Seyed Kazem Sadat Shokouhi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Seyed Kazem Sadat Shokouhi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hamid Reza Vosoughifar
Department of Civil Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
8 shared publications - A. Dolatshah
Department of Civil Engineering, Islamic Azad University, South Tehran Branch, Tehran, Iran
5 shared publications - Yousef Rahnavard
Department of Civil Engineering, Islamic Azad University, South Tehran Branch, Tehran, Iran
5 shared publications Azam Dolatshah
4 shared publicationsHamid Reza Vosoughifar
Islamic Azad University, #R##N#South Tehran Branch, #R##N#Department of Civil Engineering, #R##N#Iran
3 shared publications- S. Z. Hosseininejad
Department of Civil Engineering, Islamic Azad University, South Tehran Branch, Tehran, Iran
2 shared publications
Latest Publications
- 25 October 2013
- Published by Techno-Press in Earthquakes and Structures
- Vol. 5 (4) , 417-438
Seismic strain analysis of buried pipelines in a fault zone using hybrid FEM-ANN approach
- 25 October 2013
- Published by Techno-Press in Earthquakes and Structures
- Vol. 5 (4) , 417-438
Seismic strain analysis of buried pipelines in a fault zone using hybrid FEM-ANN approach
- 10 October 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 83-95
Optimal Sensor Placement for BOLTED-GLAND Joints in the Water Pipeline Networks Subjected to Near-Fault and Far-Fault Earthquakes
Water pipeline networks make up vital infrastructures throughout the world. Since water pipelines operate under high pressure, their failure can cause severe damage to human health and property. In this study, the water pipeline network of a district in Tehran was modeled using the Finite Element Method (FEM). Also, different soil-pipe conditions were considered and nonlinear time-history analysis was performed via seismic scaled records of Near-Fault (NF) and Far-Fault (FF) earthquakes. Furthermore,the Optimal Sensor Placement (OSP) procedure was done in which a genetic algorithm (GA) was selected to act as the solution of the optimization formulation. Only bolted-gland joints in the modeled network were considered for OSP due to their vulnerability against seismic loads. Unlike the common algorithms that employ modal analysis results, the author proposed a novel numerical approach for OSP that utilizes nonlinear time-history analysis results as an exact seismic response. The results showed that there is a significant difference between the obtained OSP results of NF and FF earthquakes.
- 10 October 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 83-95
Optimal Sensor Placement for BOLTED-GLAND Joints in the Water Pipeline Networks Subjected to Near-Fault and Far-Fault Earthquakes
Water pipeline networks make up vital infrastructures throughout the world. Since water pipelines operate under high pressure, their failure can cause severe damage to human health and property. In this study, the water pipeline network of a district in Tehran was modeled using the Finite Element Method (FEM). Also, different soil-pipe conditions were considered and nonlinear time-history analysis was performed via seismic scaled records of Near-Fault (NF) and Far-Fault (FF) earthquakes. Furthermore,the Optimal Sensor Placement (OSP) procedure was done in which a genetic algorithm (GA) was selected to act as the solution of the optimization formulation. Only bolted-gland joints in the modeled network were considered for OSP due to their vulnerability against seismic loads. Unlike the common algorithms that employ modal analysis results, the author proposed a novel numerical approach for OSP that utilizes nonlinear time-history analysis results as an exact seismic response. The results showed that there is a significant difference between the obtained OSP results of NF and FF earthquakes.
- 10 October 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 718-730
Improving the Seismic Performance of Buried Gas Pipelines Subjected to Near-Fault Earthquakes using Friction Dampers
Seismic behavior of the gas pipelines has been considered due to their vital role and also because experiences with recent earthquakes demonstrated a poor seismic performance. This research attempts to improve the seismic performance of gas pipelines subjected to near-fault (NF) earthquakes by utilizing supplemental damping. In this study, the buried gas pipelines of a zone in Tehran were modeled using finite element analysis (FEA). Moreover, nonlinear time-history analysis was performed by seismic scaled records of NF earthquakes. The results determined the critical points of pipelines which failed due to seismic waves. Friction dampers are designed to have moving parts that will slide over each other during a strong earthquake. When the parts slide over each other, they create friction which uses some of the energy from the earthquake that goes into the system. So, as a proper solution, the friction dampers were employed for better seismic performance of the system. The obtained results after damper installation showed that the failure points were retrofitted efficiently.
