APAshutosh Patel

Ashutosh Patel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ashutosh Patel has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bearing Selection for High-Speed Electrical Machine

    by Kamisetti N V Prasad, Ashutosh Patel, Vijay Biradar, Syed Shahjahan Ahmad, Pramod Kumar, G. Narayanan

    In this paper, various mechanical and electrical reasons and methods to prevent bearing failures are highlighted. The bearing selection for a 5 kW, 10,000 rpm switched reluctance machine (SRM) is carried out by estimating axial and radial forces acting on the rotor assembly and various other bearing parameters. The rotor weight and forces due to the rotation of unbalance residue mass is considered as radial force. To handle axial and radial forces, angular contact bearing is selected. The expected bearing life and corresponding axial loads are estimated. The selected bearings are installed in SRM. Further, the SRM is operated at various speeds with closed-loop speed control using a SiC-based asymmetric H-bridge converter. The bearing performance is validated by measuring vibration on bearing housings at a speed of 10,500 rpm.


  • Harmonic Analysis of the High Speed Direct Coupled SCO2 Turbo-Generator

    by Ashutosh Patel, Vijay Biradar, Pramod Kumar

    The rotordynamics and harmonic characteristics of the rotor assembly designed for 40-kW high-speed sCO2 direct-coupled turbo-generator pair have been evaluated numerically using finite element solver “ANSYS Mechanical”. First, the shaft geometry and dimensions have been optimized using lumped mass-inertia-based AxSTREAM RotorDynamics module followed by the bearing selection analysis using SKF SimPro expert to ensure enough separation margin from the nearby critical speeds. Equivalent 2D geometry has been used with an FEA-based ANSYS general axisymmetric model to reduce the computation time. The effect of the damping on the forces transmitting to the bearings and shaft deflection at the critical speeds are analyzed by performing harmonic analysis under various damped and undamped conditions (ζ = 0, 0.005, 0.01, and 0.02).


  • Enhancement in thermoelectric properties of n-type (La0.7Sr0.3MnO3)0.5.(NiO)0.5: composite and nano-structure effect

    by Saurabh Singh, Simant Kumar Srivastav, Ashutosh Patel, Ashish Kumar, Ratnamala Chatterjee, Tsunehiro Takeuchi, Sudhir K Pandey

    In the enhancement of thermoelectric properties of material for energy harvesting applications, the role of nano-composite made of two different materials plays a very crucial role. When materials with different crystal and electronic structure are synthesized in nano-crystalline phase to form a composite, they provide large power factor via energy filtering effect, whereas the lattice mismatching and grain boundaries of two phase scatter the phonons having wide range of frequencies, and effectively maintain the low thermal conductivity. In the present work, we have reported the structural and thermoelectric properties of (La0.7Sr0.3MnO3)0.5(NiO)0.5 composite synthesized by sol-gel method. Rietveld refinement of the XRD pattern confirms the presence of both phases. Thermoelectric properties are measured in 300–600 K temperature range. The magnitude of Seebeck coefficients, electrical resistivity, and thermal conductivity found to be monotonically increase with temperature upto the ∼450 K, which decrease gradually with further increase in temperature. Such variation in transport properties are resulted from the combine effect from the composite materials formed with semiconducting/metallic, and insulating electronic structure mixed in a 50:50 weight ratio. The calculated ‘figure-of-merit’ (ZT) shows an increasing trend with temperature. The value of ZT max is found to be ∼0.05 at 600 K, which is nearly three times larger than that of La0.7Sr0.3MnO3 (ZT = 0.013) reported earlier. Our strategy of making nano-composite two materials with different electronic structures enhanced the ZT by ∼285%. The improvement in thermoelectric properties of n-type oxide materials can be useful to consider this material for applications in mid-temperature range.


  • Open Access

    Wide range temperature-dependent (80–630 K) study of Hall effect and the Seebeck coefficient of β -Ga2O3 single crystals

    by Ashish Kumar, Saurabh Singh, Bhera Ram Tak, Ashutosh Patel, K. Asokan, D. Kanjilal

    Investigation of the Seebeck coefficient in ultra-wide bandgap materials presents a challenge in measurements; nevertheless, it is essential for understanding fundamental transport mechanisms involved in electrical and thermal conduction. β-Ga2O3 is a strategic material for high-power optoelectronic applications. The present work reports the Seebeck coefficient measurement for single crystal Sn-doped β-Ga2O3 in a wide temperature range (80–630 K). The non-monotonic trend with large magnitude and a negative sign in the entire temperature range shows that electrons are dominant carriers. The structural and Raman characterization confirms the single-phase and the presence of low-, mid-, and high-frequency phonon modes, respectively. The temperature-dependent (90–350 K) Hall effect measurement was carried out as a supplementary study. Hall mobility showed that μ ∝ T1.12 for T < 135 K and μ ∝ T−0.70 for T > 220 K. Activation energies from the Seebeck coefficient and conductivity analysis revealed the presence of interband conduction due to impurity defects. The room temperature Seebeck coefficient, power factor, and thermal conductivity were found to be 68.57 ± 1.27 μV/K, 0.15 ± 0.04 μW/K2 cm, and 14.2 ± 0.6 W/mK, respectively. The value of the figure of merit for β-Ga2O3 was found to be ∼ 0.01 (300 K).


