Johan De Mey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Johan De Mey has a total of 247 co-authors. Here are the top co-authors by number of shared publications:
- Nico Buls
Department of Radiology, Research Centre For Digital Medicine (REDM), Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels, Belgium
16 shared publications - Michel De Maeseneer
Universitair Ziekenhuis Brussel
11 shared publications - Inneke Willekens
Department of Radiology, Universitair Ziekenhuis Brussel, Laarbeeklaan 101, 1090, Brussels, Belgium
10 shared publications - Steven Raeymaeckers
Department of Radiology, Universitair Ziekenhuis Brussel, Jette, Belgium
10 shared publications - Kaoru Tanaka
Department of Radiology, Universitair Ziekenhuis Brussel, VUB, Brussels, Belgium
7 shared publications - Carola Brussaard
Department of Radiology, Universitair Ziekenhuis Brussel, Brussels, Belgium
6 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3396
Dynamic Xenon-Enhanced Spectral CT Imaging to Evaluate Regional Lung Function in an In Vivo Rabbit Model
Background/Objectives: Pulmonary diseases exhibit spatially heterogeneous functional and structural abnormalities that are inadequately represented by conventional lung function testing. This pilot study investigates dynamic xenon-enhanced dual-energy CT (Xe-DECT) for a multiparametric assessment of lung ventilation and tissue. Methods: Four mechanically ventilated rabbits were scanned during washout of 70% xenon in oxygen using multibreath imaging with a clinical DECT both before (baseline) and after methacholine administration (post-MCh). Tracheal Xe concentration (CXe) and flow were monitored using mass spectrometry and pneumotachometry to estimate specific ventilation () and end-expiratory lung volume (EELVms). DECT-derived xenon concentration and tissue density images (mg/mL) were obtained by material decomposition, yielding and EELVDECT, respectively. Agreement with mass spectrometry and differences between baseline and post-MCh were assessed. Results: The baseline and EELVDECT agreed with the mass spectrometry, with mean differences of 0.6 min−1 [−0.2 min−1, 1.4 min−1] and 0.6 mL [−6.7 mL, 7.9 mL], respectively. Following MCh administration, the mean differences increased to −2.9 min−1 [−4.1 min−1, −1.6 min−1] for and 1.3 mL [−15.3 mL, 12.8 mL] for EELV. Post-MCh, decreased from 8.6 ± 1.6 min−1 to 3.7 ± 0.9 min−1 (p = 0.034) and EELVDECT from 29.3 ± 1.0 mL to 27.0 ± 1.3 mL (p = 0.036), whereas (p = 0.308) and EELVms (p = 0.653) showed no substantial changes. Regional analysis revealed that in well-ventilated regions matched tracheal . Conclusions: Dynamic Xe-DECT imaging enabled spatial and quantitative assessments of specific ventilation and tissue densities in an in vivo rabbit model. This technique allowed detection of focal alterations that remained undetected by tracheal measurements.- 19 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3396
Open AccessDynamic Xenon-Enhanced Spectral CT Imaging to Evaluate Regional Lung Function in an In Vivo Rabbit Model
Background/Objectives: Pulmonary diseases exhibit spatially heterogeneous functional and structural abnormalities that are inadequately represented by conventional lung function testing. This pilot study investigates dynamic xenon-enhanced dual-energy CT (Xe-DECT) for a multiparametric assessment of lung ventilation and tissue. Methods: Four mechanically ventilated rabbits were scanned during washout of 70% xenon in oxygen using multibreath imaging with a clinical DECT both before (baseline) and after methacholine administration (post-MCh). Tracheal Xe concentration (CXe) and flow were monitored using mass spectrometry and pneumotachometry to estimate specific ventilation () and end-expiratory lung volume (EELVms). DECT-derived xenon concentration and tissue density images (mg/mL) were obtained by material decomposition, yielding and EELVDECT, respectively. Agreement with mass spectrometry and differences between baseline and post-MCh were assessed. Results: The baseline and EELVDECT agreed with the mass spectrometry, with mean differences of 0.6 min−1 [−0.2 min−1, 1.4 min−1] and 0.6 mL [−6.7 mL, 7.9 mL], respectively. Following MCh administration, the mean differences increased to −2.9 min−1 [−4.1 min−1, −1.6 min−1] for and 1.3 mL [−15.3 mL, 12.8 mL] for EELV. Post-MCh, decreased from 8.6 ± 1.6 min−1 to 3.7 ± 0.9 min−1 (p = 0.034) and EELVDECT from 29.3 ± 1.0 mL to 27.0 ± 1.3 mL (p = 0.036), whereas (p = 0.308) and EELVms (p = 0.653) showed no substantial changes. Regional analysis revealed that in well-ventilated regions matched tracheal . Conclusions: Dynamic Xe-DECT imaging enabled spatial and quantitative assessments of specific ventilation and tissue densities in an in vivo rabbit model. This technique allowed detection of focal alterations that remained undetected by tracheal measurements. - Open Access
- 10 August 2026
- Published by Springer Nature in Breast Cancer Research
- Vol. 28 (1)
Micro-CT radiomics reveals the microcalcification-surrounding tissue interface as the diagnostic epicenter of breast microcalcifications
- 10 August 2026
- Published by Springer Nature in Breast Cancer Research
- Vol. 28 (1)
Open AccessMicro-CT radiomics reveals the microcalcification-surrounding tissue interface as the diagnostic epicenter of breast microcalcifications
- Open Access
- 12 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3) , 035023
Regional ventilation imaging in normal and bronchoconstricted in vivo rabbit lungs using dynamic shuttle mode Xe-enhanced DECT imaging
Objective. To investigate dynamic shuttle-mode xenon (Xe)-enhanced dual-energy CT (Xe-DECT) imaging for a regional assessment of ventilation in in vivo rabbit lungs. Approach. Four mechanically ventilated rabbits were scanned during the washout of a 70% xenon in 30% oxygen gas mixture using dynamic shuttle-mode DECT at baseline and during methacholine (MCh)-induced bronchoconstriction (post-MCh). Material decomposition was applied to generate xenon and tissue density images (mg ml −1 ). A tissue-based correction was used to isolate the xenon concentration ( C Xe ) in the gas phase of the xenon density images. The resultant C Xe images were used to investigate regional ventilation defects (VDs) by comparing the VD fraction (VDF, expressed as percentage) between baseline and post-MCh conditions. Additionally, regional ventilation efficiency within the VDs and surrounding (non-VD) areas was quantified as specific ventilation ( s V ˙ in min −1 ). Ventilation was also qualitatively assessed by evaluating ventilation distributions during washout. Main results. MCh-induced bronchoconstriction resulted in an increase in VDF. The average VDF at baseline was 13.8 ± 8.5%, compared to an average post-MCh VDF of 29.6 ± 7.7%, p = 0.026. The VDs at baseline did not reveal a reduced ventilation efficiency ( s V ˙ V D : 8.4 ± 2.7 min −1 ), compared to non-VD areas ( s V ˙ n o n − V D : 7.0 ± 3.1 min −1 ), p = 0.306. In contrast, MCh-induced VDs were found to have a reduced ventilation efficiency ( s V ˙ V D : 4.9 ± 2.3 min −1 ), compared to non-VD areas ( s V ˙ n o n − V D : 6.4 ± 2.3 min −1 ), p = 0.004 . Significance. Dynamic shuttle-mode Xe-DECT during washout enabled regional evaluation of ventilation in healthy and pathological in vivo rabbit lungs. As traditional lung function tests offer only global assessments of respiratory impairment, there is a growing interest in pulmonary functional imaging to enable quantitative evaluation of regional lung function.