- 10 October 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 718-730
Improving the Seismic Performance of Buried Gas Pipelines Subjected to Near-Fault Earthquakes using Friction Dampers
Seismic behavior of the gas pipelines has been considered due to their vital role and also because experiences with recent earthquakes demonstrated a poor seismic performance. This research attempts to improve the seismic performance of gas pipelines subjected to near-fault (NF) earthquakes by utilizing supplemental damping. In this study, the buried gas pipelines of a zone in Tehran were modeled using finite element analysis (FEA). Moreover, nonlinear time-history analysis was performed by seismic scaled records of NF earthquakes. The results determined the critical points of pipelines which failed due to seismic waves. Friction dampers are designed to have moving parts that will slide over each other during a strong earthquake. When the parts slide over each other, they create friction which uses some of the energy from the earthquake that goes into the system. So, as a proper solution, the friction dampers were employed for better seismic performance of the system. The obtained results after damper installation showed that the failure points were retrofitted efficiently.
- 10 August 2013
- Published by Springer Nature in Journal of Civil Structural Health Monitoring
- Vol. 3 (4) , 257-267
Optimal sensor placement in the lightweight steel framing structures using the novel TTFD approach subjected to near-fault earthquakes
- 10 August 2013
- Published by Springer Nature in Journal of Civil Structural Health Monitoring
- Vol. 3 (4) , 257-267
Optimal sensor placement in the lightweight steel framing structures using the novel TTFD approach subjected to near-fault earthquakes
- 11 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 736-746
Optimal Sensor Placement of TYTON Joints in the Water Pipeline Networks Subjected to Near-Fault and Far-Fault Earthquakes
Water pipeline networks make up vital infrastructures throughout the world. Since water pipelines operate under high pressure, their failure can cause severe damage to human health and property. In this study, the water pipeline network of a district in Tehran was modeled using the Finite Element Method (FEM). Also, nonlinear time-history analysis was performed via seismic scaled records of Near-Fault (NF) and Far-Fault (FF) earthquakes. Furthermore, Optimal Sensor Placement (OSP) procedure was done in which a Genetic Algorithm (GA) was selected to act as the solution of the optimization formulation. Only TYTON joints in the modeled network were considered for OSP due to their vulnerability against seismic loads. Unlike the common algorithms that employ modal analysis results, the authors propose a novel approach for OSP that uses nonlinear time-history analysis results as an exact seismic response. Statistical results showed that there is a significant difference between the obtained OSP results of NF and FF earthquakes.
- 11 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 736-746
Optimal Sensor Placement of TYTON Joints in the Water Pipeline Networks Subjected to Near-Fault and Far-Fault Earthquakes
Water pipeline networks make up vital infrastructures throughout the world. Since water pipelines operate under high pressure, their failure can cause severe damage to human health and property. In this study, the water pipeline network of a district in Tehran was modeled using the Finite Element Method (FEM). Also, nonlinear time-history analysis was performed via seismic scaled records of Near-Fault (NF) and Far-Fault (FF) earthquakes. Furthermore, Optimal Sensor Placement (OSP) procedure was done in which a Genetic Algorithm (GA) was selected to act as the solution of the optimization formulation. Only TYTON joints in the modeled network were considered for OSP due to their vulnerability against seismic loads. Unlike the common algorithms that employ modal analysis results, the authors propose a novel approach for OSP that uses nonlinear time-history analysis results as an exact seismic response. Statistical results showed that there is a significant difference between the obtained OSP results of NF and FF earthquakes.
- 11 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 726-735
Improving the Blast Performance of Water Pipeline Networks Using Pneumatic Dampers
Explosion blasts can produce an overload much greater than the design load of a pipeline, potentially causing catastrophic damage to pipeline networks, both externally and internally. Given the considerable effects of explosion waves and the recommendations in related design codes, evaluation of blast waves on pipelines is important. This research evaluates the effect of pneumatic dampers on water pipelines subjected to blast loading. For this purpose, the water pipeline network of a district in Tehran was modeled using Finite Element Method (FEM). Then, an accelerograph record of a standard blast wave was applied to the model. The results indicated critical points of a network which failed due to explosion waves. Thus, pneumatic dampers were employed for behavior improvement of the mentioned points. The results demonstrated that the failure points were retrofitted efficiently by pneumatic dampers. Finally, a statistical test indicated a significant difference of the blast response effect on pipeline network before and after applying pneumatic dampers.
- 11 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 726-735
Improving the Blast Performance of Water Pipeline Networks Using Pneumatic Dampers
Explosion blasts can produce an overload much greater than the design load of a pipeline, potentially causing catastrophic damage to pipeline networks, both externally and internally. Given the considerable effects of explosion waves and the recommendations in related design codes, evaluation of blast waves on pipelines is important. This research evaluates the effect of pneumatic dampers on water pipelines subjected to blast loading. For this purpose, the water pipeline network of a district in Tehran was modeled using Finite Element Method (FEM). Then, an accelerograph record of a standard blast wave was applied to the model. The results indicated critical points of a network which failed due to explosion waves. Thus, pneumatic dampers were employed for behavior improvement of the mentioned points. The results demonstrated that the failure points were retrofitted efficiently by pneumatic dampers. Finally, a statistical test indicated a significant difference of the blast response effect on pipeline network before and after applying pneumatic dampers.
