospital‐based nuclear medicine departments to conduct shielding designs and evaluations for radioactive material areas, mirroring established x‐ray practices. NCRP Report No. 147 guides diagnostic medical x‐ray shielding, but obviously cannot be used alone for nuclear medicine applications. The rising demand for theranostic nuclear medicine shielding evaluations particularly necessitates updated focused guidance, the aim of this report.Methods: Monte Carlo simulations were conducted using GATE software to analyze the effects of various barriers on the transmission of radioactive emissions. The simulations used point sources of Tc‐99m, F‐18, I‐131, and Lu‐177 and evaluated dose deposition to blocks of tissue using Dose Actors. Different ceiling heights (ranging from 10–16 feet) were also tested for scattering effects. The Archer equation was employed to fit transmission curves and estimate required barrier thicknesses.Results: Broad beam transmission factors and Archer fitting parameters are reported for various materials including lead, gypsum, concrete (light weight and normal weight), glass, and steel. A sample shielding calculation is provided for a wall separating Lu‐177 dotatate patients from an adjacent office to maintain public dose limits. Relevant occupancy factors are also provided.Conclusions: While Lu‐177 has a relatively low exposure rate constant, shielding may be necessary for high‐volume therapies like Lu‐177 DOTATATE and Lu‐177 vipivotide tetraxetan PSMA. Shielding involves accounting for broad radiation beams and requires thorough characterization of radiation buildup. When shielding to the typical height of 7 feet, scatter from ceilings and floors is negligible for transmission above 10%, but severely limits the ability to shield for transmission below 1%.
- 24 March 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (5) , e70084
Open AccessShielding resources for four common radiopharmaceuticals utilized for imaging and therapy: Tc‐99m, F‐18, I‐131, and Lu‐177
Introduction: The use of radioactive materials in the United States has been tightly regulated by the Nuclear Regulatory Commission and other entities for many decades. In 2015, however, the Joint Commission began to require hospital‐based nuclear medicine departments to conduct shielding designs and evaluations for radioactive material areas, mirroring established x‐ray practices. NCRP Report No. 147 guides diagnostic medical x‐ray shielding, but obviously cannot be used alone for nuclear medicine applications. The rising demand for theranostic nuclear medicine shielding evaluations particularly necessitates updated focused guidance, the aim of this report.Methods: Monte Carlo simulations were conducted using GATE software to analyze the effects of various barriers on the transmission of radioactive emissions. The simulations used point sources of Tc‐99m, F‐18, I‐131, and Lu‐177 and evaluated dose deposition to blocks of tissue using Dose Actors. Different ceiling heights (ranging from 10–16 feet) were also tested for scattering effects. The Archer equation was employed to fit transmission curves and estimate required barrier thicknesses.Results: Broad beam transmission factors and Archer fitting parameters are reported for various materials including lead, gypsum, concrete (light weight and normal weight), glass, and steel. A sample shielding calculation is provided for a wall separating Lu‐177 dotatate patients from an adjacent office to maintain public dose limits. Relevant occupancy factors are also provided.Conclusions: While Lu‐177 has a relatively low exposure rate constant, shielding may be necessary for high‐volume therapies like Lu‐177 DOTATATE and Lu‐177 vipivotide tetraxetan PSMA. Shielding involves accounting for broad radiation beams and requires thorough characterization of radiation buildup. When shielding to the typical height of 7 feet, scatter from ceilings and floors is negligible for transmission above 10%, but severely limits the ability to shield for transmission below 1%.
- 1 August 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (11) , 1970-1976.e1
Segmental Yttrium-90 Radioembolization Using Glass Microspheres Greater than 400 Gray for the Treatment of Intrahepatic Cholangiocarcinoma: A Preliminary Experience
- 1 August 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (11) , 1970-1976.e1
Segmental Yttrium-90 Radioembolization Using Glass Microspheres Greater than 400 Gray for the Treatment of Intrahepatic Cholangiocarcinoma: A Preliminary Experience
- Open Access
- 30 March 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (5)
AAPM task group report 305: Guidance for standardization of vendor‐neutral reject analysis in radiography
Reject rate analysis is considered an integral part of a diagnostic radiography quality control (QC) program. A rejected image is a patient radiograph that was not presented to a radiologist for diagnosis and that contributes unnecessary radiation dose to the patient. Reject rates that are either too high or too low may suggest systemic department shortcomings in QC mechanisms. Due to the lack of standardization, reject data often cannot be easily compared between radiography systems from different vendors. The purpose of this report is to provide guidance to help standardize data elements that are required for comprehensive reject analysis and to propose data reporting and workflows to enable an effective and comprehensive reject rate monitoring program. Essential data elements, a proposed schema for classifying reject reasons, and workflow implementation options are recommended in this task group report.