- 12 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3) , 035023
Open AccessRegional ventilation imaging in normal and bronchoconstricted in vivo rabbit lungs using dynamic shuttle mode Xe-enhanced DECT imaging
Objective. To investigate dynamic shuttle-mode xenon (Xe)-enhanced dual-energy CT (Xe-DECT) imaging for a regional assessment of ventilation in in vivo rabbit lungs. Approach. Four mechanically ventilated rabbits were scanned during the washout of a 70% xenon in 30% oxygen gas mixture using dynamic shuttle-mode DECT at baseline and during methacholine (MCh)-induced bronchoconstriction (post-MCh). Material decomposition was applied to generate xenon and tissue density images (mg ml −1 ). A tissue-based correction was used to isolate the xenon concentration ( C Xe ) in the gas phase of the xenon density images. The resultant C Xe images were used to investigate regional ventilation defects (VDs) by comparing the VD fraction (VDF, expressed as percentage) between baseline and post-MCh conditions. Additionally, regional ventilation efficiency within the VDs and surrounding (non-VD) areas was quantified as specific ventilation ( s V ˙ in min −1 ). Ventilation was also qualitatively assessed by evaluating ventilation distributions during washout. Main results. MCh-induced bronchoconstriction resulted in an increase in VDF. The average VDF at baseline was 13.8 ± 8.5%, compared to an average post-MCh VDF of 29.6 ± 7.7%, p = 0.026. The VDs at baseline did not reveal a reduced ventilation efficiency ( s V ˙ V D : 8.4 ± 2.7 min −1 ), compared to non-VD areas ( s V ˙ n o n − V D : 7.0 ± 3.1 min −1 ), p = 0.306. In contrast, MCh-induced VDs were found to have a reduced ventilation efficiency ( s V ˙ V D : 4.9 ± 2.3 min −1 ), compared to non-VD areas ( s V ˙ n o n − V D : 6.4 ± 2.3 min −1 ), p = 0.004 . Significance. Dynamic shuttle-mode Xe-DECT during washout enabled regional evaluation of ventilation in healthy and pathological in vivo rabbit lungs. As traditional lung function tests offer only global assessments of respiratory impairment, there is a growing interest in pulmonary functional imaging to enable quantitative evaluation of regional lung function.
- 1 May 2025
- Published by Wiley in Echocardiography
- Vol. 42 (5) , e70137
Comparison of Diagnostic Accuracy of CT Derived Fractional Flow Reserve for Predicting Revascularization
Purpose: CT‐derived fractional‐flow‐reserve (FFRCT) is recommended for determining the indication of revascularization. Consensus on optimal fractional‐flow‐reserve (FFR) measurement methods and lesions is lacking. To investigate the diagnostic accuracy of FFRCT measurement methods for predicting revascularization and factors affecting FFRCT measurement methods.Methods: A total of 340 patients (382 vessels) who underwent CT angiography and showed ≥50% diameter stenosis (DS) on invasive coronary angiography were evaluated. Enrolled vessels were classified into four groups according to lesion length (focal, CT was measured at the distal end of the vessel (vessel‐distal FFRCT), distal to the stenotic lesion (lesion‐specific FFRCT), and trans‐lesion FFRCT (ΔFFRCT) and compared with DS. Vessel morphology and left ventricular mass were assessed.Results: In focal lesions, the predictive ability for revascularization of ΔFFRCT (AUC = 0.71) was comparable to that of DS (AUC = 0.76, p = 0.166) and higher than that of lesion‐specific FFRCT (AUC = 0.67, p < 0.001) and vessel‐distal FFRCT (AUC = 0.63, p < 0.001). Multivariable analysis showed that lesion length was the strongest predictor of ΔFFRCT (β‐coefficient = 0.42, p = 0.006). In diffuse lesions, the predictive ability for revascularization of ΔFFRCT (AUC = 0.73) was comparable to that of DS (AUC = 0.77, p = 0.667), lesion‐specific FFRCT (AUC = 0.72, p = 0.653), and vessel‐distal FFRCT (AUC = 0.69, p = 0.242). Multivariable analysis showed that lesion length was the strongest predictor of ΔFFRCT (β‐coefficient = 0.99, p < 0.001).Conclusion: The predictive performance of ΔFFRCT for revascularization was similar to DS in focal and diffuse lesions. ΔFFRCT was influenced by lesion length.
