RFRobert Neil Finnegan

Robert Neil Finnegan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert Neil Finnegan has a total of 93 co-authors. Here are the top co-authors by number of shared publications:

  • David Thwaites

    Institute of Medical Physics, School of Physics, The University of Sydney, Sydney, New South Wales, Australia

    4 shared publications
  • Jason Dowling

    Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia

    4 shared publications
  • Lois Holloway

    Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia

    4 shared publications
  • Ebbe Laugaard Lorenzen

    Department of Clinical Research, University of Southern Denmark, Denmark; Laboratory of Radiation Physics, Department of Oncology, Odense University Hospital, Denmark

    3 shared publications
  • Geoffrey Paul Delaney

    Collaboration for Cancer Outcomes Research and Evaluation (CCORE), School of Clinical Medicine University of New South Wales (UNSW) Sydney Australia

    3 shared publications
  • Jason Dowling

    Commonwealth Scientific and Industrial Research Organisation, Australian E-Health Research Centre, Herston, QLD 4029, Australia

    3 shared publications

Latest Publications

  • Open Access

    Geometric and dosimetric evaluation of a commercial AI auto‐contouring tool on multiple anatomical sites in CT scans

    by Robert N. Finnegan, Alexandra Quinn, Patrick Horsley, Joseph Chan, Maegan Stewart, Regina Bromley, Jeremy Booth

    Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into clinical workflows. This retrospective study included 223 patients with treatment sites in the pelvis, abdomen, thorax, and head and neck regions. The Ethos AI tool generated auto‐contours on each patients’ pre‐treatment planning CT, and 45 unique structures were included across the study cohort. Multiple measures of geometric similarity were computed, including surface Dice Similarity Coefficient (sDSC) and mean distance to agreement (MDA). Dosimetric concordance was evaluated by comparing mean dose and maximum 2 cm3 dose (D2 cc) between manual and AI contours. Ethos AI demonstrated high geometric accuracy for well‐defined structures like the bladder, lungs, and femoral heads. Smaller structures and those with less defined boundaries, such as optic nerves and duodenum, showed lower agreement. Over 70% of auto‐contours demonstrated a sDSC > 0.8, and 74% had MDA < 2.5 mm. Geometric accuracy generally correlated with dosimetric concordance, however differences in contour definitions did result in some structures exhibiting dose deviations. The Ethos AI auto‐contouring tool offers promising accuracy and reliability for many anatomical structures, supporting its use in planning workflows. Auto‐contouring errors, although rare, highlight the importance of ongoing QA and expert manual oversight.


  • Open Access

    Overview of cardiac toxicity from radiation therapy

    by Vicky Chin, Robert N Finnegan, Paul Keall, James Otton, Geoff P Delaney, Shalini K Vinod

    Radiotherapy is an essential part of treatment for many patients with thoracic cancers. However, proximity of the heart to tumour targets can lead to cardiac side effects, with studies demonstrating link between cardiac radiation dose and adverse outcomes. Although reducing cardiac dose can reduce associated risks, most cardiac constraint recommendations in clinical use are generally based on dose to the whole heart, as dose assessment at cardiac substructure levels on individual patients has been limited historically. Furthermore, estimation of an individual's cardiac risk is complex and multifactorial, which includes radiation dose alongside baseline risk factors, and the impact of systemic therapies. This review gives an overview of the epidemiological impact of cancer and cardiac disease, risk factors contributing to radiation‐related cardiotoxicity, the evidence for cardiac side effects and future directions in cardiotoxicity research. A better understanding of the interactions between risk factors, balancing treatment benefit versus toxicity and the ongoing management of cardiac risk is essential for optimal clinical care. The emerging field of cardio‐oncology is thus a multidisciplinary collaborative effort to enable better understanding of cardiac risks and outcomes for better‐informed patient management decisions.


