Denise Tessariol Hachul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Denise Tessariol Hachul has a total of 369 co-authors. Here are the top co-authors by number of shared publications:
- Mauricio Scanavacca
Universidade de São Paulo, Brasil
37 shared publications - Francisco Darrieux
Universidade de São Paulo, Brasil
27 shared publications - Cristiano Faria Pisani
Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, Brasil
18 shared publications - Luciana Sacilotto
Universidade de São Paulo
9 shared publications Carina Hardy
From the Unidade Clínica de Arritmia, Heart Institute, University of São Paulo Medical School, Brazil
7 shared publications- Gabrielle D.’aRezzo Pessente
Universidade de São Paulo, Brasil
7 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 123 (10)
Diretriz Brasileira de Cardiogeriatria – 2026
Sumário […] Diretriz Brasileira de Cardiogeriatria – 2026 Sumário […] Diretriz Brasileira de Cardiogeriatria – 2026
- 7 October 2026
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 123 (10)
Open AccessDiretriz Brasileira de Cardiogeriatria – 2026
Sumário […] Diretriz Brasileira de Cardiogeriatria – 2026 Sumário […] Diretriz Brasileira de Cardiogeriatria – 2026
- Open Access
- 3 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1718
Dynamic Expression of the Type 1 Brugada ECG Pattern During Tilt Table Testing Using Continuous High Precordial Lead Positioning
Background/Objectives: The Type 1 Brugada ECG pattern (BrP1) fluctuates according to autonomic influences. Tilt table testing induces changes in both sympathetic and parasympathetic activity. It may provide insights into the dynamic behavior of BrP1 when combined with high-precordial lead placement. However, the clinical significance of BrP1 variability during tilt table testing remains poorly defined. Methods: This cross-sectional study evaluated patients with confirmed Brugada syndrome who underwent tilt table testing with continuous ECG monitoring using high-precordial leads. BrP1 behavior was assessed during predefined phases: baseline supine position, orthostatic tilt, nitrate administration, recovery, and syncope when present. Subsequently, clinical characteristics and test results were analyzed for associations with dynamic BrP1 expression. Results: Forty-four patients (mean age 49 years; 72.7% men) were included. Thirty-five patients (79.5%) had a spontaneous type 1 Brugada ECG pattern, and nine (20.5%) had a drug-induced pattern. BrP1 expression varied dynamically/heterogeneously during tilt table testing. No patient without BrP1 at admission developed the pattern during tilt phases. Thirty patients (68.1%) remained negative throughout testing, while five lost the pattern during the test (11.3%), and nine (20.4%) showed persistent BrP1 in all phases. Persistent BrP1 was associated with more frequent presumed arrhythmic syncope and implantable cardioverter defibrillator implantation (p < 0.05). No atrial or ventricular arrhythmias or device-related complications occurred. Conclusions: Tilt table testing with high precordial leads does not unmask BrP1 and should not be used as a diagnostic provocation tool. However, it allows for the characterization of autonomic modulation and phenotypic stability in Brugada syndrome. Any potential prognostic relevance of dynamic BrP1 behavior remains speculative and requires evaluation in adequately powered prospective studies.