- 1 May 2025
- Published by Wiley in Echocardiography
- Vol. 42 (5) , e70137
Comparison of Diagnostic Accuracy of CT Derived Fractional Flow Reserve for Predicting Revascularization
Purpose: CT‐derived fractional‐flow‐reserve (FFRCT) is recommended for determining the indication of revascularization. Consensus on optimal fractional‐flow‐reserve (FFR) measurement methods and lesions is lacking. To investigate the diagnostic accuracy of FFRCT measurement methods for predicting revascularization and factors affecting FFRCT measurement methods.Methods: A total of 340 patients (382 vessels) who underwent CT angiography and showed ≥50% diameter stenosis (DS) on invasive coronary angiography were evaluated. Enrolled vessels were classified into four groups according to lesion length (focal, CT was measured at the distal end of the vessel (vessel‐distal FFRCT), distal to the stenotic lesion (lesion‐specific FFRCT), and trans‐lesion FFRCT (ΔFFRCT) and compared with DS. Vessel morphology and left ventricular mass were assessed.Results: In focal lesions, the predictive ability for revascularization of ΔFFRCT (AUC = 0.71) was comparable to that of DS (AUC = 0.76, p = 0.166) and higher than that of lesion‐specific FFRCT (AUC = 0.67, p < 0.001) and vessel‐distal FFRCT (AUC = 0.63, p < 0.001). Multivariable analysis showed that lesion length was the strongest predictor of ΔFFRCT (β‐coefficient = 0.42, p = 0.006). In diffuse lesions, the predictive ability for revascularization of ΔFFRCT (AUC = 0.73) was comparable to that of DS (AUC = 0.77, p = 0.667), lesion‐specific FFRCT (AUC = 0.72, p = 0.653), and vessel‐distal FFRCT (AUC = 0.69, p = 0.242). Multivariable analysis showed that lesion length was the strongest predictor of ΔFFRCT (β‐coefficient = 0.99, p < 0.001).Conclusion: The predictive performance of ΔFFRCT for revascularization was similar to DS in focal and diffuse lesions. ΔFFRCT was influenced by lesion length.
- 4 November 2024
- Published by Wiley in Echocardiography
- Vol. 41 (11) , e70025
Impact of Heterogeneous Plaque Deposition on Computed Tomography Derived Fractional Flow Reserve
L/P ratio, which indicates the proportion of lumen volume to plaque volume of the vessel, is lower in lesion than in per-lesion (RCA, 0.9 vs. 7.7; LAD, 1.4 vs. 8.1; and LCX, 0.9 vs. 8.0). For lesion located in the middle segments of the three major vessels, FFRCT drops from 0.97 to 0.78 for RCA, from 0.94 to 0.55 for LAD, and from 0.99 to 0.72 for LCX, respectively. Invasive coronary angiography shows moderate stenosis in the middle segment of the RCA but no significant obstructive coronary disease at the sites where FFRCT showed a substantial decline in the LAD and LCX. CCTA indicates coronary CT angiography; ICA, invasive coronary angiography; LAD, left anterior descending artery; LCX, left circumflex artery; RCA, right coronary artery; SOCAD, significant obstructive coronary disease.
