Nai-Ho Cheung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Nai-Ho Cheung has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
J. Y. Chen
State Key Laboratory of Surface Physics and Department of Physics, Fudan University, Handan Road 220, Shanghai 200433, China
4 shared publicationsKa-Cheung Kwok
Department of Physics, Hong Kong Baptist University, Kowloon Tong, Hong Kong, China
3 shared publicationsM. C. Fung
Department of Biology, Chinese University of Hong Kong, People's Republic of China
3 shared publicationsN. K. Mak
Department of Biology, Hong Kong Baptist University, People's Republic of China
3 shared publicationsYue Cai
Department of Physics
3 shared publicationsBruno Yue Cai
2 shared publications
Latest Publications
- 24 June 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (8) , 1618-1624
ArF laser-induced plume fluorescence – normalization of the fluorescence spectra
Laser-induced plume fluorescence is linear and amenable to intensity normalization.
- 24 June 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (8) , 1618-1624
ArF laser-induced plume fluorescence – normalization of the fluorescence spectra
Laser-induced plume fluorescence is linear and amenable to intensity normalization.
- 15 October 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (12) , 2370-2377
Soft classification of single samples based on multi-analyte spectra
Plume fluorescence spectrum of an unknown can be mapped to a point (black) in class space of partial-least-square discriminant analysis. Its proximity to known classes (red, green and blue) gives its membership probability. The accuracy and confidence of prediction is excellent.
- 15 October 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (12) , 2370-2377
Soft classification of single samples based on multi-analyte spectra
Plume fluorescence spectrum of an unknown can be mapped to a point (black) in class space of partial-least-square discriminant analysis. Its proximity to known classes (red, green and blue) gives its membership probability. The accuracy and confidence of prediction is excellent.
- 19 January 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (3) , 616-622
Chemometric sorting based on laser-induced plume fluorescence: characterization of spectral noise for effective preprocessing
Single-shot laser-induced plume fluorescence spectra can be effectively denoised for clean unsupervised PCA sorting.
- 19 January 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (3) , 616-622
Chemometric sorting based on laser-induced plume fluorescence: characterization of spectral noise for effective preprocessing
Single-shot laser-induced plume fluorescence spectra can be effectively denoised for clean unsupervised PCA sorting.
- 4 October 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (12) , 2363-2374
The mechanism of ArF laser-induced fluorescence of dense plume matter
In pulsed laser ablative sampling, photoexcitation of the nascent plume can be nonselective because the energy structure is band-like. As the plume disperses, the bands taper to discrete levels and analyte emission lines become narrow. Multi-analyte fluorescence at a single excitation wavelength is therefore possible.
- 4 October 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (12) , 2363-2374
The mechanism of ArF laser-induced fluorescence of dense plume matter
In pulsed laser ablative sampling, photoexcitation of the nascent plume can be nonselective because the energy structure is band-like. As the plume disperses, the bands taper to discrete levels and analyte emission lines become narrow. Multi-analyte fluorescence at a single excitation wavelength is therefore possible.
- 15 December 2015
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (2) , 302-311
Determination of the Dipole Geometry of Fluorescent Nanoparticles Using Polarized Excitation and Emission Analysis
We demonstrate that the geometries of the absorption dipole μ ab and emission dipole μ em of nano-emitters such as quantum dots can be determined simultaneously by far-field polarimetry. The method involves plotting the emission polarization ratio against the absorption polarization ratio of single nano-emitters. Using Monte Carlo simulation, we show that these plots depend sensitively on the aspect ratio of the dipole shape. For example, the so-called 3D–2D dipole combination, that is, μ ab of radius ratio 1:1:1 and μ em of ratio 1:1:0, would give rise to a vertical line plot. Polarization ratios of commercial cadmium selenide/zinc sulfide (CdSe/ZnS) quantum dots are measured and plotted. The empirical data points are best-fitted to yield μ ab of radius ratio 1:1:0.28 and μ em of ratio 1:1:0.
