Keith Wachowicz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Keith Wachowicz has a total of 166 co-authors. Here are the top co-authors by number of shared publications:
- Bg Gino Fallone
University of Alberta
44 shared publications - Jihyun Yun
Medical Physics Division, Department of Oncology, University of Alberta, 11560 University Avenue, Edmonton, AB T6G 1Z2, Canada
15 shared publications Satyapal Rathee
Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, AB, T6G 1Z2, Canada
8 shared publicationsEugene Yip
Department of Oncology, University of Alberta Cross Cancer Institute Edmonton Alberta Canada
7 shared publicationsZsolt Gabos
Univ Alberta, Cross Canc Inst, Dept Oncol, Edmonton, AB, Canada
7 shared publicationsB Fallone
Cross Cancer Institute, Edmonton, AB
6 shared publications
Latest Publications
- Open Access
- 19 May 2025
- Published by MDPI AG in Algorithms
- Vol. 18 (5) , 290
Quantifying Intra- and Inter-Observer Variabilities in Manual Contours for Radiotherapy: Evaluation of an MR Tumor Autocontouring Algorithm for Liver, Prostate, and Lung Cancer Patients
Real-time tumor-tracked radiotherapy with a linear accelerator-magnetic resonance (linac-MR) hybrid system requires accurate tumor delineation at a fast MR imaging rate. Various autocontouring methods have been previously evaluated against “gold standard” manual contours by experts. However, manually drawn contours have inherent intra- and inter-observer variations. We aim to quantify these variations and evaluate our tumor-autocontouring algorithm against the manual contours. Ten liver, ten prostate, and ten lung cancer patients were scanned using a 3 tesla (T) magnetic resonance imaging (MRI) scanner with a 2D balanced steady-state free precession (bSSFP) sequence at 4 frames/s. Three experts manually contoured the tumor in two sessions. For autocontouring, an in-house built U-Net-based autocontouring algorithm was used, whose hyperparameters were optimized for each patient, expert, and session (PES). For evaluation, (A) Automatic vs. Manual and (B) Manual vs. Manual contour comparisons were performed. For (A) and (B), three types of comparisons were performed: (a) same expert same session, (b) same expert different session, and (c) different experts, using Dice coefficient (DC), centroid displacement (CD), and the Hausdorff distance (HD). For (A), the algorithm was trained using one expert’s contours and its autocontours were compared to contours from (a)–(c). For Automatic vs. Manual evaluations (Aa–Ac), DC = 0.91, 0.86, 0.78, CD = 1.3, 1.8, 2.7 mm, and HD = 3.1, 4.6, 7.0 mm averaged over 30 patients were achieved, respectively. For Manual vs. Manual evaluations (Ba–Bc), DC = 1.00, 0.85, 0.77, CD = 0.0, 2.1, 2.8 mm, and HD = 0.0, 4.9, 7.2 mm were achieved, respectively. We have quantified the intra- and inter-observer variations in manual contouring of liver, prostate, and lung patients. Our PES-specific optimized algorithm generated autocontours with agreement levels comparable to these manual variations, but with high efficiency (54 ms/autocontour vs. 9 s/manual contour).
- 19 May 2025
- Published by MDPI AG in Algorithms
- Vol. 18 (5) , 290
Open AccessQuantifying Intra- and Inter-Observer Variabilities in Manual Contours for Radiotherapy: Evaluation of an MR Tumor Autocontouring Algorithm for Liver, Prostate, and Lung Cancer Patients
Real-time tumor-tracked radiotherapy with a linear accelerator-magnetic resonance (linac-MR) hybrid system requires accurate tumor delineation at a fast MR imaging rate. Various autocontouring methods have been previously evaluated against “gold standard” manual contours by experts. However, manually drawn contours have inherent intra- and inter-observer variations. We aim to quantify these variations and evaluate our tumor-autocontouring algorithm against the manual contours. Ten liver, ten prostate, and ten lung cancer patients were scanned using a 3 tesla (T) magnetic resonance imaging (MRI) scanner with a 2D balanced steady-state free precession (bSSFP) sequence at 4 frames/s. Three experts manually contoured the tumor in two sessions. For autocontouring, an in-house built U-Net-based autocontouring algorithm was used, whose hyperparameters were optimized for each patient, expert, and session (PES). For evaluation, (A) Automatic vs. Manual and (B) Manual vs. Manual contour comparisons were performed. For (A) and (B), three types of comparisons were performed: (a) same expert same session, (b) same expert different session, and (c) different experts, using Dice coefficient (DC), centroid displacement (CD), and the Hausdorff distance (HD). For (A), the algorithm was trained using one expert’s contours and its autocontours were compared to contours from (a)–(c). For Automatic vs. Manual evaluations (Aa–Ac), DC = 0.91, 0.86, 0.78, CD = 1.3, 1.8, 2.7 mm, and HD = 3.1, 4.6, 7.0 mm averaged over 30 patients were achieved, respectively. For Manual vs. Manual evaluations (Ba–Bc), DC = 1.00, 0.85, 0.77, CD = 0.0, 2.1, 2.8 mm, and HD = 0.0, 4.9, 7.2 mm were achieved, respectively. We have quantified the intra- and inter-observer variations in manual contouring of liver, prostate, and lung patients. Our PES-specific optimized algorithm generated autocontours with agreement levels comparable to these manual variations, but with high efficiency (54 ms/autocontour vs. 9 s/manual contour).
