Dion Khodagholy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dion Khodagholy has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Jennifer N. Gelinas
Pediatrics Division of Neurology, University of California Irvine, Irvine, CA, USA
26 shared publications Claudia Cea
Department of Electrical Engineering, Columbia University, New York, USA
14 shared publicationsZifang Zhao
Department of Electrical Engineering, Columbia University, New York, USA
10 shared publicationsLiang Ma
Department of Anatomy and Neurobiology, University of California, Irvine, CA 92697, USA
7 shared publications- Zifang Zhao
Department of Neurobiology and Behavior, Cornell University, Ithaca, NY 14853, USA
6 shared publications George D. Spyropoulos
Department of Electrical Engineering, Columbia University, New York, NY 10027, USA
5 shared publications
Latest Publications
- Open Access
Nucleus reuniens gates selective hippocampal-prefrontal interactions during NREM sleep
Memory consolidation requires functional synchrony between the hippocampus (HC) and the medial prefrontal cortex (mPFC). The nucleus reuniens (RE) is a structural and functional hub between HC and mPFC. Here, we used in vivo electrophysiology to monitor the hippocampal-thalamic-prefrontal network in rats during non-rapid eye movement (NREM) sleep. We identified ripple-like activity in the RE (120 Hz peak frequency, 45 ms oscillatory duration) that occurred most frequently during NREM sleep and was associated with robust recruitment of thalamic neural spiking. RE ripple activity was phase-locked to both hippocampal sharp wave-ripples (SWR) and mPFC ripples. Although ripples were independently detected in all three structures, we found that coupling between HC and mPFC ripples mainly involved co-occurring RE ripples. These results suggest RE ripples help organize when hippocampal activity engages prefrontal circuits during sleep, with potential implications for network mechanisms of memory consolidation.
Open AccessNucleus reuniens gates selective hippocampal-prefrontal interactions during NREM sleep
Memory consolidation requires functional synchrony between the hippocampus (HC) and the medial prefrontal cortex (mPFC). The nucleus reuniens (RE) is a structural and functional hub between HC and mPFC. Here, we used in vivo electrophysiology to monitor the hippocampal-thalamic-prefrontal network in rats during non-rapid eye movement (NREM) sleep. We identified ripple-like activity in the RE (120 Hz peak frequency, 45 ms oscillatory duration) that occurred most frequently during NREM sleep and was associated with robust recruitment of thalamic neural spiking. RE ripple activity was phase-locked to both hippocampal sharp wave-ripples (SWR) and mPFC ripples. Although ripples were independently detected in all three structures, we found that coupling between HC and mPFC ripples mainly involved co-occurring RE ripples. These results suggest RE ripples help organize when hippocampal activity engages prefrontal circuits during sleep, with potential implications for network mechanisms of memory consolidation.
- Open Access
- 10 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (28) , eaee9688
Implantable bioelectronic outlet
Developing a reliable, long-term electrical interface for implanted bioelectronics is essential for chronic diagnostics, therapeutics, and device maintenance. Here, we introduce the implantable bioelectronic outlet (IBO), a soft, tissue-like electronic interface that enables on-demand, direct ohmic connection between implanted electronics and external devices. IBO is composed of a conducting polymer–coated low-density polymer matrix that is jacketed with a hydrophobic elastomer, allowing repetitive insertion of external electrical contacts without crack propagation. IBO was functional after 1 year of implantation with minimal tissue effects. We demonstrate that IBO enables high-fidelity, bidirectional transmission of signals and power, including low-voltage neurophysiological signals, high-speed digital signals, neurostimulation protocols, and efficient high-current power delivery, validated in small and large animal model studies. The IBO provides a robust and scalable platform for safe, direct, and durable electrical interfacing with implantable bioelectronics.
