XXXingxing Xu

Xingxing Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xingxing Xu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enamel matrix derivative expedites osteogenic differentiation of BMSCs via Wnt/β-catenin pathway in high glucose microenvironment

    by MaoHua Meng, Qian Xia, Ying Li, Xin Chen, QinYing Wang, JingQiao Chen, XingXing Xu, Huan Wang, JiaYu Shu, Jing Lu, et al.

    Introduction The influence of enamel matrix derivative (EMD) on proliferation and osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs) was explored in high glucose (HG) microenvironment with interaction of Wnt/β-catenin pathway. Materials and Methods Extraction of BMSCs from Sprague–Dawley rats, culture, and identification were manifested. The cells were treated with different concentration of EMD in HG to figure out the most available concentration for proliferation and osteogenic differentiation. Then, observation of cell growth curve and cell cycle changes, and detection of Osterix, runt-related transcription factor 2 (Runx2), COL-I, early osteogenic indexes, Calcium salt deposition, and β-catenin protein in Wnt/β-catenin pathway were assured. After adding Wnt/β-catenin pathway inhibitor (XAV-939) in the cells with osteogenesis induction, detection of binding of β-catenin to Osterix was clarified. Results Via identification BMSCs cultured in vitro was qualified. Different concentrations of EMD could accelerate cell proliferation in HG and osteogenesis induction, and 75 μg/mL EMD had the best effect. The HG augmented BMSCs proliferation and the propidium iodide index of flow cytometry cycle was elevated in HG, which were strengthened via the EMD. After BMSCs’ osteogenesis induction, Osterix, Runx2, CoL-1, early osteogenic indexes, and calcium salt deposition were reduced, but elevated via EMD. β-Catenin was the lowest in the HG, but elevated after EMD. After addition of XAV-939, reduction of β-catenin and the downstream (Osterix and Runx2) were manifested. Detection of binding protein bands was in β-catenin and Osterix of the HG after EMD treatment. Conclusion EMD may facilitate the osteogenic differentiation of BMSCs via activating the Wnt/β-catenin pathway in HG.


  • Open Access

    Redox Buffering Effects in Potentiometric Detection of DNA Using Thiol-Modified Gold Electrodes

    by Xingxing Xu, Yingtao Yu, Qitao Hu, Si Chen, Leif Nyholm, Zhen Zhang

    Label-free potentiometric detection of DNA molecules using a field-effect transistor (FET) with a gold gate offers an electrical sensing platform for rapid, straightforward, and inexpensive analyses of nucleic acid samples. To induce DNA hybridization on the FET sensor surface to enable potentiometric detection, probe DNA that is complementary to the target DNA has to be immobilized on the FET gate surface. A common method for probe DNA functionalization is based on thiol–gold chemistry, immobilizing thiol-modified probe DNA on a gold gate with thiol–gold bonds. A self-assembled monolayer (SAM), based on the same thiol–gold chemistry, is also needed to passivate the rest of the gold gate surface to prevent non-specific adsorption and to enable favorable steric configuration of the probe DNA. Herein, the applicability of such FET-based potentiometric DNA sensing was carefully investigated, using a silicon nanoribbon FET with a gold-sensing gate modified with thiol–gold chemistry. We discover that the potential of the gold-sensing electrode is determined by the mixed potential of the gold–thiol and gold–oxygen redox interactions. This mixed potential gives rise to a redox buffer effect which buffers the change in the surface charge induced by the DNA hybridization, thus suppressing the potentiometric signal. Analogous redox buffer effects may also be present for other types of potentiometric detections of biomarkers based on thiol–gold chemistry.


