K. Sandek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
K. Sandek has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
L. Lagerstrand
Department of Clinical Physiology, Karolinska Institutet at Huddinge University Hospital, Stockholm, Sweden
4 shared publicationsT. Bratel
Division of Respiratory and Allergic Diseases, Department of Medicine, Karolinska Institutet at Huddinge University Hospital, Stockholm, Sweden
4 shared publicationsG. Hellström
Division of Medical Engineering, Department of Medical Laboratory Sciences and Technology, Karolinska Institutet at Huddinge University Hospital, Stockholm, Sweden
2 shared publicationsT. Andersson
2 shared publicationsB Mossberg
1 shared publicationH Rosell
Department of Diagnostics Radiology, Karolinska Institutet at Huddinge University Hospital, Stockholm, Sweden
1 shared publication
Latest Publications
- 1 November 2002
- Published by Elsevier in Respiratory Medicine
- Vol. 96 (11) , 934-943
Relationship between lung function, ventilation–perfusion inequality and extent of emphysema as assessed by high-resolution computed tomography
- 1 November 2002
- Published by Elsevier in Respiratory Medicine
- Vol. 96 (11) , 934-943
Relationship between lung function, ventilation–perfusion inequality and extent of emphysema as assessed by high-resolution computed tomography
- 24 September 2001
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 21 (5) , 584-593
Ventilation-perfusion inequality and carbon dioxide sensitivity in hypoxaemic chronic obstructive pulmonary disease (COPD) and effects of 6 months of long-term oxygen treatment (LTOT)
The aim of our study was to find out how blood gas disturbances in stable, eucapnic, severe chronic obstructive pulmonary disease (COPD) patients with an arterial oxygen tension (PaO2) value of 7·7 (6·1–8·4) kPa are affected by ventilation–perfusion (VA/Q) relationships and carbon dioxide (CO2) sensitivity and how these parameters are influenced by 6 months of long‐term oxygen treatment (LTOT). VA/Q ratios were measured using the multiple inert gas elimination technique (MIGET). Mouth occlusion pressure 0·1 s after onset of inspiration (Pi0·1) and minute ventilation (VE) were measured to assess respiratory drive response (ΔPi0·1/ΔPCO2) and hypercapnic ventilatory response (HCVR) to CO2 rebreathing. At the start of LTOT, a normal median respiratory drive response level of 1·2 (0·2–2·3) cm H2O/kPa and a low median HCVR as compared with healthy individuals (PE, was directed towards hypoperfused lung areas. The dispersion of ventilation (log SDV; 0·47–1·76), and the dispersion of perfusion (log SDQ; 0·66–1·07) were wider than normal. The PaO2 level correlated inversely with mean VA/Q ratio for ventilation (V mean) and shunt. The PaCO2 level correlated inversely with HCVR and vital capacity. After 6 months of LTOT, no significant changes in daytime blood gas levels, CO2‐sensitivity or VA/Q ratios were found. VE tended to be reduced by 1·0 l min–1. Conclusions: An elevated V mean and probably shunting are important contributing factors for the reduced PaO2 and hypercapnic ventilatory response is a major determinant of PaCO2 in eucapnic stable hypoxaemic COPD. Six months of LTOT does not affect blood gases, CO2 sensitivity or ventilation–perfusion relationships.
- 24 September 2001
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 21 (5) , 584-593
Ventilation-perfusion inequality and carbon dioxide sensitivity in hypoxaemic chronic obstructive pulmonary disease (COPD) and effects of 6 months of long-term oxygen treatment (LTOT)
The aim of our study was to find out how blood gas disturbances in stable, eucapnic, severe chronic obstructive pulmonary disease (COPD) patients with an arterial oxygen tension (PaO2) value of 7·7 (6·1–8·4) kPa are affected by ventilation–perfusion (VA/Q) relationships and carbon dioxide (CO2) sensitivity and how these parameters are influenced by 6 months of long‐term oxygen treatment (LTOT). VA/Q ratios were measured using the multiple inert gas elimination technique (MIGET). Mouth occlusion pressure 0·1 s after onset of inspiration (Pi0·1) and minute ventilation (VE) were measured to assess respiratory drive response (ΔPi0·1/ΔPCO2) and hypercapnic ventilatory response (HCVR) to CO2 rebreathing. At the start of LTOT, a normal median respiratory drive response level of 1·2 (0·2–2·3) cm H2O/kPa and a low median HCVR as compared with healthy individuals (PE, was directed towards hypoperfused lung areas. The dispersion of ventilation (log SDV; 0·47–1·76), and the dispersion of perfusion (log SDQ; 0·66–1·07) were wider than normal. The PaO2 level correlated inversely with mean VA/Q ratio for ventilation (V mean) and shunt. The PaCO2 level correlated inversely with HCVR and vital capacity. After 6 months of LTOT, no significant changes in daytime blood gas levels, CO2‐sensitivity or VA/Q ratios were found. VE tended to be reduced by 1·0 l min–1. Conclusions: An elevated V mean and probably shunting are important contributing factors for the reduced PaO2 and hypercapnic ventilatory response is a major determinant of PaCO2 in eucapnic stable hypoxaemic COPD. Six months of LTOT does not affect blood gases, CO2 sensitivity or ventilation–perfusion relationships.