- 3 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1718
Open AccessDynamic Expression of the Type 1 Brugada ECG Pattern During Tilt Table Testing Using Continuous High Precordial Lead Positioning
Background/Objectives: The Type 1 Brugada ECG pattern (BrP1) fluctuates according to autonomic influences. Tilt table testing induces changes in both sympathetic and parasympathetic activity. It may provide insights into the dynamic behavior of BrP1 when combined with high-precordial lead placement. However, the clinical significance of BrP1 variability during tilt table testing remains poorly defined. Methods: This cross-sectional study evaluated patients with confirmed Brugada syndrome who underwent tilt table testing with continuous ECG monitoring using high-precordial leads. BrP1 behavior was assessed during predefined phases: baseline supine position, orthostatic tilt, nitrate administration, recovery, and syncope when present. Subsequently, clinical characteristics and test results were analyzed for associations with dynamic BrP1 expression. Results: Forty-four patients (mean age 49 years; 72.7% men) were included. Thirty-five patients (79.5%) had a spontaneous type 1 Brugada ECG pattern, and nine (20.5%) had a drug-induced pattern. BrP1 expression varied dynamically/heterogeneously during tilt table testing. No patient without BrP1 at admission developed the pattern during tilt phases. Thirty patients (68.1%) remained negative throughout testing, while five lost the pattern during the test (11.3%), and nine (20.4%) showed persistent BrP1 in all phases. Persistent BrP1 was associated with more frequent presumed arrhythmic syncope and implantable cardioverter defibrillator implantation (p < 0.05). No atrial or ventricular arrhythmias or device-related complications occurred. Conclusions: Tilt table testing with high precordial leads does not unmask BrP1 and should not be used as a diagnostic provocation tool. However, it allows for the characterization of autonomic modulation and phenotypic stability in Brugada syndrome. Any potential prognostic relevance of dynamic BrP1 behavior remains speculative and requires evaluation in adequately powered prospective studies.
- 14 November 2025
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 141 (4) , 486-494
Proposal for a tooth extraction protocol for patients taking direct oral anticoagulants: a clinical trial
- 14 November 2025
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 141 (4) , 486-494
Proposal for a tooth extraction protocol for patients taking direct oral anticoagulants: a clinical trial
- Open Access
- 14 October 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
Brazilian Atrial Fibrillation Guidelines – 2025
- 14 October 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
Open AccessBrazilian Atrial Fibrillation Guidelines – 2025
- 16 September 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 122 (09) , e20250618
Diretriz Brasileira de Fibrilação Atrial – 2025
- 16 September 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 122 (09) , e20250618
Diretriz Brasileira de Fibrilação Atrial – 2025
- Open Access
- 1 March 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 122 (3)
Esophageal Protection Strategies for Ablation of Atrial Fibrillation: Comparative Results of Consecutive Endoscopic Evaluation
Background Atrial-esophageal fistula following AF ablation remains a concern. There is no standardized approach to minimize its risk and morbidity. Objective To present the seven-year experience of a systematic endoscopic surveillance of esophageal injury after AF catheter ablation. Methods This is a retrospective single center registry of systematic endoscopic evaluation after AF ablation in consecutive procedures performed from 2016 to 2022. A p-value of <0.05 was considered statistically significant. Results 823 AF ablation with controlled esophagogastroduodenoscopy (EGD) were analyzed. Most patients (n=588, 71.4%) were male, 575 (69.9%) had paroxysmal AF. Esophageal temperature monitoring was performed using a single sensor in 310 patients (40.3%) and a multi–sensor probe in 306 (39.8%). Lesions were presented in 217 EGD (26.5%): hematoma-ecchymosis in 27 (3.3%), erythema in 14 (1.7%), erosion in 78 (9.5%) and ulcer in 67 (8.2%) patients. No esophageal protective strategy was associated with more ulcers, except the use of 8mm tip-catheter (14.7% of ulcers with 8mm tip catheter vs 6.7% with other catheters, p = 0.001). Thermal lesions were early detected and treated. Most lesions were considered healed at endoscopy, but one patient who underwent pulmonary vein isolation with an 8m tip catheter had esophageal fistula, treated successfully with endoscopic metal clip and endoloop technique. Conclusion The incidence of esophageal lesions at routine EGD following AF ablation is high, although in most of the cases they heal spontaneously. Patients who underwent ablation with the 8mm tip catheter had more severe thermal lesions. Early esophagus endoscopy may help the diagnosis of early-stage lesions and the prevention of fistula formation after AF ablation.