- 15 December 2015
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (2) , 302-311
Determination of the Dipole Geometry of Fluorescent Nanoparticles Using Polarized Excitation and Emission Analysis
We demonstrate that the geometries of the absorption dipole μ ab and emission dipole μ em of nano-emitters such as quantum dots can be determined simultaneously by far-field polarimetry. The method involves plotting the emission polarization ratio against the absorption polarization ratio of single nano-emitters. Using Monte Carlo simulation, we show that these plots depend sensitively on the aspect ratio of the dipole shape. For example, the so-called 3D–2D dipole combination, that is, μ ab of radius ratio 1:1:1 and μ em of ratio 1:1:0, would give rise to a vertical line plot. Polarization ratios of commercial cadmium selenide/zinc sulfide (CdSe/ZnS) quantum dots are measured and plotted. The empirical data points are best-fitted to yield μ ab of radius ratio 1:1:0.28 and μ em of ratio 1:1:0.
- 1 August 2015
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 110, 51-55
Double-pulse laser ablation sampling: Enhancement of analyte emission by a second laser pulse at 213 nm
- 1 August 2015
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 110, 51-55
Double-pulse laser ablation sampling: Enhancement of analyte emission by a second laser pulse at 213 nm
- 2 September 2014
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 48 (19) , 11591-11599
Measuring the Kinetics of the Binding of Xenoestrogens and Estrogen Receptor Alpha by Fluorescence Polarization
The mechanism of endocrine disruption by environmental xenoestrogens is unclear. Bisphenol-A (BPA) is an example. Its concentration in human serum is low, and its binding with estrogen receptor (ER) is weak. Yet its effect on prostate and mammary gland development was observed. We investigated whether this effect could be explained in terms of binding kinetics. We used the method of fluorescence polarization anisotropy to measure the kinetic rate constants of the binding of ERα with 19 xenoestrogens. Relative binding affinities (RBA) were also deduced from the kinetics. We drew three observations. First, our RBAs were consistent with published values, thus establishing the validity of our results. Second, our method allowed the determination of low RBAs (∼10–4) of lipophilic ligands, such as dibutyl phthalate. They could not be measured by steady-state IC50 assays because of their low solubility. Third, we found that BPA had a surprisingly high kon > 104 M–1 s–1. While its RBA was 1500 times lower than that of 17β estradiol (E2), its kon was >1/90 that of E2. As a result, a 10 min surge of BPA from pM to nM could drive the fraction of BPA-activated ERα to a potent 0.1%. This might help to explain the observable estrogenic impacts of BPA.
- 2 September 2014
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 48 (19) , 11591-11599
Measuring the Kinetics of the Binding of Xenoestrogens and Estrogen Receptor Alpha by Fluorescence Polarization
The mechanism of endocrine disruption by environmental xenoestrogens is unclear. Bisphenol-A (BPA) is an example. Its concentration in human serum is low, and its binding with estrogen receptor (ER) is weak. Yet its effect on prostate and mammary gland development was observed. We investigated whether this effect could be explained in terms of binding kinetics. We used the method of fluorescence polarization anisotropy to measure the kinetic rate constants of the binding of ERα with 19 xenoestrogens. Relative binding affinities (RBA) were also deduced from the kinetics. We drew three observations. First, our RBAs were consistent with published values, thus establishing the validity of our results. Second, our method allowed the determination of low RBAs (∼10–4) of lipophilic ligands, such as dibutyl phthalate. They could not be measured by steady-state IC50 assays because of their low solubility. Third, we found that BPA had a surprisingly high kon > 104 M–1 s–1. While its RBA was 1500 times lower than that of 17β estradiol (E2), its kon was >1/90 that of E2. As a result, a 10 min surge of BPA from pM to nM could drive the fraction of BPA-activated ERα to a potent 0.1%. This might help to explain the observable estrogenic impacts of BPA.
