Marc Allain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marc Allain has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
- Simon Labouesse
Aix Marseille Université, CNRS, Centrale Marseille, Institut Fresnel, UMR 7249, 13013 Marseille, France
4 shared publications - Virginie Chamard
Institut Fresnel
4 shared publications - Anne Sentenac
Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France
3 shared publications - Jérôme Idier
Nantes Université, École Centrale Nantes, CNRS, LS2N, Nantes, France
3 shared publications - Tilman A. Grünewald
Aix-Marseille Univ, CNRS, Centrale Med, Institut Fresnel, 13013 Marseille, France
3 shared publications - Allard Pieter Mosk
Debye Institute for Nanomaterials Science, Utrecht University, Utrecht, Netherlands
2 shared publications
Latest Publications
- 29 January 2026
- Published by IOP Publishing in Inverse Problems
- Vol. 42 (2)
Pseudo-random illumination microscopy (P-RIM)
Structured illumination microscopy (SIM) is a well-established mean to obtain super-resolved images of fluorescent biological samples, with a two-fold resolution gain. However, it relies on the precise knowledge of the excitation patterns, which is an issue in the presence of uncontrolled pattern distorsions. Random illumination microscopy (RIM) is an alternate solution, built upon a larger number of unknown, randomly generated excitation patterns of controlled statistics, and on a variance-matching process for the super-resolved reconstruction step. In this paper, we propose Pseudo-RIM (PRIM), a novel approach where the sample is illuminated with a limited number of structured patterns as in SIM, combined with a matching process based on second-order statistics as in RIM. We explore mathematical conditions under which PRIM has a provable super-resolution capacity comparable to SIM and RIM, and we show how to build valid combinations of pseudo-random illuminations. Several pattern sets commonly used in SIM are also compatible with PRIM, which allows us to compare the behavior of PRIM with that of SIM on the same simulated dataset, in the presence of pattern distorsions. This empirical test empirically validates that PRIM variance data processing is nearly insensitive to pattern distorsions, compared to SIM joint least-squares demodulation.
- 29 January 2026
- Published by IOP Publishing in Inverse Problems
- Vol. 42 (2)
Pseudo-random illumination microscopy (P-RIM)
Structured illumination microscopy (SIM) is a well-established mean to obtain super-resolved images of fluorescent biological samples, with a two-fold resolution gain. However, it relies on the precise knowledge of the excitation patterns, which is an issue in the presence of uncontrolled pattern distorsions. Random illumination microscopy (RIM) is an alternate solution, built upon a larger number of unknown, randomly generated excitation patterns of controlled statistics, and on a variance-matching process for the super-resolved reconstruction step. In this paper, we propose Pseudo-RIM (PRIM), a novel approach where the sample is illuminated with a limited number of structured patterns as in SIM, combined with a matching process based on second-order statistics as in RIM. We explore mathematical conditions under which PRIM has a provable super-resolution capacity comparable to SIM and RIM, and we show how to build valid combinations of pseudo-random illuminations. Several pattern sets commonly used in SIM are also compatible with PRIM, which allows us to compare the behavior of PRIM with that of SIM on the same simulated dataset, in the presence of pattern distorsions. This empirical test empirically validates that PRIM variance data processing is nearly insensitive to pattern distorsions, compared to SIM joint least-squares demodulation.
- Open Access
- 21 October 2025
- Published by Springer Nature in Sampling Theory, Signal Processing, and Data Analysis
- Vol. 23 (2) , 1-40
Phasebook: a survey of selected open problems in phase retrieval
Phase retrieval is an inverse problem that, on one hand, is crucial in many applications across imaging and physics, and, on the other hand, leads to deep research questions in theoretical signal processing and applied harmonic analysis. This survey paper is an outcome of the recent workshop Phase Retrieval in Mathematics and Applications (PRiMA) (held on August 5–9 2024 at the Lorentz Center in Leiden, The Netherlands) that brought together experts working on theoretical and practical aspects of the phase retrieval problem with the purpose to formulate and explore essential open problems in the field.