- Open Access
- 18 April 2025
- Published by MDPI AG in Algorithms
- Vol. 18 (4) , 233
Patient-Specific Hyperparameter Optimization of a Deep Learning-Based Tumor Autocontouring Algorithm on 2D Liver, Prostate, and Lung Cine MR Images: A Pilot Study
Linear accelerator–magnetic resonance (linac-MR) hybrid systems allow for real-time magnetic resonance imaging (MRI)-guided radiotherapy for more accurate dose delivery to the tumor and improved sparing of the adjacent healthy tissues. However, for real-time tumor detection, it is unfeasible for a human expert to manually contour (gold standard) the tumor at the fast imaging rate of a linac-MR. This study aims to develop a neural network-based tumor autocontouring algorithm with patient-specific hyperparameter optimization (HPO) and to validate its contouring accuracy using in vivo MR images of cancer patients. Two-dimensional (2D) intrafractional MR images were acquired at 4 frames/s using 3 tesla (T) MRI from 11 liver, 24 prostate, and 12 lung cancer patients. A U-Net architecture was applied for tumor autocontouring and was further enhanced by implementing HPO using the Covariance Matrix Adaptation Evolution Strategy. Six hyperparameters were optimized for each patient, for which intrafractional images and experts’ manual contours were input into the algorithm to find the optimal set of hyperparameters. For evaluation, Dice’s coefficient (DC), centroid displacement (CD), and Hausdorff distance (HD) were computed between the manual contours and autocontours. The performance of the algorithm was benchmarked against two standardized autosegmentation methods: non-optimized U-Net and nnU-Net. For the proposed algorithm, the mean (standard deviation) DC, CD, and HD of the 47 patients were 0.92 (0.04), 1.35 (1.03), and 3.63 (2.17) mm, respectively. Compared to the two benchmarking autosegmentation methods, the proposed algorithm achieved the best overall performance in terms of contouring accuracy and speed. This work presents the first tumor autocontouring algorithm applicable to the intrafractional MR images of liver and prostate cancer patients for real-time tumor-tracked radiotherapy. The proposed algorithm performs patient-specific HPO, enabling accurate tumor delineation comparable to that of experts.