- 1 March 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 122 (3)
Open AccessEsophageal Protection Strategies for Ablation of Atrial Fibrillation: Comparative Results of Consecutive Endoscopic Evaluation
Background Atrial-esophageal fistula following AF ablation remains a concern. There is no standardized approach to minimize its risk and morbidity. Objective To present the seven-year experience of a systematic endoscopic surveillance of esophageal injury after AF catheter ablation. Methods This is a retrospective single center registry of systematic endoscopic evaluation after AF ablation in consecutive procedures performed from 2016 to 2022. A p-value of <0.05 was considered statistically significant. Results 823 AF ablation with controlled esophagogastroduodenoscopy (EGD) were analyzed. Most patients (n=588, 71.4%) were male, 575 (69.9%) had paroxysmal AF. Esophageal temperature monitoring was performed using a single sensor in 310 patients (40.3%) and a multi–sensor probe in 306 (39.8%). Lesions were presented in 217 EGD (26.5%): hematoma-ecchymosis in 27 (3.3%), erythema in 14 (1.7%), erosion in 78 (9.5%) and ulcer in 67 (8.2%) patients. No esophageal protective strategy was associated with more ulcers, except the use of 8mm tip-catheter (14.7% of ulcers with 8mm tip catheter vs 6.7% with other catheters, p = 0.001). Thermal lesions were early detected and treated. Most lesions were considered healed at endoscopy, but one patient who underwent pulmonary vein isolation with an 8m tip catheter had esophageal fistula, treated successfully with endoscopic metal clip and endoloop technique. Conclusion The incidence of esophageal lesions at routine EGD following AF ablation is high, although in most of the cases they heal spontaneously. Patients who underwent ablation with the 8mm tip catheter had more severe thermal lesions. Early esophagus endoscopy may help the diagnosis of early-stage lesions and the prevention of fistula formation after AF ablation.
- Open Access
- 1 March 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 122 (3) , e20230913
Estratégias de Proteção Esofágica para Ablação de Fibrilação Atrial: Resultados Comparativos de Avaliações Endoscópicas Consecutivas
Resumo Fundamento A ocorrência de fístula atrioesofágica após o procedimento ode ablação de fibrilação atrial (FA) continua uma preocupação. Não existe uma abordagem padronizada para minimizar seus riscos e mortalidade. Objetivos Apresentar a experiência de sete anos de um monitoramento endoscópico sistemático de lesão esofágica após a ablação de FA por cateter. Métodos Estudo unicêntrico retrospectivo de avaliação endoscópica sistemática após ablação e FA em procedimentos consecutivos realizados entre 2016 e 2022. Um valor de p < 0.05 foi considerado estatisticamente significativo. Resultados Foram analisados 823 procedimentos de ablação de FA com Esofagogastroduodenoscopia (EGD) de controle. A maioria (n=588; 71,4%) dos pacientes submetidos ao procedimento era do sexo masculino, 575 (69,9%) apresentaram FA paroxística. Monitoramento da temperatura esofágica foi realizada usando um sensor único em 310 pacientes (40,3%) e uma sonda multissensor em 306 (39,8%) pacientes. As lesões estavam presentes em 217 EGD (26,5%): hematoma-equimose em 27 (3,3%), eritema em 14 (1,7%), erosão em 78 (9,5%) e úlcera em 67 (8,2%) pacientes. Nenhuma estratégia de proteção do esôfago foi associada à maior ocorrência de úlceras, com exceção do uso de cateter de ponta de 8mm (14,7% de úlceras com cateter de ponta de 8mm vs. 6,7% com outros cateteres, p = 0,001). Lesões térmicas foram detectadas precocemente e tratadas. A maioria das lesões foi considerada curada na endoscopia, mas um paciente que foi submetido ao isolamento da veia pulmonar com um cateter de ponta de 8mm apresentou fístula esofágica, que foi tratada com sucesso com clipe metálico endoscópico e técnica endoloop. Conclusão A incidência de lesões esofágicas é alta na EGD de rotina realizada após a ablação de FA, embora, na maioria dos casos, sua cura ocorra espontaneamente. Pacientes que se submeteram à ablação com o cateter de ponta de 8mm apresentaram lesões térmicas mais graves. Endoscopia esofágica precoce pode ajudar no diagnóstico de lesões em fases iniciais e a prevenção de fístulas após a ablação de FA.
