Pankaj Kumar Mohanty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pankaj Kumar Mohanty has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Abdul Razak
Department of Neonatology, Manipal Hospital, Bangalore, Karnataka, India
2 shared publications- Sweta Singh
Obstetrics and Gynecology, All India Institute of Medical Sciences, Bhubaneswar, Bhubaneswar, IND
2 shared publications Tapas Kumar Som
Department of Neonatology, DM Neonatology, NICU Department, AIIMS Bhubaneswar, Bhubaneswar, India
2 shared publicationsAmit Kumar Satapathy
Pediatrics, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India
1 shared publicationAnil Kumar Puralingegowda
Department of Paediatric Surgery, Manipal Hospital, Bangalore, Karnataka, India
1 shared publicationBikasha Bihari Tripathy
Pediatric Surgery, All India Institute of Medical Sciences, Bhubaneswar, Bhubaneswar, IND
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by S. Karger AG in Biomedicine Hub
- Vol. 9 (1) , 1-8
Comparison of Ultrasound-Guided Umbilical Venous Catheter Insertion with Blind Method: A Randomized Controlled Trial
Introduction: Ultrasonography (USG) can be used in neonates to manipulate and place the umbilical catheter in the correct position. Although chest radiograph (CXR) is the gold standard, a noninvasive method like USG without radiation exposure may be an alternative bedside armamentarium to the clinician. The purpose of the study was to evaluate whether USG-guided umbilical venous catheter (UVC) insertion is superior to the conventional method for the successful insertion of UVC. Method: The neonates born between 25 and 42 weeks of gestation requiring parenteral fluids and admission to neonatal intensive care unit (NICU) between September 2020 and November 2022 were randomized in two weight-based strata: ≤1,200 and >1,200 g. USG-guided UVC insertion was done in the intervention group and blind UVC insertion was done in the control group. Results: Out of 112 enrolled neonates, 58 were in the USG-guided group and 54 in the blind group. There was no significant difference in the failure rate between the intervention and control groups (20% versus 29% [RR: 0.69, 95% CI: 0.36–1.33]). The sensitivity and specificity of USG in locating tip position were 97 and 46.8%, respectively. The mean procedure time in USG and blind groups was 8.9 and 8.3 min, respectively (p value 0.56). Conclusion: USG does not reduce the failure rates during the insertion of umbilical catheters. However, being a safe, noninvasive procedure, it can be considered a rescue modality to CXR in NICUs equipped with portable USG for guiding UVC insertion.
- 1 January 2024
- Published by S. Karger AG in Biomedicine Hub
- Vol. 9 (1) , 1-8
Open AccessComparison of Ultrasound-Guided Umbilical Venous Catheter Insertion with Blind Method: A Randomized Controlled Trial
Introduction: Ultrasonography (USG) can be used in neonates to manipulate and place the umbilical catheter in the correct position. Although chest radiograph (CXR) is the gold standard, a noninvasive method like USG without radiation exposure may be an alternative bedside armamentarium to the clinician. The purpose of the study was to evaluate whether USG-guided umbilical venous catheter (UVC) insertion is superior to the conventional method for the successful insertion of UVC. Method: The neonates born between 25 and 42 weeks of gestation requiring parenteral fluids and admission to neonatal intensive care unit (NICU) between September 2020 and November 2022 were randomized in two weight-based strata: ≤1,200 and >1,200 g. USG-guided UVC insertion was done in the intervention group and blind UVC insertion was done in the control group. Results: Out of 112 enrolled neonates, 58 were in the USG-guided group and 54 in the blind group. There was no significant difference in the failure rate between the intervention and control groups (20% versus 29% [RR: 0.69, 95% CI: 0.36–1.33]). The sensitivity and specificity of USG in locating tip position were 97 and 46.8%, respectively. The mean procedure time in USG and blind groups was 8.9 and 8.3 min, respectively (p value 0.56). Conclusion: USG does not reduce the failure rates during the insertion of umbilical catheters. However, being a safe, noninvasive procedure, it can be considered a rescue modality to CXR in NICUs equipped with portable USG for guiding UVC insertion.
