Chuming Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chuming Zhao has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Karl Grosh
Department of Mechanical Engineering, University of Michigan
7 shared publications - Alison E. Hake
Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA
4 shared publications Karl Grosh
4 shared publicationsKatherine E. Knisely
Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
4 shared publicationsWang-Kyung Sung
Vesper Technologies, Inc., Boston, MA, USA
3 shared publicationsBryan E. Pfingst
Kresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, University of Michigan, Ann Arbor, MI, 48109, USA
2 shared publications
Latest Publications
- Open Access
- 15 August 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (19)
Metamaterial‐Augmented Head‐Mounted Audio Module
Recent developments in metamaterial research have shown promising progress in overcoming the fundamental physical limitations of acoustics. While the majority of this research is curiosity‐driven and focused on fundamental physics, there has been a scarcity of acoustic metamaterials research that can have a direct and immediate impact on real‐world applications. In this study, an acoustic metamaterial inside a head‐mounted audio module is incorporate to achieve a 3–7 dB broadband sound pressure level (SPL) improvement in the bass range (50–700 Hz), which is the most challenging frequency range for radiation enhancement. The adoption of the acoustic metamaterial not only enhances voltage sensitivity near the intrinsic metamaterial resonance frequency, but also extends the broadband enhancement to a lower transducer resonance frequency by carefully engineering the metamaterial‐transducer resonant coupling. The improvement of the audio module is demonstrated through fully coupled electrical‐mechanical‐acoustical numerical simulations using finite element analysis, which are validated against comprehensive measurements including electrical impedance analysis, speaker diaphragm displacement analysis, voltage sensitivity and power sensitivity analysis, and spectrogram. This study not only offers a promising path to improve the audio module quality without increasing the size, but also represents an important milestone toward using acoustic metamaterial research to solve audio industry challenges.
- 15 August 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (19)
Open AccessMetamaterial‐Augmented Head‐Mounted Audio Module
Recent developments in metamaterial research have shown promising progress in overcoming the fundamental physical limitations of acoustics. While the majority of this research is curiosity‐driven and focused on fundamental physics, there has been a scarcity of acoustic metamaterials research that can have a direct and immediate impact on real‐world applications. In this study, an acoustic metamaterial inside a head‐mounted audio module is incorporate to achieve a 3–7 dB broadband sound pressure level (SPL) improvement in the bass range (50–700 Hz), which is the most challenging frequency range for radiation enhancement. The adoption of the acoustic metamaterial not only enhances voltage sensitivity near the intrinsic metamaterial resonance frequency, but also extends the broadband enhancement to a lower transducer resonance frequency by carefully engineering the metamaterial‐transducer resonant coupling. The improvement of the audio module is demonstrated through fully coupled electrical‐mechanical‐acoustical numerical simulations using finite element analysis, which are validated against comprehensive measurements including electrical impedance analysis, speaker diaphragm displacement analysis, voltage sensitivity and power sensitivity analysis, and spectrogram. This study not only offers a promising path to improve the audio module quality without increasing the size, but also represents an important milestone toward using acoustic metamaterial research to solve audio industry challenges.
- Open Access
- 1 May 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (5) , 2733
Spatially selective active noise control systems
Active noise control (ANC) systems are commonly designed to achieve maximal sound reduction regardless of the incident direction of the sound. When desired sound is present, the state-of-the-art methods add a separate system to reconstruct it. This can result in distortion and latency. In this work, we propose a multi-channel ANC system that only reduces sound from undesired directions, and the system truly preserves the desired sound instead of reproducing it. The proposed algorithm imposes a spatial constraint on the hybrid ANC cost function to achieve spatial selectivity. Based on a six-channel microphone array on a pair of augmented eyeglasses, results show that the system minimized only noise coming from undesired directions. The control performance could be maintained even when the array was heavily perturbed. The proposed algorithm was also compared with the existing methods in the literature. Not only did the proposed system provide better noise reduction, but it also required much less effort. The binaural localization cues did not need to be reconstructed since the system preserved the physical sound wave from the desired source.