- 30 March 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (5)
Open AccessAAPM task group report 305: Guidance for standardization of vendor‐neutral reject analysis in radiography
Reject rate analysis is considered an integral part of a diagnostic radiography quality control (QC) program. A rejected image is a patient radiograph that was not presented to a radiologist for diagnosis and that contributes unnecessary radiation dose to the patient. Reject rates that are either too high or too low may suggest systemic department shortcomings in QC mechanisms. Due to the lack of standardization, reject data often cannot be easily compared between radiography systems from different vendors. The purpose of this report is to provide guidance to help standardize data elements that are required for comprehensive reject analysis and to propose data reporting and workflows to enable an effective and comprehensive reject rate monitoring program. Essential data elements, a proposed schema for classifying reject reasons, and workflow implementation options are recommended in this task group report.
- Open Access
- 15 October 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (10) , e0240184
Are quantitative features of lung nodules reproducible at different CT acquisition and reconstruction parameters?
Consistency and duplicability in Computed Tomography (CT) output is essential to quantitative imaging for lung cancer detection and monitoring. This study of CT-detected lung nodules investigated the reproducibility of volume-, density-, and texture-based features (outcome variables) over routine ranges of radiation dose, reconstruction kernel, and slice thickness. CT raw data of 23 nodules were reconstructed using 320 acquisition/reconstruction conditions (combinations of 4 doses, 10 kernels, and 8 thicknesses). Scans at 12.5%, 25%, and 50% of protocol dose were simulated; reduced-dose and full-dose data were reconstructed using conventional filtered back-projection and iterative-reconstruction kernels at a range of thicknesses (0.6–5.0 mm). Full-dose/B50f kernel reconstructions underwent expert segmentation for reference Region-Of-Interest (ROI) and nodule volume per thickness; each ROI was applied to 40 corresponding images (combinations of 4 doses and 10 kernels). Typical texture analysis metrics (including 5 histogram features, 13 Gray Level Co-occurrence Matrix, 5 Run Length Matrix, 2 Neighboring Gray-Level Dependence Matrix, and 3 Neighborhood Gray-Tone Difference Matrix) were computed per ROI. Reconstruction conditions resulting in no significant change in volume, density, or texture metrics were identified as “compatible pairs” for a given outcome variable. Our results indicate that as thickness increases, volumetric reproducibility decreases, while reproducibility of histogram- and texture-based features across different acquisition and reconstruction parameters improves. To achieve concomitant reproducibility of volumetric and radiomic results across studies, balanced standardization of the imaging acquisition parameters is required.
- 15 October 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (10) , e0240184
Open AccessAre quantitative features of lung nodules reproducible at different CT acquisition and reconstruction parameters?
Consistency and duplicability in Computed Tomography (CT) output is essential to quantitative imaging for lung cancer detection and monitoring. This study of CT-detected lung nodules investigated the reproducibility of volume-, density-, and texture-based features (outcome variables) over routine ranges of radiation dose, reconstruction kernel, and slice thickness. CT raw data of 23 nodules were reconstructed using 320 acquisition/reconstruction conditions (combinations of 4 doses, 10 kernels, and 8 thicknesses). Scans at 12.5%, 25%, and 50% of protocol dose were simulated; reduced-dose and full-dose data were reconstructed using conventional filtered back-projection and iterative-reconstruction kernels at a range of thicknesses (0.6–5.0 mm). Full-dose/B50f kernel reconstructions underwent expert segmentation for reference Region-Of-Interest (ROI) and nodule volume per thickness; each ROI was applied to 40 corresponding images (combinations of 4 doses and 10 kernels). Typical texture analysis metrics (including 5 histogram features, 13 Gray Level Co-occurrence Matrix, 5 Run Length Matrix, 2 Neighboring Gray-Level Dependence Matrix, and 3 Neighborhood Gray-Tone Difference Matrix) were computed per ROI. Reconstruction conditions resulting in no significant change in volume, density, or texture metrics were identified as “compatible pairs” for a given outcome variable. Our results indicate that as thickness increases, volumetric reproducibility decreases, while reproducibility of histogram- and texture-based features across different acquisition and reconstruction parameters improves. To achieve concomitant reproducibility of volumetric and radiomic results across studies, balanced standardization of the imaging acquisition parameters is required.