  • Estimating Detection Limits of Potentiometric DNA Sensors Using Surface Plasmon Resonance Analyses

    by Xingxing Xu, Asta Makaraviciute, Eldar Abdurakhmanov, Fredrik Wermeling, Shiyu Li, U. Helena Danielson, Leif Nyholm, Zhen Zhang

    As the signals of potentiometric based DNA ion-selective field effect transistor (ISFET) sensors differ largely from reports to reports, a systematic revisit to this method is needed. Herein, the hybridization of the target and probe DNA on the sensor surface and its dependence on the surface probe DNA coverage and the ionic strength were systematically investigated by surface plasmon resonance (SPR). The maximum potentiometric DNA hybridization signal that could be registered by an ISFET sensor was estimated based on the SPR measurements, without considering buffering effects from any side interaction on the sensing electrode. We found that under physiological solutions (200 to 300 mM ionic strength), the ISFET sensor could not be able to register the DNA hybridization events on the sensor surface due to Debye screening. Lowering the salt concentration to enlarge the Debye length would at the same time reduce the surface hybridization efficiency, thus suppressing the signal. This adverse effect of low salt concentration on the hybridization efficiency was also found to be more significant on surface with higher probe coverage due to steric hindrance. With the method of diluting buffer, the maximum potentiometric signal generated by the DNA hybridization was estimated to be only around 120 mV with the lowest detection limit of 30 nM, occurring on a surface with optimized probe coverage and in tris buffer with 10 mM NaCl. An alternative method would be to achieve high efficiency hybridization in the buffer with high salt concentration (1 M NaCl), then to perform potentiometric measurement in the buffer with low salt concentration (1 mM NaCl). Based on the characterization of the stability of the hybridized DNA duplexes on the sensor surface under low salt concentrations, the estimated maximum potentiometric signal could be significantly higher using the alternative method. The lowest detection limit for this alternative method was estimated to be around 0.6 nM. This work can serve as an important quantitative reference for potentiometric DNA sensors.


  • Structural Changes of Mercaptohexanol Self-Assembled Monolayers on Gold and Their Influence on Impedimetric Aptamer Sensors

    by Xingxing Xu, Asta Makaraviciute, Shalen Kumar, Chenyu Wen, Martin Sjödin, Eldar Abdurakhmanov, U. Helena Danielson, Leif Nyholm, Zhen Zhang

    Despite a large number of publications describing biosensors based on electrochemical impedance spectroscopy (EIS), little attention has been paid to the stability and reproducibility issues of the sensor interfaces. In this work, the stability and reproducibility of faradaic EIS analyses on the aptamer/mercaptohexanol (MCH) self-assembled monolayer (SAM) functionalized gold surfaces in ferri- and ferrocyanide solution were systematically evaluated prior to and after the aptamer-probe DNA hybridization. It is shown that the EIS data exhibited significant drift, and this significantly affected the reproducibility of the EIS signal of the hybridization. As a result, no significant difference between the charge transfer resistance (RCT) changes induced by the aptamer-target DNA hybridization and that caused by the drift could be identified. A conditioning of the electrode in the measurement solution for more than 12 hours was required to reach a stable RCT baseline prior to the aptamer-probe DNA hybridization. The monitored drift in RCT and CDL during the conditioning suggests that the MCH SAM on the gold surface reorganized to a thinner but more closely packed layer. We also observed that that the hot binding buffer used in the following aptamer-probe DNA hybridization process could induce additional MCH and aptamer reorganization thus further drift in RCT. As a result, the RCT change caused by the aptamer-probe DNA hybridization was less than that caused by the hot binding buffer (blank control experiment). Therefore, it is suggested that the use of high temperature in the EIS measurement should be carefully evaluated or avoided. This work provides practical guidelines for the EIS measurements. Moreover, since SAM functionalized gold electrodes are widely used in biosensors, e.g., DNA sensors, an improved understanding of the origin of the observed drift is very important for the development of well-functioning and reproducible biosensors.


  • Revisiting the factors influencing gold electrodes prepared using cyclic voltammetry

    by Xingxing Xu, Asta Makaraviciute, Jean Pettersson, Shi-Li Zhang, Leif Nyholm, Zhen Zhang