- 1 May 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (5) , 2733
Open AccessSpatially selective active noise control systems
Active noise control (ANC) systems are commonly designed to achieve maximal sound reduction regardless of the incident direction of the sound. When desired sound is present, the state-of-the-art methods add a separate system to reconstruct it. This can result in distortion and latency. In this work, we propose a multi-channel ANC system that only reduces sound from undesired directions, and the system truly preserves the desired sound instead of reproducing it. The proposed algorithm imposes a spatial constraint on the hybrid ANC cost function to achieve spatial selectivity. Based on a six-channel microphone array on a pair of augmented eyeglasses, results show that the system minimized only noise coming from undesired directions. The control performance could be maintained even when the array was heavily perturbed. The proposed algorithm was also compared with the existing methods in the literature. Not only did the proposed system provide better noise reduction, but it also required much less effort. The binaural localization cues did not need to be reconstructed since the system preserved the physical sound wave from the desired source.
- 3 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (16) , 17703-17711
Design and Experimental Assessment of Low-Noise Piezoelectric Microelectromechanical Systems Vibration Sensors
The ubiquity of vibration sensors and accelerometers, as well as advances in microfabrication technologies, have led to the development of implantable devices for biomedical applications. This work describes a piezoelectric microelectromechanical systems accelerometer designed for potential use in auditory prostheses. The design includes an aluminum nitride bimorph beam with a silicon proof mass. Analytic models of the device sensitivity and noise are presented. These lead to a minimum detectable acceleration cost function for the sensor that can be used to optimize sensor designs more effectively than typical sensitivity maximizing or electrical noise minimizing approaches. A fabricated device with a $1~\mu \text{m}$ thick, $100~\mu \text{m}$ long, and $700~\mu \text{m}$ wide beam and a $400~\mu \text{m}$ thick, $63~\mu \text{m}$ long, and $740~\mu \text{m}$ wide proof mass is tested experimentally. Results indicate accurate modeling of the system sensitivity up to the first resonant frequency (1420 Hz). The low-frequency sensitivity of the device is 1.3 mV/g, and the input referred noise is 36.3 nV/ $\sqrt {\mathrm{Hz}}$ at 100 Hz and 11.8 nV/ $\sqrt {\mathrm{Hz}}$ at 1 kHz. The resulting minimum detectable acceleration at 100 Hz and 1 kHz is $28~\mu \text{g}/\sqrt {\mathrm{Hz}}$ and $9.1~\mu \text{g}/\sqrt {\mathrm{Hz}}$ , respectively. A brief explanation of the use of the validated cost function for sensor design is provided, as well as an example comparing the piezoelectric sensor design to another from the literature. It is concluded that a traditional single-resonance design cannot compete with the performance of acoustic sensors; therefore, novel device designs must be considered for implantable auditory prosthesis applications.
- 3 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (16) , 17703-17711
Design and Experimental Assessment of Low-Noise Piezoelectric Microelectromechanical Systems Vibration Sensors
The ubiquity of vibration sensors and accelerometers, as well as advances in microfabrication technologies, have led to the development of implantable devices for biomedical applications. This work describes a piezoelectric microelectromechanical systems accelerometer designed for potential use in auditory prostheses. The design includes an aluminum nitride bimorph beam with a silicon proof mass. Analytic models of the device sensitivity and noise are presented. These lead to a minimum detectable acceleration cost function for the sensor that can be used to optimize sensor designs more effectively than typical sensitivity maximizing or electrical noise minimizing approaches. A fabricated device with a $1~\mu \text{m}$ thick, $100~\mu \text{m}$ long, and $700~\mu \text{m}$ wide beam and a $400~\mu \text{m}$ thick, $63~\mu \text{m}$ long, and $740~\mu \text{m}$ wide proof mass is tested experimentally. Results indicate accurate modeling of the system sensitivity up to the first resonant frequency (1420 Hz). The low-frequency sensitivity of the device is 1.3 mV/g, and the input referred noise is 36.3 nV/ $\sqrt {\mathrm{Hz}}$ at 100 Hz and 11.8 nV/ $\sqrt {\mathrm{Hz}}$ at 1 kHz. The resulting minimum detectable acceleration at 100 Hz and 1 kHz is $28~\mu \text{g}/\sqrt {\mathrm{Hz}}$ and $9.1~\mu \text{g}/\sqrt {\mathrm{Hz}}$ , respectively. A brief explanation of the use of the validated cost function for sensor design is provided, as well as an example comparing the piezoelectric sensor design to another from the literature. It is concluded that a traditional single-resonance design cannot compete with the performance of acoustic sensors; therefore, novel device designs must be considered for implantable auditory prosthesis applications.