- 6 December 2022
- Published by Springer Nature in Journal of Ultrasound
- Vol. 26 (4) , 777-784
Routine third trimester ultrasonography in predicting adverse perinatal outcomes: a prospective cohort study at a tertiary-care hospital in Eastern India
Aims Fetal growth restriction (FGR) may go undetected in the antenatal period with subjective clinical evaluation, and there is a growing propensity to perform a third-trimester scan, especially in the developed countries. The literature on the importance of the same in developing countries like ours, is scant. Hence, this study was undertaken to evaluate the role of routine third-trimester ultrasonography along with Doppler in predicting adverse perinatal outcome. Methods A prospective cohort study was conducted at a tertiary-care hospital, in which routine third-trimester ultrasonography was performed for 265 antenatal women, and included estimation of amniotic fluid index (AFI), estimated fetal-weight (EFW), and cerebroplacental ratio (CPR). Women were categorized as having normal parameters or having at least one abnormal parameter. Post-natal adverse perinatal outcomes including low birth-weight, hypoglycemia, poor Apgar scores, prolonged hospital stay, need for ventilatory support, neonatal asphyxia, neonatal sepsis and early neonatal death were recorded. Prediction analyses for sensitivity, specificity, positive and negative predictive values were done. Receiver Operating Characteristic (ROC) curves were plotted for threshold for each parameter for adverse outcome. Results Out of 260 women that were analyzed, 47.5% had no clinically identifiable risk factors, and 52.5% had at least one abnormal parameter. Sensitivity and negative predictive value for adverse outcome were highest for composite ultrasound finding (85.4% and 90.4% respectively). Specificity, positive predictive value and diagnostic accuracy were highest for CPR (97.8%, 86.7% and 76.9% respectively). Conclusion Routine third trimester ultrasonography, including Doppler, can help in risk-stratification of otherwise clinically low-risk pregnancies.
- 6 December 2022
- Published by Springer Nature in Journal of Ultrasound
- Vol. 26 (4) , 777-784
Routine third trimester ultrasonography in predicting adverse perinatal outcomes: a prospective cohort study at a tertiary-care hospital in Eastern India
Aims Fetal growth restriction (FGR) may go undetected in the antenatal period with subjective clinical evaluation, and there is a growing propensity to perform a third-trimester scan, especially in the developed countries. The literature on the importance of the same in developing countries like ours, is scant. Hence, this study was undertaken to evaluate the role of routine third-trimester ultrasonography along with Doppler in predicting adverse perinatal outcome. Methods A prospective cohort study was conducted at a tertiary-care hospital, in which routine third-trimester ultrasonography was performed for 265 antenatal women, and included estimation of amniotic fluid index (AFI), estimated fetal-weight (EFW), and cerebroplacental ratio (CPR). Women were categorized as having normal parameters or having at least one abnormal parameter. Post-natal adverse perinatal outcomes including low birth-weight, hypoglycemia, poor Apgar scores, prolonged hospital stay, need for ventilatory support, neonatal asphyxia, neonatal sepsis and early neonatal death were recorded. Prediction analyses for sensitivity, specificity, positive and negative predictive values were done. Receiver Operating Characteristic (ROC) curves were plotted for threshold for each parameter for adverse outcome. Results Out of 260 women that were analyzed, 47.5% had no clinically identifiable risk factors, and 52.5% had at least one abnormal parameter. Sensitivity and negative predictive value for adverse outcome were highest for composite ultrasound finding (85.4% and 90.4% respectively). Specificity, positive predictive value and diagnostic accuracy were highest for CPR (97.8%, 86.7% and 76.9% respectively). Conclusion Routine third trimester ultrasonography, including Doppler, can help in risk-stratification of otherwise clinically low-risk pregnancies.
