DHDenise Tessariol Hachul

Denise Tessariol Hachul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Denise Tessariol Hachul has a total of 369 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diretriz Brasileira de Cardiogeriatria – 2026

    by Izo Helber, José Carlos da Costa Zanon, José Maria Peixoto, Adriano Caixeta, Amit Nussbacher, Dinaldo Cavalcanti de Oliveira, Elizabete Viana de Freitas, Fatima Dumas Cintra, Jessica Myrian de Amorim Garcia, Roberto Dischinger Miranda, et al.

    Sumário […] Diretriz Brasileira de Cardiogeriatria – 2026 Sumário […] Diretriz Brasileira de Cardiogeriatria – 2026

  • Reply to the Letter to the Editor on "Proposal for a tooth extraction protocol for patients taking direct oral anticoagulants: A clinical trial"

    by Elaine Massumi Higashi, Itamara Lucia Itagiba Neves, Francisco Carlos da Costa Darrieux, Marcela Alves dos Santos Paul, Gustavo Luiz Alkmin Paiva, Vitor Takao Omori, Ricardo Simões Neves, Maurício Ibraim Scanavacca, Denise Tessariol Hachul


  • Open Access

    Dynamic Expression of the Type 1 Brugada ECG Pattern During Tilt Table Testing Using Continuous High Precordial Lead Positioning

    by Eduardo Nolla Silva Pereira, Luciana Sacilotto, Tan Chen Wu, Gabrielle D’Arezzo Pessente, Nemer Luis Pichara, Denise Tessariol Hachul, Mauricio Ibrahim Scanavacca, Francisco Carlos da Costa Darrieux

    Background/Objectives: The Type 1 Brugada ECG pattern (BrP1) fluctuates according to autonomic influences. Tilt table testing induces changes in both sympathetic and parasympathetic activity. It may provide insights into the dynamic behavior of BrP1 when combined with high-precordial lead placement. However, the clinical significance of BrP1 variability during tilt table testing remains poorly defined. Methods: This cross-sectional study evaluated patients with confirmed Brugada syndrome who underwent tilt table testing with continuous ECG monitoring using high-precordial leads. BrP1 behavior was assessed during predefined phases: baseline supine position, orthostatic tilt, nitrate administration, recovery, and syncope when present. Subsequently, clinical characteristics and test results were analyzed for associations with dynamic BrP1 expression. Results: Forty-four patients (mean age 49 years; 72.7% men) were included. Thirty-five patients (79.5%) had a spontaneous type 1 Brugada ECG pattern, and nine (20.5%) had a drug-induced pattern. BrP1 expression varied dynamically/heterogeneously during tilt table testing. No patient without BrP1 at admission developed the pattern during tilt phases. Thirty patients (68.1%) remained negative throughout testing, while five lost the pattern during the test (11.3%), and nine (20.4%) showed persistent BrP1 in all phases. Persistent BrP1 was associated with more frequent presumed arrhythmic syncope and implantable cardioverter defibrillator implantation (p < 0.05). No atrial or ventricular arrhythmias or device-related complications occurred. Conclusions: Tilt table testing with high precordial leads does not unmask BrP1 and should not be used as a diagnostic provocation tool. However, it allows for the characterization of autonomic modulation and phenotypic stability in Brugada syndrome. Any potential prognostic relevance of dynamic BrP1 behavior remains speculative and requires evaluation in adequately powered prospective studies.

  • Proposal for a tooth extraction protocol for patients taking direct oral anticoagulants: a clinical trial

    by Elaine Massumi Higashi, Itamara Lucia Itagiba Neves, Francisco Carlos da Costa Darrieux, Marcela Alves dos Santos Paul, Gustavo Luiz Alkmin Paiva, Vitor Takao Omori, Ricardo Simões Neves, Maurício Ibraim Scanavacca, Denise Tessariol Hachul


  • Open Access

    Brazilian Atrial Fibrillation Guidelines – 2025

    by Fatima Dumas Cintra, Cristiano Faria Pisani, André Gustavo da Silva Rezende, Benhur Davi Henz, Luciana Vidal Armaganijan, Maurício Pimentel, Renato D. Lopes, Thais Aguiar Do Nascimento, Adalberto Menezes Lorga Filho, Afonso Luiz Tavares de Albuquerque, et al.


