Bohyun Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bohyun Kim has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Young Ahn Yoon
Department of Laboratory Medicine, Soonchunhyang University Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan, Korea
5 shared publicationsYoung-Jin Choi
Department of Laboratory Medicine, Soonchunhyang University Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan, Korea
5 shared publications- Seongsoo Jang
Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
4 shared publications M.D.
3 shared publications- Mi-Na Kim
Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine
3 shared publications - Nam Hun Heo
Clinical Trial Center, Soonchunhyang University Cheonan Hospital, 31 Suncheonhyang 6-gil, Dongnam-gu, Cheonan 31151, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
- Vol. 46 (6) , 647-649
Beyond the Favorable-Risk Label: Sequential Measurable Residual Disease and KIT Variant Status in Pediatric Core-Binding Factor Acute Myeloid Leukemia
Bohyun Kim, M.D., Ph.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2026.0601
- 12 October 2026
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
- Vol. 46 (6) , 647-649
Open AccessBeyond the Favorable-Risk Label: Sequential Measurable Residual Disease and KIT Variant Status in Pediatric Core-Binding Factor Acute Myeloid Leukemia
Bohyun Kim, M.D., Ph.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2026.0601
- Open Access
- 1 October 2026
- Published by Laboratory Medicine Online in Laboratory Medicine Online
- Vol. 16 (4) , 279-286
Automation of the Hemostasis Laboratory: Implementation and Future Directions
Bohyun Kim, M.D.. Lab Med Online 2026;16:279-86. https://doi.org/10.47429/lmo.2026.16.4.279
- 1 October 2026
- Published by Laboratory Medicine Online in Laboratory Medicine Online
- Vol. 16 (4) , 279-286
Open AccessAutomation of the Hemostasis Laboratory: Implementation and Future Directions
Bohyun Kim, M.D.. Lab Med Online 2026;16:279-86. https://doi.org/10.47429/lmo.2026.16.4.279
- Open Access
- 19 August 2026
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
Digital Morphology Analyzer-Based White Blood Cell Differentials: Practical Considerations for External Quality Assessment
Hongkyung Kim, M.D., Ph.D., Oh Joo Kweon, M.D., Ph.D., Sumi Yoon, M.D., Ph.D., Yong Kwan Lim, M.D., Ph.D., and Bohyun Kim, M.D., Ph.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2026.0097
- 19 August 2026
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
Open AccessDigital Morphology Analyzer-Based White Blood Cell Differentials: Practical Considerations for External Quality Assessment
Hongkyung Kim, M.D., Ph.D., Oh Joo Kweon, M.D., Ph.D., Sumi Yoon, M.D., Ph.D., Yong Kwan Lim, M.D., Ph.D., and Bohyun Kim, M.D., Ph.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2026.0097
- Open Access
Prospective Multimodal Assessment of Radiation-Induced Subclinical Cardiac Changes in Patients with Left Breast Cancer Using Hematologic Biomarkers, Echocardiography, and 18F-FDG PET/CT: A Pilot Study
Background/Objectives: This prospective study aimed to investigate asymptomatic microscopic changes in the myocardium following postoperative radiation therapy (RT) in patients with left breast cancer using multi-medical assessment techniques. Methods: This study included 16 left-sided breast cancer patients who received postoperative RT between January 2021 and December 2022 at our institution. Cardiac examinations were performed before RT and at 1, 12, 24, and 48 weeks after RT. We conducted comparative analyses between pre-RT and various post-RT time points, exploring correlations between changes in hematologic biomarkers, global longitudinal strain (GLS), and myocardial metabolism. Results: Inflammatory biomarkers such as the neutrophil–lymphocyte, platelet–lymphocyte, and lymphocyte–monocyte ratios changed between the pre- and post-RT periods but returned to normal levels after several months. However, troponin T and soluble suppression of tumorigenicity 2 showed sustained changes during the 1-year follow-up period. Among echocardiographic parameters, GLS_LAX showed a significant difference between pre-RT and post-RT assessments. Additionally, irradiated and non-irradiated myocardial metabolic ratios on 18F-fluorodeoxyglucose positron emission tomography/computed tomography differed between pre-RT and post-RT and remained altered up to one year after treatment. Conclusions: These findings suggest that subclinical myocardial changes may persist following RT, although the clinical significance of subclinical myocardial changes remains uncertain and warrants further investigation.
