Bo Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bo Zhang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Ning Yan
School of Electrical Engineering, Shenyang University of Technology, Shenyang, China
8 shared publications - Sheng Ma
School of Computer Science and Technology, Shenyang Institute of Engineering, Shenyang 110136, China
6 shared publications - Xueyan Hao
College of Computer Science and Technology, Shenyang Institute of Engineering, Shenyang 110136, China
4 shared publications - Shaohua Ma
School of Electrical Engineering, Shenyang University of Technology, Shenyang, China
3 shared publications - Wei Feng
School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China
3 shared publications - Bin Xiang
State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 5127
An Analytical Transient Model for Three-Phase Transformer Reclosing Considering Hysteresis Residual Magnetism and Recovery Control of Cascading Failures in Cyber-Physical Power Systems
In cyber-physical power systems (CPPS), the inrush current generated during transformer reclosing can easily cause misjudgment of protection devices and thus serves as an important trigger for cascading failure propagation. Existing studies mostly rely on black-box electromagnetic transient simulations or simplified magnetization models, lacking analytical approaches that account for hysteresis and residual magnetism, and therefore fail to accurately characterize the coupling mechanism between physical transients and information-layer dynamics. To address this issue, an analytical transient model for three-phase transformer reclosing is established based on the Jiles–Atherton theory, in which the hysteresis loop and residual magnetism are embedded into the electromagnetic transient process as a differential–algebraic equation (DAE) set, and the semi-analytical dependence of the inrush peak, harmonic characteristics, and decay law on the residual flux and closing angle is derived. On this basis, an inrush-feature-driven probability model of protection misjudgment is constructed, a CPPS cascading failure propagation model incorporating physical–information state transitions is developed, and an adaptive reclosing recovery control strategy based on the node fault-state reachability is proposed. Simulations on the IEEE 39-bus system show that the proposed model accurately reproduces the quantitative influence of hysteresis residual magnetism on inrush characteristics (the peak error is within 10% compared with measured/detailed simulation results), and the proposed control strategy reduces the misjudgment rate per reclosing operation from 6.78% to 1.18% (a reduction of approximately 83%) and the post-recovery load loss from 0.182% to 0.001%, compared with the conventional reclosing scheme, significantly improving the resilience and recovery efficiency of the CPPS.
- 5 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 5127
Open AccessAn Analytical Transient Model for Three-Phase Transformer Reclosing Considering Hysteresis Residual Magnetism and Recovery Control of Cascading Failures in Cyber-Physical Power Systems
In cyber-physical power systems (CPPS), the inrush current generated during transformer reclosing can easily cause misjudgment of protection devices and thus serves as an important trigger for cascading failure propagation. Existing studies mostly rely on black-box electromagnetic transient simulations or simplified magnetization models, lacking analytical approaches that account for hysteresis and residual magnetism, and therefore fail to accurately characterize the coupling mechanism between physical transients and information-layer dynamics. To address this issue, an analytical transient model for three-phase transformer reclosing is established based on the Jiles–Atherton theory, in which the hysteresis loop and residual magnetism are embedded into the electromagnetic transient process as a differential–algebraic equation (DAE) set, and the semi-analytical dependence of the inrush peak, harmonic characteristics, and decay law on the residual flux and closing angle is derived. On this basis, an inrush-feature-driven probability model of protection misjudgment is constructed, a CPPS cascading failure propagation model incorporating physical–information state transitions is developed, and an adaptive reclosing recovery control strategy based on the node fault-state reachability is proposed. Simulations on the IEEE 39-bus system show that the proposed model accurately reproduces the quantitative influence of hysteresis residual magnetism on inrush characteristics (the peak error is within 10% compared with measured/detailed simulation results), and the proposed control strategy reduces the misjudgment rate per reclosing operation from 6.78% to 1.18% (a reduction of approximately 83%) and the post-recovery load loss from 0.182% to 0.001%, compared with the conventional reclosing scheme, significantly improving the resilience and recovery efficiency of the CPPS.
