Vemula Rama Rao
Research Subjects
Vemula Rama Rao has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Shivaji Sircar
Department of Chemical and Biomolecular Engineering, Lehigh University, Bethlehem, Pennsylvania 18015, United States
10 shared publications Mayuresh V. Kothare
Department of Chemical and Biomolecular Engineering, Lehigh University, Bethlehem, Pennsylvania, USA
6 shared publications- Shamsuzzaman Farooq
Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, 117585 Singapore
3 shared publications M. V. Kothare
Department of Chemical and Biomolecular Engineering, Lehigh University, Bethlehem, Pennsylvania, USA
2 shared publications- Matthew D. Urich
Department of Chemical and Biomolecular Engineering Lehigh University Bethlehem Pennsylvania USA
2 shared publications - Mayuresh V. Kothare
Department of Chemical and Biomolecular Engineering, Lehigh University, Bethlehem, PA, 18015, USA
2 shared publications
Latest Publications
- 27 July 2020
- Published by Wiley in AIChE Journal
- Vol. 66 (11) , e16998
Piecewise linear model predictive control of a rapid pressure swing adsorption system
Rapid pressure swing adsorption (RPSA) is a gas separation technology used in the small‐scale oxygen concentrator devices. These devices are commonly used to produce high purity (~90%) oxygen from air for oxygen rehabilitation therapy, but can also produce a much wider range of oxygen purities for other applications. RPSA is a complex, cyclic, nonlinear switched logic process resulting from the coupling of gas adsorption, heat transfer, flow reversal effects, and process logic switches. For RPSA devices to operate satisfactorily, feedback control is critical but challenging due to their inherent complexity. In this article, we present a piecewise linear model predictive control framework for operation and control of a single‐bed RPSA system. A set of coupled, nonlinear partial differential equations with flow switching conditions is used as a plant model for the RPSA process. Subspace system identification with pseudo‐random binary sequence signals applied to this plant model at multiple operating points is used to generate a family of piecewise linear models for use in the model predictive controller algorithm. Detailed descriptions of the RPSA plant model, the multiple linear model identification procedure, the controller formulation and model switching logic are presented. The closed‐loop system is evaluated in simulation using several realistic set point tracking and disturbance rejection cases.
- 27 July 2020
- Published by Wiley in AIChE Journal
- Vol. 66 (11) , e16998
Piecewise linear model predictive control of a rapid pressure swing adsorption system
Rapid pressure swing adsorption (RPSA) is a gas separation technology used in the small‐scale oxygen concentrator devices. These devices are commonly used to produce high purity (~90%) oxygen from air for oxygen rehabilitation therapy, but can also produce a much wider range of oxygen purities for other applications. RPSA is a complex, cyclic, nonlinear switched logic process resulting from the coupling of gas adsorption, heat transfer, flow reversal effects, and process logic switches. For RPSA devices to operate satisfactorily, feedback control is critical but challenging due to their inherent complexity. In this article, we present a piecewise linear model predictive control framework for operation and control of a single‐bed RPSA system. A set of coupled, nonlinear partial differential equations with flow switching conditions is used as a plant model for the RPSA process. Subspace system identification with pseudo‐random binary sequence signals applied to this plant model at multiple operating points is used to generate a family of piecewise linear models for use in the model predictive controller algorithm. Detailed descriptions of the RPSA plant model, the multiple linear model identification procedure, the controller formulation and model switching logic are presented. The closed‐loop system is evaluated in simulation using several realistic set point tracking and disturbance rejection cases.
