Kostas Perisinakis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kostas Perisinakis has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
John Damilakis
University of Crete, Medical School, Department of Medical Physics, Heraklion, Greece
22 shared publicationsAntonis Tzedakis
University Hospital of Heraklion, Department of Medical Physics, P.O. Box 1352, 71110 Heraklion, Crete, Greece
15 shared publications- John Damilakis
School of Medicine, University of Crete, Iraklion, Greece
15 shared publications Nicholas Gourtsoyiannis
11 shared publicationsNicholas Theocharopoulos
Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion 71003, Crete, Greece.
10 shared publicationsAntonios E. Papadakis
Department of Medical Physics, University Hospital Heraklion, University of Crete Medical School, Voutes, 71110 Heraklion, Greece
9 shared publications
Latest Publications
- 6 April 2025
- Published by Elsevier in Physica Medica
- Vol. 133, 104973
Quantification of iron in soft tissues through fast kV-switching dual-energy CT imaging: What calibration data are required?
- 6 April 2025
- Published by Elsevier in Physica Medica
- Vol. 133, 104973
Quantification of iron in soft tissues through fast kV-switching dual-energy CT imaging: What calibration data are required?
- Open Access
- 11 January 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 183, 111928
CT perfusion and MRI: A combined approach for hepatocellular carcinoma diagnosis and follow-up after locoregional treatment
- 11 January 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 183, 111928
Open AccessCT perfusion and MRI: A combined approach for hepatocellular carcinoma diagnosis and follow-up after locoregional treatment
- 18 December 2024
- Published by Springer Nature in European Radiology
- Vol. 35 (6) , 3528-3537
Comparison of radiation exposure from dual- and single-energy CT imaging protocols resulting in equivalent contrast-to-noise ratio of lesions for adults and children: a phantom study
Objectives To compare the radiation exposure from single-energy CT (SECT) against rapid kV-switching dual-energy CT (DECT) imaging in both adults and children when resulting image data offer equivalent lesion identification power. Materials and methods Lesions in an adult and a 10-year-old-child body phantom were imitated using iodine solutions of different concentrations. Phantoms were subjected to several SECT and DECT thoracic and abdominal scans using a rapid kV-switching DECT scanner. The contrast-to-noise ratio (CNR) of each lesion was measured on resulting SECT images and virtual monoenergetic images (VMI) available from DECT. The SECT scans that resulted in CNR values similar to the maximum CNR observed in VMIs derived from corresponding DECT scans were identified. SECT and DECT scans with equivalent lesion-discriminating power were compared regarding the associated radiation dose burden. Doses to the lung, breast, and esophagus from thoracic imaging and doses to the liver, kidneys, and stomach from abdominal imaging were determined through Monte Carlo simulations of SECT and DECT exposures. Results Compared to SECT imaging of the adult body phantom, organ doses from DECT were found to be 5–11% lower in thoracic imaging and 44–45% lower in abdominal imaging. Compared to SECT imaging of the 10-year-old body phantom, organ doses from DECT were found to be 2.8–3.4 times higher in thoracic imaging and 1.5–1.6 times higher in abdominal imaging. Conclusion The use of rapid kV-switching DECT instead of SECT imaging may be associated with a similar or lower dose burden in adults but a noticeably higher dose burden in children. Key Points Question How does the radiation exposure from single-energy and dual-energy CT imaging compare when both techniques provide equivalent lesion identification power? Findings Rapid kV-switching dual-energy CT compared to single-energy CT may result in a similar or lower radiation dose in adults, but higher radiation dose in children. Clinical relevance Rapid kV-switching dual-energy CT imaging in children should be preferred over single-energy CT imaging only in cases where the additional information provided is crucial for an effective diagnosis.
- 18 December 2024
- Published by Springer Nature in European Radiology
- Vol. 35 (6) , 3528-3537
Comparison of radiation exposure from dual- and single-energy CT imaging protocols resulting in equivalent contrast-to-noise ratio of lesions for adults and children: a phantom study
Objectives To compare the radiation exposure from single-energy CT (SECT) against rapid kV-switching dual-energy CT (DECT) imaging in both adults and children when resulting image data offer equivalent lesion identification power. Materials and methods Lesions in an adult and a 10-year-old-child body phantom were imitated using iodine solutions of different concentrations. Phantoms were subjected to several SECT and DECT thoracic and abdominal scans using a rapid kV-switching DECT scanner. The contrast-to-noise ratio (CNR) of each lesion was measured on resulting SECT images and virtual monoenergetic images (VMI) available from DECT. The SECT scans that resulted in CNR values similar to the maximum CNR observed in VMIs derived from corresponding DECT scans were identified. SECT and DECT scans with equivalent lesion-discriminating power were compared regarding the associated radiation dose burden. Doses to the lung, breast, and esophagus from thoracic imaging and doses to the liver, kidneys, and stomach from abdominal imaging were determined through Monte Carlo simulations of SECT and DECT exposures. Results Compared to SECT imaging of the adult body phantom, organ doses from DECT were found to be 5–11% lower in thoracic imaging and 44–45% lower in abdominal imaging. Compared to SECT imaging of the 10-year-old body phantom, organ doses from DECT were found to be 2.8–3.4 times higher in thoracic imaging and 1.5–1.6 times higher in abdominal imaging. Conclusion The use of rapid kV-switching DECT instead of SECT imaging may be associated with a similar or lower dose burden in adults but a noticeably higher dose burden in children. Key Points Question How does the radiation exposure from single-energy and dual-energy CT imaging compare when both techniques provide equivalent lesion identification power? Findings Rapid kV-switching dual-energy CT compared to single-energy CT may result in a similar or lower radiation dose in adults, but higher radiation dose in children. Clinical relevance Rapid kV-switching dual-energy CT imaging in children should be preferred over single-energy CT imaging only in cases where the additional information provided is crucial for an effective diagnosis.