- 1 February 2017
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 14 (2) , 208-216
Unified Database for Rejected Image Analysis Across Multiple Vendors in Radiography
- 1 February 2017
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 14 (2) , 208-216
Unified Database for Rejected Image Analysis Across Multiple Vendors in Radiography
- 24 February 2015
- Published by Wiley in Medical Physics
- Vol. 42 (3) , 1307-1320
Sinogram restoration in computed tomography with an edge‐preserving penalty
Purpose: With the goal of producing a less computationally intensive alternative to fully iterative penalized‐likelihood image reconstruction, our group has explored the use of penalized‐likelihood sinogram restoration for transmission tomography. Previously, we have exclusively used a quadratic penalty in our restoration objective function. However, a quadratic penalty does not excel at preserving edges while reducing noise. Here, we derive a restoration update equation for nonquadratic penalties. Additionally, we perform a feasibility study to extend our sinogram restoration method to a helical cone‐beam geometry and clinical data.Methods: A restoration update equation for nonquadratic penalties is derived using separable parabolic surrogates (SPS). A method for calculating sinogram degradation coefficients for a helical cone‐beam geometry is proposed. Using simulated data, sinogram restorations are performed using both a quadratic penalty and the edge‐preserving Huber penalty. After sinogram restoration, Fourier‐based analytical methods are used to obtain reconstructions, and resolution‐noise trade‐offs are investigated. For the fan‐beam geometry, a comparison is made to image‐domain SPS reconstruction using the Huber penalty. The effects of varying object size and contrast are also investigated. For the helical cone‐beam geometry, we investigate the effect of helical pitch (axial movement/rotation). Huber‐penalty sinogram restoration is performed on 3D clinical data, and the reconstructed images are compared to those generated with no restoration.Results: We find that by applying the edge‐preserving Huber penalty to our sinogram restoration methods, the reconstructed image has a better resolution‐noise relationship than an image produced using a quadratic penalty in the sinogram restoration. However, we find that this relatively straightforward approach to edge preservation in the sinogram domain is affected by the physical size of imaged objects in addition to the contrast across the edge. This presents some disadvantages of this method relative to image‐domain edge‐preserving methods, although the computational burden of the sinogram‐domain approach is much lower. For a helical cone‐beam geometry, we found applying sinogram restoration in 3D was reasonable and that pitch did not make a significant difference in the general effect of sinogram restoration. The application of Huber‐penalty sinogram restoration to clinical data resulted in a reconstruction with less noise while retaining resolution.Conclusions: Sinogram restoration with the Huber penalty is able to provide better resolution‐noise performance than restoration with a quadratic penalty. Additionally, sinogram restoration with the Huber penalty is feasible for helical cone‐beam CT and can be applied to clinical data.
- 24 February 2015
- Published by Wiley in Medical Physics
- Vol. 42 (3) , 1307-1320
Sinogram restoration in computed tomography with an edge‐preserving penalty
Purpose: With the goal of producing a less computationally intensive alternative to fully iterative penalized‐likelihood image reconstruction, our group has explored the use of penalized‐likelihood sinogram restoration for transmission tomography. Previously, we have exclusively used a quadratic penalty in our restoration objective function. However, a quadratic penalty does not excel at preserving edges while reducing noise. Here, we derive a restoration update equation for nonquadratic penalties. Additionally, we perform a feasibility study to extend our sinogram restoration method to a helical cone‐beam geometry and clinical data.Methods: A restoration update equation for nonquadratic penalties is derived using separable parabolic surrogates (SPS). A method for calculating sinogram degradation coefficients for a helical cone‐beam geometry is proposed. Using simulated data, sinogram restorations are performed using both a quadratic penalty and the edge‐preserving Huber penalty. After sinogram restoration, Fourier‐based analytical methods are used to obtain reconstructions, and resolution‐noise trade‐offs are investigated. For the fan‐beam geometry, a comparison is made to image‐domain SPS reconstruction using the Huber penalty. The effects of varying object size and contrast are also investigated. For the helical cone‐beam geometry, we investigate the effect of helical pitch (axial movement/rotation). Huber‐penalty sinogram restoration is performed on 3D clinical data, and the reconstructed images are compared to those generated with no restoration.Results: We find that by applying the edge‐preserving Huber penalty to our sinogram restoration methods, the reconstructed image has a better resolution‐noise relationship than an image produced using a quadratic penalty in the sinogram restoration. However, we find that this relatively straightforward approach to edge preservation in the sinogram domain is affected by the physical size of imaged objects in addition to the contrast across the edge. This presents some disadvantages of this method relative to image‐domain edge‐preserving methods, although the computational burden of the sinogram‐domain approach is much lower. For a helical cone‐beam geometry, we found applying sinogram restoration in 3D was reasonable and that pitch did not make a significant difference in the general effect of sinogram restoration. The application of Huber‐penalty sinogram restoration to clinical data resulted in a reconstruction with less noise while retaining resolution.Conclusions: Sinogram restoration with the Huber penalty is able to provide better resolution‐noise performance than restoration with a quadratic penalty. Additionally, sinogram restoration with the Huber penalty is feasible for helical cone‐beam CT and can be applied to clinical data.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 2174-2177