  • Open Access

    Cardiac substructure delineation in radiation therapy – A state‐of‐the‐art review

    by Robert N Finnegan, Alexandra Quinn, Jeremy Booth, Gregg Belous, Nicholas Hardcastle, Maegan Stewart, Brooke Griffiths, Susan Carroll, David I Thwaites

    Summary: Delineation of cardiac substructures is crucial for a better understanding of radiation‐related cardiotoxicities and to facilitate accurate and precise cardiac dose calculation for developing and applying risk models. This review examines recent advancements in cardiac substructure delineation in the radiation therapy (RT) context, aiming to provide a comprehensive overview of the current level of knowledge, challenges and future directions in this evolving field. Imaging used for RT planning presents challenges in reliably visualising cardiac anatomy. Although cardiac atlases and contouring guidelines aid in standardisation and reduction of variability, significant uncertainties remain in defining cardiac anatomy. Coupled with the inherent complexity of the heart, this necessitates auto‐contouring for consistent large‐scale data analysis and improved efficiency in prospective applications. Auto‐contouring models, developed primarily for breast and lung cancer RT, have demonstrated performance comparable to manual contouring, marking a significant milestone in the evolution of cardiac delineation practices. Nevertheless, several key concerns require further investigation. There is an unmet need for expanding cardiac auto‐contouring models to encompass a broader range of cancer sites. A shift in focus is needed from ensuring accuracy to enhancing the robustness and accessibility of auto‐contouring models. Addressing these challenges is paramount for the integration of cardiac substructure delineation and associated risk models into routine clinical practice, thereby improving the safety of RT for future cancer patients.


  • Open Access

    Dosimetric Impact of Delineation and Motion Uncertainties on the Heart and Substructures in Lung Cancer Radiotherapy

    by V. Chin, R N Finnegan, P. Chlap, L. Holloway, D.I. Thwaites, J. Otton, G.P. Delaney, S.K. Vinod


  • Open Access

    An open source auto-segmentation algorithm for delineating heart and substructures – Development and validation within a multicenter lung cancer cohort

    by Agon Olloni, Ebbe Laugaard Lorenzen, Stefan Starup Jeppesen, Axel Diederichsen, Robert Finnegan, Lone Hoffmann, Charlotte Kristiansen, Marianne Knap, Marie Louise Holm Milo, Ditte Sloth Møller, et al.


  • Open Access

    PlatiPy: Processing Library and Analysis Toolkit for Medical Imaging in Python

    by Phillip Chlap, Robert N. Finnegan

    PlatiPy offers a comprehensive suite of tools and utilities for conducting medical image analysis research utilising Python. These tools include functions for converting data between the clinical standard DICOM format and the research-friendly NIfTI format, capabilities for image registration and atlas-based segmentation, and efficient image visualisation tools to facilitate rapid development in research. Additionally, the library includes auto-segmentation models developed through various research projects enabling their streamlined deployment for use in future projects by the research community.


  • Open Access

    Open-source, fully-automated hybrid cardiac substructure segmentation: development and optimisation

    by Robert N. Finnegan, Vicky Chin, Phillip Chlap, Ali Haidar, James Otton, Jason Dowling, David I. Thwaites, Shalini K. Vinod, Geoff P. Delaney, Lois Holloway

    Radiotherapy for thoracic and breast tumours is associated with a range of cardiotoxicities. Emerging evidence suggests cardiac substructure doses may be more predictive of specific outcomes, however, quantitative data necessary to develop clinical planning constraints is lacking. Retrospective analysis of patient data is required, which relies on accurate segmentation of cardiac substructures. In this study, a novel model was designed to deliver reliable, accurate, and anatomically consistent segmentation of 18 cardiac substructures on computed tomography (CT) scans. Thirty manually contoured CT scans were included. The proposed multi-stage method leverages deep learning (DL), multi-atlas mapping, and geometric modelling to automatically segment the whole heart, cardiac chambers, great vessels, heart valves, coronary arteries, and conduction nodes. Segmentation performance was evaluated using the Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD), and volume ratio. Performance was reliable, with no errors observed and acceptable variation in accuracy between cases, including in challenging cases with imaging artefacts and atypical patient anatomy. The median DSC range was 0.81–0.93 for whole heart and cardiac chambers, 0.43–0.76 for great vessels and conduction nodes, and 0.22–0.53 for heart valves. For all structures the median MDA was below 6 mm, median HD ranged 7.7–19.7 mm, and median volume ratio was close to one (0.95–1.49) for all structures except the left main coronary artery (2.07). The fully automatic algorithm takes between 9 and 23 min per case. The proposed fully-automatic method accurately delineates cardiac substructures on radiotherapy planning CT scans. Robust and anatomically consistent segmentations, particularly for smaller structures, represents a major advantage of the proposed segmentation approach. The open-source software will facilitate more precise evaluation of cardiac doses and risks from available clinical datasets. Graphical