  • Diretriz Brasileira de Fibrilação Atrial – 2025

    by Fatima Dumas Cintra, Cristiano Faria Pisani, André Gustavo da Silva Rezende, Benhur Davi Henz, Luciana Vidal Armaganijan, Maurício Pimentel, Renato D. Lopes, Thais Aguiar Do Nascimento, Adalberto Menezes Lorga, Afonso Luiz Tavares de Albuquerque, et al.


  • Open Access

    Esophageal Protection Strategies for Ablation of Atrial Fibrillation: Comparative Results of Consecutive Endoscopic Evaluation

    by Alberto Pereira Ferraz, Cristiano Faria Pisani, Esteban Wisnivesky Rocca Rivarola, Tan Chen Wu, Francisco Carlos da Costa Darrieux, Rafael Alvarenga Scanavacca, Muhieddine Omar Chokr, Carina Abigail Hardy, Sissy Lara de Melo, Denise Tessariol Hachul, et al.

    Background Atrial-esophageal fistula following AF ablation remains a concern. There is no standardized approach to minimize its risk and morbidity. Objective To present the seven-year experience of a systematic endoscopic surveillance of esophageal injury after AF catheter ablation. Methods This is a retrospective single center registry of systematic endoscopic evaluation after AF ablation in consecutive procedures performed from 2016 to 2022. A p-value of <0.05 was considered statistically significant. Results 823 AF ablation with controlled esophagogastroduodenoscopy (EGD) were analyzed. Most patients (n=588, 71.4%) were male, 575 (69.9%) had paroxysmal AF. Esophageal temperature monitoring was performed using a single sensor in 310 patients (40.3%) and a multi–sensor probe in 306 (39.8%). Lesions were presented in 217 EGD (26.5%): hematoma-ecchymosis in 27 (3.3%), erythema in 14 (1.7%), erosion in 78 (9.5%) and ulcer in 67 (8.2%) patients. No esophageal protective strategy was associated with more ulcers, except the use of 8mm tip-catheter (14.7% of ulcers with 8mm tip catheter vs 6.7% with other catheters, p = 0.001). Thermal lesions were early detected and treated. Most lesions were considered healed at endoscopy, but one patient who underwent pulmonary vein isolation with an 8m tip catheter had esophageal fistula, treated successfully with endoscopic metal clip and endoloop technique. Conclusion The incidence of esophageal lesions at routine EGD following AF ablation is high, although in most of the cases they heal spontaneously. Patients who underwent ablation with the 8mm tip catheter had more severe thermal lesions. Early esophagus endoscopy may help the diagnosis of early-stage lesions and the prevention of fistula formation after AF ablation.


  • Open Access

    Estratégias de Proteção Esofágica para Ablação de Fibrilação Atrial: Resultados Comparativos de Avaliações Endoscópicas Consecutivas

    by Alberto Pereira Ferraz, Cristiano Faria Pisani, Esteban Wisnivesky Rocca Rivarola, Tan Chen Wu, Francisco Carlos da Costa Darrieux, Rafael Alvarenga Scanavacca, Muhieddine Omar Chokr, Carina Abigail Hardy, Sissy Lara de Melo, Denise Tessariol Hachul, et al.