An algorithm for modeling non-linear system effects in iterative CT reconstruction
With continued development and clinical deployment of iterative algorithms for CT, there remain many open questions about the best way to model various physical effects that degrade CT images, including geometric effects (finite sized detectors and sources), spectral effects due to the use of polychromatic spectra, scattered radiation, and noise. In this paper, we focus on the question of geometric modeling. Some recent investigations have concluded that geometric modeling may be unnecessary, with simple point source and point detector models yielding good results as measured near the isocenter of images. We further investigate this question in the present work, paying particular attention to peripheral image quality, where we find the effects of modeling to be more significant than at the isocenter. We also seek to evaluate the question of whether nonlinear modeling, which more closely captures the way CT data are acquired, offers any advantage over the traditional linear modeling used in iterative CT algorithms. In order to more accurately model the averaging in the transmitted intensity domain, we derive an update equation using separable paraboloidal surrogates (SPS) that is able to model a finite source, finite detectors, and data acquired over a small angular trajectory. We model these effects by incorporating many "beamlets" into the imaging model. In this work, we compare reconstructions made with additional modeling and without modeling in an SPS algorithm. We find that while modeling geometry makes a significant impact on the reconstructed image, a non-linear model may not be worth the additional computational cost.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 2174-2177
An algorithm for modeling non-linear system effects in iterative CT reconstruction
With continued development and clinical deployment of iterative algorithms for CT, there remain many open questions about the best way to model various physical effects that degrade CT images, including geometric effects (finite sized detectors and sources), spectral effects due to the use of polychromatic spectra, scattered radiation, and noise. In this paper, we focus on the question of geometric modeling. Some recent investigations have concluded that geometric modeling may be unnecessary, with simple point source and point detector models yielding good results as measured near the isocenter of images. We further investigate this question in the present work, paying particular attention to peripheral image quality, where we find the effects of modeling to be more significant than at the isocenter. We also seek to evaluate the question of whether nonlinear modeling, which more closely captures the way CT data are acquired, offers any advantage over the traditional linear modeling used in iterative CT algorithms. In order to more accurately model the averaging in the transmitted intensity domain, we derive an update equation using separable paraboloidal surrogates (SPS) that is able to model a finite source, finite detectors, and data acquired over a small angular trajectory. We model these effects by incorporating many "beamlets" into the imaging model. In this work, we compare reconstructions made with additional modeling and without modeling in an SPS algorithm. We find that while modeling geometry makes a significant impact on the reconstructed image, a non-linear model may not be worth the additional computational cost.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 2534-2536
Sinogram restoration in computed tomography with a non-quadratic, edge-preserving penalty
With the goal of producing a less computationally intensive alternative to fully-iterative penalized-likelihood image reconstruction, our group has been exploring the use of penalized-likelihood sinogram restoration for transmission tomography. Sinogram restoration allows for the correction of anode angle effects, off-focal radiation, detector afterglow, crosstalk, beam hardening, and noise effects without the backprojections and reprojections used in fully-iterative reconstruction methods. After sinogram restoration, reconstruction is performed using traditional filtered backprojection methods. Previously, we have exclusively used a quadratic penalty in our restoration objective function. Here, we derive a restoration update equation using separable parabolic surrogates (SPS) for non-quadratic penalties. Using the edge-preserving Huber penalty in our sinogram restoration, we show improvements in resolution-variance tradeoffs compared to using a quadratic penalty in the sinogram restoration. However, this simple approach to edge preservation in the sinogram domain is affected by the physical size of the edge and not just the increase in contrast across the edge. This is a disadvantage relative to image-domain edge-preserving methods.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 2534-2536