  • Open Access

    A statistical, voxelised model of prostate cancer for biologically optimised radiotherapy

    by Robert N Finnegan, Hayley M Reynolds, Martin A Ebert, Yu Sun, Lois Holloway, Jonathan R Sykes, Jason Dowling, Catherine Mitchell, Scott G Williams, Declan G Murphy, et al.


  • Validation of a new open-source method for automatic delineation and dose assessment of the heart and LADCA in breast radiotherapy with simultaneous uncertainty estimation

    by Robert Neil Finnegan, Ebbe Laugaard Lorenzen, Jason Dowling, David Thwaites, Geoff Delaney, Carsten Brink, Lois Holloway

    Radiotherapy has been shown to increase risks of cardiotoxicities for breast cancer patients. Automated delineation approaches are necessary for consistent and efficient assessment of cardiac doses in large, retrospective datasets, while patient-specific estimation of the uncertainty in these doses provides valuable additional data for modelling and understanding risks. In this work, we aim to validate the consistency of our previously described open-source software model for automatic cardiac delineation in the context of dose assessment, relative to manual contouring. We also extend our software to introduce a novel method to automatically quantify the uncertainty in cardiac doses based on expected inter-observer variability (IOV) in contouring. This method was applied to a cohort of 15 left-sided breast cancer patients treated in Denmark using modern tangential radiotherapy techniques. On each image set, the whole heart and left anterior descending coronary artery (LADCA) were contoured by nine independent experts; the range of doses to these nine volumes provided a reference for the dose uncertainties generated from the automatic method. Local and external atlas sets were used to test the method. Results give confidence in the consistency of automatic segmentations, with mean whole heart dose differences for local and external atlas sets of −0.20 ± 0.17 and −0.10 ± 0.14 Gy, respectively. Automatic estimates of uncertainties in doses are similar to those from IOV for both the whole heart and LADCA. Overall, this study confirms that our automated approach can be used to accurately assess cardiac doses, and the proposed method can provide a useful tool in estimating dose uncertainties.


  • Open Access

    Feasibility of using a novel automatic cardiac segmentation algorithm in the clinical routine of lung cancer patients

    by Robert Neil Finnegan, Lucia Orlandini, Xiongfei Liao, Jun Yin, Jinyi Lang, Jason Dowling, Davide Fontanarosa

    Incidental radiation exposure to the heart during lung cancer radiotherapy is associated with radiation-induced heart disease and increased rates of mortality. By considering the respiratory-induced motion of the heart it is possible to create a radiotherapy plan that results in a lower overall cardiac dose. This approach is challenging using current clinical practices: manual contouring of the heart is time consuming, and subject to inter- and intra-observer variability. In this work, we investigate the feasibility of our previously developed, atlas-based, automatic heart segmentation tool to delineate the heart in four-dimensional x-ray computed tomography (4D-CT) images. We used a dataset comprising 19 patients receiving radiotherapy for lung cancer, with 4D-CT imaging acquired at 10 respiratory phases and with a maximum intensity projection image generated from these. For each patient, one of four experienced radiation oncologists contoured the heart on each respiratory phase image and the maximum intensity image. Automatic segmentation of the heart on these same patient image sets was achieved using a leave-one-out approach, where for each patient the remaining 18 were used as an atlas set. The consistency of the automatic segmentation relative to manual contouring was evaluated using the Dice similarity coefficient (DSC) and mean absolute surface-to-surface distance (MASD). The DSC and MASD are comparable to inter-observer variability in clinically acceptable whole heart delineations (average DSC > 0.93 and average MASD < 2.0 mm in all the respiratory phases). The comparison between automatic and manual delineations on the maximum intensity images produced an overall mean DSC of 0.929 and a mean MASD of 2.07 mm. The automatic, atlas-based segmentation tool produces clinically consistent and robust heart delineations and is easy to implement in the routine care of lung cancer patients.