- 5 October 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (14) , 143504
Ultraminiature AlN diaphragm acoustic transducer
Piezoelectric acoustic transducers consisting of a circular aluminum nitride and silicon nitride unimorph diaphragm and an encapsulated air-filled back cavity are reported. Analytical and finite element analysis models are used to design the transducer to achieve low minimum detectable pressure (MDP) within chosen size restrictions. A series of transducers with varying radii are fabricated using microelectromechanical systems (MEMS) techniques. Experimental results are reported for a transducer with a 175 μm radius on a 400 × 500 × 500 μm3 die exhibiting structural resonances at 552 kHz in air and 133 kHz in water. The low-frequency (10 Hz–50 kHz) sensitivity is 1.87 μV/Pa (−114.5 dB re 1 V/Pa) in both air and water. The sensor has an MDP of 43.7 mPa/ (67 dB SPL) at 100 Hz and 10.9 mPa/ (55 dB SPL) at 1 kHz. This work contributes a set of design rules for MEMS piezoelectric diaphragm transducers that focuses on decreasing the MDP of the sensor through size, material properties, and residual stress considerations.- 5 October 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (14) , 143504
Ultraminiature AlN diaphragm acoustic transducer
Piezoelectric acoustic transducers consisting of a circular aluminum nitride and silicon nitride unimorph diaphragm and an encapsulated air-filled back cavity are reported. Analytical and finite element analysis models are used to design the transducer to achieve low minimum detectable pressure (MDP) within chosen size restrictions. A series of transducers with varying radii are fabricated using microelectromechanical systems (MEMS) techniques. Experimental results are reported for a transducer with a 175 μm radius on a 400 × 500 × 500 μm3 die exhibiting structural resonances at 552 kHz in air and 133 kHz in water. The low-frequency (10 Hz–50 kHz) sensitivity is 1.87 μV/Pa (−114.5 dB re 1 V/Pa) in both air and water. The sensor has an MDP of 43.7 mPa/ (67 dB SPL) at 100 Hz and 10.9 mPa/ (55 dB SPL) at 1 kHz. This work contributes a set of design rules for MEMS piezoelectric diaphragm transducers that focuses on decreasing the MDP of the sensor through size, material properties, and residual stress considerations.- Open Access
- 6 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-11
Voltage readout from a piezoelectric intracochlear acoustic transducer implanted in a living guinea pig
The ability to measure the voltage readout from a sensor implanted inside the living cochlea enables continuous monitoring of intracochlear acoustic pressure locally, which could improve cochlear implants. We developed a piezoelectric intracochlear acoustic transducer (PIAT) designed to sense the acoustic pressure while fully implanted inside a living guinea pig cochlea. The PIAT, fabricated using micro-electro-mechanical systems (MEMS) techniques, consisted of an array of four piezoelectric cantilevers with varying lengths to enhance sensitivity across a wide frequency bandwidth. Prior to implantation, benchtop tests were conducted to characterize the device performance in air and in water. When implanted in the cochlea of an anesthetized guinea pig, the in vivo voltage response from the PIAT was measured in response to 80–95 dB sound pressure level 1–14 kHz sinusoidal acoustic excitation at the entrance of the guinea pig’s ear canal. All sensed signals were above the noise floor and unaffected by crosstalk from the cochlear microphonic or external electrical interference. These results demonstrate that external acoustic stimulus can be sensed via the piezoelectric voltage response of the implanted MEMS transducer inside the living cochlea, providing key steps towards developing intracochlear acoustic sensors to replace external or subcutaneous microphones for auditory prosthetics.
- 6 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-11
Open AccessVoltage readout from a piezoelectric intracochlear acoustic transducer implanted in a living guinea pig
The ability to measure the voltage readout from a sensor implanted inside the living cochlea enables continuous monitoring of intracochlear acoustic pressure locally, which could improve cochlear implants. We developed a piezoelectric intracochlear acoustic transducer (PIAT) designed to sense the acoustic pressure while fully implanted inside a living guinea pig cochlea. The PIAT, fabricated using micro-electro-mechanical systems (MEMS) techniques, consisted of an array of four piezoelectric cantilevers with varying lengths to enhance sensitivity across a wide frequency bandwidth. Prior to implantation, benchtop tests were conducted to characterize the device performance in air and in water. When implanted in the cochlea of an anesthetized guinea pig, the in vivo voltage response from the PIAT was measured in response to 80–95 dB sound pressure level 1–14 kHz sinusoidal acoustic excitation at the entrance of the guinea pig’s ear canal. All sensed signals were above the noise floor and unaffected by crosstalk from the cochlear microphonic or external electrical interference. These results demonstrate that external acoustic stimulus can be sensed via the piezoelectric voltage response of the implanted MEMS transducer inside the living cochlea, providing key steps towards developing intracochlear acoustic sensors to replace external or subcutaneous microphones for auditory prosthetics.