- 18 April 2025
- Published by MDPI AG in Algorithms
- Vol. 18 (4) , 233
Open AccessPatient-Specific Hyperparameter Optimization of a Deep Learning-Based Tumor Autocontouring Algorithm on 2D Liver, Prostate, and Lung Cine MR Images: A Pilot Study
Linear accelerator–magnetic resonance (linac-MR) hybrid systems allow for real-time magnetic resonance imaging (MRI)-guided radiotherapy for more accurate dose delivery to the tumor and improved sparing of the adjacent healthy tissues. However, for real-time tumor detection, it is unfeasible for a human expert to manually contour (gold standard) the tumor at the fast imaging rate of a linac-MR. This study aims to develop a neural network-based tumor autocontouring algorithm with patient-specific hyperparameter optimization (HPO) and to validate its contouring accuracy using in vivo MR images of cancer patients. Two-dimensional (2D) intrafractional MR images were acquired at 4 frames/s using 3 tesla (T) MRI from 11 liver, 24 prostate, and 12 lung cancer patients. A U-Net architecture was applied for tumor autocontouring and was further enhanced by implementing HPO using the Covariance Matrix Adaptation Evolution Strategy. Six hyperparameters were optimized for each patient, for which intrafractional images and experts’ manual contours were input into the algorithm to find the optimal set of hyperparameters. For evaluation, Dice’s coefficient (DC), centroid displacement (CD), and Hausdorff distance (HD) were computed between the manual contours and autocontours. The performance of the algorithm was benchmarked against two standardized autosegmentation methods: non-optimized U-Net and nnU-Net. For the proposed algorithm, the mean (standard deviation) DC, CD, and HD of the 47 patients were 0.92 (0.04), 1.35 (1.03), and 3.63 (2.17) mm, respectively. Compared to the two benchmarking autosegmentation methods, the proposed algorithm achieved the best overall performance in terms of contouring accuracy and speed. This work presents the first tumor autocontouring algorithm applicable to the intrafractional MR images of liver and prostate cancer patients for real-time tumor-tracked radiotherapy. The proposed algorithm performs patient-specific HPO, enabling accurate tumor delineation comparable to that of experts.
- Open Access
- 1 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (20) , 205002
A hybrid PCA acceleration method for rapid real-time 2D MRI
Objective. To develop a 2D MR acceleration method utilizing principal component analysis (PCA) in a hybrid fashion for rapid real-time applications. Approach. Retrospective testing was performed on 10 lung, 10 liver and 10 prostate 3T MRI data sets for image quality and target contourability. Sampling of k-space is performed by acquiring central (low-frequency) data in every frame while the high-frequency data is incoherently undersampled such that all of k-space is acquired in a pre-determined number of frames. Firstly, principal components (PCs) representative of intra-frame correlations between central and outer k-space data are used to estimate unsampled data in the frame of interest. Then to add further stability, PCs representative of time-domain fluctuations within a reconstruction window of the most recent frames are fit to outer k-space data (including above estimations) to obtain final estimates in the frame of interest. Accelerated reconstructions between 3x and 8x were tested for image quality and contourability along with the optimal number of PCs for fitting. Main results. It was found that at higher acceleration rates, image quality did not deteriorate significantly. Similarly, it was found that the images were of sufficient quality to contour a target using auto-contouring software at all tested acceleration rates and sites. SSIM values were found to be ⩾0.91 at all accelerations tested. Similarly dice coefficients at the different sites were found to be ⩾0.89 even at 8x accelerations which is on par with or better than intra-observer variation. Significance. This method appears to produce improved image quality and contourability compared to previous PCA methods while also allowing a greater number of PCs to be used in reconstruction. The method can be run using a simple single-channel coil and does not require significant computing power to meet real-time interventional standards (reconstruction times ∼60 ms/frame on Intel i5 CPU).
- 1 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (20) , 205002
Open AccessA hybrid PCA acceleration method for rapid real-time 2D MRI
Objective. To develop a 2D MR acceleration method utilizing principal component analysis (PCA) in a hybrid fashion for rapid real-time applications. Approach. Retrospective testing was performed on 10 lung, 10 liver and 10 prostate 3T MRI data sets for image quality and target contourability. Sampling of k-space is performed by acquiring central (low-frequency) data in every frame while the high-frequency data is incoherently undersampled such that all of k-space is acquired in a pre-determined number of frames. Firstly, principal components (PCs) representative of intra-frame correlations between central and outer k-space data are used to estimate unsampled data in the frame of interest. Then to add further stability, PCs representative of time-domain fluctuations within a reconstruction window of the most recent frames are fit to outer k-space data (including above estimations) to obtain final estimates in the frame of interest. Accelerated reconstructions between 3x and 8x were tested for image quality and contourability along with the optimal number of PCs for fitting. Main results. It was found that at higher acceleration rates, image quality did not deteriorate significantly. Similarly, it was found that the images were of sufficient quality to contour a target using auto-contouring software at all tested acceleration rates and sites. SSIM values were found to be ⩾0.91 at all accelerations tested. Similarly dice coefficients at the different sites were found to be ⩾0.89 even at 8x accelerations which is on par with or better than intra-observer variation. Significance. This method appears to produce improved image quality and contourability compared to previous PCA methods while also allowing a greater number of PCs to be used in reconstruction. The method can be run using a simple single-channel coil and does not require significant computing power to meet real-time interventional standards (reconstruction times ∼60 ms/frame on Intel i5 CPU).