- 21 October 2025
- Published by Springer Nature in Sampling Theory, Signal Processing, and Data Analysis
- Vol. 23 (2) , 1-40
Open AccessPhasebook: a survey of selected open problems in phase retrieval
Phase retrieval is an inverse problem that, on one hand, is crucial in many applications across imaging and physics, and, on the other hand, leads to deep research questions in theoretical signal processing and applied harmonic analysis. This survey paper is an outcome of the recent workshop Phase Retrieval in Mathematics and Applications (PRiMA) (held on August 5–9 2024 at the Lorentz Center in Leiden, The Netherlands) that brought together experts working on theoretical and practical aspects of the phase retrieval problem with the purpose to formulate and explore essential open problems in the field.
- Open Access
Phasebook: A Survey of Selected Open Problems in Phase Retrieval
Phase retrieval is an inverse problem that, on one hand, is crucial in many applications across imaging and physics, and, on the other hand, leads to deep research questions in theoretical signal processing and applied harmonic analysis. This survey paper is an outcome of the recent workshop Phase Retrieval in Mathematics and Applications (PRiMA) (held on August 5--9 2024 at the Lorentz Center in Leiden, The Netherlands) that brought together experts working on theoretical and practical aspects of the phase retrieval problem with the purpose to formulate and explore essential open problems in the field.
Open AccessPhasebook: A Survey of Selected Open Problems in Phase Retrieval
Phase retrieval is an inverse problem that, on one hand, is crucial in many applications across imaging and physics, and, on the other hand, leads to deep research questions in theoretical signal processing and applied harmonic analysis. This survey paper is an outcome of the recent workshop Phase Retrieval in Mathematics and Applications (PRiMA) (held on August 5--9 2024 at the Lorentz Center in Leiden, The Netherlands) that brought together experts working on theoretical and practical aspects of the phase retrieval problem with the purpose to formulate and explore essential open problems in the field.
- 30 October 2024
- Published by American Physical Society (APS) in Physical Review B
- Vol. 110 (13)
Inhomogeneous probes for Bragg coherent diffraction imaging: Toward the imaging of dynamic and distorted crystals
- 30 October 2024
- Published by American Physical Society (APS) in Physical Review B
- Vol. 110 (13)
Inhomogeneous probes for Bragg coherent diffraction imaging: Toward the imaging of dynamic and distorted crystals
- Open Access
- 10 October 2024
- Published by Springer Nature in Light: Science & Applications
- Vol. 13 (1) , 1-12
Extended-depth of field random illumination microscopy, EDF-RIM, provides super-resolved projective imaging
The ultimate aim of fluorescence microscopy is to achieve high-resolution imaging of increasingly larger biological samples. Extended depth of field presents a potential solution to accelerate imaging of large samples when compression of information along the optical axis is not detrimental to the interpretation of images. We have implemented an extended depth of field (EDF) approach in a random illumination microscope (RIM). RIM uses multiple speckled illuminations and variance data processing to double the resolution. It is particularly adapted to the imaging of thick samples as it does not require the knowledge of illumination patterns. We demonstrate highly-resolved projective images of biological tissues and cells. Compared to a sequential scan of the imaged volume with conventional 2D-RIM, EDF-RIM allows an order of magnitude improvement in speed and light dose reduction, with comparable resolution. As the axial information is lost in an EDF modality, we propose a method to retrieve the sample topography for samples that are organized in cell sheets.
- 10 October 2024
- Published by Springer Nature in Light: Science & Applications
- Vol. 13 (1) , 1-12
Open AccessExtended-depth of field random illumination microscopy, EDF-RIM, provides super-resolved projective imaging
The ultimate aim of fluorescence microscopy is to achieve high-resolution imaging of increasingly larger biological samples. Extended depth of field presents a potential solution to accelerate imaging of large samples when compression of information along the optical axis is not detrimental to the interpretation of images. We have implemented an extended depth of field (EDF) approach in a random illumination microscope (RIM). RIM uses multiple speckled illuminations and variance data processing to double the resolution. It is particularly adapted to the imaging of thick samples as it does not require the knowledge of illumination patterns. We demonstrate highly-resolved projective images of biological tissues and cells. Compared to a sequential scan of the imaged volume with conventional 2D-RIM, EDF-RIM allows an order of magnitude improvement in speed and light dose reduction, with comparable resolution. As the axial information is lost in an EDF modality, we propose a method to retrieve the sample topography for samples that are organized in cell sheets.