- 10 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (28) , eaee9688
Open AccessImplantable bioelectronic outlet
Developing a reliable, long-term electrical interface for implanted bioelectronics is essential for chronic diagnostics, therapeutics, and device maintenance. Here, we introduce the implantable bioelectronic outlet (IBO), a soft, tissue-like electronic interface that enables on-demand, direct ohmic connection between implanted electronics and external devices. IBO is composed of a conducting polymer–coated low-density polymer matrix that is jacketed with a hydrophobic elastomer, allowing repetitive insertion of external electrical contacts without crack propagation. IBO was functional after 1 year of implantation with minimal tissue effects. We demonstrate that IBO enables high-fidelity, bidirectional transmission of signals and power, including low-voltage neurophysiological signals, high-speed digital signals, neurostimulation protocols, and efficient high-current power delivery, validated in small and large animal model studies. The IBO provides a robust and scalable platform for safe, direct, and durable electrical interfacing with implantable bioelectronics.
- Top Cited PapersOpen Access
- 15 January 2026
- Published by Springer Nature in Nature Sensors
- Vol. 1 (1) , 63-72
High-frequency, low-energy organic event-based sensors for closed-loop neurostimulation
Event-based bioelectronic sensors enable real-time detection and modulation of neural activity. However, conventional silicon interfaces are rigid and energy intensive, whereas organic electrochemical neuron (OECN)-based sensors, though promising, have been limited by slow firing rates, high energy use and scalability challenges. Here we present an OECN-based sensor capable of rapid, energy-efficient neural signal detection for closed-loop neurostimulation. These event-driven sensors respond within ~1 ms and generate voltage pulses up to 1.1 kHz, covering the full bandwidth of mammalian neuronal activity (0.5–1,000 Hz) while consuming only ~40 pJ per spike. Accurate detection of hippocampal interictal epileptiform discharges is demonstrated. Integrated with microelectrodes, these OECN-based sensors enable closed-loop neuromodulation by delivering real-time stimulation to suppress pathological sleep spindle oscillations in vivo. Combining biorealistic operation with ultra-low energy use, OECN-based sensors are good candidates for the next generation of implantable bioelectronics in energy-constrained environments.
- 15 January 2026
- Published by Springer Nature in Nature Sensors
- Vol. 1 (1) , 63-72
Top Cited PapersOpen AccessHigh-frequency, low-energy organic event-based sensors for closed-loop neurostimulation
Event-based bioelectronic sensors enable real-time detection and modulation of neural activity. However, conventional silicon interfaces are rigid and energy intensive, whereas organic electrochemical neuron (OECN)-based sensors, though promising, have been limited by slow firing rates, high energy use and scalability challenges. Here we present an OECN-based sensor capable of rapid, energy-efficient neural signal detection for closed-loop neurostimulation. These event-driven sensors respond within ~1 ms and generate voltage pulses up to 1.1 kHz, covering the full bandwidth of mammalian neuronal activity (0.5–1,000 Hz) while consuming only ~40 pJ per spike. Accurate detection of hippocampal interictal epileptiform discharges is demonstrated. Integrated with microelectrodes, these OECN-based sensors enable closed-loop neuromodulation by delivering real-time stimulation to suppress pathological sleep spindle oscillations in vivo. Combining biorealistic operation with ultra-low energy use, OECN-based sensors are good candidates for the next generation of implantable bioelectronics in energy-constrained environments.
- 9 January 2026
- Published by Springer Nature in Nature Materials
- Vol. 25 (3) , 349-350
Flexible two-dimensional neural sensors
- 9 January 2026
- Published by Springer Nature in Nature Materials
- Vol. 25 (3) , 349-350
Flexible two-dimensional neural sensors
- Open Access
- 20 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 10240
Implantable bioelectronics for gut electrophysiology
A major regulator of gastrointestinal physiology is the enteric nervous system. This division of the autonomic nervous system is unique in its extensiveness, with neurons distributed from the esophagus to the rectum, and its capability for local information processing. However, the constant motion of the gut, arising from its relative movements in the peritoneal cavity and the peristaltic movements associated with gut motility, as well as the sparse distribution of the neurons constituting the enteric nervous system, has made access and analysis exceedingly challenging. Here, we present the construction and validation of a bioelectronic implant for accessing neural information from the distal colon. Our bioelectronic monitoring system demonstrates real-time electrophysiological recording in response to chemical and mechanical distension under anesthesia and to feeding and stress in freely-moving animals. Direct access to the communication pathways of the enteric nervous system paves the way for neuromodulation strategies targeting the gut – brain axis.