Open AccessProspective Multimodal Assessment of Radiation-Induced Subclinical Cardiac Changes in Patients with Left Breast Cancer Using Hematologic Biomarkers, Echocardiography, and 18F-FDG PET/CT: A Pilot Study
Background/Objectives: This prospective study aimed to investigate asymptomatic microscopic changes in the myocardium following postoperative radiation therapy (RT) in patients with left breast cancer using multi-medical assessment techniques. Methods: This study included 16 left-sided breast cancer patients who received postoperative RT between January 2021 and December 2022 at our institution. Cardiac examinations were performed before RT and at 1, 12, 24, and 48 weeks after RT. We conducted comparative analyses between pre-RT and various post-RT time points, exploring correlations between changes in hematologic biomarkers, global longitudinal strain (GLS), and myocardial metabolism. Results: Inflammatory biomarkers such as the neutrophil–lymphocyte, platelet–lymphocyte, and lymphocyte–monocyte ratios changed between the pre- and post-RT periods but returned to normal levels after several months. However, troponin T and soluble suppression of tumorigenicity 2 showed sustained changes during the 1-year follow-up period. Among echocardiographic parameters, GLS_LAX showed a significant difference between pre-RT and post-RT assessments. Additionally, irradiated and non-irradiated myocardial metabolic ratios on 18F-fluorodeoxyglucose positron emission tomography/computed tomography differed between pre-RT and post-RT and remained altered up to one year after treatment. Conclusions: These findings suggest that subclinical myocardial changes may persist following RT, although the clinical significance of subclinical myocardial changes remains uncertain and warrants further investigation.
- Open Access
- 8 September 2025
- Published by Springer Nature in Blood Research
- Vol. 60 (1) , 1-2
Does the current apixaban dosing strategy adequately fit and ensure safety in Korean patients with atrial fibrillation?
- 8 September 2025
- Published by Springer Nature in Blood Research
- Vol. 60 (1) , 1-2
Open AccessDoes the current apixaban dosing strategy adequately fit and ensure safety in Korean patients with atrial fibrillation?
- Open Access
- 23 January 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (7) , 1409-1418
Performance of the automated digital cell image analyzer UIMD PBIA in white blood cell classification: a comparative study with sysmex DI-60
Objectives: This study aimed to evaluate the performance of PBIA (UIMD, Seoul, Republic of Korea), an automated digital morphology analyzer using deep learning, for white blood cell (WBC) classification in peripheral blood smears and compare it with the widely used DI-60 (Sysmex, Kobe, Japan). Methods: A total of 461 slides were analyzed using PBIA and DI-60. For each instrument, pre-classification performance was evaluated on the basis of post-classification results verified by users. Pre- and post-classification results were compared with manual WBC differentials, and the ability to identify abnormal cells was assessed. Results: The pre-classification performance of PBIA was better than that of DI-60 for most cell classes. PBIA had an accuracy of 90.0 % and Cohen’s kappa of 0.934, higher than DI-60 (45.5 % accuracy and 0.629 kappa) across all cell classes. The pre-classification performance of both instruments decreased when abnormal cells were observed in manual counts, but PBIA still performed better. PBIA also appeared to show better correlation with manual WBC differential counts, particularly in pre-classification (Pearson’s correlation coefficient: 0.696–0.944 vs. 0.230–0.882 for neutrophils, lymphocytes, monocytes, eosinophils, basophils, and blasts), although the mean differences varied by cell class. For abnormal cells identified in manual counts, PBIA exhibited more false positives for blasts (30.5 vs. 2.3 %), while DI-60 had a higher rate of false negatives (42.1 vs. 6.1 %). Both instruments exhibited high false negative rates for atypical lymphocytes. Conclusions: PBIA demonstrated better performance than DI-60, highlighting its clinical utility. Further multicenter studies are required for full validation.