- Open Access
- 24 July 2024
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 11 (5) , 809-820
Texture tomography, a versatile framework to study crystalline texture in 3D
Crystallographic texture is a key organization feature of many technical and biological materials. In these materials, especially hierarchically structured ones, the preferential alignment of the nano constituents heavily influences the macroscopic behavior of the material. To study local crystallographic texture with both high spatial and angular resolution, we developed Texture Tomography (TexTOM). This approach allows the user to model the diffraction data of polycrystalline materials using the full reciprocal space of the crystal ensemble and describe the texture in each voxel via an orientation distribution function, hence it provides 3D reconstructions of the local texture by measuring the probabilities of all crystal orientations. The TexTOM approach addresses limitations associated with existing models: it correlates the intensities from several Bragg reflections, thus reducing ambiguities resulting from symmetry. Further, it yields quantitative probability distributions of local real space crystal orientations without further assumptions about the sample structure. Finally, its efficient mathematical formulation enables reconstructions faster than the time scale of the experiment. This manuscript presents the mathematical model, the inversion strategy and its current experimental implementation. We show characterizations of simulated data as well as experimental data obtained from a synthetic, inorganic model sample: the silica–witherite biomorph. TexTOM provides a versatile framework to reconstruct 3D quantitative texture information for polycrystalline samples; it opens the door for unprecedented insights into the nanostructural makeup of natural and technical materials.
- 24 July 2024
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 11 (5) , 809-820
Open AccessTexture tomography, a versatile framework to study crystalline texture in 3D
Crystallographic texture is a key organization feature of many technical and biological materials. In these materials, especially hierarchically structured ones, the preferential alignment of the nano constituents heavily influences the macroscopic behavior of the material. To study local crystallographic texture with both high spatial and angular resolution, we developed Texture Tomography (TexTOM). This approach allows the user to model the diffraction data of polycrystalline materials using the full reciprocal space of the crystal ensemble and describe the texture in each voxel via an orientation distribution function, hence it provides 3D reconstructions of the local texture by measuring the probabilities of all crystal orientations. The TexTOM approach addresses limitations associated with existing models: it correlates the intensities from several Bragg reflections, thus reducing ambiguities resulting from symmetry. Further, it yields quantitative probability distributions of local real space crystal orientations without further assumptions about the sample structure. Finally, its efficient mathematical formulation enables reconstructions faster than the time scale of the experiment. This manuscript presents the mathematical model, the inversion strategy and its current experimental implementation. We show characterizations of simulated data as well as experimental data obtained from a synthetic, inorganic model sample: the silica–witherite biomorph. TexTOM provides a versatile framework to reconstruct 3D quantitative texture information for polycrystalline samples; it opens the door for unprecedented insights into the nanostructural makeup of natural and technical materials.
- Open Access
- 25 March 2022
- Published by Springer Nature in Light: Science & Applications
- Vol. 11 (1) , 1-12
4th generation synchrotron source boosts crystalline imaging at the nanoscale
New 4th-generation synchrotron sources, with their increased brilliance, promise to greatly improve the performances of coherent X-ray microscopy. This perspective is of major interest for crystal microscopy, which aims at revealing the 3D crystalline structure of matter at the nanoscale, an approach strongly limited by the available coherent flux. Our results, based on Bragg ptychography experiments performed at the first 4th-generation synchrotron source, demonstrate the possibility of retrieving a high-quality image of the crystalline sample, with unprecedented quality. Importantly, the larger available coherent flux produces datasets with enough information to overcome experimental limitations, such as strongly deteriorated scanning conditions. We show this achievement would not be possible with 3rd-generation sources, a limit that has inhibited the development of this otherwise powerful microscopy method, so far. Hence, the advent of next-generation synchrotron sources not only makes Bragg ptychography suitable for high throughput studies but also strongly relaxes the associated experimental constraints, making it compatible with a wider range of experimental set-ups at the new synchrotrons.