- 21 March 2024
- Published by Springer Nature
- p. 193-215
The Alberta Rotating Biplanar Linac-MR, a.k.a., Aurora-RT™
- 21 March 2024
- Published by Springer Nature
- p. 193-215
The Alberta Rotating Biplanar Linac-MR, a.k.a., Aurora-RT™
- 30 October 2021
- Published by Springer Nature in European Spine Journal
- Vol. 31 (8) , 1979-1991
Use of machine learning to select texture features in investigating the effects of axial loading on T2-maps from magnetic resonance imaging of the lumbar discs
Background Recent advances in texture analysis and machine learning offer new opportunities to improve the application of imaging to intervertebral disc biomechanics. This study employed texture analysis and machine learning on MRIs to investigate the lumbar disc’s response to loading. Methods Thirty-five volunteers (30 (SD 11) yrs.) with and without chronic back pain spent 20 min lying in a relaxed unloaded supine position, followed by 20 min loaded in compression, and then 20 min with traction applied. T2-weighted MR images were acquired during the last 5 min of each loading condition. Custom image analysis software was used to segment discs from adjacent tissues semi-automatically and segment each disc into the nucleus, anterior and posterior annulus automatically. A grey-level, co-occurrence matrix with one to four pixels offset in four directions (0°, 45°, 90° and 135°) was then constructed (320 feature/tissue). The Random Forest Algorithm was used to select the most promising classifiers. Linear mixed-effect models and Cohen’s d compared loading conditions. Findings All statistically significant differences (p < 0.001) were observed in the nucleus and posterior annulus in the 135° offset direction at the L4-5 level between lumbar compression and traction. Correlation (P2-Offset, P4-Offset) and information measure of correlation 1 (P3-Offset, P4-Offset) detected significant changes in the nucleus. Statistically significant changes were also observed for homogeneity (P2-Offset, P3-Offset), contrast (P2-Offset), and difference variance (P4-Offset) of the posterior annulus. Interpretation MRI textural features may have the potential of identifying the disc's response to loading, particularly in the nucleus and posterior annulus, which appear most sensitive to loading. Level of evidence Diagnostic: individual cross-sectional studies with consistently applied reference standard and blinding
- 30 October 2021
- Published by Springer Nature in European Spine Journal
- Vol. 31 (8) , 1979-1991
Use of machine learning to select texture features in investigating the effects of axial loading on T2-maps from magnetic resonance imaging of the lumbar discs
Background Recent advances in texture analysis and machine learning offer new opportunities to improve the application of imaging to intervertebral disc biomechanics. This study employed texture analysis and machine learning on MRIs to investigate the lumbar disc’s response to loading. Methods Thirty-five volunteers (30 (SD 11) yrs.) with and without chronic back pain spent 20 min lying in a relaxed unloaded supine position, followed by 20 min loaded in compression, and then 20 min with traction applied. T2-weighted MR images were acquired during the last 5 min of each loading condition. Custom image analysis software was used to segment discs from adjacent tissues semi-automatically and segment each disc into the nucleus, anterior and posterior annulus automatically. A grey-level, co-occurrence matrix with one to four pixels offset in four directions (0°, 45°, 90° and 135°) was then constructed (320 feature/tissue). The Random Forest Algorithm was used to select the most promising classifiers. Linear mixed-effect models and Cohen’s d compared loading conditions. Findings All statistically significant differences (p < 0.001) were observed in the nucleus and posterior annulus in the 135° offset direction at the L4-5 level between lumbar compression and traction. Correlation (P2-Offset, P4-Offset) and information measure of correlation 1 (P3-Offset, P4-Offset) detected significant changes in the nucleus. Statistically significant changes were also observed for homogeneity (P2-Offset, P3-Offset), contrast (P2-Offset), and difference variance (P4-Offset) of the posterior annulus. Interpretation MRI textural features may have the potential of identifying the disc's response to loading, particularly in the nucleus and posterior annulus, which appear most sensitive to loading. Level of evidence Diagnostic: individual cross-sectional studies with consistently applied reference standard and blinding
- 15 September 2021
- Published by Wiley in Medical Physics
- Vol. 48 (11) , 6724-6739
Time domain principal component analysis for rapid, real‐time 2D MRI reconstruction from undersampled data