- 28 May 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 476-485
Investigating the Effective Factors of Leaky Aquifers Using a Novel Approach
Hydrogeological parameters of leaky aquifers are very important in site characterization, so these parameters are necessary information for quantitative and qualitative groundwater studies. In this paper, different methods were used to evaluate and predict the effective factors of leaky aquifer including the storage and transmissivity coefficients and hydraulic conductivity for four aquifer types classified as A, B, C and D. Pumping test was considered to calculate the storage and transmissivity coefficients experimentally and numerically. Also, Constant Head test, Single Well test, Double Well test, and Hazen formula were considered to obtain the hydraulic conductivity. Furthermore, several feed-forward two-layer artificial neural networks were trained to predict the storage coefficient, transmissivity, and hydraulic conductivity using these tests, models, or formulas. Finally, the sensitivity analysis of all these hydrogeological parameters against the change of each parameter such as discharge and the size of the gravel of the soil was done. Results indicated the behavior of the hydrogeological parameters against each parameter.
- 28 May 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 476-485
Investigating the Effective Factors of Leaky Aquifers Using a Novel Approach
Hydrogeological parameters of leaky aquifers are very important in site characterization, so these parameters are necessary information for quantitative and qualitative groundwater studies. In this paper, different methods were used to evaluate and predict the effective factors of leaky aquifer including the storage and transmissivity coefficients and hydraulic conductivity for four aquifer types classified as A, B, C and D. Pumping test was considered to calculate the storage and transmissivity coefficients experimentally and numerically. Also, Constant Head test, Single Well test, Double Well test, and Hazen formula were considered to obtain the hydraulic conductivity. Furthermore, several feed-forward two-layer artificial neural networks were trained to predict the storage coefficient, transmissivity, and hydraulic conductivity using these tests, models, or formulas. Finally, the sensitivity analysis of all these hydrogeological parameters against the change of each parameter such as discharge and the size of the gravel of the soil was done. Results indicated the behavior of the hydrogeological parameters against each parameter.
- 28 May 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1870-1879
Evaluation of Aeration Efficiency over Broad-Crested Stepped Spillways Using an Intelligent Computational Approach
Stepped spillways can enhance dissolved air flow, which increases the rate of energy dissipation and reduces the size of the energy dissipater at the downstream of the spillway. This paper was concerned with the application of a feedforward two-layer artificial neural network (ANN) to evaluate the aeration efficiency over broad-crested stepped spillways corresponding to different types of the flow regime. After the training of different networks, the best network, which includes two layers and one neuron at output layer, was selected. According to obtained results, the aeration efficiency at 20° C can be evaluated by having the discharge per unit width over the spillway, the chute slope angle, the step height, and the total number of all the steps. The obtained network was validated using laboratory data, and the proper conformity was clearly observed statistically. Furthermore, ANN results were compared with the Adaptive Network Based Fuzzy Inference System (ANFIS) results. Finally, the sensitivity analysis of the aeration efficiency against the change of each parameter of geometry of the spillways was done. Results indicated the behavior of the aeration efficiency against investigated parameters well.
- 28 May 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1870-1879
Evaluation of Aeration Efficiency over Broad-Crested Stepped Spillways Using an Intelligent Computational Approach
Stepped spillways can enhance dissolved air flow, which increases the rate of energy dissipation and reduces the size of the energy dissipater at the downstream of the spillway. This paper was concerned with the application of a feedforward two-layer artificial neural network (ANN) to evaluate the aeration efficiency over broad-crested stepped spillways corresponding to different types of the flow regime. After the training of different networks, the best network, which includes two layers and one neuron at output layer, was selected. According to obtained results, the aeration efficiency at 20° C can be evaluated by having the discharge per unit width over the spillway, the chute slope angle, the step height, and the total number of all the steps. The obtained network was validated using laboratory data, and the proper conformity was clearly observed statistically. Furthermore, ANN results were compared with the Adaptive Network Based Fuzzy Inference System (ANFIS) results. Finally, the sensitivity analysis of the aeration efficiency against the change of each parameter of geometry of the spillways was done. Results indicated the behavior of the aeration efficiency against investigated parameters well.
