Julie A. Durcan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Julie A. Durcan has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Sam Woor
Department of Earth, Ocean and Atmospheric Sciences, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
9 shared publications Maria Schaarschmidt
Department of Geoscience, University of the Fraser Valley, Abbottsford, BC V27 7M7, Canada
7 shared publicationsOlav B. Lian
Department of Geoscience, University of the Fraser Valley, Abbottsford, BC V27 7M7, Canada
7 shared publicationsMitch K. D'Arcy
Department of Earth, Ocean and Atmospheric Sciences, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
4 shared publicationsAsh Parton
3 shared publications- David S. G. Thomas
School of Geography and the Environment University of Oxford Oxford UK
3 shared publications
Latest Publications
- Open Access
- 17 September 2026
- Published by Elsevier in Quaternary Geochronology
- Vol. 96
Dose rate and age calculator (DRAC v1.3): An update
- 17 September 2026
- Published by Elsevier in Quaternary Geochronology
- Vol. 96
Open AccessDose rate and age calculator (DRAC v1.3): An update
- Open Access
- 7 January 2026
- Published by Copernicus GmbH in Geochronology
- Vol. 8 (1) , 1-18
Rapid dose rate estimation for trapped charge dating using pXRF measurements of potassium concentration
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used to calculate dose rates are typically time consuming and expensive and are impractical for such “range-finder” applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates, uranium (U) and thorium (Th), fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to estimate total environmental dose rates. A large, global dataset of 1473 radionuclide samples is used to generate a set of regression relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent, high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using these equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence-dating scenarios (such as 180-250 µm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The regression equations can predict external beta dose rates to a good degree of accuracy based on K content alone, whilst external gamma dose rates are predicted less accurately, and external alpha dose rates are predicted the least accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 95 % of our results lying within uncertainties of ±10 % of unity for scenarios where the alpha dose rate contribution is assumed to be negligible. Whilst alpha dose rate contributions are predicted the least accurately, scenarios including an alpha component result in at least 80 % of predictions lying within uncertainties of ±10 % of unity. The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter. This study serves as a proof of concept that pXRF measurements, along with a set of regression equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- 7 January 2026
- Published by Copernicus GmbH in Geochronology
- Vol. 8 (1) , 1-18
Open AccessRapid dose rate estimation for trapped charge dating using pXRF measurements of potassium concentration
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used to calculate dose rates are typically time consuming and expensive and are impractical for such “range-finder” applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates, uranium (U) and thorium (Th), fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to estimate total environmental dose rates. A large, global dataset of 1473 radionuclide samples is used to generate a set of regression relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent, high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using these equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence-dating scenarios (such as 180-250 µm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The regression equations can predict external beta dose rates to a good degree of accuracy based on K content alone, whilst external gamma dose rates are predicted less accurately, and external alpha dose rates are predicted the least accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 95 % of our results lying within uncertainties of ±10 % of unity for scenarios where the alpha dose rate contribution is assumed to be negligible. Whilst alpha dose rate contributions are predicted the least accurately, scenarios including an alpha component result in at least 80 % of predictions lying within uncertainties of ±10 % of unity. The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter. This study serves as a proof of concept that pXRF measurements, along with a set of regression equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- Open Access
- 5 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-29
Reply on RC3
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- 5 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-29
Open AccessReply on RC3
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- Open Access
- 5 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-29
Reply on RC1
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- 5 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-29
Open AccessReply on RC1
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- Open Access
- 5 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-29
Reply on RC2
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- 5 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-29
Open AccessReply on RC2
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- Open Access
- 16 February 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-29
Comment on egusphere-2025-55
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- 16 February 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-29
Open AccessComment on egusphere-2025-55
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- Open Access
- 28 January 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-29
Rapid dose rate estimation for trapped charge dating using pXRF measurements of potassium concentration
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- 28 January 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-29
Open AccessRapid dose rate estimation for trapped charge dating using pXRF measurements of potassium concentration