Purpose: A rapid real‐time 2D accelerated method was developed for magnetic resonance imaging (MRI) using principal component analysis (PCA) in the temporal domain. This method employs a moving window of previous dynamic frames to reconstruct the current, real‐time frame within this window. This technique could be particularly useful in real‐time tracking applications such as in MR‐guided radiotherapy, where low latency real‐time reconstructions are essential.Methods: The method was tested retrospectively on 15 fully‐sampled data sets of lung patient data acquired on a 3T Philips Achieva system. High frequency data are incoherently undersampled, while the central low‐frequency data are always acquired to characterize the temporal fluctuations through PCA. The undersampling pattern is derived in such a way that all of k‐space is acquired within a pre‐determined number of frames. The missing data in the current frame are then filled in by fitting the temporal characterizations to the acquired undersampled data, using a pre‐determined number of PCs. A subset of six patients was used to test the contour ability of the images. Various accelerations between 3x and 8x were tested along with the optimal number of PCs for fitting. A comparison was also performed with previous work from our group proposed by Dietz et al. as well as with a standard low resolution acquisition. In order to determine how the method would perform at lower signal to noise ratio (SNR), noise levels of 2×, 4×, and 6× were added to the 3T data. Metrics such as normalised mean square error and Dice coefficient were used to measure the reconstruction image quality and contour ability.Results: The proposed method demonstrated good temporal robustness as consistent metrics were detected for the duration of the imaging session. It was found that the optimal number of PCs for temporal fitting was dependent on the acceleration rate. For the data tested, five PCs were found to be optimal at the acceleration rates of 3× and 4×. This number decreases to three at accelerations of 5× and 6× and further decreases to two at an acceleration rate of 8×, likely due to greater instability with fewer acquired data points. The use of too many PCs for fitting increased the chances of noisy reconstruction which affected contourability.Conclusions: The proposed 2D real‐time MR acceleration method demonstrated greater robustness in the metrics over time when compared with previous real‐time PCA methods using metrics such as normalised mean squared error, peak SNR and structural similarity up to an acceleration of 8x. Improved temporal robustness of image structure contourability and accurate definition was also demonstrated using several metrics including the Dice coefficient. Reconstruction of raw acquired data can be performed at approximately 50 ms per frame using an Intel core i5 CPU. The method has the advantage of being very flexible in terms of hardware requirements as it can operate successfully on a single coil channel and does not require specialized computing power to implement in real‐time.
- 15 September 2021
- Published by Wiley in Medical Physics
- Vol. 48 (11) , 6724-6739
Time domain principal component analysis for rapid, real‐time 2D MRI reconstruction from undersampled data
Purpose: A rapid real‐time 2D accelerated method was developed for magnetic resonance imaging (MRI) using principal component analysis (PCA) in the temporal domain. This method employs a moving window of previous dynamic frames to reconstruct the current, real‐time frame within this window. This technique could be particularly useful in real‐time tracking applications such as in MR‐guided radiotherapy, where low latency real‐time reconstructions are essential.Methods: The method was tested retrospectively on 15 fully‐sampled data sets of lung patient data acquired on a 3T Philips Achieva system. High frequency data are incoherently undersampled, while the central low‐frequency data are always acquired to characterize the temporal fluctuations through PCA. The undersampling pattern is derived in such a way that all of k‐space is acquired within a pre‐determined number of frames. The missing data in the current frame are then filled in by fitting the temporal characterizations to the acquired undersampled data, using a pre‐determined number of PCs. A subset of six patients was used to test the contour ability of the images. Various accelerations between 3x and 8x were tested along with the optimal number of PCs for fitting. A comparison was also performed with previous work from our group proposed by Dietz et al. as well as with a standard low resolution acquisition. In order to determine how the method would perform at lower signal to noise ratio (SNR), noise levels of 2×, 4×, and 6× were added to the 3T data. Metrics such as normalised mean square error and Dice coefficient were used to measure the reconstruction image quality and contour ability.Results: The proposed method demonstrated good temporal robustness as consistent metrics were detected for the duration of the imaging session. It was found that the optimal number of PCs for temporal fitting was dependent on the acceleration rate. For the data tested, five PCs were found to be optimal at the acceleration rates of 3× and 4×. This number decreases to three at accelerations of 5× and 6× and further decreases to two at an acceleration rate of 8×, likely due to greater instability with fewer acquired data points. The use of too many PCs for fitting increased the chances of noisy reconstruction which affected contourability.Conclusions: The proposed 2D real‐time MR acceleration method demonstrated greater robustness in the metrics over time when compared with previous real‐time PCA methods using metrics such as normalised mean squared error, peak SNR and structural similarity up to an acceleration of 8x. Improved temporal robustness of image structure contourability and accurate definition was also demonstrated using several metrics including the Dice coefficient. Reconstruction of raw acquired data can be performed at approximately 50 ms per frame using an Intel core i5 CPU. The method has the advantage of being very flexible in terms of hardware requirements as it can operate successfully on a single coil channel and does not require specialized computing power to implement in real‐time.
