Levi Patrick Neukirch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Levi Patrick Neukirch has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Matthew Stouten Freeman
Los Alamos National Laboratory
7 shared publications - Fesseha Mariam
Los Alamos National Laboratory , Los Alamos, New Mexico 81745
4 shared publications - J. L. Schmidt
Los Alamos National Laboratory , Bikini Atoll Rd., Los Alamos, New Mexico 87545
4 shared publications - Zhaowen Tang
Los Alamos National Laboratory
4 shared publications - Christopher L. Morris
Los Alamos National Laboratory
3 shared publications - J. C. Allison
Los Alamos National Laboratory 1 , Los Alamos, New Mexico 87545, USA
3 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
Adjustable collimation for dark-field proton radiography contrast enhancement
A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
Open AccessAdjustable collimation for dark-field proton radiography contrast enhancement
A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.
- Open Access
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center
The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Open AccessA profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center
The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.
- Open Access
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Design and commissioning of the PRIOR-II “proton microscope for FAIR”
A new high energy proton radiography facility PRIOR-II (Proton Microscope for FAIR) has been designed, constructed, and successfully commissioned at the GSI Helmholtzzentrum für Schwerionenforschung (Darmstadt, Germany) pushing the technical boundaries of charged particle radiography with normal conducting magnets to the limits. The setup is foreseen to become a new and powerful user facility for carrying out fundamental science experiments in the fields of plasma and shock wave physics, material science, and medical physics. It will help address several unsolved scientific challenges, which require high-speed and precise non-invasive diagnostic methods capable of probing matter with up to 100 g/cm2 areal density. PRIOR-II is specifically designed to utilize the full timing capabilities of the SIS-18 synchrotron at GSI for ultra-fast dynamic experiments with up to 4 GeV protons and will also be fielded at the future FAIR facility, where higher proton energies and beam intensities will be available. This will enable experiment geometries with even higher areal densities, more flexible experiment timing, and further enhanced spatial resolution.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Open AccessDesign and commissioning of the PRIOR-II “proton microscope for FAIR”
A new high energy proton radiography facility PRIOR-II (Proton Microscope for FAIR) has been designed, constructed, and successfully commissioned at the GSI Helmholtzzentrum für Schwerionenforschung (Darmstadt, Germany) pushing the technical boundaries of charged particle radiography with normal conducting magnets to the limits. The setup is foreseen to become a new and powerful user facility for carrying out fundamental science experiments in the fields of plasma and shock wave physics, material science, and medical physics. It will help address several unsolved scientific challenges, which require high-speed and precise non-invasive diagnostic methods capable of probing matter with up to 100 g/cm2 areal density. PRIOR-II is specifically designed to utilize the full timing capabilities of the SIS-18 synchrotron at GSI for ultra-fast dynamic experiments with up to 4 GeV protons and will also be fielded at the future FAIR facility, where higher proton energies and beam intensities will be available. This will enable experiment geometries with even higher areal densities, more flexible experiment timing, and further enhanced spatial resolution.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Large-grain scintillator screens for proton radiography
Protons from the Los Alamos Neutron Science Center have been used for pulsed radiography in dynamic experiments for the past 25 years. Pulses of protons are imaged on a scintillator, and the light from these images is captured by fast gated cameras. The need for fast, bright scintillators has led to some compromises in image quality due to tiling the scintillators and backgrounds with totally internally reflected light. We show how large-grain scintillator screens, made using a thin plastic binder, solve these problems.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Large-grain scintillator screens for proton radiography
Protons from the Los Alamos Neutron Science Center have been used for pulsed radiography in dynamic experiments for the past 25 years. Pulses of protons are imaged on a scintillator, and the light from these images is captured by fast gated cameras. The need for fast, bright scintillators has led to some compromises in image quality due to tiling the scintillators and backgrounds with totally internally reflected light. We show how large-grain scintillator screens, made using a thin plastic binder, solve these problems.
- Open Access
- 27 February 2023
- Published by Office of Scientific and Technical Information (OSTI)
The LANSCE experimental program: accelerator requirements
The U.S. Department of Energy's Office of Scientific and Technical Information
- 27 February 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessThe LANSCE experimental program: accelerator requirements
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 22 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Exploring Cesium and H-Beam Properties Internal to the Lansce H-Ion Source Using Resonant Absorption Spectroscopy and Cavity Ring Down Spectroscopy
The Los Alamos Neutron Science Center (LANSCE) H- ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H- ion source. The LANSCE H- Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, in particular to measure and diagnose dynamic H- and Cesium (Cs) properties. The Cs density probe is based on resonant absorption of a continuous wave diode laser tuned though the D2 line of cesium (~852 nm). The H- measurement relies on a much weaker photo-ionization process, and therefore relies on a cavity ring down spectroscopy measurement. The design, construction and commissioning of HLDS will be reviewed, the measurements and capabilities using the Cs laser diagnostic will be presented, and the status of the H- laser diagnostic will be discussed.