- Open Access
- 23 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 4912
False Data Injection Screening for Temperature Monitoring of Distribution Transformers Based on Lightweight Blockchain and Winding Structural Fingerprinting
Temperature monitoring underpins the protection and condition assessment of distribution transformers, whose dominant failure mode is overheating-induced insulation aging; this makes temperature data the prime target of false data injection (FDI) attacks. Because FDI acts on data rather than on the physical asset, this paper exploits the winding structure, which data injection cannot alter, as a physical trust anchor: a structural fingerprint is extracted from port measurements through frequency-dependent harmonic resistance; the systematic temperature-response differences between wire-wound and foil-wound windings build an independent physical cross-check channel; and a lightweight PBFT consortium blockchain notarizes the fingerprint baseline so that a compromised local database cannot rewrite it. Structural, physical, and command consistency indicators classify input-, output-, and model-parameter-tampering attacks. Finite-element simulations and 100-round randomized attack tests show a 9.6% structural temperature deviation that provides a clear physical screening margin: the three attack types are detected and classified within 4 s at a 100% detection rate (95% CI [96.4, 100]%) and a 0.3% false-alarm rate, while a stealthy ramp injection is caught after about 105 min and a sub-threshold constant offset is caught by trend monitoring in about 4 h. A seven-node chain implemented with real ECDSA-secp256k1 signatures achieves 0.42–0.90 s finality per notarization, 8.9–19.0 notarizations/s, and a 0.47 s view change, two orders of magnitude above the field notarization demand, meeting lightweight deployment requirements.
- 23 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 4912
Open AccessFalse Data Injection Screening for Temperature Monitoring of Distribution Transformers Based on Lightweight Blockchain and Winding Structural Fingerprinting
Temperature monitoring underpins the protection and condition assessment of distribution transformers, whose dominant failure mode is overheating-induced insulation aging; this makes temperature data the prime target of false data injection (FDI) attacks. Because FDI acts on data rather than on the physical asset, this paper exploits the winding structure, which data injection cannot alter, as a physical trust anchor: a structural fingerprint is extracted from port measurements through frequency-dependent harmonic resistance; the systematic temperature-response differences between wire-wound and foil-wound windings build an independent physical cross-check channel; and a lightweight PBFT consortium blockchain notarizes the fingerprint baseline so that a compromised local database cannot rewrite it. Structural, physical, and command consistency indicators classify input-, output-, and model-parameter-tampering attacks. Finite-element simulations and 100-round randomized attack tests show a 9.6% structural temperature deviation that provides a clear physical screening margin: the three attack types are detected and classified within 4 s at a 100% detection rate (95% CI [96.4, 100]%) and a 0.3% false-alarm rate, while a stealthy ramp injection is caught after about 105 min and a sub-threshold constant offset is caught by trend monitoring in about 4 h. A seven-node chain implemented with real ECDSA-secp256k1 signatures achieves 0.42–0.90 s finality per notarization, 8.9–19.0 notarizations/s, and a 0.47 s view change, two orders of magnitude above the field notarization demand, meeting lightweight deployment requirements.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3586-3598
Dead-Beat Current Harmonic Suppression for PMSM With Motional Electromotive Force Harmonic Compensation
Conventional harmonic suppression strategies determine compensating voltages by extracting current harmonics, while neglecting the motional electromotive force harmonics (MEMFH) induced by speed fluctuations. Especially for low-inertia permanent magnet synchronous motors (PMSMs), current harmonics and speed fluctuations exhibit strong coupling, and ignoring this interaction can markedly deteriorate the suppression performance. To address this issue, this paper proposes a novel dead-beat current harmonic suppression (DCHS) strategy incorporating MEMFH compensation to mitigate harmonics generated by speed fluctuations. The proposed method establishes an accurate coupling model between current harmonics and speed fluctuations and derives the compensation voltages through a dead-beat predictive current control algorithm. A systematic design procedure and parameter tuning methodology are presented in detail. Experimental validation conducted on a PMSM drive platform across the full operating range demonstrates that the proposed DCHS strategy with MEMFH achieves effective harmonic suppression under all operating conditions and significantly outperforms conventional methods that disregard MEMFH effects.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3586-3598
Dead-Beat Current Harmonic Suppression for PMSM With Motional Electromotive Force Harmonic Compensation
Conventional harmonic suppression strategies determine compensating voltages by extracting current harmonics, while neglecting the motional electromotive force harmonics (MEMFH) induced by speed fluctuations. Especially for low-inertia permanent magnet synchronous motors (PMSMs), current harmonics and speed fluctuations exhibit strong coupling, and ignoring this interaction can markedly deteriorate the suppression performance. To address this issue, this paper proposes a novel dead-beat current harmonic suppression (DCHS) strategy incorporating MEMFH compensation to mitigate harmonics generated by speed fluctuations. The proposed method establishes an accurate coupling model between current harmonics and speed fluctuations and derives the compensation voltages through a dead-beat predictive current control algorithm. A systematic design procedure and parameter tuning methodology are presented in detail. Experimental validation conducted on a PMSM drive platform across the full operating range demonstrates that the proposed DCHS strategy with MEMFH achieves effective harmonic suppression under all operating conditions and significantly outperforms conventional methods that disregard MEMFH effects.