- 4 November 2024
- Published by Wiley in Echocardiography
- Vol. 41 (11) , e70025
Impact of Heterogeneous Plaque Deposition on Computed Tomography Derived Fractional Flow Reserve
L/P ratio, which indicates the proportion of lumen volume to plaque volume of the vessel, is lower in lesion than in per-lesion (RCA, 0.9 vs. 7.7; LAD, 1.4 vs. 8.1; and LCX, 0.9 vs. 8.0). For lesion located in the middle segments of the three major vessels, FFRCT drops from 0.97 to 0.78 for RCA, from 0.94 to 0.55 for LAD, and from 0.99 to 0.72 for LCX, respectively. Invasive coronary angiography shows moderate stenosis in the middle segment of the RCA but no significant obstructive coronary disease at the sites where FFRCT showed a substantial decline in the LAD and LCX. CCTA indicates coronary CT angiography; ICA, invasive coronary angiography; LAD, left anterior descending artery; LCX, left circumflex artery; RCA, right coronary artery; SOCAD, significant obstructive coronary disease.
- Open Access
- 11 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 3, 1-12
Bridging the Gap Between Machine Learning and Medicine: A Critical Evaluation of the Dworak Regression Grade in Rectal Cancer
The growing popularity of AI has increased its widespread adoption in medicine. However, the relationship between AI and medical experts’ opinions remains elusive. This study investigated the consistency between Random Forest’s prediction for rectal cancer regression grades and doctors’ opinion based on clinical data. We examined the impact of grading system subjectivity on the algorithm. Analyzing clinical parameters and medical notes from 85 rectal cancer patients, we identified patients with ambivalent grades, the “gray-zone patients”, and explored the algorithm’s difficulty in predicting their regression grade. We also introduced a regularization parameter to test if some patients could still correctly be predicted when some statistical information is suppressed. Our results demonstrated that the gray-zone patients were significantly more difficult to classify using the algorithm, suggesting that such patients should be reviewed twice to reduce errors. Additionally, we observed that the regularization parameter did not benefit gray-zone patients as much as others. Our findings emphasize the need for AI and clinical experts to work collaboratively since the algorithm cannot consider the subjectivity that medical experts can identify. Further research is necessary to incorporate subjectivity into AI algorithms to enhance their predictive capabilities and further bridge the gap between medicine and AI.
- 11 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 3, 1-12
Open AccessBridging the Gap Between Machine Learning and Medicine: A Critical Evaluation of the Dworak Regression Grade in Rectal Cancer
The growing popularity of AI has increased its widespread adoption in medicine. However, the relationship between AI and medical experts’ opinions remains elusive. This study investigated the consistency between Random Forest’s prediction for rectal cancer regression grades and doctors’ opinion based on clinical data. We examined the impact of grading system subjectivity on the algorithm. Analyzing clinical parameters and medical notes from 85 rectal cancer patients, we identified patients with ambivalent grades, the “gray-zone patients”, and explored the algorithm’s difficulty in predicting their regression grade. We also introduced a regularization parameter to test if some patients could still correctly be predicted when some statistical information is suppressed. Our results demonstrated that the gray-zone patients were significantly more difficult to classify using the algorithm, suggesting that such patients should be reviewed twice to reduce errors. Additionally, we observed that the regularization parameter did not benefit gray-zone patients as much as others. Our findings emphasize the need for AI and clinical experts to work collaboratively since the algorithm cannot consider the subjectivity that medical experts can identify. Further research is necessary to incorporate subjectivity into AI algorithms to enhance their predictive capabilities and further bridge the gap between medicine and AI.
- Open Access
- 31 May 2024
- Published by The Korean Society of Critical Care Medicine in Acute and Critical Care
- Vol. 39 (2) , 323-326
Digital tomography in the diagnosis of a posterior pneumothorax in the intensive care unit
Portable chest radiography is a valuable tool in the intensive care unit. However, the supine position causes superposition of anatomical structures resulting in less reliable detection of certain abnormalities. Recently, a portable digital tomosynthesis (pDTS) prototype with a modified motorized x-ray device was developed. We aimed to compare the diagnostic value of pDTS to standard bedside chest radiography in the diagnosis of a posterior pneumothorax. A modified motorized x-ray device was developed to perform 15 radiographic projections while translating the x-ray tube 25 cm (10 cm ramp up and 15 cm during x-ray exposure) with a total radiation dose of 0.54 mSv. This new technique of pDTS was performed in addition to standard bedside chest x-ray in a patient with a confirmed posterior hydropneumothorax. The images were compared with the standard bedside chest x-ray and computed tomography (CT) images by two experienced radiologists. The posterior hydropneumothorax previously identified with CT was visible on tomosynthesis images but not with standard bedside imaging. Combining the digital tomosynthesis technique with the portable x-ray machine could increase the diagnostic value of bedside chest radiography for the diagnosis of posterior pneumothoraces while avoiding intrahospital transport and limiting radiation exposure compared to CT.