- 2 November 2017
- Published by Wiley in AIChE Journal
- Vol. 64 (4) , 1234-1245
Multivariable model predictive control of a novel rapid pressure swing adsorption system
A multivariable model predictive control (MPC) algorithm is developed for the control and operation of a rapid pressure swing adsorption (RPSA)‐based medical oxygen concentrator. The novelty of the approach is the use of all four step durations in the RPSA cycle as independent manipulated variables in a truly multivariable context. The RPSA has a complex, cyclic, nonlinear multivariable operation that requires feedback control, and MPC provides a suitable framework for controlling such a multivariable system. The multivariable MPC presented here uses a quadratic optimization program with integral action and a linear model identified using subspace system identification techniques. The controller was designed and tested in simulation using a complex, highly coupled, nonlinear RPSA process model. The model was developed with the least restrictive assumptions compared to those reported in the literature, thereby providing a more realistic representation of the underlying physical phenomena. The resulting MPC effectively tracks set points, rejects realistic process disturbances and is shown to outperform conventional PID control. © 2017 American Institute of Chemical Engineers AIChE J, 64: 1234–1245, 2018
- 2 November 2017
- Published by Wiley in AIChE Journal
- Vol. 64 (4) , 1234-1245
Multivariable model predictive control of a novel rapid pressure swing adsorption system
A multivariable model predictive control (MPC) algorithm is developed for the control and operation of a rapid pressure swing adsorption (RPSA)‐based medical oxygen concentrator. The novelty of the approach is the use of all four step durations in the RPSA cycle as independent manipulated variables in a truly multivariable context. The RPSA has a complex, cyclic, nonlinear multivariable operation that requires feedback control, and MPC provides a suitable framework for controlling such a multivariable system. The multivariable MPC presented here uses a quadratic optimization program with integral action and a linear model identified using subspace system identification techniques. The controller was designed and tested in simulation using a complex, highly coupled, nonlinear RPSA process model. The model was developed with the least restrictive assumptions compared to those reported in the literature, thereby providing a more realistic representation of the underlying physical phenomena. The resulting MPC effectively tracks set points, rejects realistic process disturbances and is shown to outperform conventional PID control. © 2017 American Institute of Chemical Engineers AIChE J, 64: 1234–1245, 2018
- 25 July 2017
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 56 (31) , 8991-8994
Comments on the Reliability of Model Simulation of a Rapid Pressure Swing Adsorption Process for High-Purity Product
- 25 July 2017
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 56 (31) , 8991-8994
Comments on the Reliability of Model Simulation of a Rapid Pressure Swing Adsorption Process for High-Purity Product
- 18 April 2017
- Published by Wiley in AIChE Journal
- Vol. 63 (9) , 4066-4078
Comparative performance of an adiabatic and a nonadiabatic PSA process for bulk gas separation—a numerical simulation
A detailed numerical model of a Skarstrom‐like PSA process is used to investigate the separation performance of an adiabatic and a nonadiabatic process for removal of bulk CO2 impurity from inert He. The complexity of the gas phase adsorbate composition, adsorbate loading, and the adsorbent temperature profiles as functions of positions inside an adsorber at the start and end of each step of the PSA process are discussed. The separation performance of a nonadiabatic PSA process is generally inferior to that of the corresponding adiabatic process. Smaller adsorbent column diameter accentuates nonadiabatic operation and hence lower separation efficiency. Furthermore, the separation efficiency decreases more rapidly at short cycle times and smaller column diameters. Insulation of PSA columns of a process development unit operated under these conditions is recommended for reliable data analysis. © 2017 American Institute of Chemical Engineers AIChE J, 63: 4066–4078, 2017
- 18 April 2017
- Published by Wiley in AIChE Journal
- Vol. 63 (9) , 4066-4078
Comparative performance of an adiabatic and a nonadiabatic PSA process for bulk gas separation—a numerical simulation
A detailed numerical model of a Skarstrom‐like PSA process is used to investigate the separation performance of an adiabatic and a nonadiabatic process for removal of bulk CO2 impurity from inert He. The complexity of the gas phase adsorbate composition, adsorbate loading, and the adsorbent temperature profiles as functions of positions inside an adsorber at the start and end of each step of the PSA process are discussed. The separation performance of a nonadiabatic PSA process is generally inferior to that of the corresponding adiabatic process. Smaller adsorbent column diameter accentuates nonadiabatic operation and hence lower separation efficiency. Furthermore, the separation efficiency decreases more rapidly at short cycle times and smaller column diameters. Insulation of PSA columns of a process development unit operated under these conditions is recommended for reliable data analysis. © 2017 American Institute of Chemical Engineers AIChE J, 63: 4066–4078, 2017
- 10 November 2016
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 52 (1) , 35-41
Lumped heat and mass transfer coefficient for simulation of a pressure swing adsorption process
The practical implications of replacing various individual transport resistances such as gas-solid mass and heat transfer, and gas phase axial dispersions of mass and heat in a numerical model of a pressure swing adsorption (PSA) process by a single, empirical, lumped, effective mass transport coefficient were evaluated. A non-isothermal, adiabatic, four-step Skarstrom-like PSA process for production of pure helium from a binary helium-nitrogen mixture using 5A zeolite adsorbent was considered. It was found that the above-described model simplification was adequate to describe key process performances such as the bed size factor and the product recovery vis-a-vis a detailed model where the effects of all individual resistances were explicitly included.