- 28 May 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1709-1718
Evaluation Type of Flow Regime over Broad-Crested Stepped Spillways Using a Hybrid FVM-ANN Approach
It is essential to know accurately characteristics of the flow over stepped spillways such as turbulent dissipation and flow regime. This study was concerned with application of FVM-ANN technique for investigation of the flow regime over broad-crested stepped spillways. For this purpose, finite volume method (FVM) was employed for numerical modeling of stepped spillways using laboratory data belonging to a previous research study. The perfect conformity of numerical and laboratory results is clearly observed according to a statistical test. Then, for development of the numerical model, different geometries of spillways were investigated and flow regimes over these spillways were obtained. Furthermore, it has been attempted to train an Artificial Neural Network (ANN) that includes two layers and entails one neuron on output layer using numerical results in addition to investigating the number of neurons at the first layer. As a result of using ANN, the flow regime can be evaluated by having the discharge per unit width over the spillway, the steps' height, and the channel slope's angle. Finally, the sensitivity analysis of the flow regime against the change of each parameter of geometry of the spillways was done. Results indicated the behavior of the flow regime against investigated parameters well.
- 28 May 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1709-1718
Evaluation Type of Flow Regime over Broad-Crested Stepped Spillways Using a Hybrid FVM-ANN Approach
It is essential to know accurately characteristics of the flow over stepped spillways such as turbulent dissipation and flow regime. This study was concerned with application of FVM-ANN technique for investigation of the flow regime over broad-crested stepped spillways. For this purpose, finite volume method (FVM) was employed for numerical modeling of stepped spillways using laboratory data belonging to a previous research study. The perfect conformity of numerical and laboratory results is clearly observed according to a statistical test. Then, for development of the numerical model, different geometries of spillways were investigated and flow regimes over these spillways were obtained. Furthermore, it has been attempted to train an Artificial Neural Network (ANN) that includes two layers and entails one neuron on output layer using numerical results in addition to investigating the number of neurons at the first layer. As a result of using ANN, the flow regime can be evaluated by having the discharge per unit width over the spillway, the steps' height, and the channel slope's angle. Finally, the sensitivity analysis of the flow regime against the change of each parameter of geometry of the spillways was done. Results indicated the behavior of the flow regime against investigated parameters well.
- Open Access
- 15 May 2013
- Published by Faculty of Mechanical Engineering in Strojniški vestnik - Journal of Mechanical Engineering
- Vol. 59 (5) , 301-310
Evaluation of Fluid Flow over Stepped Spillways Using the Finite Volume Method as a Novel Approach
This research deals with the development of a Computational Fluid Dynamics (CFD) code called V-Flow using MATLAB for the two-dimensional modelling of unsteady flow over stepped spillways. V-Flow can be coupled with GAMBIT software and different spillway geometries can be modelled using voronoi mesh elements. The governing equations of flow over stepped spillways were discretized using the Finite Volume Method (FVM). The Power-Law scheme, implicit time approximation, GaussSeidel method, and SIMPLE algorithm were used for the discretization procedure. The flow was considered to be a laminar fluid flow with no turbulence model. The V-Flow model was validated against velocity vectors, streamlines, static pressures, dynamic pressures, and total pressures over the spillway obtained from the FLUENT model application. The experimental model simulated using both V-Flow and FLUENT for validation according to Gonzalezs experiments. A comparison between the results obtained from the application of the different models showed good agreement according to the mass imbalance, which serves as both a useful indicator of the convergence of the fluid flow solution and as an accuracy criterion to compare the V-Flow and FLUENT results
- 15 May 2013
- Published by Faculty of Mechanical Engineering in Strojniški vestnik - Journal of Mechanical Engineering
- Vol. 59 (5) , 301-310
Open AccessEvaluation of Fluid Flow over Stepped Spillways Using the Finite Volume Method as a Novel Approach
This research deals with the development of a Computational Fluid Dynamics (CFD) code called V-Flow using MATLAB for the two-dimensional modelling of unsteady flow over stepped spillways. V-Flow can be coupled with GAMBIT software and different spillway geometries can be modelled using voronoi mesh elements. The governing equations of flow over stepped spillways were discretized using the Finite Volume Method (FVM). The Power-Law scheme, implicit time approximation, GaussSeidel method, and SIMPLE algorithm were used for the discretization procedure. The flow was considered to be a laminar fluid flow with no turbulence model. The V-Flow model was validated against velocity vectors, streamlines, static pressures, dynamic pressures, and total pressures over the spillway obtained from the FLUENT model application. The experimental model simulated using both V-Flow and FLUENT for validation according to Gonzalezs experiments. A comparison between the results obtained from the application of the different models showed good agreement according to the mass imbalance, which serves as both a useful indicator of the convergence of the fluid flow solution and as an accuracy criterion to compare the V-Flow and FLUENT results