- 20 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 10240
Open AccessImplantable bioelectronics for gut electrophysiology
A major regulator of gastrointestinal physiology is the enteric nervous system. This division of the autonomic nervous system is unique in its extensiveness, with neurons distributed from the esophagus to the rectum, and its capability for local information processing. However, the constant motion of the gut, arising from its relative movements in the peritoneal cavity and the peristaltic movements associated with gut motility, as well as the sparse distribution of the neurons constituting the enteric nervous system, has made access and analysis exceedingly challenging. Here, we present the construction and validation of a bioelectronic implant for accessing neural information from the distal colon. Our bioelectronic monitoring system demonstrates real-time electrophysiological recording in response to chemical and mechanical distension under anesthesia and to feeding and stress in freely-moving animals. Direct access to the communication pathways of the enteric nervous system paves the way for neuromodulation strategies targeting the gut – brain axis.
- Top Cited PapersOpen Access
- 23 June 2025
- Published by Springer Nature in Nature Neuroscience
- Vol. 28 (8) , 1753-1762
Closed-loop electrical stimulation prevents focal epilepsy progression and long-term memory impairment
Interictal epileptiform discharges (IEDs) are expressed in epileptic networks and disrupt cognitive functions. It is unclear whether addressing IED-induced dysfunction could improve epilepsy outcomes, as most therapeutic approaches target seizures. We show, in a kindling model of progressive focal epilepsy, that IEDs produce pathological oscillatory coupling associated with prolonged, hypersynchronous neural spiking in synaptically connected cortex and expand the brain territory capable of generating IEDs. A similar relationship between IED-mediated oscillatory coupling and temporal organization of IEDs across brain regions was identified in human participants with refractory focal epilepsy. Spatiotemporally targeted closed-loop electrical stimulation triggered on hippocampal IED occurrence eliminated the abnormal cortical activity patterns, preventing the spread of the epileptic network and ameliorating long-term spatial memory deficits in rodents. These findings suggest that stimulation-based network interventions that normalize interictal dynamics may be an effective treatment of epilepsy and its comorbidities, with a low barrier to clinical translation.
- 23 June 2025
- Published by Springer Nature in Nature Neuroscience
- Vol. 28 (8) , 1753-1762
Top Cited PapersOpen AccessClosed-loop electrical stimulation prevents focal epilepsy progression and long-term memory impairment
Interictal epileptiform discharges (IEDs) are expressed in epileptic networks and disrupt cognitive functions. It is unclear whether addressing IED-induced dysfunction could improve epilepsy outcomes, as most therapeutic approaches target seizures. We show, in a kindling model of progressive focal epilepsy, that IEDs produce pathological oscillatory coupling associated with prolonged, hypersynchronous neural spiking in synaptically connected cortex and expand the brain territory capable of generating IEDs. A similar relationship between IED-mediated oscillatory coupling and temporal organization of IEDs across brain regions was identified in human participants with refractory focal epilepsy. Spatiotemporally targeted closed-loop electrical stimulation triggered on hippocampal IED occurrence eliminated the abnormal cortical activity patterns, preventing the spread of the epileptic network and ameliorating long-term spatial memory deficits in rodents. These findings suggest that stimulation-based network interventions that normalize interictal dynamics may be an effective treatment of epilepsy and its comorbidities, with a low barrier to clinical translation.