- 29 May 2024
- Published by Elsevier in Physica Medica
- Vol. 122, 103381
Is deep learning-enabled real-time personalized CT dosimetry feasible using only patient images as input?
- 29 May 2024
- Published by Elsevier in Physica Medica
- Vol. 122, 103381
Is deep learning-enabled real-time personalized CT dosimetry feasible using only patient images as input?
- 19 August 2022
- Published by Elsevier in Brachytherapy
- Vol. 21 (6) , 904-911
Individualized dosimetry in Ru-106 ophthalmic brachytherapy based on MRI-derived ocular anatomical parameters
- 19 August 2022
- Published by Elsevier in Brachytherapy
- Vol. 21 (6) , 904-911
Individualized dosimetry in Ru-106 ophthalmic brachytherapy based on MRI-derived ocular anatomical parameters
- Open Access
- 19 June 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (6) , 1121
Cerebral CT Perfusion in Acute Stroke: The Effect of Lowering the Tube Load and Sampling Rate on the Reproducibility of Parametric Maps
The aim of this study was to define lower dose parameters (tube load and temporal sampling) for CT perfusion that still preserve the diagnostic efficiency of the derived parametric maps. Ninety stroke CT examinations from four clinical sites with 1 s temporal sampling and a range of tube loads (mAs) (100–180) were studied. Realistic CT noise was retrospectively added to simulate a CT perfusion protocol, with a maximum reduction of 40% tube load (mAs) combined with increased sampling intervals (up to 3 s). Perfusion maps from the original and simulated protocols were compared by: (a) similarity using a voxel-wise Pearson’s correlation coefficient r with in-house software; (b) volumetric analysis of the infarcted and hypoperfused volumes using commercial software. Pearson’s r values varied for the different perfusion metrics from 0.1 to 0.85. The mean slope of increase and cerebral blood volume present the highest r values, remaining consistently above 0.7 for all protocol versions with 2 s sampling interval. Reduction of the sampling rate from 2 s to 1 s had only modest impacts on a TMAX volume of 0.4 mL (IQR −1–3) (p = 0.04) and core volume of −1.1 mL (IQR −4–0) (p < 0.001), indicating dose savings of 50%, with no practical loss of diagnostic accuracy. The lowest possible dose protocol was 2 s temporal sampling and a tube load of 100 mAs.
- 19 June 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (6) , 1121
Open AccessCerebral CT Perfusion in Acute Stroke: The Effect of Lowering the Tube Load and Sampling Rate on the Reproducibility of Parametric Maps
The aim of this study was to define lower dose parameters (tube load and temporal sampling) for CT perfusion that still preserve the diagnostic efficiency of the derived parametric maps. Ninety stroke CT examinations from four clinical sites with 1 s temporal sampling and a range of tube loads (mAs) (100–180) were studied. Realistic CT noise was retrospectively added to simulate a CT perfusion protocol, with a maximum reduction of 40% tube load (mAs) combined with increased sampling intervals (up to 3 s). Perfusion maps from the original and simulated protocols were compared by: (a) similarity using a voxel-wise Pearson’s correlation coefficient r with in-house software; (b) volumetric analysis of the infarcted and hypoperfused volumes using commercial software. Pearson’s r values varied for the different perfusion metrics from 0.1 to 0.85. The mean slope of increase and cerebral blood volume present the highest r values, remaining consistently above 0.7 for all protocol versions with 2 s sampling interval. Reduction of the sampling rate from 2 s to 1 s had only modest impacts on a TMAX volume of 0.4 mL (IQR −1–3) (p = 0.04) and core volume of −1.1 mL (IQR −4–0) (p < 0.001), indicating dose savings of 50%, with no practical loss of diagnostic accuracy. The lowest possible dose protocol was 2 s temporal sampling and a tube load of 100 mAs.