- Open Access
- 30 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 95294-95303
A Short and Light, Sparse Dipolar Halbach Magnet for MRI
Recently designed dipolar Halbach magnets used in portable MRI systems are much lighter and more compact than standard permanent or superconductive magnets. However, improved designs and manufacturing techniques aiming at lower weight and smaller external size are an area of continual interest especially for application to space flight. Most Halbach magnet design techniques aim to optimize homogeneity suitable for MRI over a diameter-spherical volume (DSV) that requires the aspect ratio (length/inner diameter) to be larger than 1.5:1. Furthermore, current magnet construction techniques often use low-coercivity magnetic pieces and imperfect formers that produce a mismatch in the intended designs. As a result, Halbach magnets require complex shimming methods to improve the magnetic field homogeneity, causing further size and weight increase. Here, we propose to reduce the weight and the aspect ratio of the Halbach magnet by optimizing homogeneity over a cylindrical region of interest (ROI) rather than a DSV, applying a genetic algorithm, high-coercivity ferromagnets (N40UH) and a robust construction technique. The assembled 67 mT magnet, with aspect ratio ~ 1:1, produces almost identical homogeneity (11152 ppm) as simulations (11451 ppm) within a 12.7 cm diameter, 1 cm long cylinder ROI. The magnet structure was 3D printed ring-by-ring and assembled coaxially. The magnet can be disassembled for transportation.
- 30 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 95294-95303
Open AccessA Short and Light, Sparse Dipolar Halbach Magnet for MRI
Recently designed dipolar Halbach magnets used in portable MRI systems are much lighter and more compact than standard permanent or superconductive magnets. However, improved designs and manufacturing techniques aiming at lower weight and smaller external size are an area of continual interest especially for application to space flight. Most Halbach magnet design techniques aim to optimize homogeneity suitable for MRI over a diameter-spherical volume (DSV) that requires the aspect ratio (length/inner diameter) to be larger than 1.5:1. Furthermore, current magnet construction techniques often use low-coercivity magnetic pieces and imperfect formers that produce a mismatch in the intended designs. As a result, Halbach magnets require complex shimming methods to improve the magnetic field homogeneity, causing further size and weight increase. Here, we propose to reduce the weight and the aspect ratio of the Halbach magnet by optimizing homogeneity over a cylindrical region of interest (ROI) rather than a DSV, applying a genetic algorithm, high-coercivity ferromagnets (N40UH) and a robust construction technique. The assembled 67 mT magnet, with aspect ratio ~ 1:1, produces almost identical homogeneity (11152 ppm) as simulations (11451 ppm) within a 12.7 cm diameter, 1 cm long cylinder ROI. The magnet structure was 3D printed ring-by-ring and assembled coaxially. The magnet can be disassembled for transportation.
- 1 December 2020
- Published by Elsevier in Musculoskeletal Science and Practice
- Vol. 50, 102250
Could compression and traction loading improve the ability of magnetic resonance imaging to identify findings related to low back pain?
- 1 December 2020
- Published by Elsevier in Musculoskeletal Science and Practice
- Vol. 50, 102250
Could compression and traction loading improve the ability of magnetic resonance imaging to identify findings related to low back pain?