- 31 May 2024
- Published by The Korean Society of Critical Care Medicine in Acute and Critical Care
- Vol. 39 (2) , 323-326
Open AccessDigital tomography in the diagnosis of a posterior pneumothorax in the intensive care unit
Portable chest radiography is a valuable tool in the intensive care unit. However, the supine position causes superposition of anatomical structures resulting in less reliable detection of certain abnormalities. Recently, a portable digital tomosynthesis (pDTS) prototype with a modified motorized x-ray device was developed. We aimed to compare the diagnostic value of pDTS to standard bedside chest radiography in the diagnosis of a posterior pneumothorax. A modified motorized x-ray device was developed to perform 15 radiographic projections while translating the x-ray tube 25 cm (10 cm ramp up and 15 cm during x-ray exposure) with a total radiation dose of 0.54 mSv. This new technique of pDTS was performed in addition to standard bedside chest x-ray in a patient with a confirmed posterior hydropneumothorax. The images were compared with the standard bedside chest x-ray and computed tomography (CT) images by two experienced radiologists. The posterior hydropneumothorax previously identified with CT was visible on tomosynthesis images but not with standard bedside imaging. Combining the digital tomosynthesis technique with the portable x-ray machine could increase the diagnostic value of bedside chest radiography for the diagnosis of posterior pneumothoraces while avoiding intrahospital transport and limiting radiation exposure compared to CT.
- Open Access
- 7 April 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (20) , 1804-1815
Coronary bypass surgery guided by computed tomography in a low-risk population
Background and Aims: In patients with three-vessel disease and/or left main disease, selecting revascularization strategy based on coronary computed tomography angiography (CCTA) has a high level of virtual agreement with treatment decisions based on invasive coronary angiography (ICA).Methods: In this study, coronary artery bypass grafting (CABG) procedures were planned based on CCTA without knowledge of ICA. The CABG strategy was recommended by a central core laboratory assessing the anatomy and functionality of the coronary circulation. The primary feasibility endpoint was the percentage of operations performed without access to the ICA. The primary safety endpoint was graft patency on 30-day follow-up CCTA. Secondary endpoints included topographical adequacy of grafting, major adverse cardiac and cerebrovascular (MACCE), and major bleeding events at 30 days. The study was considered positive if the lower boundary of confidence intervals (CI) for feasibility was ≥75% (NCT04142021).Results: The study enrolled 114 patients with a mean (standard deviation) anatomical SYNTAX score and Society of Thoracic Surgery score of 43.6 (15.3) and 0.81 (0.63), respectively. Unblinding ICA was required in one case yielding a feasibility of 99.1% (95% CI 95.2%–100%). The concordance and agreement in revascularization planning between the ICA- and CCTA-Heart Teams was 82.9% with a moderate kappa of 0.58 (95% CI 0.50–0.66) and between the CCTA-Heart Team and actual treatment was 83.7% with a substantial kappa of 0.61 (95% CI 0.53–0.68). The 30-day follow-up CCTA in 102 patients (91.9%) showed an anastomosis patency rate of 92.6%, whilst MACCE was 7.2% and major bleeding 2.7%.Conclusions: CABG guided by CCTA is feasible and has an acceptable safety profile in a selected population of complex coronary artery disease.