- 1 June 2021
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 32 (6) , 807-812
Discrimination of High-Risk Type-2 Endoleak after Endovascular Aneurysm Repair through CT Perfusion: A Feasibility Study
- 1 June 2021
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 32 (6) , 807-812
Discrimination of High-Risk Type-2 Endoleak after Endovascular Aneurysm Repair through CT Perfusion: A Feasibility Study
- 1 May 2021
- Published by Elsevier in Physica Medica
- Vol. 85, 123-128
Radiation exposure to infants undergoing voiding cystourethrography: The importance of the digital imaging technology
- 1 May 2021
- Published by Elsevier in Physica Medica
- Vol. 85, 123-128
Radiation exposure to infants undergoing voiding cystourethrography: The importance of the digital imaging technology
- 6 March 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (9) , 6547-6554
A novel personalized dosimetry method for endovascular aneurysm repair (EVAR) procedures
Objective To estimate radiation doses for the primarily irradiated organs/tissues of patients subjected to standard endovascular aneurysm repair (EVAR) procedures using a novel personalized dosimetry method. Methods Dosimetric and anthropometric data were collected prospectively for eight patients who underwent standard EVAR procedures. Patient-specific Monte Carlo simulations were performed to estimate organ/tissue doses from each of the fluoroscopic and digital subtraction angiography acquisitions involved in EVAR. Individual-specific cumulative absorbed doses were estimated for the skin, spinal bone marrow, heart, kidneys, liver, colon, bladder, pancreas, stomach, and spleen and compared to corresponding values estimated through a commercially available dosimetric software package that employs standardized phantoms. Results The highest organ/tissue radiation doses from EVAR were found for the skin, spinal bone marrow, kidneys, and spleen as 192.4 mGy, 96.7 mGy, 72.9 mGy, and 33.6 mGy respectively, while the doses to the heart, liver, colon, bladder, pancreas, and stomach were 6.3 mGy, 14.4 mGy, 18.4 mGy, 14.8 mGy, 21.6 mGy, and 11.2 mGy respectively. Corresponding dose values using standardized phantoms were found to differ up to 151%. Conclusion Considerable radiation doses may be received by primarily exposed organs/tissues during standard EVAR. The specific size/anatomy of the patient and the variation in exposure parameters/beam angulation between different projections commonly involved in EVAR procedures should be taken into account if reliable organ dose data are to be derived. Key Points • A novel patient-specific dosimetry method was utilized to estimate radiation doses to the primarily irradiated organs/tissues of patients subjected to standard endovascular aneurysm repair procedures. • The use of standardized mathematical anthropomorphic phantoms to derive organ dose from fluoroscopically guided procedures may result in considerable inaccuracies due to differences in the assumed organ position/volume/shape compared to patients.
- 6 March 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (9) , 6547-6554
A novel personalized dosimetry method for endovascular aneurysm repair (EVAR) procedures
Objective To estimate radiation doses for the primarily irradiated organs/tissues of patients subjected to standard endovascular aneurysm repair (EVAR) procedures using a novel personalized dosimetry method. Methods Dosimetric and anthropometric data were collected prospectively for eight patients who underwent standard EVAR procedures. Patient-specific Monte Carlo simulations were performed to estimate organ/tissue doses from each of the fluoroscopic and digital subtraction angiography acquisitions involved in EVAR. Individual-specific cumulative absorbed doses were estimated for the skin, spinal bone marrow, heart, kidneys, liver, colon, bladder, pancreas, stomach, and spleen and compared to corresponding values estimated through a commercially available dosimetric software package that employs standardized phantoms. Results The highest organ/tissue radiation doses from EVAR were found for the skin, spinal bone marrow, kidneys, and spleen as 192.4 mGy, 96.7 mGy, 72.9 mGy, and 33.6 mGy respectively, while the doses to the heart, liver, colon, bladder, pancreas, and stomach were 6.3 mGy, 14.4 mGy, 18.4 mGy, 14.8 mGy, 21.6 mGy, and 11.2 mGy respectively. Corresponding dose values using standardized phantoms were found to differ up to 151%. Conclusion Considerable radiation doses may be received by primarily exposed organs/tissues during standard EVAR. The specific size/anatomy of the patient and the variation in exposure parameters/beam angulation between different projections commonly involved in EVAR procedures should be taken into account if reliable organ dose data are to be derived. Key Points • A novel patient-specific dosimetry method was utilized to estimate radiation doses to the primarily irradiated organs/tissues of patients subjected to standard endovascular aneurysm repair procedures. • The use of standardized mathematical anthropomorphic phantoms to derive organ dose from fluoroscopically guided procedures may result in considerable inaccuracies due to differences in the assumed organ position/volume/shape compared to patients.
- 1 November 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (4) , 259-270
Effect of scan projection radiography coverage on tube current modulation in pediatric and adult chest CT
- 1 November 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (4) , 259-270
Effect of scan projection radiography coverage on tube current modulation in pediatric and adult chest CT