- Open Access
Research on Vibration and Noise of Oil Immersed Transformer Considering Influence of Transformer Oil
This study investigates the vibration and noise characteristics of oil-immersed power transformers, with a particular focus on the influence of transformer oil on structural dynamics and acoustic emission. The research integrates multi-physics modelling, finite-element simulation, and field measurements to analyze the vibration transmission paths from the core and windings to the tank wall. A fluid–structure interaction (FSI) model is developed to account for the damping effect of insulating oil, and a correction factor is introduced to adjust modal parameters. Simulation results reveal that oil significantly enhances vibration propagation, especially in the vertical direction, while structural ribs and clamping configurations affect local vibration intensity. Noise simulations show that magnetostriction is the dominant source of audible sound, with harmonic components sensitive to load and voltage variations. Experimental validation using a portable sound level meter confirms the simulation trends and highlights the spatial variability of acoustic pressure. The findings provide a theoretical and practical basis for optimizing sensor placement and developing voiceprint-based diagnostic tools for transformer condition monitoring.
Open AccessResearch on Vibration and Noise of Oil Immersed Transformer Considering Influence of Transformer Oil
This study investigates the vibration and noise characteristics of oil-immersed power transformers, with a particular focus on the influence of transformer oil on structural dynamics and acoustic emission. The research integrates multi-physics modelling, finite-element simulation, and field measurements to analyze the vibration transmission paths from the core and windings to the tank wall. A fluid–structure interaction (FSI) model is developed to account for the damping effect of insulating oil, and a correction factor is introduced to adjust modal parameters. Simulation results reveal that oil significantly enhances vibration propagation, especially in the vertical direction, while structural ribs and clamping configurations affect local vibration intensity. Noise simulations show that magnetostriction is the dominant source of audible sound, with harmonic components sensitive to load and voltage variations. Experimental validation using a portable sound level meter confirms the simulation trends and highlights the spatial variability of acoustic pressure. The findings provide a theoretical and practical basis for optimizing sensor placement and developing voiceprint-based diagnostic tools for transformer condition monitoring.
- Open Access
Model-Based Predictive Vibration Suppression Algorithm for Permanent Magnet Synchronous Motor
As applications like electric vehicles, all-electric ships, and all-electric aircraft continue to evolve, Noise, Vibration, and Harshness (NVH) issues have garnered extensive attention. However, as the core of the power system, permanent magnet synchronous motors (PMSMs) still lack control algorithms that consider vibration problems. Therefore, this paper proposes a model-based predictive vibration suppression algorithm to suppress the PMSM vibration. Firstly, this paper explores the influence of armature currents on vibration by analyzing the vibration characteristics of PMSMs, and proposes a minimum vibration current model. On this basis, according to the torque conditions required for the stable operation of the motor, a model-based predictive vibration suppression algorithm is designed. Finally, the effectiveness of the proposed algorithm is verified through prototype experiments.