  • Open Access

    Apparatus for Seebeck coefficient measurement of wire, thin film, and bulk materials in the wide temperature range (80–650 K)

    by Ashish Kumar, Ashutosh Patel, Saurabh Singh, Asokan Kandasami, D. Kanjilal

    A Seebeck coefficient measurement apparatus has been designed and developed, which is very effective for accurate characterization of different types of samples in a wide temperature range (80–650 K) simultaneously covering low as well as high temperature regimes. Reducing the complexity of technical design of the sample holder and data collections has always been challenging to implement in a single instrument when samples are in different geometrical shapes and electronic structures. Our unique design of the sample holder with pressure probes covers measurements of different sample shapes (wires, thin films, and pellets) as well as different resistivity ranges (metals, semiconductors, and insulators). It is suitable for characterization of different sample sizes (3–12 mm). A double heater configuration powered by using a dual channel source meter is employed for maintaining a desired constant temperature difference across the sample for the whole temperature range. Two K-type thermocouples are used for simultaneously reading temperatures and Seebeck voltages by utilizing different channels of a multichannel digital multimeter. Calibration of the system has been carried out using constantan, chromel, and alumel materials, and recorded data are found to be very accurate and consistent with earlier reports. The Seebeck coefficients of standard samples of constantan (wire) and GaN (thin film) have been reported, which shows the measurement capability of the designed setup with versatile samples.


  • Effect of nanostructure on thermoelectric properties of La0.7Sr0.3MnO3 in 300–600 K temperature range

    by Saurabh Singh, Simant Kumar Srivastav, Ashutosh Patel, Ratnamala Chatterjee, Sudhir Kumar Pandey


  • Automated instrumentation for the determination of the high-temperature thermoelectric figure-of-merit

    by Ashutosh Patel, Sudhir K. Pandey

    Here we report the fabrication of high temperature measurement instrumentation to measure the thermoelectric figure of merit. This setup facilitates the simultaneous measurement of Seebeck coefficient, thermal conductivity, and electrical resistivity required to evaluate the figure of merit. Measurement of temperature, as well as voltages using same thermocouples, simplified the design by minimizing sensors and wires. The limited number of components in the sample holder further simplify the design and make it small in size and lightweight. A dedicated thin heater has been constructed to minimize heat losses. Further, low heat loss is achieved by optimizing the insulator dimensions. To measure power delivered to the heater, the four-wire technique was used. Low cost and commonly available materials used in the fabrication of various components make it more accessible to the user as any parts can be easily replaced in case of damage. A dedicated program was built in the Python language to automate the measurement process. A p-type Bi0.36Sb1.45Te3 sample was used to calibrate the instrumentation. The measured values were in good agreement with the literature results.


  • Open Access

    Automated Instrumentation for the Determination of the High-Temperature Thermoelectric Figure-of-Merit

    by Ashutosh Patel, Sudhir K. Pandey

    In this work, we report the fabrication of a high temperature measurement setup to measure Figure of merit (ZT). This setup facilitates the simultaneous measurement of Seebeck coefficient ({\alpha}), thermal conductivity (\kappa), and electrical resistivity (\rho) required to calculate ZT. Measurement of temperature, as well as voltages using same thermocouples, simplified the design of the setup by minimizing sensors and wires. Limited components used in the sample holder further simplify the design and make it small in size and lightweight. The dedicated thin heater is made, which minimizes the heat loss. Further, low heat loss is achieved by optimizing the insulator dimension. To measure power delivered to the heater, 4-wire technique is used. Low cost and commonly available materials used in the fabrication of various components make it more accessible to the user as any parts can be easily replaced in case of any damage occurs. A dedicated program is built in the Python programming language to automate the whole measurement process. p-type Bi0.36Sb1.45Te3 sample is used to calibrate this measurement setup. The data collected are found to be in good agreement with the reported data.

  • Direct evidence of the existence of Mn 3+ ions in MnTiO 3

    by R. K. Maurya, Priyamedha Sharma, Ashutosh Patel, R. Bindu