- 23 January 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (7) , 1409-1418
Open AccessPerformance of the automated digital cell image analyzer UIMD PBIA in white blood cell classification: a comparative study with sysmex DI-60
Objectives: This study aimed to evaluate the performance of PBIA (UIMD, Seoul, Republic of Korea), an automated digital morphology analyzer using deep learning, for white blood cell (WBC) classification in peripheral blood smears and compare it with the widely used DI-60 (Sysmex, Kobe, Japan). Methods: A total of 461 slides were analyzed using PBIA and DI-60. For each instrument, pre-classification performance was evaluated on the basis of post-classification results verified by users. Pre- and post-classification results were compared with manual WBC differentials, and the ability to identify abnormal cells was assessed. Results: The pre-classification performance of PBIA was better than that of DI-60 for most cell classes. PBIA had an accuracy of 90.0 % and Cohen’s kappa of 0.934, higher than DI-60 (45.5 % accuracy and 0.629 kappa) across all cell classes. The pre-classification performance of both instruments decreased when abnormal cells were observed in manual counts, but PBIA still performed better. PBIA also appeared to show better correlation with manual WBC differential counts, particularly in pre-classification (Pearson’s correlation coefficient: 0.696–0.944 vs. 0.230–0.882 for neutrophils, lymphocytes, monocytes, eosinophils, basophils, and blasts), although the mean differences varied by cell class. For abnormal cells identified in manual counts, PBIA exhibited more false positives for blasts (30.5 vs. 2.3 %), while DI-60 had a higher rate of false negatives (42.1 vs. 6.1 %). Both instruments exhibited high false negative rates for atypical lymphocytes. Conclusions: PBIA demonstrated better performance than DI-60, highlighting its clinical utility. Further multicenter studies are required for full validation.
- Open Access
- 21 October 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 47 (1) , 79-86
Definition of Significant Platelet Clumping: Should We Review All Samples With a Platelet Clumping Flag From Automated Hematology Analyzer?
Objectives: This study aimed to determine a definition for significant platelet clumping (PC) and evaluate the performance of the Sysmex XN instrument for detecting platelet clumps.Methods: For part 1, 372 specimens with a ‘PLT_clump?’ flag in XN‐9000 were classified into five groups according to the average number of PCs. We compared the initial platelet count (measured by XN‐9000 using impedance method) and corrected platelet count (counted optically or re‐analyzed by XN‐9000 using vortexed or re‐collected sample) of each group. For part 2, 1000 specimens with a PC flag divided into three subgroups {group N (PC = 0), Y (PC ≥ 1), and Z (microscopic fibrin clot)} and additional two groups {group S (PC(+) specimens without any flag and with flags of other categories) and group NC (negative control)} were collected. Positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity of PC detection of XN‐9000 were obtained and the platelet counts and four indices (PDW, MPV, P_LCR, and PCT) of groups NC, N, Y, Z, and S were compared to detect PC more precisely.Results: In part 1, all groups showed significant difference between the initial and corrected platelet counts. In part 2, PPV, NPV, prevalence, sensitivity, and specificity were 41.5%, 56.5%, 43.4%, 2.18%, and 98.3%, respectively. The platelet counts and four indices showed statistical differences for detecting PCs, and especially PDW and P_LCR were significantly smaller in group Z than group N or Y.Conclusions: We suggest the definition of significant PC by the presence of at least three platelets. In addition, utilizing platelet‐related indices should be developed to improve the efficiency of the PC detection.
- 21 October 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 47 (1) , 79-86
Open AccessDefinition of Significant Platelet Clumping: Should We Review All Samples With a Platelet Clumping Flag From Automated Hematology Analyzer?
Objectives: This study aimed to determine a definition for significant platelet clumping (PC) and evaluate the performance of the Sysmex XN instrument for detecting platelet clumps.Methods: For part 1, 372 specimens with a ‘PLT_clump?’ flag in XN‐9000 were classified into five groups according to the average number of PCs. We compared the initial platelet count (measured by XN‐9000 using impedance method) and corrected platelet count (counted optically or re‐analyzed by XN‐9000 using vortexed or re‐collected sample) of each group. For part 2, 1000 specimens with a PC flag divided into three subgroups {group N (PC = 0), Y (PC ≥ 1), and Z (microscopic fibrin clot)} and additional two groups {group S (PC(+) specimens without any flag and with flags of other categories) and group NC (negative control)} were collected. Positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity of PC detection of XN‐9000 were obtained and the platelet counts and four indices (PDW, MPV, P_LCR, and PCT) of groups NC, N, Y, Z, and S were compared to detect PC more precisely.Results: In part 1, all groups showed significant difference between the initial and corrected platelet counts. In part 2, PPV, NPV, prevalence, sensitivity, and specificity were 41.5%, 56.5%, 43.4%, 2.18%, and 98.3%, respectively. The platelet counts and four indices showed statistical differences for detecting PCs, and especially PDW and P_LCR were significantly smaller in group Z than group N or Y.Conclusions: We suggest the definition of significant PC by the presence of at least three platelets. In addition, utilizing platelet‐related indices should be developed to improve the efficiency of the PC detection.