- Top Cited Papers
- 28 April 2025
- Published by Springer Nature in Nature Reviews Neuroscience
- Vol. 26 (7) , 399-414
Interictal network dysfunction and cognitive impairment in epilepsy
Epilepsy is diagnosed when neural networks become capable of generating excessive or hypersynchronous activity patterns that result in observable seizures. In many cases, epilepsy is associated with cognitive comorbidities that persist between seizures and negatively impact quality of life. Dysregulation of the coordinated physiological network interactions that are required for cognitive function has been implicated in mediating these enduring symptoms, but the causal mechanisms are often elusive. Here, we provide an overview of neural network abnormalities with the potential to contribute to cognitive dysfunction in epilepsy. We examine these pathological interactions across spatial and temporal scales, additionally highlighting the dynamics that arise in response to the brain’s intrinsic capacity for plasticity. Understanding these processes will facilitate development of network-level interventions to address cognitive comorbidities that remain undertreated by currently available epilepsy therapeutics.
- 28 April 2025
- Published by Springer Nature in Nature Reviews Neuroscience
- Vol. 26 (7) , 399-414
Top Cited PapersInterictal network dysfunction and cognitive impairment in epilepsy
Epilepsy is diagnosed when neural networks become capable of generating excessive or hypersynchronous activity patterns that result in observable seizures. In many cases, epilepsy is associated with cognitive comorbidities that persist between seizures and negatively impact quality of life. Dysregulation of the coordinated physiological network interactions that are required for cognitive function has been implicated in mediating these enduring symptoms, but the causal mechanisms are often elusive. Here, we provide an overview of neural network abnormalities with the potential to contribute to cognitive dysfunction in epilepsy. We examine these pathological interactions across spatial and temporal scales, additionally highlighting the dynamics that arise in response to the brain’s intrinsic capacity for plasticity. Understanding these processes will facilitate development of network-level interventions to address cognitive comorbidities that remain undertreated by currently available epilepsy therapeutics.
- Open Access
- 4 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (14) , eadu2356
Contorted acene ribbons for stable and ultrasensitive neural probes
Organic materials that conduct both electrons and ions are integral to implantable bioelectronics because of their conformable nature. There is a dearth of these materials that are highly sensitive to cations, which are the majority ions on the surface of neurons. This manuscript offers a solution using an extended ribbon structure that is defect-free, providing high electronic mobility along its fused backbone, while the edge structure of these ribbons promotes high ionic conductivity. We incorporated these mixed ion/electron conductors into neural probes and implanted them in a rodent brain where they offer a suite of useful properties: high cation sensitivity, stability over several weeks after implantation, and biocompatibility. These materials represent an innovative class of implantable biosensors.
- 4 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (14) , eadu2356
Open AccessContorted acene ribbons for stable and ultrasensitive neural probes
Organic materials that conduct both electrons and ions are integral to implantable bioelectronics because of their conformable nature. There is a dearth of these materials that are highly sensitive to cations, which are the majority ions on the surface of neurons. This manuscript offers a solution using an extended ribbon structure that is defect-free, providing high electronic mobility along its fused backbone, while the edge structure of these ribbons promotes high ionic conductivity. We incorporated these mixed ion/electron conductors into neural probes and implanted them in a rodent brain where they offer a suite of useful properties: high cation sensitivity, stability over several weeks after implantation, and biocompatibility. These materials represent an innovative class of implantable biosensors.
- Open Access
- 9 January 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-12
Spatial control of doping in conducting polymers enables complementary, conformable, implantable internal ion-gated organic electrochemical transistors
Complementary transistors are critical for circuits with compatible input/output signal dynamic range and polarity. Organic electronics offer biocompatibility and conformability; however, generation of complementary organic transistors requires introduction of separate materials with inadequate stability and potential for tissue toxicity, limiting their use in biomedical applications. Here, we discovered that introduction of source/drain contact asymmetry enables spatial control of de/doping and creation of single-material complementary organic transistors from a variety of conducting polymers of both carrier types. When integrated with the vertical channel design and internal ion reservoirs of internal ion-gated organic electrochemical transistors, we produced matched complementary IGTs (cIGTs) that formed high-performance conformable amplifiers with 200 V/V uniform gain and 2 MHz bandwidth. These amplifiers showed long-term in vivo stability, and their miniaturized biocompatible design allowed implantation in developing rodents to monitor network maturation. cIGTs expand the use of organic electronics in standard circuit designs and enhance their biomedical potential.
