NONathaniel R. Ordway

Nathaniel R. Ordway

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nathaniel R. Ordway has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A biomechanical analysis of four medial patellofemoral ligament reconstruction techniques

    by Thomas A. Bedard, Christopher K. Johnson, Richard L. Amendola, Matthew G. Scuderi, Nathaniel R. Ordway, Frederick W. Werner, John P. Cannizzaro


  • Open Access

    Biomechanical Comparison of Spacer Pin Fixation to Two Established Methods of Tibial Tuberosity Transposition Stabilization in Dogs

    by Anna Lia Sullivan, Nathaniel R. Ordway, Brian H. Park, Pavlos Natsios, Massimo Petazzoni, Selena Tinga

    Objective The aim of this cadaveric study was to compare the biomechanical outcomes of three methods of stabilization for tibial tuberosity transposition to treat medial patellar luxation: a complete osteotomy with a two-pin and tension band wire (TBW) fixation (TBW group), a partial osteotomy with a two-pin fixation (2 Pin group), and a partial osteotomy with a spacer pin fixation (Spacer Pin group). Study Design Thirty medium to large-sized canine cadaveric tibiae were dissected and randomly assigned to one of three groups: TBW, 2 Pin, and Spacer Pin groups. The patellar ligaments were loaded in tension until ultimate failure. Ultimate failure force and mode of failure were documented, stiffness was calculated, and the results were compared statistically between the three treatment groups. Results There were not any significant differences in ultimate failure force or stiffness between groups. All groups predominantly failed by patellar ligament failure, with distal tibial crest fracture/displacement being the second-most common mode in the 2 Pin and Spacer Pin groups. Conclusion The mechanical properties of the spacer pin stabilization were not different from the TBW and 2 Pin groups. The spacer pin technique could be an alternative way to stabilize tibial tuberosity following tibial tuberosity transposition with a partial osteotomy based on this cadaveric load-to-failure model.


  • A Biomechanical Comparison of Fixation Techniques in Metacarpal Shaft Fractures

    by Kevin M. Albanese, Michael J. Schreck, Frederick W. Werner, Garrett W. Esper, Nathaniel R. Ordway

    Background Typically, metacarpal shaft fractures are treated with closed reduction percutaneous pinning, intramedullary nails, or plate fixation. Recently some surgeons have begun using intramedullary headless compression screws. Questions/Purposes The purpose of this study was to compare intramedullary screw fixation to K-wire fixation, which is the standard of care in a transverse metacarpal midshaft fracture, using a cadaveric model. Our hypothesis was that intramedullary screw fixation would have a biomechanical advantage (higher stiffness and peak load to failure) when compared with dual Kirschner wire fixation of transverse metacarpal shaft fractures. Methods Four-point bend testing was performed to compare stiffness and failure load values of seven paired 2nd and 3rd metacarpals instrumented with headless intramedullary compression screw fixation or Kirschner wire fixation. Similar testing was performed on 14 unpaired 4th metacarpals. Results There was no significant difference in peak load (p = 0.60) or stiffness (p = 0.85) between fixation groups for the 2nd and 3rd instrumented metacarpals. For the instrumented 4th metacarpals, there was no significant difference in peak load (p = 0.14), but the stiffness was significantly greater (p = 0.01) for the compression screw group compared with the Kirschner wire fixation. Conclusions/Clinical Relevance In this study, the load to failure was not different between the two fixation methods and likely both techniques can sustain physiologic loads needed for rehabilitation. The greater stiffness in the 4th metacarpal compression screw group may be related to the smaller canal morphology than in the 2nd and 3rd metacarpals. Larger diameter screws may be needed to obtain a better fit particularly in the 2nd and 3rd metacarpals.