- 1 March 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 122 (3) , e20230913
Open AccessEstratégias de Proteção Esofágica para Ablação de Fibrilação Atrial: Resultados Comparativos de Avaliações Endoscópicas Consecutivas
Resumo Fundamento A ocorrência de fístula atrioesofágica após o procedimento ode ablação de fibrilação atrial (FA) continua uma preocupação. Não existe uma abordagem padronizada para minimizar seus riscos e mortalidade. Objetivos Apresentar a experiência de sete anos de um monitoramento endoscópico sistemático de lesão esofágica após a ablação de FA por cateter. Métodos Estudo unicêntrico retrospectivo de avaliação endoscópica sistemática após ablação e FA em procedimentos consecutivos realizados entre 2016 e 2022. Um valor de p < 0.05 foi considerado estatisticamente significativo. Resultados Foram analisados 823 procedimentos de ablação de FA com Esofagogastroduodenoscopia (EGD) de controle. A maioria (n=588; 71,4%) dos pacientes submetidos ao procedimento era do sexo masculino, 575 (69,9%) apresentaram FA paroxística. Monitoramento da temperatura esofágica foi realizada usando um sensor único em 310 pacientes (40,3%) e uma sonda multissensor em 306 (39,8%) pacientes. As lesões estavam presentes em 217 EGD (26,5%): hematoma-equimose em 27 (3,3%), eritema em 14 (1,7%), erosão em 78 (9,5%) e úlcera em 67 (8,2%) pacientes. Nenhuma estratégia de proteção do esôfago foi associada à maior ocorrência de úlceras, com exceção do uso de cateter de ponta de 8mm (14,7% de úlceras com cateter de ponta de 8mm vs. 6,7% com outros cateteres, p = 0,001). Lesões térmicas foram detectadas precocemente e tratadas. A maioria das lesões foi considerada curada na endoscopia, mas um paciente que foi submetido ao isolamento da veia pulmonar com um cateter de ponta de 8mm apresentou fístula esofágica, que foi tratada com sucesso com clipe metálico endoscópico e técnica endoloop. Conclusão A incidência de lesões esofágicas é alta na EGD de rotina realizada após a ablação de FA, embora, na maioria dos casos, sua cura ocorra espontaneamente. Pacientes que se submeteram à ablação com o cateter de ponta de 8mm apresentaram lesões térmicas mais graves. Endoscopia esofágica precoce pode ajudar no diagnóstico de lesões em fases iniciais e a prevenção de fístulas após a ablação de FA.