Open AccessModel-Based Predictive Vibration Suppression Algorithm for Permanent Magnet Synchronous Motor
As applications like electric vehicles, all-electric ships, and all-electric aircraft continue to evolve, Noise, Vibration, and Harshness (NVH) issues have garnered extensive attention. However, as the core of the power system, permanent magnet synchronous motors (PMSMs) still lack control algorithms that consider vibration problems. Therefore, this paper proposes a model-based predictive vibration suppression algorithm to suppress the PMSM vibration. Firstly, this paper explores the influence of armature currents on vibration by analyzing the vibration characteristics of PMSMs, and proposes a minimum vibration current model. On this basis, according to the torque conditions required for the stable operation of the motor, a model-based predictive vibration suppression algorithm is designed. Finally, the effectiveness of the proposed algorithm is verified through prototype experiments.
- Open Access
A Hybrid Algorithm for PMLSM Force Ripple Suppression Based on Mechanism Model and Data Model
The force ripple of a permanent magnet synchronous linear motor (PMSLM) caused by multi-source disturbances in practical applications seriously restricts its high-precision motion control performance. The traditional single-mechanism model has difficulty fully characterizing the nonlinear disturbance factors, while the data-driven method has real-time limitations. Therefore, this paper proposes a hybrid modeling framework that integrates the physical mechanism and measured data and realizes the dynamic compensation of the force ripple by constructing a collaborative suppression algorithm. At the mechanistic level, based on electromagnetic field theory and the virtual displacement principle, an analytical model of the core disturbance terms such as the cogging effect and the end effect is established. At the data level, the acceleration sensor is used to collect the dynamic response signal in real time, and the data-driven ripple residual model is constructed by combining frequency domain analysis and parameter fitting. In order to verify the effectiveness of the algorithm, a hardware and software experimental platform including a multi-core processor, high-precision current loop controller, real-time data acquisition module, and motion control unit is built to realize the online calculation and closed-loop injection of the hybrid compensation current. Experiments show that the hybrid framework effectively compensates the unmodeled disturbance through the data model while maintaining the physical interpretability of the mechanistic model, which provides a new idea for motor performance optimization under complex working conditions.
Open AccessA Hybrid Algorithm for PMLSM Force Ripple Suppression Based on Mechanism Model and Data Model
The force ripple of a permanent magnet synchronous linear motor (PMSLM) caused by multi-source disturbances in practical applications seriously restricts its high-precision motion control performance. The traditional single-mechanism model has difficulty fully characterizing the nonlinear disturbance factors, while the data-driven method has real-time limitations. Therefore, this paper proposes a hybrid modeling framework that integrates the physical mechanism and measured data and realizes the dynamic compensation of the force ripple by constructing a collaborative suppression algorithm. At the mechanistic level, based on electromagnetic field theory and the virtual displacement principle, an analytical model of the core disturbance terms such as the cogging effect and the end effect is established. At the data level, the acceleration sensor is used to collect the dynamic response signal in real time, and the data-driven ripple residual model is constructed by combining frequency domain analysis and parameter fitting. In order to verify the effectiveness of the algorithm, a hardware and software experimental platform including a multi-core processor, high-precision current loop controller, real-time data acquisition module, and motion control unit is built to realize the online calculation and closed-loop injection of the hybrid compensation current. Experiments show that the hybrid framework effectively compensates the unmodeled disturbance through the data model while maintaining the physical interpretability of the mechanistic model, which provides a new idea for motor performance optimization under complex working conditions.
- Open Access
Enhancing Power Quality in Distributed Energy Resource Systems Through Permanent Magnet Retrofitting of Single-Phase Induction Motors
Distributed energy resource systems offer improved energy utilization and reduced transmission losses by decentralizing power generation and load management. However, the power quality is often compromised by inefficient customer-side equipment, such as single-phase induction motors, which suffer from low efficiency and poor power factor. To address this issue, this paper proposes a permanent magnet retrofitting method for single-phase induction motors, which replaces the squirrel-cage rotor with a permanent magnet rotor while preserving the original stator and winding structure. The proposed method aims to enhance motor performance without significant structural changes. A single-phase induction motor was retrofitted using the proposed method, and its performance was evaluated through finite element simulations to verify the effectiveness of the design approach. This study also investigated the key factors influencing motor starting performance after the introduction of permanent magnets. This study presents a practical and effective method for the permanent magnet retrofitting of single-phase induction motors, which contributes to improving motor efficiency and enhancing power quality in distributed energy resource systems.