  • Effect of Stem Positioning on Biomechanical Performance of a Novel Cementless Short-Stem Canine Total Hip Implant

    by Natalie Jean Worden, Kristian J. Ash, Nathaniel R. Ordway, Mark Miller, Kenneth A. Mann, Gretchen M. VanDeventer, Dominick M. Valenzano, Mitsunori Kayano, Mizuki Tomihari, Kei Hayashi

    Objective The aim of this study was to evaluate the effect of stem positioning on the biomechanical performance of a novel, collared, short-stem total hip implant under compression and torsion ex vivo.Study Design Six canine cadaveric femurs were implanted with a collared short-stem femoral implant. Canal flare index (CFI), stem angle, absolute and relative cut heights and relative size were measured radiographically and used as independent variables. Biomechanical performance of the construct was evaluated using physiologic loading (loading) and supraphysiologic loading (failure) protocols.Results During loading protocols, compressive stiffness was influenced by absolute cut height (p = 0.018). During failure protocols, peak torque was influenced by CFI (p = 0.004) and craniocaudal relative size (p = 0.005). Peak load and torsional stiffness were not impacted by any of the radiographic variables (p > 0.05). Three of six femurs developed longitudinal fractures originating at the medial calcar at the time of failure.Conclusion The biomechanical performance of the collared short-stem implant was positively impacted by preserving more of the femoral neck, having a higher CFI and using a smaller implant size relative to the femoral neck isthmus.


  • Dual-Mobility Articulations in Femoral Neck Fractures: A Systematic Review of the Literature and Meta-analysis of the Outcomes

    by Kevin M. Albanese, Prashant Deshmane, Nilesh Patil, David A. Larsen, Nathaniel R. Ordway

    Introduction: Femoral neck fractures have been traditionally managed with hemiarthroplasty (HA) or conventional total hip arthroplasty (CTHA). There has been recent interest in using dual-mobility components (DMC) in total hip arthroplasty for patients with femoral neck fractures to provide increased stability and decrease the need for future revision. Methods: We conducted a systematic review of the literature reporting on the use of DMC in the management of femoral neck fractures in geriatric patients. We included studies in which DMC were used alone and studies that included a comparison to total hip arthroplasty or HA. The outcomes of interest were postoperative dislocation, revision, and revision surgery rates. Two separate subgroup analyses were conducted. For the comparative studies, we analyzed the differences in outcomes using a random-effects model of relative risks. For the noncomparative studies, we estimated the cumulative incidence of the different outcomes. Results: Eighteen studies met the inclusion criteria and were included in our analysis. Eleven noncomparative studies showed a cumulative incidence of dislocation to be 1.2% (95% confidence interval = 0.3% to 2.7%) when DMC were used alone. Subgroup analyses of the seven comparative studies yielded a relative risk of dislocation using DMC was 59% less than HA and 83% less than CTHA. DMC also compared favorably in terms of revision surgery and revision rates to HA. There was insufficient quality evidence to comment on revision surgery and revision rates when compared with CTHA in comparative studies, but among the noncomparative studies, there was a low rate of revision and revision surgery. Conclusions: Our study revealed overall lower risk of dislocation using DMC compared with both CTHA and HA. There were also lower revision and revision surgery rates when DMC were used compared with HA. Further studies are required to elucidate cost-effectiveness and long-term outcomes of DMC in these scenarios. Level of Evidence: Level III-meta-analysis


  • Radiographic and Biomechanical Assessment of Three Implant Designs for Canine Cementless Total Hip Replacement

    by Natalie J. Worden, Kristian J. Ash, Nathaniel R. Ordway, Mark A. Miller, Kenneth A. Mann, Gretchen M. VanDeventer, Dominick M. Valenzano, Robert Hart, Mitsunori Kayano, Kei Hayashi

    Objective The aim of this study was to evaluate the relationship between radiographic fit/fill measurements and biomechanical performance of three canine cementless total hip implant designs using an in vitro biomechanical testing protocol that replicates compression and torsion.Study Design Eighteen (six/group) canine cadaveric femurs were implanted with one of three cementless total hip implant designs: (1) collarless, (2) collared or (3) lateral bolt stems. Femoral length, canal flare index (CFI), canal fill, stem fit, stem level and stem angle were measured as independent variables. Biomechanical performance was tested using physiological, non-destructive gait loading (loading protocols) and destructive testing (failure protocols).Results During loading protocols, compressive stiffness was influenced by stem level (p < 0.05) and torsional stiffness was influenced by stem level and CFI for collarless stems (p < 0.05). During failure protocols, peak load was influenced by mediolateral (ML) stem angle (p < 0.05) and CFI (p < 0.01) for collarless stems and CFI for lateral bolt stems (p < 0.05). Peak torque was influenced by ML stem angle, craniocaudal stem angle and CFI for collarless stems (p < 0.05) and average ML fill for collared stems (p < 0.05).Conclusion Biomechanical performance of collarless stems in cementless hip arthroplasty is more impacted by radiographic fit/fill than lateral bolt and collared stems. As a result, collarless stems may be more dependent on preoperative fit and intraoperative precision.