- Open Access
- 19 April 2024
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
- Vol. 44 (6) , 572-575
Reliability of the DI-60 Digital Image Analyzer for Detecting Platelet Clumping and Obtaining Accurate Platelet Counts
Suhyeon Woo, M.D., Bohyun Kim, M.D., Nam Hun Heo, M.S., Min-Sun Kim, M.D., Young Ahn Yoon, M.D., and Young-Jin Choi, M.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2024.0003
- 19 April 2024
- Published by Annals of Laboratory Medicine in Annals of Laboratory Medicine
- Vol. 44 (6) , 572-575
Open AccessReliability of the DI-60 Digital Image Analyzer for Detecting Platelet Clumping and Obtaining Accurate Platelet Counts
Suhyeon Woo, M.D., Bohyun Kim, M.D., Nam Hun Heo, M.S., Min-Sun Kim, M.D., Young Ahn Yoon, M.D., and Young-Jin Choi, M.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2024.0003
- Open Access
- 25 December 2023
- Published by Wiley in Alzheimer's & Dementia
- Vol. 19 (S19)
Stress and hypertension self‐care pilot study for Black women caregivers of people living with Alzheimer’s disease and related dementias
Background: This National Institutes on Aging study protocol (R21AG077069‐01 NIA) will test a behavioral intervention, Mindfulness in Motion plus the Dietary Approaches to Stop Hypertension (MIM DASH), to promote hypertension self‐care in African American women caregivers of people living with Alzheimer’s disease and related dementias.Method: Twenty‐eight participants will be randomized to MIM DASH or Alzheimer’s Association Caregiver Training groups, delivered 8 weekly, 1‐hour group sessions via telehealth (video and telephone access). Data are collected at baseline, 3 and 9 months that include a) psychosocial surveys and Healthy Eating Index—DASH score and b) blood pressure, hair cortisol, and an objective stress reactivity/stress resilience battery.Result: MIM DASH will be feasible and acceptable, and will decrease caregivers’ stress and improve quality of life; higher stress resilience will enhance the relationship between MIM DASH and intervention adoption while higher stress reactivity will diminish this relationship.Conclusion: Substantive contributions to the science of behavior change, design of self‐care interventions, and the adoption of healthy behaviors will be achieved. Results will inform infrastructure for a larger trial to reduce health disparities among African Americans.
- 25 December 2023
- Published by Wiley in Alzheimer's & Dementia
- Vol. 19 (S19)
Open AccessStress and hypertension self‐care pilot study for Black women caregivers of people living with Alzheimer’s disease and related dementias
Background: This National Institutes on Aging study protocol (R21AG077069‐01 NIA) will test a behavioral intervention, Mindfulness in Motion plus the Dietary Approaches to Stop Hypertension (MIM DASH), to promote hypertension self‐care in African American women caregivers of people living with Alzheimer’s disease and related dementias.Method: Twenty‐eight participants will be randomized to MIM DASH or Alzheimer’s Association Caregiver Training groups, delivered 8 weekly, 1‐hour group sessions via telehealth (video and telephone access). Data are collected at baseline, 3 and 9 months that include a) psychosocial surveys and Healthy Eating Index—DASH score and b) blood pressure, hair cortisol, and an objective stress reactivity/stress resilience battery.Result: MIM DASH will be feasible and acceptable, and will decrease caregivers’ stress and improve quality of life; higher stress resilience will enhance the relationship between MIM DASH and intervention adoption while higher stress reactivity will diminish this relationship.Conclusion: Substantive contributions to the science of behavior change, design of self‐care interventions, and the adoption of healthy behaviors will be achieved. Results will inform infrastructure for a larger trial to reduce health disparities among African Americans.
- Open Access
- 1 January 2023
- Published by Laboratory Medicine Online in Laboratory Medicine Online
- Vol. 13 (1) , 1-6
Bleeding time: Remained or Retired or Removed?
Bohyun Kim, M.D.. Lab Med Online 2023;13:1-6. https://doi.org/10.47429/lmo.2023.13.1.1
- 1 January 2023
- Published by Laboratory Medicine Online in Laboratory Medicine Online
- Vol. 13 (1) , 1-6
Open AccessBleeding time: Remained or Retired or Removed?
Bohyun Kim, M.D.. Lab Med Online 2023;13:1-6. https://doi.org/10.47429/lmo.2023.13.1.1