- 22 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Open AccessExploring Cesium and H-Beam Properties Internal to the Lansce H-Ion Source Using Resonant Absorption Spectroscopy and Cavity Ring Down Spectroscopy
The Los Alamos Neutron Science Center (LANSCE) H- ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H- ion source. The LANSCE H- Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, in particular to measure and diagnose dynamic H- and Cesium (Cs) properties. The Cs density probe is based on resonant absorption of a continuous wave diode laser tuned though the D2 line of cesium (~852 nm). The H- measurement relies on a much weaker photo-ionization process, and therefore relies on a cavity ring down spectroscopy measurement. The design, construction and commissioning of HLDS will be reviewed, the measurements and capabilities using the Cs laser diagnostic will be presented, and the status of the H- laser diagnostic will be discussed.
- 17 July 2020
- Published by Office of Scientific and Technical Information (OSTI)
(U) PRAD0697 & PRAD0698: Complex Loading of CeO₂ Powder
The U.S. Department of Energy's Office of Scientific and Technical Information
- 17 July 2020
- Published by Office of Scientific and Technical Information (OSTI)
(U) PRAD0697 & PRAD0698: Complex Loading of CeO₂ Powder
The U.S. Department of Energy's Office of Scientific and Technical Information
- 20 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
LANSCE Pulse
The U.S. Department of Energy's Office of Scientific and Technical Information
- 20 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
LANSCE Pulse
The U.S. Department of Energy's Office of Scientific and Technical Information
- 19 March 2019
- Published by Office of Scientific and Technical Information (OSTI)
LANL Bicycle Safety Committee - November 2018 Survey Results (Rev. 2)
The U.S. Department of Energy's Office of Scientific and Technical Information
- 19 March 2019
- Published by Office of Scientific and Technical Information (OSTI)
LANL Bicycle Safety Committee - November 2018 Survey Results (Rev. 2)
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Cylindrical Driven Shocks in Ceria
Shock compression of granular ceria (CeO 2 ) was studied in converging cylindrical geometry using LANL proton radiography, and driven by the Precision High Energy-Density Liner Implosion Experiment (PHELIX) magnetic implosion system. PHELIX delivered nearly 4 MA to a 1.25-mm thick liner-impactor to magnetically accelerate it to ~0.8-1.0 mm μs -1 . The impactor launched a shock in the cylindrical Al outer wall of the target assembly containing equiaxed, 0.63-μm-mean diameter ceria powder initially compacted to a static density of 3.95 or 4.03 g cm -3 . The cylindrically converging shock in the target was observed with a series of 21 proton-radiographic frames down the axis of the cylinder. Proton radiography was performed using a ×3 magnetic lens magnifier and a 7.5-mrad collimator. The proton radiographic views were transformed from transmission images to areal density images, for comparison to a model. Results indicate that significant energy was expended in compacting the porous CeO 2 , as the wave velocity markedly decreases during convergence, and a clear shock reflected from the axis was not observed. These observations are inconsistent with pre-shot modeling, and highlight the need for an improved understanding of the physics of compaction under non-ideal loading configurations.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Cylindrical Driven Shocks in Ceria
Shock compression of granular ceria (CeO 2 ) was studied in converging cylindrical geometry using LANL proton radiography, and driven by the Precision High Energy-Density Liner Implosion Experiment (PHELIX) magnetic implosion system. PHELIX delivered nearly 4 MA to a 1.25-mm thick liner-impactor to magnetically accelerate it to ~0.8-1.0 mm μs -1 . The impactor launched a shock in the cylindrical Al outer wall of the target assembly containing equiaxed, 0.63-μm-mean diameter ceria powder initially compacted to a static density of 3.95 or 4.03 g cm -3 . The cylindrically converging shock in the target was observed with a series of 21 proton-radiographic frames down the axis of the cylinder. Proton radiography was performed using a ×3 magnetic lens magnifier and a 7.5-mrad collimator. The proton radiographic views were transformed from transmission images to areal density images, for comparison to a model. Results indicate that significant energy was expended in compacting the porous CeO 2 , as the wave velocity markedly decreases during convergence, and a clear shock reflected from the axis was not observed. These observations are inconsistent with pre-shot modeling, and highlight the need for an improved understanding of the physics of compaction under non-ideal loading configurations.