Open AccessEnhancing Power Quality in Distributed Energy Resource Systems Through Permanent Magnet Retrofitting of Single-Phase Induction Motors
Distributed energy resource systems offer improved energy utilization and reduced transmission losses by decentralizing power generation and load management. However, the power quality is often compromised by inefficient customer-side equipment, such as single-phase induction motors, which suffer from low efficiency and poor power factor. To address this issue, this paper proposes a permanent magnet retrofitting method for single-phase induction motors, which replaces the squirrel-cage rotor with a permanent magnet rotor while preserving the original stator and winding structure. The proposed method aims to enhance motor performance without significant structural changes. A single-phase induction motor was retrofitted using the proposed method, and its performance was evaluated through finite element simulations to verify the effectiveness of the design approach. This study also investigated the key factors influencing motor starting performance after the introduction of permanent magnets. This study presents a practical and effective method for the permanent magnet retrofitting of single-phase induction motors, which contributes to improving motor efficiency and enhancing power quality in distributed energy resource systems.
- Open Access
Application of High Efficiency and High Precision Network Algorithm in Thermal Capacity Design of Modular Permanent Magnet Fault-Tolerant Motor
Aiming at the problems of low thermal analysis efficiency and high computational cost of traditional computational fluid dynamics (CFD) methods for modular fault-tolerant permanent magnet synchronous motors (MFT-PMSMs) under complex working conditions, this paper proposes a fast modeling and calculation method of motor temperature field based on a high-efficiency and high-precision network algorithm. In this method, the physical structure of the motor is equivalent to a parameterized network model, and the computational efficiency is significantly improved by model partitioning and Fourth-order Runge Kutta method. The temperature change of the cooling medium is further considered, and the temperature rise change of the motor at different spatial positions is effectively considered. Based on the finite element method (FEM), the space loss distribution under rated, single-phase open circuit and overload conditions is obtained and mapped to the thermal network nodes. Through the transient thermal network solution, the rapid calculation of the temperature rise law of key components such as windings and permanent magnets is realized. The accuracy of the thermal network model was verified by using fluid-structure coupling simulation and prototype test for temperature analysis. This method provides an efficient tool for thermal safety assessment and optimization in the motor fault-tolerant design stage, especially for heat capacity check under extreme conditions and fault modes.
Open AccessApplication of High Efficiency and High Precision Network Algorithm in Thermal Capacity Design of Modular Permanent Magnet Fault-Tolerant Motor
Aiming at the problems of low thermal analysis efficiency and high computational cost of traditional computational fluid dynamics (CFD) methods for modular fault-tolerant permanent magnet synchronous motors (MFT-PMSMs) under complex working conditions, this paper proposes a fast modeling and calculation method of motor temperature field based on a high-efficiency and high-precision network algorithm. In this method, the physical structure of the motor is equivalent to a parameterized network model, and the computational efficiency is significantly improved by model partitioning and Fourth-order Runge Kutta method. The temperature change of the cooling medium is further considered, and the temperature rise change of the motor at different spatial positions is effectively considered. Based on the finite element method (FEM), the space loss distribution under rated, single-phase open circuit and overload conditions is obtained and mapped to the thermal network nodes. Through the transient thermal network solution, the rapid calculation of the temperature rise law of key components such as windings and permanent magnets is realized. The accuracy of the thermal network model was verified by using fluid-structure coupling simulation and prototype test for temperature analysis. This method provides an efficient tool for thermal safety assessment and optimization in the motor fault-tolerant design stage, especially for heat capacity check under extreme conditions and fault modes.
- Open Access
Vibration Suppression Algorithm for Electromechanical Equipment in Distributed Energy Supply Systems
In recent years, distributed energy power supply systems have been widely used in remote areas and extreme environments. However, the intermittent and uncertain output power may cause power grid fluctuations, leading to higher harmonics in electromechanical equipment, especially motors. For permanent magnet synchronous motor (PMSM) systems, an electromagnetic (EM) vibration can cause problems such as energy loss and mechanical wear. Therefore, it is necessary to design control algorithms that can effectively suppress EM vibration. To this end, a vibration suppression algorithm for fractional-slot permanent magnet synchronous motors based on a d-axis current injection is proposed in this paper. Firstly, this paper analyzes the radial electromagnetic force of the fractional-slot PMSM to identify the main source of EM vibration in fractional-slot PMSMs. Based on this, the intrinsic relationship between the EM vibration of fractional-slot PMSMs and the d-axis and q-axis currents is explored, and a method for calculating the d-axis current to suppress the vibration is proposed. Experimental verification shows that the proposed algorithm can effectively suppress EM vibration.