- 1 June 2018
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 275, 29-36
Design and fabrication of a piezoelectric MEMS xylophone transducer with a flexible electrical connection
- 1 June 2018
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 275, 29-36
Design and fabrication of a piezoelectric MEMS xylophone transducer with a flexible electrical connection
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1804
Miniature implantable low noise piezoelectric diaphragm sound sensor
Piezoelectric diaphragm sound sensors must be miniaturized and environmentally toughened for use in biomedical applications. We study two disparate applications of the sensor, first as the front end of a completely implantable cochlear implant and the second as an intracardiac pressure sensor. The sensor, which is fabricated using micro-electrical-mechanical-system (MEMS) techniques, consists of a circular diaphragm with at least one aluminum nitride (AlN) based piezoelectric layer backed by an air-filled cavity. The sensors are designed to have a lower input referred noise (IRN) compared to other miniaturized piezoelectric diaphragm hydrophones with similar diaphragm size via structural design and electrode area optimization. Sensors are fabricated with varying diaphragm diameters from 300 to 450 μm to test the effect of residual stresses due to the manufacturing process on the frequency bandwidth and IRN. The sensor works in air and underwater with the same sensitivity, but the frequency bandwidth is reduced underwater compared to that is in air because of the water mass loading. A finite element analysis model using COMSOL is built to study the in air and underwater sensing process and the IRN.
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1804
Miniature implantable low noise piezoelectric diaphragm sound sensor
Piezoelectric diaphragm sound sensors must be miniaturized and environmentally toughened for use in biomedical applications. We study two disparate applications of the sensor, first as the front end of a completely implantable cochlear implant and the second as an intracardiac pressure sensor. The sensor, which is fabricated using micro-electrical-mechanical-system (MEMS) techniques, consists of a circular diaphragm with at least one aluminum nitride (AlN) based piezoelectric layer backed by an air-filled cavity. The sensors are designed to have a lower input referred noise (IRN) compared to other miniaturized piezoelectric diaphragm hydrophones with similar diaphragm size via structural design and electrode area optimization. Sensors are fabricated with varying diaphragm diameters from 300 to 450 μm to test the effect of residual stresses due to the manufacturing process on the frequency bandwidth and IRN. The sensor works in air and underwater with the same sensitivity, but the frequency bandwidth is reduced underwater compared to that is in air because of the water mass loading. A finite element analysis model using COMSOL is built to study the in air and underwater sensing process and the IRN.
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1804
Experimental assessment of miniature accelerometers designed for sensing middle ear motion
Sensing human middle ear motion requires miniature, low-noise sensors to detect low-amplitude vibration of the ossicle bones to replace the external microphone in a cochlear implant system. Specifically, a 35 μg/√Hz sensor resolution is needed measure motion at 500 Hz (Young et al., 2012). Motivated by sensing middle ear motion without irreversible alteration to the ossicular chain, a small, piezoelectric accelerometer is considered. Our detailed low-frequency analytical model is used to identify promising micromachined, piezoelectric bimorph cantilever accelerometer designs. We fabricated a first generation of accelerometers using a conservative microfabrication approach, taken to enhance the yield of devices rather than to minimize the input referred noise (IRN). The mathematical model was validated by voltage actuation testing of these accelerometers. The device sensitivity to acceleration is tested, and the resulting IRN is desired to assess the viability of the sensor for the middle ear motion application. The first generation experimental results are compared to the mathematical model to determine the accuracy of the model and the efficacy of the fabrication methodology. This knowledge will influence future sensor designs optimized for minimal IRN.