    Resumo Fundamento A ocorrência de fístula atrioesofágica após o procedimento ode ablação de fibrilação atrial (FA) continua uma preocupação. Não existe uma abordagem padronizada para minimizar seus riscos e mortalidade. Objetivos Apresentar a experiência de sete anos de um monitoramento endoscópico sistemático de lesão esofágica após a ablação de FA por cateter. Métodos Estudo unicêntrico retrospectivo de avaliação endoscópica sistemática após ablação e FA em procedimentos consecutivos realizados entre 2016 e 2022. Um valor de p < 0.05 foi considerado estatisticamente significativo. Resultados Foram analisados 823 procedimentos de ablação de FA com Esofagogastroduodenoscopia (EGD) de controle. A maioria (n=588; 71,4%) dos pacientes submetidos ao procedimento era do sexo masculino, 575 (69,9%) apresentaram FA paroxística. Monitoramento da temperatura esofágica foi realizada usando um sensor único em 310 pacientes (40,3%) e uma sonda multissensor em 306 (39,8%) pacientes. As lesões estavam presentes em 217 EGD (26,5%): hematoma-equimose em 27 (3,3%), eritema em 14 (1,7%), erosão em 78 (9,5%) e úlcera em 67 (8,2%) pacientes. Nenhuma estratégia de proteção do esôfago foi associada à maior ocorrência de úlceras, com exceção do uso de cateter de ponta de 8mm (14,7% de úlceras com cateter de ponta de 8mm vs. 6,7% com outros cateteres, p = 0,001). Lesões térmicas foram detectadas precocemente e tratadas. A maioria das lesões foi considerada curada na endoscopia, mas um paciente que foi submetido ao isolamento da veia pulmonar com um cateter de ponta de 8mm apresentou fístula esofágica, que foi tratada com sucesso com clipe metálico endoscópico e técnica endoloop. Conclusão A incidência de lesões esofágicas é alta na EGD de rotina realizada após a ablação de FA, embora, na maioria dos casos, sua cura ocorra espontaneamente. Pacientes que se submeteram à ablação com o cateter de ponta de 8mm apresentaram lesões térmicas mais graves. Endoscopia esofágica precoce pode ajudar no diagnóstico de lesões em fases iniciais e a prevenção de fístulas após a ablação de FA.


  • Unicentric Brazilian registry of cardiac sympathetic denervation for control of ventricular arrhythmias

    by Rodrigo M. Kulchetscki, Paulo Henrique Peitl Gregório, Gabrielle D.’aRezzo Pessente, Cristiano F. Pisani, Muhieddine O. Chokr, Carina A. Hardy, Luciana Sacilotto, Francisco Carlos da Costa Darrieux, Denise Hachul, Mauricio I. Scanavacca, et al.

  • Open Access

    Monitoramento da Temperatura Esofágica durante a Ablação de Fibrilação Atrial: Um Estudo Randomizado

    by Daniel Moreira Costa Moura, Renner Augusto Raposo Pereira, Cristiano Faria Pisani, Tan Chen Wu, Muhieddine Omar Chokr, Carina Abigail Hardy, Sissy Lara de Melo, Francisco Carlos da Costa Darrieux, Denise Tessariol Hachul, Mauricio Ibrahim Scanavacca

    Resumo Fundamento O isolamento das veias pulmonares (IVP) para a ablação da fibrilação atrial (FA) apresenta risco de lesão térmica esofágica (LTE), que pode levar a complicações graves. Objetivo Avaliar três estratégias de monitoramento da temperatura esofágica luminal (TEL) e analisar sua eficácia na redução da incidência de LTE. Métodos Pacientes com FA foram randomizados em três grupos de IVP, conforme a estratégia de monitoramento da temperatura: sem monitoramento de TEL (Grupo 1), monitoramento de TEL com termômetro unipolar (Grupo 2) e monitoramento de TEL com termômetro multipolar (Grupo 3). No Grupo 1, a ablação da FA foi realizada com potência fixa de 20 W na parede posterior do átrio esquerdo. Nos Grupos 2 e 3, a potência da ablação foi ajustada com base nas medições da TEL, utilizando como limite a temperatura de 37,5 °C. Cada grupo incluiu 20 pacientes. Considerou-se estatisticamente significativo um valor de p bilateral <0,05. O estudo foi registrado no ClinicalTrials.gov (#NCT03645070) e na International Clinical Trials Registry Platform (#RBR-2yvgyf). Resultados Todos os pacientes foram submetidos a IVP e à esofagogastroduodenoscopia. Nenhum caso de LTE foi observado em pacientes monitorados com o termômetro multipolar. Em contraste, cinco pacientes sem monitoramento de TEL e seis pacientes monitorados com o termômetro unipolar desenvolveram LTE (p=0,006). Temperaturas mais elevadas foram registradas com o termômetro multipolar (37,9 vs 38,45 °C, p=0,018). Não houve diferenças significativas na duração do IVP ou no tempo total de aplicação da radiofrequência (p=0,250 e p=0,253, respectivamente). Conclusões O monitoramento da TEL com termômetro multipolar durante o IVP reduz significativamente a incidência de LTE em comparação com a ausência de monitoramento ou o monitoramento com termômetro unipolar. A implementação de estratégias avançadas de monitoramento da TEL pode aumentar a segurança do paciente sem comprometer a eficiência do procedimento.