- Open Access
- 1 February 2022
- Published by Elmer Press, Inc. in Journal of Endocrinology and Metabolism
- Vol. 12 (1) , 32-39
Predictors of Antenatal Insulin Requirement in Women With Gestational Diabetes Mellitus: A Prospective Observational Cohort Study
Background: The treatment of gestational diabetes mellitus (GDM) includes medical nutrition therapy (MNT), and insulin if MNT fails to achieve glycemic control. Limited data are available on predictors of insulin requirement in pregnancy and the difference in obstetric outcomes between the two treatment groups. This study was conducted with the primary objective of identifying predictors of antenatal insulin requirement and the secondary objective of comparing perinatal outcomes in MNT-treated versus insulin-treated groups. Methods: It was a prospective cohort study at a tertiary care institute in eastern India. Antenatal women were diagnosed with GDM as per the Diabetes in Pregnancy Study Group of India criteria and received MNT for 1 - 2 weeks, depending on gestational age, followed by self-monitoring of blood glucose. Insulin therapy was added in those who could not meet the target blood glucose. Maternal and neonatal outcomes were studied in these two groups and an attempt was made to identify the predictors of antenatal insulin requirement. The perinatal outcomes in MNT-treated versus insulin-treated groups were also compared. Results: Data of 151 participants were analyzed. Eighty percent were controlled with MNT. Gestational age ? 33.28 weeks at diagnosis of GDM, maternal BMI ? 24.7 kg/m2 and 75-gram oral glucose tolerance test (75-g OGTT) value ? 162 mg/dL were predictors of antenatal insulin requirement. The median age, weight, body mass index (BMI), value of 75-g OGTT at diagnosis of GDM, number of cesarean deliveries, gestational hypertension and neonatal hyperbilirubinemia were significantly higher in the insulin group. Conclusion: Gestational age at diagnosis of GDM, BMI and value of 75-g OGTT predicted antenatal insulin requirement. Gestational hypertension, rate of cesarean deliveries and neonatal hyperbilirubinemia were significantly higher in the insulin group. J Endocrinol Metab. 2022;12(1):32-39 doi: https://doi.org/10.14740/jem793
- 1 February 2022
- Published by Elmer Press, Inc. in Journal of Endocrinology and Metabolism
- Vol. 12 (1) , 32-39
Open AccessPredictors of Antenatal Insulin Requirement in Women With Gestational Diabetes Mellitus: A Prospective Observational Cohort Study
Background: The treatment of gestational diabetes mellitus (GDM) includes medical nutrition therapy (MNT), and insulin if MNT fails to achieve glycemic control. Limited data are available on predictors of insulin requirement in pregnancy and the difference in obstetric outcomes between the two treatment groups. This study was conducted with the primary objective of identifying predictors of antenatal insulin requirement and the secondary objective of comparing perinatal outcomes in MNT-treated versus insulin-treated groups. Methods: It was a prospective cohort study at a tertiary care institute in eastern India. Antenatal women were diagnosed with GDM as per the Diabetes in Pregnancy Study Group of India criteria and received MNT for 1 - 2 weeks, depending on gestational age, followed by self-monitoring of blood glucose. Insulin therapy was added in those who could not meet the target blood glucose. Maternal and neonatal outcomes were studied in these two groups and an attempt was made to identify the predictors of antenatal insulin requirement. The perinatal outcomes in MNT-treated versus insulin-treated groups were also compared. Results: Data of 151 participants were analyzed. Eighty percent were controlled with MNT. Gestational age ? 33.28 weeks at diagnosis of GDM, maternal BMI ? 24.7 kg/m2 and 75-gram oral glucose tolerance test (75-g OGTT) value ? 162 mg/dL were predictors of antenatal insulin requirement. The median age, weight, body mass index (BMI), value of 75-g OGTT at diagnosis of GDM, number of cesarean deliveries, gestational hypertension and neonatal hyperbilirubinemia were significantly higher in the insulin group. Conclusion: Gestational age at diagnosis of GDM, BMI and value of 75-g OGTT predicted antenatal insulin requirement. Gestational hypertension, rate of cesarean deliveries and neonatal hyperbilirubinemia were significantly higher in the insulin group. J Endocrinol Metab. 2022;12(1):32-39 doi: https://doi.org/10.14740/jem793
- Open Access
- 4 August 2021
- Published by Springer Nature in Cureus
- Vol. 13 (8)
Intestinal Failure in a Neonate: A Surgical Emergency and Medical Catastrophe
In this case report, we present a female neonate referred to us, born to a primigravida mother al 39 weeks, who cried after birth, did not require any resuscitation, had a birth weight of 2.9 kg and developed abdominal distension and bilious vomiting on Day 1 of life. Ultrasound abdomen and X-ray imaging were suggestive of midgut volvulus with malrotation. The emergency explorative laparotomy revealed the small bowel to be gangrenous in extensive areas, and 10 cm of the small intestine was successfully preserved. The baby was admitted to the NICU and required three months of total parenteral nutrition. In between, the baby was managed successfully for sepsis, septic shock, diarrhea, and dehydration, Later, she was discharged, and is currently being followed up. AL the first follow-up, the baby was noted to be gaining weight and has developed no complications to date.
- 4 August 2021
- Published by Springer Nature in Cureus
- Vol. 13 (8)
Open AccessIntestinal Failure in a Neonate: A Surgical Emergency and Medical Catastrophe
In this case report, we present a female neonate referred to us, born to a primigravida mother al 39 weeks, who cried after birth, did not require any resuscitation, had a birth weight of 2.9 kg and developed abdominal distension and bilious vomiting on Day 1 of life. Ultrasound abdomen and X-ray imaging were suggestive of midgut volvulus with malrotation. The emergency explorative laparotomy revealed the small bowel to be gangrenous in extensive areas, and 10 cm of the small intestine was successfully preserved. The baby was admitted to the NICU and required three months of total parenteral nutrition. In between, the baby was managed successfully for sepsis, septic shock, diarrhea, and dehydration, Later, she was discharged, and is currently being followed up. AL the first follow-up, the baby was noted to be gaining weight and has developed no complications to date.