- 7 April 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (20) , 1804-1815
Open AccessCoronary bypass surgery guided by computed tomography in a low-risk population
Background and Aims: In patients with three-vessel disease and/or left main disease, selecting revascularization strategy based on coronary computed tomography angiography (CCTA) has a high level of virtual agreement with treatment decisions based on invasive coronary angiography (ICA).Methods: In this study, coronary artery bypass grafting (CABG) procedures were planned based on CCTA without knowledge of ICA. The CABG strategy was recommended by a central core laboratory assessing the anatomy and functionality of the coronary circulation. The primary feasibility endpoint was the percentage of operations performed without access to the ICA. The primary safety endpoint was graft patency on 30-day follow-up CCTA. Secondary endpoints included topographical adequacy of grafting, major adverse cardiac and cerebrovascular (MACCE), and major bleeding events at 30 days. The study was considered positive if the lower boundary of confidence intervals (CI) for feasibility was ≥75% (NCT04142021).Results: The study enrolled 114 patients with a mean (standard deviation) anatomical SYNTAX score and Society of Thoracic Surgery score of 43.6 (15.3) and 0.81 (0.63), respectively. Unblinding ICA was required in one case yielding a feasibility of 99.1% (95% CI 95.2%–100%). The concordance and agreement in revascularization planning between the ICA- and CCTA-Heart Teams was 82.9% with a moderate kappa of 0.58 (95% CI 0.50–0.66) and between the CCTA-Heart Team and actual treatment was 83.7% with a substantial kappa of 0.61 (95% CI 0.53–0.68). The 30-day follow-up CCTA in 102 patients (91.9%) showed an anastomosis patency rate of 92.6%, whilst MACCE was 7.2% and major bleeding 2.7%.Conclusions: CABG guided by CCTA is feasible and has an acceptable safety profile in a selected population of complex coronary artery disease.
- 19 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Optimizing Rectal Cancer Patient Care: Dworak TRG Prediction via Bayesian Evolutionary Fourier-Domain Random Subspace Forest
To achieve personalized and optimized treatment for rectal cancer patients, accurate predictions of treatment response based on pre-treatment medical images are essential. However, these images often have varying settings. Our study examined the impact of standardizing pixel spacing and slice thickness on predictive accuracy in medical image analysis. Using our custom-built Evolutionary Random Subspace Forest algorithm, we investigated how altering these spatial settings affected the accuracy of tumor regression grade prediction. We examined 16 different adjustments to spacing settings in CT images taken from 139 rectal cancer patients. Furthermore, we explored a Bayesian approach within our random forest algorithm.We utilized the modified data as prior information and employed radiomics data from the same CT images as posterior information. This study revealed that these alterations notably improved both training and validation accuracy, where the Bayesian approach enhanced model generalization, indicating a close alignment between training and validation results.
- 19 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Optimizing Rectal Cancer Patient Care: Dworak TRG Prediction via Bayesian Evolutionary Fourier-Domain Random Subspace Forest
To achieve personalized and optimized treatment for rectal cancer patients, accurate predictions of treatment response based on pre-treatment medical images are essential. However, these images often have varying settings. Our study examined the impact of standardizing pixel spacing and slice thickness on predictive accuracy in medical image analysis. Using our custom-built Evolutionary Random Subspace Forest algorithm, we investigated how altering these spatial settings affected the accuracy of tumor regression grade prediction. We examined 16 different adjustments to spacing settings in CT images taken from 139 rectal cancer patients. Furthermore, we explored a Bayesian approach within our random forest algorithm.We utilized the modified data as prior information and employed radiomics data from the same CT images as posterior information. This study revealed that these alterations notably improved both training and validation accuracy, where the Bayesian approach enhanced model generalization, indicating a close alignment between training and validation results.