- 9 January 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-12
Open AccessSpatial control of doping in conducting polymers enables complementary, conformable, implantable internal ion-gated organic electrochemical transistors
Complementary transistors are critical for circuits with compatible input/output signal dynamic range and polarity. Organic electronics offer biocompatibility and conformability; however, generation of complementary organic transistors requires introduction of separate materials with inadequate stability and potential for tissue toxicity, limiting their use in biomedical applications. Here, we discovered that introduction of source/drain contact asymmetry enables spatial control of de/doping and creation of single-material complementary organic transistors from a variety of conducting polymers of both carrier types. When integrated with the vertical channel design and internal ion reservoirs of internal ion-gated organic electrochemical transistors, we produced matched complementary IGTs (cIGTs) that formed high-performance conformable amplifiers with 200 V/V uniform gain and 2 MHz bandwidth. These amplifiers showed long-term in vivo stability, and their miniaturized biocompatible design allowed implantation in developing rodents to monitor network maturation. cIGTs expand the use of organic electronics in standard circuit designs and enhance their biomedical potential.
- Open Access
- 10 April 2024
- Published by Wiley in Advanced Science
- Vol. 11 (27) , e2308014
Formation of Anisotropic Conducting Interlayer for High‐Resolution Epidermal Electromyography Using Mixed‐Conducting Particulate Composite
Epidermal electrophysiology is a non‐invasive method used in research and clinical practices to study the electrical activity of the brain, heart, nerves, and muscles. However, electrode/tissue interlayer materials such as ionically conducting pastes can negatively affect recordings by introducing lateral electrode‐to‐electrode ionic crosstalk and reducing spatial resolution. To overcome this issue, biocompatible, anisotropic‐conducting interlayer composites (ACI) that establish an electrically anisotropic interface with the skin are developed, enabling the application of dense cutaneous sensor arrays. High‐density, conformable electrodes are also microfabricated that adhere to the ACI and follow the curvilinear surface of the skin. The results show that ACI significantly enhances the spatial resolution of epidermal electromyography (EMG) recording compared to conductive paste, permitting the acquisition of single muscle action potentials with distinct spatial profiles. The high‐density EMG in developing mice, non‐human primates, and humans is validated. Overall, high spatial‐resolution epidermal electrophysiology enabled by ACI has the potential to advance clinical diagnostics of motor system disorders and enhance data quality for human‐computer interface applications.
- 10 April 2024
- Published by Wiley in Advanced Science
- Vol. 11 (27) , e2308014
Open AccessFormation of Anisotropic Conducting Interlayer for High‐Resolution Epidermal Electromyography Using Mixed‐Conducting Particulate Composite
Epidermal electrophysiology is a non‐invasive method used in research and clinical practices to study the electrical activity of the brain, heart, nerves, and muscles. However, electrode/tissue interlayer materials such as ionically conducting pastes can negatively affect recordings by introducing lateral electrode‐to‐electrode ionic crosstalk and reducing spatial resolution. To overcome this issue, biocompatible, anisotropic‐conducting interlayer composites (ACI) that establish an electrically anisotropic interface with the skin are developed, enabling the application of dense cutaneous sensor arrays. High‐density, conformable electrodes are also microfabricated that adhere to the ACI and follow the curvilinear surface of the skin. The results show that ACI significantly enhances the spatial resolution of epidermal electromyography (EMG) recording compared to conductive paste, permitting the acquisition of single muscle action potentials with distinct spatial profiles. The high‐density EMG in developing mice, non‐human primates, and humans is validated. Overall, high spatial‐resolution epidermal electrophysiology enabled by ACI has the potential to advance clinical diagnostics of motor system disorders and enhance data quality for human‐computer interface applications.