- 1 August 2001
- Published by Elsevier in Respiratory Medicine
- Vol. 95 (8) , 676-684
Effects on diffusing capacity and ventilation–perfusion relationships of budesonide inhalations for 2 months in chronic obstructive pulmonary disease (COPD)
- 1 August 2001
- Published by Elsevier in Respiratory Medicine
- Vol. 95 (8) , 676-684
Effects on diffusing capacity and ventilation–perfusion relationships of budesonide inhalations for 2 months in chronic obstructive pulmonary disease (COPD)
- 1 February 1999
- Published by Elsevier in Respiratory Medicine
- Vol. 93 (2) , 79-87
Sleep quality, carbon dioxide responsiveness and hypoxaemic patterns in nocturnal hypoxaemia due to chronic obstructive pulmonary disease (COPD) without daytime hypoxaemia
- 1 February 1999
- Published by Elsevier in Respiratory Medicine
- Vol. 93 (2) , 79-87
Sleep quality, carbon dioxide responsiveness and hypoxaemic patterns in nocturnal hypoxaemia due to chronic obstructive pulmonary disease (COPD) without daytime hypoxaemia
- 1 September 1995
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 15 (5) , 499-513
Ventilation‐perfusion inequality in nocturnal hypoxaemia due to chronic obstructive lung disease (COLD)
Nocturnal hypoxaemia is often noted in COLD patients with a daytime PaO2 above 8.0 kPa. It has been assumed that ventilation-perfusion inequality contributes to nocturnal hypoxaemia. 10 patients with advanced COLD [median FEV1 0.73 (range 0.50-1.32)l], but without daytime hypoxaemia [median PaO2 8.35 (range 8.0-12.2) kPa] were investigated with regard to possible nocturnal hypoxaemia using polysomnography. Daytime lung function was assessed by spirometry and carbon monoxide diffusion capacity (DLCO). Daytime ventilation-perfusion (VA/Q) relationships were measured by the multiple inert gas elimination technique. Dispersion of perfusion and ventilation distributions was increased [log SDQ 1.01 (range 0.80-1.35) and log SDV 0.91 (range 0.69-1.86) resp.]. Around 8% of the ventilation was directed towards high VA/Q areas (10 < VA/Q < 100). All subjects reached all sleep stages, and all but one had a nadir nocturnal oxygen saturation (SaO2) of below 90%. Their median lowest nocturnal SaO2 was 84.0 (range 70-93)% and their mean oxygen saturation in the course of desaturation episodes (MminSaO2) was 86.4 (range 83.6-91.5)%. An increased mean VA/Q ratio of ventilation distribution was associated with a reduced DLCO. Increased nocturnal episodes of wakefulness and of stage I sleep correlated with increased dead space ventilation and dispersion of the ventilation distribution. Patients with deep nocturnal desaturations had a low mean VA/Q ratio of the perfusion distribution (Q mean) (r = 0.87, P < 0.01) and increased perfusion of inferior VA/Q areas (0.1 VA/Q < 0.3). Low MminSaO2 was associated with low morning PaO2 and a low Q mean. COLD patient with solely nocturnal hypoxaemia have a high degree of pulmonary hyperinflation and emphysema. Increased sleep disruption is associated with more severe small airway disease. Increased perfusion of sparsely ventilated areas is associated with more pronounced nocturnal desaturations.
- 1 September 1995
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 15 (5) , 499-513
Ventilation‐perfusion inequality in nocturnal hypoxaemia due to chronic obstructive lung disease (COLD)
Nocturnal hypoxaemia is often noted in COLD patients with a daytime PaO2 above 8.0 kPa. It has been assumed that ventilation-perfusion inequality contributes to nocturnal hypoxaemia. 10 patients with advanced COLD [median FEV1 0.73 (range 0.50-1.32)l], but without daytime hypoxaemia [median PaO2 8.35 (range 8.0-12.2) kPa] were investigated with regard to possible nocturnal hypoxaemia using polysomnography. Daytime lung function was assessed by spirometry and carbon monoxide diffusion capacity (DLCO). Daytime ventilation-perfusion (VA/Q) relationships were measured by the multiple inert gas elimination technique. Dispersion of perfusion and ventilation distributions was increased [log SDQ 1.01 (range 0.80-1.35) and log SDV 0.91 (range 0.69-1.86) resp.]. Around 8% of the ventilation was directed towards high VA/Q areas (10 < VA/Q < 100). All subjects reached all sleep stages, and all but one had a nadir nocturnal oxygen saturation (SaO2) of below 90%. Their median lowest nocturnal SaO2 was 84.0 (range 70-93)% and their mean oxygen saturation in the course of desaturation episodes (MminSaO2) was 86.4 (range 83.6-91.5)%. An increased mean VA/Q ratio of ventilation distribution was associated with a reduced DLCO. Increased nocturnal episodes of wakefulness and of stage I sleep correlated with increased dead space ventilation and dispersion of the ventilation distribution. Patients with deep nocturnal desaturations had a low mean VA/Q ratio of the perfusion distribution (Q mean) (r = 0.87, P < 0.01) and increased perfusion of inferior VA/Q areas (0.1 VA/Q < 0.3). Low MminSaO2 was associated with low morning PaO2 and a low Q mean. COLD patient with solely nocturnal hypoxaemia have a high degree of pulmonary hyperinflation and emphysema. Increased sleep disruption is associated with more severe small airway disease. Increased perfusion of sparsely ventilated areas is associated with more pronounced nocturnal desaturations.
- 23 October 1985
- Vol. 82 (43) , 3691-5
[Asthma mortality in southern Stockholm 1969-1980].