- Open Access
- 19 January 2024
- Published by Springer Nature in Neuroradiology
- Vol. 66 (4) , 487-506
Towards validation in clinical routine: a comparative analysis of visual MTA ratings versus the automated ratio between inferior lateral ventricle and hippocampal volumes in Alzheimer’s disease diagnosis
Purpose: To assess the performance of the inferior lateral ventricle (ILV) to hippocampal (Hip) volume ratio on brain MRI, for Alzheimer’s disease (AD) diagnostics, comparing it to individual automated ILV and hippocampal volumes, and visual medial temporal lobe atrophy (MTA) consensus ratings. Methods: One-hundred-twelve subjects (mean age ± SD, 66.85 ± 13.64 years) with varying degrees of cognitive decline underwent MRI using a Philips Ingenia 3T. The MTA scale by Scheltens, rated on coronal 3D T1-weighted images, was determined by three experienced radiologists, blinded to diagnosis and sex. Automated volumetry was computed by icobrain dm (v. 5.10) for total, left, right hippocampal, and ILV volumes. The ILV/Hip ratio, defined as the percentage ratio between ILV and hippocampal volumes, was calculated and compared against a normative reference population (n = 1903). Inter-rater agreement, association, classification accuracy, and clinical interpretability on patient level were reported. Results: Visual MTA scores showed excellent inter-rater agreement. Ordinal logistic regression and correlation analyses demonstrated robust associations between automated brain segmentations and visual MTA ratings, with the ILV/Hip ratio consistently outperforming individual hippocampal and ILV volumes. Pairwise classification accuracy showed good performance without statistically significant differences between the ILV/Hip ratio and visual MTA across disease stages, indicating potential interchangeability. Comparison to the normative population and clinical interpretability assessments showed commensurability in classifying MTA “severity” between visual MTA and ILV/Hip ratio measurements. Conclusion: The ILV/Hip ratio shows the highest correlation to visual MTA, in comparison to automated individual ILV and hippocampal volumes, offering standardized measures for diagnostic support in different stages of cognitive decline.
- 19 January 2024
- Published by Springer Nature in Neuroradiology
- Vol. 66 (4) , 487-506
Open AccessTowards validation in clinical routine: a comparative analysis of visual MTA ratings versus the automated ratio between inferior lateral ventricle and hippocampal volumes in Alzheimer’s disease diagnosis
Purpose: To assess the performance of the inferior lateral ventricle (ILV) to hippocampal (Hip) volume ratio on brain MRI, for Alzheimer’s disease (AD) diagnostics, comparing it to individual automated ILV and hippocampal volumes, and visual medial temporal lobe atrophy (MTA) consensus ratings. Methods: One-hundred-twelve subjects (mean age ± SD, 66.85 ± 13.64 years) with varying degrees of cognitive decline underwent MRI using a Philips Ingenia 3T. The MTA scale by Scheltens, rated on coronal 3D T1-weighted images, was determined by three experienced radiologists, blinded to diagnosis and sex. Automated volumetry was computed by icobrain dm (v. 5.10) for total, left, right hippocampal, and ILV volumes. The ILV/Hip ratio, defined as the percentage ratio between ILV and hippocampal volumes, was calculated and compared against a normative reference population (n = 1903). Inter-rater agreement, association, classification accuracy, and clinical interpretability on patient level were reported. Results: Visual MTA scores showed excellent inter-rater agreement. Ordinal logistic regression and correlation analyses demonstrated robust associations between automated brain segmentations and visual MTA ratings, with the ILV/Hip ratio consistently outperforming individual hippocampal and ILV volumes. Pairwise classification accuracy showed good performance without statistically significant differences between the ILV/Hip ratio and visual MTA across disease stages, indicating potential interchangeability. Comparison to the normative population and clinical interpretability assessments showed commensurability in classifying MTA “severity” between visual MTA and ILV/Hip ratio measurements. Conclusion: The ILV/Hip ratio shows the highest correlation to visual MTA, in comparison to automated individual ILV and hippocampal volumes, offering standardized measures for diagnostic support in different stages of cognitive decline.