Fiona Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fiona Smith has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Marc Augsburger
University Center of Legal Medicine, Lausanne and Geneva University Hospitals, 1000 Lausanne, Switzerland
7 shared publications - Vincent Varlet
Forensic Toxicology and Chemistry Unit, University Center of Legal Medicine Lausanne - Geneva, CH-1011 Lausanne, Switzerland
7 shared publications - David Brutin
Aix Marseille Univ, CNRS, IUSTI, Marseille, France
4 shared publications A. Dominguez
Forensic Imaging Unit, University Center of Legal Medicine Lausanne - Geneva, CH-1011 Lausanne, Switzerland; HESAV - Department of Radiography, Avenue de Beaumont 21, CH-1011 Lausanne, Switzerland
2 shared publicationsA. Rinaldi
Forensic Imaging Unit, University Center of Legal Medicine Lausanne - Geneva, CH-1011 Lausanne, Switzerland; HESAV - Department of Radiography, Avenue de Beaumont 21, CH-1011 Lausanne, Switzerland
2 shared publicationsP. Mangin
Forensic Imaging Unit, University Center of Legal Medicine Lausanne - Geneva, CH-1011 Lausanne, Switzerland
2 shared publications
Latest Publications
- 1 July 2018
- Published by Elsevier in Current Opinion in Colloid & Interface Science
- Vol. 36, 78-83
Wetting and spreading of human blood: Recent advances and applications
- 1 July 2018
- Published by Elsevier in Current Opinion in Colloid & Interface Science
- Vol. 36, 78-83
Wetting and spreading of human blood: Recent advances and applications
- 11 January 2018
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 3 (1) , 013601
Influence of the impact energy on the pattern of blood drip stains
The maximum spreading diameter of complex fluid droplets has been extensively studied and explained by numerous physical models. This research focuses therefore on a different aspect, the bulging outer rim observed after evaporation on the final dried pattern of blood droplets. A correlation is found between the inner diameter, the maximum outer diameter, and the impact speed. This shows how the drying mechanism of a blood drip stain is influenced by the impact energy, which induces a larger spreading diameter and thus a different redistribution of red blood cells inside the droplet. An empirical relation is established between the final dried pattern of a passive bloodstain and its impact speed, yielding a possible forensic application. Indeed, being able to relate accurately the energy of the drop with its final pattern would give a clue to investigators, as currently no such simple and accurate tool exists.
- 11 January 2018
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 3 (1) , 013601
Influence of the impact energy on the pattern of blood drip stains
The maximum spreading diameter of complex fluid droplets has been extensively studied and explained by numerous physical models. This research focuses therefore on a different aspect, the bulging outer rim observed after evaporation on the final dried pattern of blood droplets. A correlation is found between the inner diameter, the maximum outer diameter, and the impact speed. This shows how the drying mechanism of a blood drip stain is influenced by the impact energy, which induces a larger spreading diameter and thus a different redistribution of red blood cells inside the droplet. An empirical relation is established between the final dried pattern of a passive bloodstain and its impact speed, yielding a possible forensic application. Indeed, being able to relate accurately the energy of the drop with its final pattern would give a clue to investigators, as currently no such simple and accurate tool exists.
- 7 November 2017
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 34 (3) , 1143-1150
Roughness Influence on Human Blood Drop Spreading and Splashing
Bloodstain pattern analysis (BPA) is used on a daily basis as evidence in crime scene reconstruction. However, though the impact behavior of complex fluid droplets have been extensively studied, important questions still remain. We investigate the influence of surface roughness and wettability on the splashing limit of droplets of blood, a non-Newtonian colloidal fluid. Droplets of blood perpendicularly impacting different surfaces at different velocities were recorded with a high-speed camera. The recordings were analyzed as well as the surfaces characteristics in order to find an empirical solution because we found that roughness plays a major role in the threshold of the splashing/nonsplashing behavior of blood compared to the wettability. Moreover, it appears that roughness alters the deformation of the drip stains. These observations are key to characterizing features of drip stains with the impacting conditions, yielding a more complete forensic analysis in certain cases.
- 7 November 2017
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 34 (3) , 1143-1150
Roughness Influence on Human Blood Drop Spreading and Splashing
Bloodstain pattern analysis (BPA) is used on a daily basis as evidence in crime scene reconstruction. However, though the impact behavior of complex fluid droplets have been extensively studied, important questions still remain. We investigate the influence of surface roughness and wettability on the splashing limit of droplets of blood, a non-Newtonian colloidal fluid. Droplets of blood perpendicularly impacting different surfaces at different velocities were recorded with a high-speed camera. The recordings were analyzed as well as the surfaces characteristics in order to find an empirical solution because we found that roughness plays a major role in the threshold of the splashing/nonsplashing behavior of blood compared to the wettability. Moreover, it appears that roughness alters the deformation of the drip stains. These observations are key to characterizing features of drip stains with the impacting conditions, yielding a more complete forensic analysis in certain cases.