- 10 November 2016
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 52 (1) , 35-41
Lumped heat and mass transfer coefficient for simulation of a pressure swing adsorption process
The practical implications of replacing various individual transport resistances such as gas-solid mass and heat transfer, and gas phase axial dispersions of mass and heat in a numerical model of a pressure swing adsorption (PSA) process by a single, empirical, lumped, effective mass transport coefficient were evaluated. A non-isothermal, adiabatic, four-step Skarstrom-like PSA process for production of pure helium from a binary helium-nitrogen mixture using 5A zeolite adsorbent was considered. It was found that the above-described model simplification was adequate to describe key process performances such as the bed size factor and the product recovery vis-a-vis a detailed model where the effects of all individual resistances were explicitly included.
- 14 April 2016
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 55 (16) , 4676-4681
Experimental Study of a Novel Rapid Pressure-Swing Adsorption Based Medical Oxygen Concentrator: Effect of the Adsorbent Selectivity of N2 over O2
- 14 April 2016
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 55 (16) , 4676-4681
Experimental Study of a Novel Rapid Pressure-Swing Adsorption Based Medical Oxygen Concentrator: Effect of the Adsorbent Selectivity of N2 over O2
- 4 November 2015
- Published by Wiley in AIChE Journal
- Vol. 62 (4) , 1212-1215
Performance of a medical oxygen concentrator using rapid pressure swing adsorption process: Effect of feed air pressure
The effects of feed air pressure on the steady‐state performance of a medical oxygen concentrator (MOC) were experimentally evaluated using a novel design of a MOC unit which produced a continuous stream of ∼90% O2 employing a rapid pressure swing adsorption (RPSA) process scheme. Dry, CO2 free air containing ∼1% Ar at different feed gas pressures was used in the tests in conjunction with a commercial sample of LiLSX zeolite as the N2 selective adsorbent in the process. The bed size factor (BSF) can be systematically reduced by increasing the feed air pressure for any given total cycle time. The effect of feed air pressure on the oxygen recovery (R) is, however, more complex; it increases with increasing feed pressure only at longer cycle times while the effect is marginal at shorter cycle times. The BSF cannot be indefinitely reduced by lowering total process cycle time at any pressure—a minimum is exhibited in the BSF‐cycle time plot. The minimum value of the BSF decreases as the feed pressure is increased. The cycle time for the minimum BSF is, however, not significantly altered by the feed pressure in the data range of this work. © 2015 American Institute of Chemical Engineers AIChE J, 62: 1212–1215, 2016
- 4 November 2015
- Published by Wiley in AIChE Journal
- Vol. 62 (4) , 1212-1215
Performance of a medical oxygen concentrator using rapid pressure swing adsorption process: Effect of feed air pressure
The effects of feed air pressure on the steady‐state performance of a medical oxygen concentrator (MOC) were experimentally evaluated using a novel design of a MOC unit which produced a continuous stream of ∼90% O2 employing a rapid pressure swing adsorption (RPSA) process scheme. Dry, CO2 free air containing ∼1% Ar at different feed gas pressures was used in the tests in conjunction with a commercial sample of LiLSX zeolite as the N2 selective adsorbent in the process. The bed size factor (BSF) can be systematically reduced by increasing the feed air pressure for any given total cycle time. The effect of feed air pressure on the oxygen recovery (R) is, however, more complex; it increases with increasing feed pressure only at longer cycle times while the effect is marginal at shorter cycle times. The BSF cannot be indefinitely reduced by lowering total process cycle time at any pressure—a minimum is exhibited in the BSF‐cycle time plot. The minimum value of the BSF decreases as the feed pressure is increased. The cycle time for the minimum BSF is, however, not significantly altered by the feed pressure in the data range of this work. © 2015 American Institute of Chemical Engineers AIChE J, 62: 1212–1215, 2016
- 24 February 2015
- Published by Wiley in AIChE Journal
- Vol. 61 (6) , 2008-2015
Anatomy of a rapid pressure swing adsorption process performance