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1804
Experimental assessment of miniature accelerometers designed for sensing middle ear motion
Sensing human middle ear motion requires miniature, low-noise sensors to detect low-amplitude vibration of the ossicle bones to replace the external microphone in a cochlear implant system. Specifically, a 35 μg/√Hz sensor resolution is needed measure motion at 500 Hz (Young et al., 2012). Motivated by sensing middle ear motion without irreversible alteration to the ossicular chain, a small, piezoelectric accelerometer is considered. Our detailed low-frequency analytical model is used to identify promising micromachined, piezoelectric bimorph cantilever accelerometer designs. We fabricated a first generation of accelerometers using a conservative microfabrication approach, taken to enhance the yield of devices rather than to minimize the input referred noise (IRN). The mathematical model was validated by voltage actuation testing of these accelerometers. The device sensitivity to acceleration is tested, and the resulting IRN is desired to assess the viability of the sensor for the middle ear motion application. The first generation experimental results are compared to the mathematical model to determine the accuracy of the model and the efficacy of the fabrication methodology. This knowledge will influence future sensor designs optimized for minimal IRN.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 16-19
Modeling, fabrication, and testing of a MEMS multichannel aln transducer for a completely implantable cochelar implant
An implantable acoustic transducer is crucial for a completely implantable cochlear implant (CICI). This paper presents a miniaturized multichannel aluminum nitride (AlN) transducer designed to fit inside a guinea pig cochlea and act as a front end of a CICI. The transducer, fabricated using microelectromechanical systems techniques, has four piezoelectric bimorphs to produce broadband enhanced sensitivity. Transducer functionality is demonstrated via in-air and underwater actuation and acoustic sensing. A finite element analysis model is developed to design the transducer and understand its frequency behavior. The modeled results provide a good match with the experimental results.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 16-19
Modeling, fabrication, and testing of a MEMS multichannel aln transducer for a completely implantable cochelar implant
An implantable acoustic transducer is crucial for a completely implantable cochlear implant (CICI). This paper presents a miniaturized multichannel aluminum nitride (AlN) transducer designed to fit inside a guinea pig cochlea and act as a front end of a CICI. The transducer, fabricated using microelectromechanical systems techniques, has four piezoelectric bimorphs to produce broadband enhanced sensitivity. Transducer functionality is demonstrated via in-air and underwater actuation and acoustic sensing. A finite element analysis model is developed to design the transducer and understand its frequency behavior. The modeled results provide a good match with the experimental results.
- 1 May 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 141 (5_Suppleme) , 4016
Miniature accelerometers for sensing middle ear motion
Acceleration sensors are prevalent in handheld electronics, navigation systems, and physical activity monitors as well as for vibration measurement. There are many measurement applications, such as sensing human middle ear motion, that require miniature, low-noise sensors to detect low-amplitude vibration. Both capacitive and piezoresistive MEMS accelerometers have been used for vibration sensing of the middle ear. Recent capacitive designs are large (base area of 2.5 mm x 6.2 mm) and have a limited bandwidth of 6.44 kHz. Low-noise piezoresistive devices power requirements are high for hearing instruments, greater than 1 mW. Commercial piezoelectric accelerometers are a viable means for vibration detection; while small, they are still large and lacking proper electronic connections for middle ear sensing applications. The aforementioned problems motivate the design of a small, passive, broadband accelerometer with low input referred noise (IRN). In this work, we design a micromachined, piezoelectric bimorph cantilever accelerometer for broadband, low-amplitude vibration sensing. An analytic model is developed to minimize the IRN. The analytic expression allows for rapid design of many system parameters that are verified through finite element analysis.
- 1 May 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 141 (5_Suppleme) , 4016
Miniature accelerometers for sensing middle ear motion
Acceleration sensors are prevalent in handheld electronics, navigation systems, and physical activity monitors as well as for vibration measurement. There are many measurement applications, such as sensing human middle ear motion, that require miniature, low-noise sensors to detect low-amplitude vibration. Both capacitive and piezoresistive MEMS accelerometers have been used for vibration sensing of the middle ear. Recent capacitive designs are large (base area of 2.5 mm x 6.2 mm) and have a limited bandwidth of 6.44 kHz. Low-noise piezoresistive devices power requirements are high for hearing instruments, greater than 1 mW. Commercial piezoelectric accelerometers are a viable means for vibration detection; while small, they are still large and lacking proper electronic connections for middle ear sensing applications. The aforementioned problems motivate the design of a small, passive, broadband accelerometer with low input referred noise (IRN). In this work, we design a micromachined, piezoelectric bimorph cantilever accelerometer for broadband, low-amplitude vibration sensing. An analytic model is developed to minimize the IRN. The analytic expression allows for rapid design of many system parameters that are verified through finite element analysis.