- 28 November 2018
- Published by BMJ in BMJ Case Reports
- Vol. 11 (1) , e224769
Difficult intubation in a neonate: a diagnostic dilemma
Difficult intubation in neonates has innumerable aetiologies. It especially poses a formidable challenge to save a newborn baby immediately after birth where antenatal details are unavailable. A late preterm neonate was born limp and apnoeic. Several attempts to intubate the baby were unsuccessful. Possibility of subglottic obstruction was considered. The baby died of severe perinatal asphyxia. Autopsy showed a mass around the airway which turned out to be ectopic thymus on histopathology. Ectopic thymus can present as periglottic mass without externally visible cervical swelling and can cause difficult intubation which may lead to serious adverse outcome including death if not anticipated early and managed accordingly.
- 28 November 2018
- Published by BMJ in BMJ Case Reports
- Vol. 11 (1) , e224769
Difficult intubation in a neonate: a diagnostic dilemma
Difficult intubation in neonates has innumerable aetiologies. It especially poses a formidable challenge to save a newborn baby immediately after birth where antenatal details are unavailable. A late preterm neonate was born limp and apnoeic. Several attempts to intubate the baby were unsuccessful. Possibility of subglottic obstruction was considered. The baby died of severe perinatal asphyxia. Autopsy showed a mass around the airway which turned out to be ectopic thymus on histopathology. Ectopic thymus can present as periglottic mass without externally visible cervical swelling and can cause difficult intubation which may lead to serious adverse outcome including death if not anticipated early and managed accordingly.
- 3 December 2014
- Published by BMJ in BMJ Case Reports
- Vol. 2014
Anteromedial pneumothorax in a neonate: ‘The diagnostic dilemma’ and the importance of clinical signs
A premature neonate born at 32 weeks of gestation was admitted to the neonatal unit with respiratory distress syndrome. The infant received late rescue surfactant therapy with continued mechanical ventilation in view of continuous positive airway pressure (CPAP) failure. Owing to worsening distress and an air leak, he was switched over to high-frequency oscillatory ventilation. The air leak required drainage for possible pneumopericardium. This was initially attempted ineffectually with echo-assisted pericardial drainage, and later successfully with the use of chest tubes for anteromedial pneumothorax.
- 3 December 2014
- Published by BMJ in BMJ Case Reports
- Vol. 2014
Anteromedial pneumothorax in a neonate: ‘The diagnostic dilemma’ and the importance of clinical signs
A premature neonate born at 32 weeks of gestation was admitted to the neonatal unit with respiratory distress syndrome. The infant received late rescue surfactant therapy with continued mechanical ventilation in view of continuous positive airway pressure (CPAP) failure. Owing to worsening distress and an air leak, he was switched over to high-frequency oscillatory ventilation. The air leak required drainage for possible pneumopericardium. This was initially attempted ineffectually with echo-assisted pericardial drainage, and later successfully with the use of chest tubes for anteromedial pneumothorax.
- Open Access
- 8 July 2014
- Published by BMJ in BMJ Case Reports
- Vol. 2014
Neonatal intestinal obstruction secondary to a small bowel duplication cyst
A 3-week-old neonate developed abdominal distension and vomiting which subsided after conservative management. However, there was a recurrence of symptoms for which a lower gastrointestinal tract contrast study was performed. The infant had a filling defect in the area of the transverse colon. A CT scan was performed, showing a duplication cyst arising from the small bowel and indenting the transverse colon. Resection of the duplication cyst and end-to-end anastomosis of the bowel was performed. The duplication cyst was of tubular type, and a sealed perforation was noted in the cyst wall.
- 8 July 2014
- Published by BMJ in BMJ Case Reports
- Vol. 2014
Open AccessNeonatal intestinal obstruction secondary to a small bowel duplication cyst
A 3-week-old neonate developed abdominal distension and vomiting which subsided after conservative management. However, there was a recurrence of symptoms for which a lower gastrointestinal tract contrast study was performed. The infant had a filling defect in the area of the transverse colon. A CT scan was performed, showing a duplication cyst arising from the small bowel and indenting the transverse colon. Resection of the duplication cyst and end-to-end anastomosis of the bowel was performed. The duplication cyst was of tubular type, and a sealed perforation was noted in the cyst wall.