- 14 January 2025
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (2) , 405-409
Unicentric Brazilian registry of cardiac sympathetic denervation for control of ventricular arrhythmias
- 14 January 2025
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (2) , 405-409
Unicentric Brazilian registry of cardiac sympathetic denervation for control of ventricular arrhythmias
- Open Access
- 1 January 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 122 (7) , e20250056
Monitoramento da Temperatura Esofágica durante a Ablação de Fibrilação Atrial: Um Estudo Randomizado
Resumo Fundamento O isolamento das veias pulmonares (IVP) para a ablação da fibrilação atrial (FA) apresenta risco de lesão térmica esofágica (LTE), que pode levar a complicações graves. Objetivo Avaliar três estratégias de monitoramento da temperatura esofágica luminal (TEL) e analisar sua eficácia na redução da incidência de LTE. Métodos Pacientes com FA foram randomizados em três grupos de IVP, conforme a estratégia de monitoramento da temperatura: sem monitoramento de TEL (Grupo 1), monitoramento de TEL com termômetro unipolar (Grupo 2) e monitoramento de TEL com termômetro multipolar (Grupo 3). No Grupo 1, a ablação da FA foi realizada com potência fixa de 20 W na parede posterior do átrio esquerdo. Nos Grupos 2 e 3, a potência da ablação foi ajustada com base nas medições da TEL, utilizando como limite a temperatura de 37,5 °C. Cada grupo incluiu 20 pacientes. Considerou-se estatisticamente significativo um valor de p bilateral <0,05. O estudo foi registrado no ClinicalTrials.gov (#NCT03645070) e na International Clinical Trials Registry Platform (#RBR-2yvgyf). Resultados Todos os pacientes foram submetidos a IVP e à esofagogastroduodenoscopia. Nenhum caso de LTE foi observado em pacientes monitorados com o termômetro multipolar. Em contraste, cinco pacientes sem monitoramento de TEL e seis pacientes monitorados com o termômetro unipolar desenvolveram LTE (p=0,006). Temperaturas mais elevadas foram registradas com o termômetro multipolar (37,9 vs 38,45 °C, p=0,018). Não houve diferenças significativas na duração do IVP ou no tempo total de aplicação da radiofrequência (p=0,250 e p=0,253, respectivamente). Conclusões O monitoramento da TEL com termômetro multipolar durante o IVP reduz significativamente a incidência de LTE em comparação com a ausência de monitoramento ou o monitoramento com termômetro unipolar. A implementação de estratégias avançadas de monitoramento da TEL pode aumentar a segurança do paciente sem comprometer a eficiência do procedimento.
- 1 January 2025
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 122 (7) , e20250056
Open AccessMonitoramento da Temperatura Esofágica durante a Ablação de Fibrilação Atrial: Um Estudo Randomizado
Resumo Fundamento O isolamento das veias pulmonares (IVP) para a ablação da fibrilação atrial (FA) apresenta risco de lesão térmica esofágica (LTE), que pode levar a complicações graves. Objetivo Avaliar três estratégias de monitoramento da temperatura esofágica luminal (TEL) e analisar sua eficácia na redução da incidência de LTE. Métodos Pacientes com FA foram randomizados em três grupos de IVP, conforme a estratégia de monitoramento da temperatura: sem monitoramento de TEL (Grupo 1), monitoramento de TEL com termômetro unipolar (Grupo 2) e monitoramento de TEL com termômetro multipolar (Grupo 3). No Grupo 1, a ablação da FA foi realizada com potência fixa de 20 W na parede posterior do átrio esquerdo. Nos Grupos 2 e 3, a potência da ablação foi ajustada com base nas medições da TEL, utilizando como limite a temperatura de 37,5 °C. Cada grupo incluiu 20 pacientes. Considerou-se estatisticamente significativo um valor de p bilateral <0,05. O estudo foi registrado no ClinicalTrials.gov (#NCT03645070) e na International Clinical Trials Registry Platform (#RBR-2yvgyf). Resultados Todos os pacientes foram submetidos a IVP e à esofagogastroduodenoscopia. Nenhum caso de LTE foi observado em pacientes monitorados com o termômetro multipolar. Em contraste, cinco pacientes sem monitoramento de TEL e seis pacientes monitorados com o termômetro unipolar desenvolveram LTE (p=0,006). Temperaturas mais elevadas foram registradas com o termômetro multipolar (37,9 vs 38,45 °C, p=0,018). Não houve diferenças significativas na duração do IVP ou no tempo total de aplicação da radiofrequência (p=0,250 e p=0,253, respectivamente). Conclusões O monitoramento da TEL com termômetro multipolar durante o IVP reduz significativamente a incidência de LTE em comparação com a ausência de monitoramento ou o monitoramento com termômetro unipolar. A implementação de estratégias avançadas de monitoramento da TEL pode aumentar a segurança do paciente sem comprometer a eficiência do procedimento.