- 14 February 2014
- Published by IOP Publishing in Laser Physics
- Vol. 24 (3) , 35602
Sulfonated aluminum phthalocyanines for two-photon photodynamic cancer therapy: the effect of the excitation wavelength
- 14 February 2014
- Published by IOP Publishing in Laser Physics
- Vol. 24 (3) , 35602
Sulfonated aluminum phthalocyanines for two-photon photodynamic cancer therapy: the effect of the excitation wavelength
- 10 April 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (9) , 4311-4315
Forensic Analysis of Laser Printed Ink by X-ray Fluorescence and Laser-Excited Plume Fluorescence
We demonstrated a minimally destructive two-tier approach for multielement forensic analysis of laser-printed ink. The printed document was first screened using a portable-X-ray fluorescence (XRF) probe. If the results were not conclusive, a laser microprobe was then deployed. The laser probe was based on a two-pulse scheme: the first laser pulse ablated a thin layer of the printed ink; the second laser pulse at 193 nm induced multianalytes in the desorbed ink to fluoresce. We analyzed four brands of black toners. The toners were printed on paper in the form of patches or letters or overprinted on another ink. The XRF probe could sort the four brands if the printed letters were larger than font 20. It could not tell the printing sequence in the case of overprints. The laser probe was more discriminatory; it could sort the toner brands and reveal the overprint sequence regardless of font size while the sampled area was not visibly different from neighboring areas even under the microscope. In terms of general analytical performance, the laser probe featured tens of micrometer lateral resolution and tens to hundreds of nm depth resolution and atto-mole mass detection limits. It could handle samples of arbitrary size and shape and was air compatible, and no sample pretreatment was necessary. It will prove useful whenever high-resolution and high sensitivity 3D elemental mapping is required.
- 10 April 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (9) , 4311-4315
Forensic Analysis of Laser Printed Ink by X-ray Fluorescence and Laser-Excited Plume Fluorescence
We demonstrated a minimally destructive two-tier approach for multielement forensic analysis of laser-printed ink. The printed document was first screened using a portable-X-ray fluorescence (XRF) probe. If the results were not conclusive, a laser microprobe was then deployed. The laser probe was based on a two-pulse scheme: the first laser pulse ablated a thin layer of the printed ink; the second laser pulse at 193 nm induced multianalytes in the desorbed ink to fluoresce. We analyzed four brands of black toners. The toners were printed on paper in the form of patches or letters or overprinted on another ink. The XRF probe could sort the four brands if the printed letters were larger than font 20. It could not tell the printing sequence in the case of overprints. The laser probe was more discriminatory; it could sort the toner brands and reveal the overprint sequence regardless of font size while the sampled area was not visibly different from neighboring areas even under the microscope. In terms of general analytical performance, the laser probe featured tens of micrometer lateral resolution and tens to hundreds of nm depth resolution and atto-mole mass detection limits. It could handle samples of arbitrary size and shape and was air compatible, and no sample pretreatment was necessary. It will prove useful whenever high-resolution and high sensitivity 3D elemental mapping is required.
- 15 August 2012
- Published by China Engineering Science Press Co. Ltd. in Frontiers of Physics
- Vol. 7 (6) , 670-678
Multi-element analysis by ArF laser excited atomic fluorescence of laser ablated plumes: Mechanism and applications
A new multi-element analysis technique based on laser-excited atomic fluorescence was reviewed. However, the one-wavelength-one-transition constraint was overcome. Numerous elements were induced to fluoresce at a single excitation wavelength of 193 nm. This was possible provided that the analytes were imbedded in dense plumes, such as those produced by pulsed laser ablation. The underlying mechanism of the technique was explained and corroborated. Analytical applications to metals, plastics, ceramics and their composites were discribed. Detection limits in the ng/g range and mass limits of atto moles were demonstrated. Several real-world problems, including the analysis of paint coating for trace lead, the non-destructive analysis of potteries and ink, the chemical profiling of electrode-plastic interfaces, and the analysis of ingestible lead colloids were discussed.
- 15 August 2012
- Published by China Engineering Science Press Co. Ltd. in Frontiers of Physics
- Vol. 7 (6) , 670-678
Multi-element analysis by ArF laser excited atomic fluorescence of laser ablated plumes: Mechanism and applications
A new multi-element analysis technique based on laser-excited atomic fluorescence was reviewed. However, the one-wavelength-one-transition constraint was overcome. Numerous elements were induced to fluoresce at a single excitation wavelength of 193 nm. This was possible provided that the analytes were imbedded in dense plumes, such as those produced by pulsed laser ablation. The underlying mechanism of the technique was explained and corroborated. Analytical applications to metals, plastics, ceramics and their composites were discribed. Detection limits in the ng/g range and mass limits of atto moles were demonstrated. Several real-world problems, including the analysis of paint coating for trace lead, the non-destructive analysis of potteries and ink, the chemical profiling of electrode-plastic interfaces, and the analysis of ingestible lead colloids were discussed.