  • The use of a hydrogel implant in the repair of osteochondral defects of the knee: A biomechanical evaluation of restoration of native contact pressures in cadaver knees

    by Ronald A. Sismondo, Frederick W. Werner, Nathaniel R. Ordway, Allen O. Osaheni, Michelle M. Blum, Matthew G. Scuderi


  • A Biomechanical Comparison of Four Hip Arthroplasty Designs in a Canine Model

    by Nathaniel R. Ordway, Kristian J. Ash, Mark A. Miller, Kenneth A. Mann, Kei Hayashi

    Objective The aim of this study was to develop an in vitro biomechanical protocol for canine cementless hip arthroplasty that represents physiological gait loading (compression and torsion) and to evaluate if three alternative implant designs improve fixation compared with the traditional collarless, tapered stem in the clinically challenging case of moderate canal flare index. Study Design Twenty-four (six/group) laboratory-prepared canine constructs were tested using a simulated gait and overload (failure) protocol. Construct stiffness, failure load/displacement and migration were measured as outcome variables. Results Simulated gait loading did not show any significant differences between implant types for peak displacement, peak rotation, torsional stiffness, subsidence or inducible displacement. The collared and collarless stem groups were stiffer in compression compared with the collarless with a lateral bolt and short-stem groups. Increasing the loading above simulated gait showed significant reductions in compressive and torsional stiffness for all implant constructs. Despite the reductions, the short-stem group showed significantly higher stiffness compared with the other three groups. Conclusion Peak failure loads (compressive and torsional) in this study were approximately four to seven times the simulated gait loading (430 N, 1.6 Nm) regardless of implant type and highlight the importance of limiting activity level (trotting, jumping) following hip replacement in the postoperative period and during the osseointegration of the implant.


  • Effect of Pedicle Fill on Axial Pullout Strength in Spinal Fixation After Rod Reduction

    by Kevin Albanese, Nathaniel R. Ordway, Stephen A. Albanese, William F. Lavelle

    Rod reduction to pedicle screws is used for a variety of spinal fixation procedures; however, it can alter the integrity of the screw-bone interface. The authors investigated the effect of pedicle fill (ratio of pedicle screw diameter to pedicle diameter) on the strength of the screw-bone interface after simulated rod reduction on 17 vertebrae (3 thoracolumbar spine specimens). Pedicle diameter was measured with standard clinical computed tomography scan protocols. The authors determined the minimum pedicle diameter for each level. Polyaxial pedicle screws were surgically placed bilaterally with a freehand technique with standard clinical anatomic landmarks. The pedicle pairs were instrumented with pedicle screws of predetermined diameter, 1 with greater than 80% fill and 1 with less than 80% fill. A simulated reduction maneuver was performed with a 5-mm gap followed by an axial pullout test to assess screw interface strength. Comparison of insertion torque between less than 80% fill and greater than 80% fill did not show significant increases. A significant difference in pullout load ( P =.043) occurred with greater than 80% fill (791±637 N) compared with less than 80% fill (636±492 N). No significant difference in stiffness was noted ( P =.154) with pedicle fill of greater than 80% (427±134 N/mm) compared with less than 80% (376±178 N/mm). The current findings support the use of greater than 80% pedicle fill for optimal screw anchoring in pedicle screw-based constructs involving rod reduction. Surgeons should consider placing screws that can safely fill vertebral pedicles, especially at the apex of the curve and the proximal and distal levels of constructs, where excessive forces are imparted to the screws. [ Orthopedics. 2017; 40(6):e990–e995.]


  • Inter- and Intra-Observer Reliability of X-Ray Assessments of Apical Vertebral Rotation

    by Satyajit Marawar, Nathaniel R. Ordway, Swamy Kurra, Richard A. Tallarico, Danielle A. Katz, Mark A. Palumbo, William F. Lavelle