- 15 October 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 2327-2333
How thin can you go? Performance of thin copper and aluminum RF coil conductors
Purpose: To evaluate the impact of emerging conductor technology on RF coils. Performance and resulting image quality of thin or alternate conductors (eg, aluminum instead of copper) and thicknesses (9‐600 μm) are compared in terms of SNR.Methods: Eight prototype RF coils (15 cm × 15 cm square loops) were constructed and bench‐tested to measure quality factor. The coils used 6‐mm‐wide conducting strips of either copper or aluminum of a few different thicknesses (copper: 17, 32, 35, 127, 600 μm; aluminum: 9, 13, 20, 127 μm) on acetate projector sheets for backing. Corresponding image SNR was measured at 0.48 tesla (20.56 MHz).Results: The coils spanned a range of unloaded quality factors from 89 to 390 and a fivefold range of losses. The image SNRs were consistent with the coils’ bench‐measured efficiencies (0.33‐0.73). Thin aluminum conductors (9 μm) led to the highest reduction in SNR (65% that of 127 μm copper). Thin copper (<32 μm) conductors lead to a much smaller decrease in SNR (approximately 10%) compared to 127 μm copper. No performance difference was observed between 127 μm thick copper and aluminum. The much thicker 600 μm copper bars only yield a 5% improvement in SNR.Conclusion: Even at 0.48 tesla, copper RF coil conductors much thinner than those in conventional construction can be used while maintaining SNR greater than 50% that of thick copper. These emerging coil conductor technologies enable RF coil functionality that cannot be achieved otherwise.
- 15 October 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 2327-2333
How thin can you go? Performance of thin copper and aluminum RF coil conductors
Purpose: To evaluate the impact of emerging conductor technology on RF coils. Performance and resulting image quality of thin or alternate conductors (eg, aluminum instead of copper) and thicknesses (9‐600 μm) are compared in terms of SNR.Methods: Eight prototype RF coils (15 cm × 15 cm square loops) were constructed and bench‐tested to measure quality factor. The coils used 6‐mm‐wide conducting strips of either copper or aluminum of a few different thicknesses (copper: 17, 32, 35, 127, 600 μm; aluminum: 9, 13, 20, 127 μm) on acetate projector sheets for backing. Corresponding image SNR was measured at 0.48 tesla (20.56 MHz).Results: The coils spanned a range of unloaded quality factors from 89 to 390 and a fivefold range of losses. The image SNRs were consistent with the coils’ bench‐measured efficiencies (0.33‐0.73). Thin aluminum conductors (9 μm) led to the highest reduction in SNR (65% that of 127 μm copper). Thin copper (<32 μm) conductors lead to a much smaller decrease in SNR (approximately 10%) compared to 127 μm copper. No performance difference was observed between 127 μm thick copper and aluminum. The much thicker 600 μm copper bars only yield a 5% improvement in SNR.Conclusion: Even at 0.48 tesla, copper RF coil conductors much thinner than those in conventional construction can be used while maintaining SNR greater than 50% that of thick copper. These emerging coil conductor technologies enable RF coil functionality that cannot be achieved otherwise.
- 29 November 2018
- Published by Wiley in Medical Physics
- Vol. 46 (2) , 822-838
Proton beam behavior in a parallel configured MRI‐proton therapy hybrid: Effects of time‐varying gradient magnetic fields
Purpose: Real‐time magnetic resonance (MR) guidance is of interest to various groups globally because the superior soft tissue contrast MR images offer over other x‐ray‐based imaging modalities. Because of the precision required in proton therapy, proton therapy treatments rely heavily on image guidance. Integrating a magnetic resonance imaging (MRI) into a proton therapy treatment is a challenge. The charged particles (protons) used in proton therapy experience magnetic forces when travelling through the MRI magnetic fields. Given that it is desired that proton beams can be delivered with submillimeter accuracy, it is important that all potential sources of beam displacement are well modeled and understood. This study investigated the behavior of monoenergetic proton beams in the presence of a simulated set of realistic three‐dimensional (3D) vector magnetic gradient fields required for spatial localization during imaging. This deflecting source has not been previously investigated.Methods: Three‐dimensional magnetic vector fields from a superconducting 0.5 T open bore MRI magnet model (previously developed in‐house) and 3D magnetic fields from an in‐house gradient coil model were applied to two types of computer simulations. In all simulations, monoenergetic proton pencil beams (from 80 to 250 MeV) were used. The initial directions of proton beams were varied. In all simulations, the orientation of the B0 field coincided with the positive z‐axis in the simulation geometry. The first type of simulation is based on an analytic magnetic force equation (analytic simulations) while the second type is a full Monte Carlo (MC) simulation. The analytic simulations were limited to propagating the proton beams in vacuum but could be rapidly calculated in a desktop computer while the MC simulations were calculated in a cluster computer. The proton beam locations and dose profiles at the central plane (z = 0 cm) with or without magnetic fields were extracted and used to quantify the effect of the presence of the different magnetic fields on the proton beam.Results: The analytic simulations agree with MC results within 0.025 mm, thus acting as the verification of MC calculations. The presence of the B0 field caused the beam to follow a helical trajectory which resulted in angular offsets of 4.9o, 3.6o, and 2.8o for the 80, 150, and 250 MeV, respectively. Magnetic field deflections caused by a rapid MRI sequence (bSSFP, with maximum gradient strength of 40 mT/m) show a pattern of distortion which remained spatially invariant in the MR's field of view. For the 80 MeV beam, this pattern shows a maximum ranged in the y direction of 1.5 mm. The presence of the B0 field during the bSSFP simulations adds the same beam rotation to the observed during the B0 only simulations.Conclusion: This investigation reveals that time‐varying gradient magnetic fields required for image generation can cause a small spread in the proton beams used in the study which are independent of the effects arising from the B0 field. Further, studies where clinical beam kernels were convolved with this spread show that these magnetic fields are expected to have an insignificant impact on the beam's entrance dose.
- 29 November 2018
- Published by Wiley in Medical Physics
- Vol. 46 (2) , 822-838
Proton beam behavior in a parallel configured MRI‐proton therapy hybrid: Effects of time‐varying gradient magnetic fields
Purpose: Real‐time magnetic resonance (MR) guidance is of interest to various groups globally because the superior soft tissue contrast MR images offer over other x‐ray‐based imaging modalities. Because of the precision required in proton therapy, proton therapy treatments rely heavily on image guidance. Integrating a magnetic resonance imaging (MRI) into a proton therapy treatment is a challenge. The charged particles (protons) used in proton therapy experience magnetic forces when travelling through the MRI magnetic fields. Given that it is desired that proton beams can be delivered with submillimeter accuracy, it is important that all potential sources of beam displacement are well modeled and understood. This study investigated the behavior of monoenergetic proton beams in the presence of a simulated set of realistic three‐dimensional (3D) vector magnetic gradient fields required for spatial localization during imaging. This deflecting source has not been previously investigated.Methods: Three‐dimensional magnetic vector fields from a superconducting 0.5 T open bore MRI magnet model (previously developed in‐house) and 3D magnetic fields from an in‐house gradient coil model were applied to two types of computer simulations. In all simulations, monoenergetic proton pencil beams (from 80 to 250 MeV) were used. The initial directions of proton beams were varied. In all simulations, the orientation of the B0 field coincided with the positive z‐axis in the simulation geometry. The first type of simulation is based on an analytic magnetic force equation (analytic simulations) while the second type is a full Monte Carlo (MC) simulation. The analytic simulations were limited to propagating the proton beams in vacuum but could be rapidly calculated in a desktop computer while the MC simulations were calculated in a cluster computer. The proton beam locations and dose profiles at the central plane (z = 0 cm) with or without magnetic fields were extracted and used to quantify the effect of the presence of the different magnetic fields on the proton beam.Results: The analytic simulations agree with MC results within 0.025 mm, thus acting as the verification of MC calculations. The presence of the B0 field caused the beam to follow a helical trajectory which resulted in angular offsets of 4.9o, 3.6o, and 2.8o for the 80, 150, and 250 MeV, respectively. Magnetic field deflections caused by a rapid MRI sequence (bSSFP, with maximum gradient strength of 40 mT/m) show a pattern of distortion which remained spatially invariant in the MR's field of view. For the 80 MeV beam, this pattern shows a maximum ranged in the y direction of 1.5 mm. The presence of the B0 field during the bSSFP simulations adds the same beam rotation to the observed during the B0 only simulations.Conclusion: This investigation reveals that time‐varying gradient magnetic fields required for image generation can cause a small spread in the proton beams used in the study which are independent of the effects arising from the B0 field. Further, studies where clinical beam kernels were convolved with this spread show that these magnetic fields are expected to have an insignificant impact on the beam's entrance dose.