Quantifying environmental radiation dose rates is an essential step in age calculation using trapped charge dating methods. A means of rapid dose rate estimation would therefore be useful for a variety of reasons, especially in contexts where rapid equivalent dose estimates are available. For instance, for informing sampling strategy, providing initial age estimates, or supporting portable luminescence studies. However, high-precision methods often used for calculating dose rates are typically time consuming and expensive and are impractical for such ‘range-finder’ applications. Portable X-ray fluorescence (pXRF) offers a rapid means of measuring the Potassium (K) concentration of sediment, although the other radionuclides typically used to calculate dose rates (Uranium (U) and Thorium (Th)) fall beneath its detection limits at the quantities at which they are usually present in sediments. In this study, we investigate whether pXRF measurements of K concentration alone can be used to accurately estimate total environmental dose rates. A large, global training dataset of 1473 radionuclide samples is used to generate a set of linear relationships between (1) K concentration and external beta dose rate; (2) external beta and gamma dose rates; and (3) external gamma and alpha dose rates. We test the utility of these relationships by measuring the K contents of 67 sediment samples with independent high-precision radionuclide data from a variety of contexts using pXRF. The resulting K concentrations are then converted to external dose rate estimates using the training equations. A simplified set of attenuation parameters are used to correct infinite matrix dose rate estimates, and these are combined with cosmic ray and internal contributions to rapidly calculate total environmental dose rates for a range of theoretical, common luminescence dating scenarios (such as 180–250 μm quartz that has undergone etching). Results show that pXRF can accurately measure K concentrations in a laboratory setting. The training equations can predict external beta dose rates accurately based on K content alone, whilst external alpha dose rates are predicted less accurately. In combination, total estimated dose rates show good agreement with their counterparts calculated from high-precision methods, with 68–98 % of our results lying within ±20 % of unity depending on the scenario. We report better agreement for scenarios where alpha contributions are assumed to be negligible (e.g., in the case of etched, coarse-grained quartz or potassium feldspar). The use of simplified attenuation factors to correct estimated infinite matrix dose rates does not contribute significantly to resulting scatter, with uncertainties mostly resulting from the training equations. This study serves as a proof of concept that pXRF measurements, along with a set of linear equations and a simplified correction procedure, can be used to rapidly calculate range-finder environmental dose rates.
- Open Access
- 28 January 2025
- Published by Copernicus GmbH
Supplementary material to "Rapid dose rate estimation for trapped charge dating using pXRF measurements of potassium concentration"
- 28 January 2025
- Published by Copernicus GmbH
Open AccessSupplementary material to "Rapid dose rate estimation for trapped charge dating using pXRF measurements of potassium concentration"
- Open Access
- 26 July 2024
- Published by Elsevier in Radiation Measurements
- Vol. 177
Further investigation of spatially resolved single grain quartz OSL and TL signals
- 26 July 2024
- Published by Elsevier in Radiation Measurements
- Vol. 177
Open AccessFurther investigation of spatially resolved single grain quartz OSL and TL signals
- Open Access
- 29 May 2024
- Published by Springer Nature in Nature Geoscience
- Vol. 17 (7) , 645-653
Shift away from Nile incision at Luxor ~4,000 years ago impacted ancient Egyptian landscapes
Although the Nile is one of the largest rivers in the world and played a central role in ancient Egyptian life, little is known about its response to climatic change during the Holocene. Here we present a framework for the evolution of the Egyptian Nile, demonstrating how climatic and environmental changes have shaped the landscape of the Egyptian Nile Valley over the past 11,500 years, including the civilization of ancient Egypt (~5,000 to 2,000 years ago). Using data from over 80 sediment cores drilled in a transect spanning the Nile Valley near Luxor, pinned in time by 48 optically stimulated luminescence ages, we reconstruct the dynamics of the Nile River during the Holocene in the vicinity of UNESCO World Heritage sites such as Karnak and Luxor temples. According to our reconstruction, valley incision occurred from the start of the record until approximately 4,000 years ago and then rapidly shifted to massive floodplain aggradation. We argue that this relatively abrupt change in the riverine landscape near Luxor from the Middle to Late Holocene was linked to a shift towards a drier regional hydroclimate around this time. Such a dramatic change in river sediment dynamics could have had local agro-economic consequences.
- 29 May 2024
- Published by Springer Nature in Nature Geoscience
- Vol. 17 (7) , 645-653
Open AccessShift away from Nile incision at Luxor ~4,000 years ago impacted ancient Egyptian landscapes
Although the Nile is one of the largest rivers in the world and played a central role in ancient Egyptian life, little is known about its response to climatic change during the Holocene. Here we present a framework for the evolution of the Egyptian Nile, demonstrating how climatic and environmental changes have shaped the landscape of the Egyptian Nile Valley over the past 11,500 years, including the civilization of ancient Egypt (~5,000 to 2,000 years ago). Using data from over 80 sediment cores drilled in a transect spanning the Nile Valley near Luxor, pinned in time by 48 optically stimulated luminescence ages, we reconstruct the dynamics of the Nile River during the Holocene in the vicinity of UNESCO World Heritage sites such as Karnak and Luxor temples. According to our reconstruction, valley incision occurred from the start of the record until approximately 4,000 years ago and then rapidly shifted to massive floodplain aggradation. We argue that this relatively abrupt change in the riverine landscape near Luxor from the Middle to Late Holocene was linked to a shift towards a drier regional hydroclimate around this time. Such a dramatic change in river sediment dynamics could have had local agro-economic consequences.