Open AccessVibration Suppression Algorithm for Electromechanical Equipment in Distributed Energy Supply Systems
In recent years, distributed energy power supply systems have been widely used in remote areas and extreme environments. However, the intermittent and uncertain output power may cause power grid fluctuations, leading to higher harmonics in electromechanical equipment, especially motors. For permanent magnet synchronous motor (PMSM) systems, an electromagnetic (EM) vibration can cause problems such as energy loss and mechanical wear. Therefore, it is necessary to design control algorithms that can effectively suppress EM vibration. To this end, a vibration suppression algorithm for fractional-slot permanent magnet synchronous motors based on a d-axis current injection is proposed in this paper. Firstly, this paper analyzes the radial electromagnetic force of the fractional-slot PMSM to identify the main source of EM vibration in fractional-slot PMSMs. Based on this, the intrinsic relationship between the EM vibration of fractional-slot PMSMs and the d-axis and q-axis currents is explored, and a method for calculating the d-axis current to suppress the vibration is proposed. Experimental verification shows that the proposed algorithm can effectively suppress EM vibration.
- Open Access
- 19 February 2025
- Published by MDPI AG in Electronics
- Vol. 14 (4) , 815
Fast Temperature Calculation Method for Spindle Servo Permanent Magnet Motors Under Full Operating Conditions Based on the Thermal Network Method
In CNC machines, the temperature field analysis of spindle servo permanent magnet motors (SSPMMs) under rated load, overload, and weak magnetic conditions is critical for ensuring stable operation and machining accuracy. This paper proposes a temperature calculation method for SSPMMs based on the thermal network method, which is used to quickly evaluate the temperature performance of SSPMMs under different operating conditions during design. This method can calculate the steady-state or transient temperature rise under different operating conditions. First, the electromagnetic performance and heat sources of the SSPMMs were analyzed. Then, based on the thermal network method, the equivalent thermal resistances and equivalent heat dissipation coefficients of the motor components were calculated. By iterating the heat balance equation or solving the heat conduction equation for different operating conditions, the temperature distribution of SSPMMs under different operating conditions was obtained. The accuracy of the thermal network model was validated through temperature analysis using fluid–structure interaction simulations and prototype testing. The results show that the relative error between the winding temperature calculated by the proposed equivalent thermal network model and the measured temperature under different operating conditions is less than 5%. This paper provides a theoretical basis for the thermal management of SSPMM, which can quickly and accurately evaluate the temperature rise in the motor during design.
- 19 February 2025
- Published by MDPI AG in Electronics
- Vol. 14 (4) , 815
Open AccessFast Temperature Calculation Method for Spindle Servo Permanent Magnet Motors Under Full Operating Conditions Based on the Thermal Network Method
In CNC machines, the temperature field analysis of spindle servo permanent magnet motors (SSPMMs) under rated load, overload, and weak magnetic conditions is critical for ensuring stable operation and machining accuracy. This paper proposes a temperature calculation method for SSPMMs based on the thermal network method, which is used to quickly evaluate the temperature performance of SSPMMs under different operating conditions during design. This method can calculate the steady-state or transient temperature rise under different operating conditions. First, the electromagnetic performance and heat sources of the SSPMMs were analyzed. Then, based on the thermal network method, the equivalent thermal resistances and equivalent heat dissipation coefficients of the motor components were calculated. By iterating the heat balance equation or solving the heat conduction equation for different operating conditions, the temperature distribution of SSPMMs under different operating conditions was obtained. The accuracy of the thermal network model was validated through temperature analysis using fluid–structure interaction simulations and prototype testing. The results show that the relative error between the winding temperature calculated by the proposed equivalent thermal network model and the measured temperature under different operating conditions is less than 5%. This paper provides a theoretical basis for the thermal management of SSPMM, which can quickly and accurately evaluate the temperature rise in the motor during design.