- 25 March 2022
- Published by Springer Nature in Light: Science & Applications
- Vol. 11 (1) , 1-12
Open Access4th generation synchrotron source boosts crystalline imaging at the nanoscale
New 4th-generation synchrotron sources, with their increased brilliance, promise to greatly improve the performances of coherent X-ray microscopy. This perspective is of major interest for crystal microscopy, which aims at revealing the 3D crystalline structure of matter at the nanoscale, an approach strongly limited by the available coherent flux. Our results, based on Bragg ptychography experiments performed at the first 4th-generation synchrotron source, demonstrate the possibility of retrieving a high-quality image of the crystalline sample, with unprecedented quality. Importantly, the larger available coherent flux produces datasets with enough information to overcome experimental limitations, such as strongly deteriorated scanning conditions. We show this achievement would not be possible with 3rd-generation sources, a limit that has inhibited the development of this otherwise powerful microscopy method, so far. Hence, the advent of next-generation synchrotron sources not only makes Bragg ptychography suitable for high throughput studies but also strongly relaxes the associated experimental constraints, making it compatible with a wider range of experimental set-ups at the new synchrotrons.
- Open Access
- 3 December 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-13
Revealing nano-scale lattice distortions in implanted material with 3D Bragg ptychography
Small ion-irradiation-induced defects can dramatically alter material properties and speed up degradation. Unfortunately, most of the defects irradiation creates are below the visibility limit of state-of-the-art microscopy. As such, our understanding of their impact is largely based on simulations with major unknowns. Here we present an x-ray crystalline microscopy approach, able to image with high sensitivity, nano-scale 3D resolution and extended field of view, the lattice strains and tilts in crystalline materials. Using this enhanced Bragg ptychography tool, we study the damage helium-ion-irradiation produces in tungsten, revealing a series of crystalline details in the 3D sample. Our results lead to the conclusions that few-atom-large ‘invisible’ defects are likely isotropic in orientation and homogeneously distributed. A partially defect-denuded region is observed close to a grain boundary. These findings open up exciting perspectives for the modelling of irradiation damage and the detailed analysis of crystalline properties in complex materials.
- 3 December 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-13
Open AccessRevealing nano-scale lattice distortions in implanted material with 3D Bragg ptychography
Small ion-irradiation-induced defects can dramatically alter material properties and speed up degradation. Unfortunately, most of the defects irradiation creates are below the visibility limit of state-of-the-art microscopy. As such, our understanding of their impact is largely based on simulations with major unknowns. Here we present an x-ray crystalline microscopy approach, able to image with high sensitivity, nano-scale 3D resolution and extended field of view, the lattice strains and tilts in crystalline materials. Using this enhanced Bragg ptychography tool, we study the damage helium-ion-irradiation produces in tungsten, revealing a series of crystalline details in the 3D sample. Our results lead to the conclusions that few-atom-large ‘invisible’ defects are likely isotropic in orientation and homogeneously distributed. A partially defect-denuded region is observed close to a grain boundary. These findings open up exciting perspectives for the modelling of irradiation damage and the detailed analysis of crystalline properties in complex materials.
- Open Access
Detector Tilt Considerations in Bragg Coherent Diffraction Imaging: A Simulation Study
This paper addresses the three-dimensional signal distortion and image reconstruction issues in X-ray Bragg coherent diffraction imaging (BCDI) in the event of a general non-orthogonal orientation of the area detector with respect to the diffracted beam. Growing interest in novel BCDI adaptations at fourth-generation synchrotron light sources has necessitated improvisations in the experimental configuration and the subsequent data analysis. One such possibly unavoidable improvisation that is envisioned in this paper is a photon-counting area detector whose face is tilted away from the perpendicular to the Bragg-diffracted beam during the acquisition of the coherent diffraction signal. We describe a likely circumstance in which one would require such a detector configuration, along with the experimental precedent at third-generation synchrotrons. Using physically accurate diffraction simulations from synthetic scatterers in the presence of such tilted detectors, we analyze the general nature of the observed signal distortion qualitatively and quantitatively and provide a prescription to correct for it during image reconstruction. Our simulations and reconstructions are based on an adaptation of the known theory of BCDI sampling geometry, as well as the recently developed projection-based methods of wavefield propagation. Such configurational modifications and their numerical remedies are potentially valuable in realizing unconventional coherent diffraction measurement geometries, eventually paving the way for the integration of BCDI into new material characterization experiments at next-generation light sources.