Sinogram restoration in computed tomography with a non-quadratic, edge-preserving penalty
With the goal of producing a less computationally intensive alternative to fully-iterative penalized-likelihood image reconstruction, our group has been exploring the use of penalized-likelihood sinogram restoration for transmission tomography. Sinogram restoration allows for the correction of anode angle effects, off-focal radiation, detector afterglow, crosstalk, beam hardening, and noise effects without the backprojections and reprojections used in fully-iterative reconstruction methods. After sinogram restoration, reconstruction is performed using traditional filtered backprojection methods. Previously, we have exclusively used a quadratic penalty in our restoration objective function. Here, we derive a restoration update equation using separable parabolic surrogates (SPS) for non-quadratic penalties. Using the edge-preserving Huber penalty in our sinogram restoration, we show improvements in resolution-variance tradeoffs compared to using a quadratic penalty in the sinogram restoration. However, this simple approach to edge preservation in the sinogram domain is affected by the physical size of the edge and not just the increase in contrast across the edge. This is a disadvantage relative to image-domain edge-preserving methods.
- 4 March 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7627, 762716
Toward validation of a 3D structured background model for breast imaging
Breast tomosynthesis is a novel modality for breast imaging that aims to provide partial depth resolution of the tissue structure. In order to optimize tomosynthesis acquisition and reconstruction parameters, it is necessary to model the structured breast background. The purpose of this work was to investigate whether filtered noise could be used as a structure surrogate. Human performance in a SKE detection task was determined through 2-AFC experiments using tomosynthesis backgrounds extracted from 55 normal breasts. Mathematically defined lesions were projected and reconstructed using the same acquisition and reconstruction parameters as the clinical data. Signal diameters were 0.05, 0.2 and 0.8 cm. Performance in the center projection as well as a reconstructed slice through the signal center was determined. The gray-scale volume was binarized and attenuation coefficients of adipose or fibroglandular tissue were assigned to the voxels. This volume was then projected and reconstructed and performance of a pre-whitening observer was computed for the slice and center projections. Human performance in clinical backgrounds was predicted by a pre-whitening observer model, both in projection images and reconstructed slices. This indicates that pre-whitening observer performance is a good predictor of human performance and can be used to predict human performance in the simulated backgrounds. When comparing model observer performance in the two background types, comparable performance was found. This indicates that structured background based on filtered noise may be useful in tomosynthesis system optimization. In conclusion, for a SKE detection task, similar performance was reached in clinical and filtered noise backgrounds. This indicates that detection performance based on the filtered noise background model may be used to predict performance in actual breast backgrounds.
- 4 March 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7627, 762716
Toward validation of a 3D structured background model for breast imaging
Breast tomosynthesis is a novel modality for breast imaging that aims to provide partial depth resolution of the tissue structure. In order to optimize tomosynthesis acquisition and reconstruction parameters, it is necessary to model the structured breast background. The purpose of this work was to investigate whether filtered noise could be used as a structure surrogate. Human performance in a SKE detection task was determined through 2-AFC experiments using tomosynthesis backgrounds extracted from 55 normal breasts. Mathematically defined lesions were projected and reconstructed using the same acquisition and reconstruction parameters as the clinical data. Signal diameters were 0.05, 0.2 and 0.8 cm. Performance in the center projection as well as a reconstructed slice through the signal center was determined. The gray-scale volume was binarized and attenuation coefficients of adipose or fibroglandular tissue were assigned to the voxels. This volume was then projected and reconstructed and performance of a pre-whitening observer was computed for the slice and center projections. Human performance in clinical backgrounds was predicted by a pre-whitening observer model, both in projection images and reconstructed slices. This indicates that pre-whitening observer performance is a good predictor of human performance and can be used to predict human performance in the simulated backgrounds. When comparing model observer performance in the two background types, comparable performance was found. This indicates that structured background based on filtered noise may be useful in tomosynthesis system optimization. In conclusion, for a SKE detection task, similar performance was reached in clinical and filtered noise backgrounds. This indicates that detection performance based on the filtered noise background model may be used to predict performance in actual breast backgrounds.