- 1 October 2016
- Published by Elsevier in Forensic Science International
- Vol. 267, 104-109
Morphology of drying blood pools
- 1 October 2016
- Published by Elsevier in Forensic Science International
- Vol. 267, 104-109
Morphology of drying blood pools
- 1 June 2015
- Published by Elsevier in Forensic Science International
- Vol. 251, 1-10
When gas analysis assists with postmortem imaging to diagnose causes of death
- 1 June 2015
- Published by Elsevier in Forensic Science International
- Vol. 251, 1-10
When gas analysis assists with postmortem imaging to diagnose causes of death
- 1 January 2014
- Published by Elsevier in Food Chemistry
- Vol. 142, 311-317
New trends in the kitchen: Propellants assessment of edible food aerosol sprays used on food
- 1 January 2014
- Published by Elsevier in Food Chemistry
- Vol. 142, 311-317
New trends in the kitchen: Propellants assessment of edible food aerosol sprays used on food
- Open Access
- 9 December 2013
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 38 (2) , 73-79
Accuracy Profile Validation of a New Analytical Method for Propane Measurement Using Headspace-Gas Chromatography-Mass Spectrometry
Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography–mass spectrometry (GC–MS) methods of propane measurements do already exist. The main drawback of these GC–MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC–MS method (HS-GC–MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C3DH7) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D2O) with Grignard reagent propylmagnesium chloride (C3H7MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.
- 9 December 2013
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 38 (2) , 73-79
Open AccessAccuracy Profile Validation of a New Analytical Method for Propane Measurement Using Headspace-Gas Chromatography-Mass Spectrometry
Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography–mass spectrometry (GC–MS) methods of propane measurements do already exist. The main drawback of these GC–MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC–MS method (HS-GC–MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C3DH7) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D2O) with Grignard reagent propylmagnesium chloride (C3H7MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.
- 10 July 2013
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 48 (8) , 914-918
Indirect hydrogen analysis by gas chromatography coupled to mass spectrometry (GC–MS)
Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. The different gases are separated by specific columns but, if hydrogen (H2) is present in the sample, its detection can be performed by a thermal conductivity detector or a helium ionization detector. Indeed, coupled to GC, no other detector can perform this detection except the expensive atomic emission detector. Based on the detection and analysis of H2 isotopes by low‐pressure chemical ionization mass spectrometry (MS), a new method for H2 detection by GC coupled to MS with an electron ionization ion source and a quadrupole analyser is presented. The presence of H2 in a gaseous mixture could easily be put in evidence by the monitoring of the molecular ion of the protonated carrier gas. Copyright © 2013 John Wiley & Sons, Ltd.
- 10 July 2013
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 48 (8) , 914-918
Indirect hydrogen analysis by gas chromatography coupled to mass spectrometry (GC–MS)
Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. The different gases are separated by specific columns but, if hydrogen (H2) is present in the sample, its detection can be performed by a thermal conductivity detector or a helium ionization detector. Indeed, coupled to GC, no other detector can perform this detection except the expensive atomic emission detector. Based on the detection and analysis of H2 isotopes by low‐pressure chemical ionization mass spectrometry (MS), a new method for H2 detection by GC coupled to MS with an electron ionization ion source and a quadrupole analyser is presented. The presence of H2 in a gaseous mixture could easily be put in evidence by the monitoring of the molecular ion of the protonated carrier gas. Copyright © 2013 John Wiley & Sons, Ltd.
- 27 May 2013
- Published by Wiley in Journal of Separation Science
- Vol. 36 (12) , 1967-1972
Validation of methane measurement using headspace‐GC–MS and quantification by a stable isotope‐labeled internal standard generated in situ
A previous study has shown the possibility to identify methane (CH4) using headspace‐GC–MS and quantify it with a stable isotope as internal standard. The main drawback of the GC–MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope‐labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.
- 27 May 2013
- Published by Wiley in Journal of Separation Science
- Vol. 36 (12) , 1967-1972
Validation of methane measurement using headspace‐GC–MS and quantification by a stable isotope‐labeled internal standard generated in situ
A previous study has shown the possibility to identify methane (CH4) using headspace‐GC–MS and quantify it with a stable isotope as internal standard. The main drawback of the GC–MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope‐labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.