Open AccessDetector Tilt Considerations in Bragg Coherent Diffraction Imaging: A Simulation Study
This paper addresses the three-dimensional signal distortion and image reconstruction issues in X-ray Bragg coherent diffraction imaging (BCDI) in the event of a general non-orthogonal orientation of the area detector with respect to the diffracted beam. Growing interest in novel BCDI adaptations at fourth-generation synchrotron light sources has necessitated improvisations in the experimental configuration and the subsequent data analysis. One such possibly unavoidable improvisation that is envisioned in this paper is a photon-counting area detector whose face is tilted away from the perpendicular to the Bragg-diffracted beam during the acquisition of the coherent diffraction signal. We describe a likely circumstance in which one would require such a detector configuration, along with the experimental precedent at third-generation synchrotrons. Using physically accurate diffraction simulations from synthetic scatterers in the presence of such tilted detectors, we analyze the general nature of the observed signal distortion qualitatively and quantitatively and provide a prescription to correct for it during image reconstruction. Our simulations and reconstructions are based on an adaptation of the known theory of BCDI sampling geometry, as well as the recently developed projection-based methods of wavefield propagation. Such configurational modifications and their numerical remedies are potentially valuable in realizing unconventional coherent diffraction measurement geometries, eventually paving the way for the integration of BCDI into new material characterization experiments at next-generation light sources.
- Open Access
- 6 March 2020
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 53 (2) , 404-418
General approaches for shear-correcting coordinate transformations in Bragg coherent diffraction imaging. Part II
X-ray Bragg coherent diffraction imaging (BCDI) has been demonstrated as a powerful 3D microscopy approach for the investigation of sub-micrometre-scale crystalline particles. The approach is based on the measurement of a series of coherent Bragg diffraction intensity patterns that are numerically inverted to retrieve an image of the spatial distribution of the relative phase and amplitude of the Bragg structure factor of the diffracting sample. This 3D information, which is collected through an angular rotation of the sample, is necessarily obtained in a non-orthogonal frame in Fourier space that must be eventually reconciled. To deal with this, the approach currently favored by practitioners (detailed in Part I) is to perform the entire inversion in conjugate non-orthogonal real- and Fourier-space frames, and to transform the 3D sample image into an orthogonal frame as a post-processing step for result analysis. In this article, which is a direct follow-up of Part I, two different transformation strategies are demonstrated, which enable the entire inversion procedure of the measured data set to be performed in an orthogonal frame. The new approaches described here build mathematical and numerical frameworks that apply to the cases of evenly and non-evenly sampled data along the direction of sample rotation (i.e. the rocking curve). The value of these methods is that they rely on the experimental geometry, and they incorporate significantly more information about that geometry into the design of the phase-retrieval Fourier transformation than the strategy presented in Part I. Two important outcomes are (1) that the resulting sample image is correctly interpreted in a shear-free frame and (2) physically realistic constraints of BCDI phase retrieval that are difficult to implement with current methods are easily incorporated. Computing scripts are also given to aid readers in the implementation of the proposed formalisms.
- 6 March 2020
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 53 (2) , 404-418
Open AccessGeneral approaches for shear-correcting coordinate transformations in Bragg coherent diffraction imaging. Part II
X-ray Bragg coherent diffraction imaging (BCDI) has been demonstrated as a powerful 3D microscopy approach for the investigation of sub-micrometre-scale crystalline particles. The approach is based on the measurement of a series of coherent Bragg diffraction intensity patterns that are numerically inverted to retrieve an image of the spatial distribution of the relative phase and amplitude of the Bragg structure factor of the diffracting sample. This 3D information, which is collected through an angular rotation of the sample, is necessarily obtained in a non-orthogonal frame in Fourier space that must be eventually reconciled. To deal with this, the approach currently favored by practitioners (detailed in Part I) is to perform the entire inversion in conjugate non-orthogonal real- and Fourier-space frames, and to transform the 3D sample image into an orthogonal frame as a post-processing step for result analysis. In this article, which is a direct follow-up of Part I, two different transformation strategies are demonstrated, which enable the entire inversion procedure of the measured data set to be performed in an orthogonal frame. The new approaches described here build mathematical and numerical frameworks that apply to the cases of evenly and non-evenly sampled data along the direction of sample rotation (i.e. the rocking curve). The value of these methods is that they rely on the experimental geometry, and they incorporate significantly more information about that geometry into the design of the phase-retrieval Fourier transformation than the strategy presented in Part I. Two important outcomes are (1) that the resulting sample image is correctly interpreted in a shear-free frame and (2) physically realistic constraints of BCDI phase retrieval that are difficult to implement with current methods are easily incorporated. Computing scripts are also given to aid readers in the implementation of the proposed formalisms.