A detailed numerical study of the individual and cumulative effects of various mass, heat, and momentum transfer resistances, which are generally present inside a practical adiabatic adsorber, on the overall separation performance of a rapid pressure swing adsorption (RPSA) process is performed for production of nearly pure helium gas from an equimolar binary (N2 +He) gas mixture using 5 A zeolite. Column bed size factor (BSF) and helium recovery (R) from the feed gas are used to characterize the separation performances. All practical impediments like column pressure drop, finite gas‐solid mass and heat transfer resistances, mass and heat axial dispersions in the gas phase, and heats of ad(de)sorption causing nonisothermal operation have detrimental impacts on the overall process performance, which are significantly accentuated when the total cycle time of a RPSA process is small and the product gas helium purity is high. These impediments also prohibit indefinite lowering of BSF (desired performance) by decreasing process cycle time alone. © 2015 American Institute of Chemical Engineers AIChE J, 61: 2008–2015, 2015
- 24 February 2015
- Published by Wiley in AIChE Journal
- Vol. 61 (6) , 2008-2015
Anatomy of a rapid pressure swing adsorption process performance
A detailed numerical study of the individual and cumulative effects of various mass, heat, and momentum transfer resistances, which are generally present inside a practical adiabatic adsorber, on the overall separation performance of a rapid pressure swing adsorption (RPSA) process is performed for production of nearly pure helium gas from an equimolar binary (N2 +He) gas mixture using 5 A zeolite. Column bed size factor (BSF) and helium recovery (R) from the feed gas are used to characterize the separation performances. All practical impediments like column pressure drop, finite gas‐solid mass and heat transfer resistances, mass and heat axial dispersions in the gas phase, and heats of ad(de)sorption causing nonisothermal operation have detrimental impacts on the overall process performance, which are significantly accentuated when the total cycle time of a RPSA process is small and the product gas helium purity is high. These impediments also prohibit indefinite lowering of BSF (desired performance) by decreasing process cycle time alone. © 2015 American Institute of Chemical Engineers AIChE J, 61: 2008–2015, 2015
- 31 December 2014
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 50 (10) , 1447-1452
Comparative Perfomances of Two Commercial Samples of LiLSX Zeolite for Production of 90% Oxygen from Air by a Novel Rapid Pressure Swing Adsorption System
The performances of a novel rapid pressure swing adsorption system for continuous production of ˜ 90% O2 from a compressed air feed were experimentally studied using two different samples of pelletized LiLSX zeolite. Bed size factor (BSF) and O2 recovery (R) were compared as functions of total process cycle times. The optimum performance by the samples differed substantially—one exhibiting ˜ 30% smaller BSF and ˜ 6% higher R than the other, even though the adsorption isotherms and column dynamics for the pure gases were nearly identical. Column pressure drop during the desorption step was the cause.
- 31 December 2014
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 50 (10) , 1447-1452
Comparative Perfomances of Two Commercial Samples of LiLSX Zeolite for Production of 90% Oxygen from Air by a Novel Rapid Pressure Swing Adsorption System
The performances of a novel rapid pressure swing adsorption system for continuous production of ˜ 90% O2 from a compressed air feed were experimentally studied using two different samples of pelletized LiLSX zeolite. Bed size factor (BSF) and O2 recovery (R) were compared as functions of total process cycle times. The optimum performance by the samples differed substantially—one exhibiting ˜ 30% smaller BSF and ˜ 6% higher R than the other, even though the adsorption isotherms and column dynamics for the pure gases were nearly identical. Column pressure drop during the desorption step was the cause.
- 7 August 2014
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 53 (33) , 13157-13170
Experimental Study of a Pulsed-Pressure-Swing-Adsorption Process with Very Small 5A Zeolite Particles for Oxygen Enrichment
- 7 August 2014
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 53 (33) , 13157-13170
Experimental Study of a Pulsed-Pressure-Swing-Adsorption Process with Very Small 5A Zeolite Particles for Oxygen Enrichment