Subho Paul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Subho Paul has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Narayana Prasad Padhy
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee, India
8 shared publications Narayana Prasad Padhy
5 shared publications- Biswarup Ganguly
Department of Electrical Engineering, National Institute of Technology Silchar, Silchar, Assam, India
2 shared publications - Krishna Murari
Electrical Engineering Department, Indian Institute of Technology Bhilai, Chhattisgarh, India
2 shared publications - Sayanjit Singha Roy
Electrical Engineering Department, National Institute of Technology at Silchar, Silchar, Assam, India
2 shared publications - Shamim Hasan
EPIC, and Department of Electrical Engineering, University of North Carolina at Charlotte, Charlotte, NC, USA
2 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Canadian Journal of Electrical and Computer Engineering
- Vol. 49 (4) , 653-664
Impact of Wind and Sea Loadings on the Voyage of All-Electric Ship
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Canadian Journal of Electrical and Computer Engineering
- Vol. 49 (4) , 653-664
Impact of Wind and Sea Loadings on the Voyage of All-Electric Ship
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5311-5323
Fully Distributed and Fast Optimization Approaches for AC-DC Radial Distribution Networks With Dynamic Load and DER Response
This paper addresses the computational challenges posed by integrating massive distributed energy resources (DERs) into evolving AC-DC distribution networks. As conventional centralized optimization approaches struggle to handle the increased complexity at the grid edge, we propose an Alternating Direction Method of Multipliers (ADMM)-based consensus approach for a fully distributed active power loss minimization strategy based on second-order conic programming (SOCP). Then, we extended the approach to another distributed approach based on block-coordinated descent to improve the convergence time by reducing the number of macro-iterations compared to ADMM for extensive networks. The original centralized problem is partitioned into multiple sub-problems, each further divided into three distinct areas corresponding to the AC, DC, and voltage source converter. Our approach efficiently determines optimal operating conditions by enabling parallel solutions of these sub-problems and facilitating the sharing of global information among different agents. Simulation results on 33-bus, 132-bus, 123-bus, and an extensive 8500-bus AC-DC radial test systems, under dynamic load and DER output scenarios, demonstrate that the proposed distributed strategy achieves optimal decisions significantly faster than centralized and state-of-the-art ADMM methods.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5311-5323
Fully Distributed and Fast Optimization Approaches for AC-DC Radial Distribution Networks With Dynamic Load and DER Response
This paper addresses the computational challenges posed by integrating massive distributed energy resources (DERs) into evolving AC-DC distribution networks. As conventional centralized optimization approaches struggle to handle the increased complexity at the grid edge, we propose an Alternating Direction Method of Multipliers (ADMM)-based consensus approach for a fully distributed active power loss minimization strategy based on second-order conic programming (SOCP). Then, we extended the approach to another distributed approach based on block-coordinated descent to improve the convergence time by reducing the number of macro-iterations compared to ADMM for extensive networks. The original centralized problem is partitioned into multiple sub-problems, each further divided into three distinct areas corresponding to the AC, DC, and voltage source converter. Our approach efficiently determines optimal operating conditions by enabling parallel solutions of these sub-problems and facilitating the sharing of global information among different agents. Simulation results on 33-bus, 132-bus, 123-bus, and an extensive 8500-bus AC-DC radial test systems, under dynamic load and DER output scenarios, demonstrate that the proposed distributed strategy achieves optimal decisions significantly faster than centralized and state-of-the-art ADMM methods.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 8688-8702
Advanced Distribution Use of Network Pricing Method for Equitable Cost Allocation in Distributed Energy Resources Integrated Power Systems
Distribution Use of Network (DUoN) charges are crucial for recovering the costs of installing, operating, and maintaining the distribution network (DN) assets. This article presents a pricing algorithm to charge consumers and distributed energy resources (DERs) based on their impact on the distribution network. This method utilizes a sensitivity approach to calculate the deviation in system annual chargeable cost based on the incremental change in a) the real and reactive power flow of the facilities, b) the MW-Miles and MVAr-Miles flow of the system, and c) the power factor of the system. This reflects the combined effect of all these parameters and either charges or incentivizes the consumers based on the amount of real and reactive power they are consuming, the distance used to support customers’ real and reactive power injection/withdrawal, the capacity of DN assets being utilized while power is being delivered to consumers and influence on system power factor.The main advantage of the proposed approach is that it is not dependent on the tracing algorithm to detect the power flow paths, hence capable of computing DUoN for decent-sized DNs embedded with DERs, where the contribution of power to the consumers by the DERs or from the grid is difficult to determine or trace. Additionally, due to the appraising and penalizing characteristics of the proposed DUoN charging mechanism, the proposed pricing algorithm may encourage users to act based on local economic signals. This algorithm has been tested on a modified Western network, the IEEE-15 bus network, the IEEE-69 bus network, and the IEEE-123 bus network.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 8688-8702
Advanced Distribution Use of Network Pricing Method for Equitable Cost Allocation in Distributed Energy Resources Integrated Power Systems
Distribution Use of Network (DUoN) charges are crucial for recovering the costs of installing, operating, and maintaining the distribution network (DN) assets. This article presents a pricing algorithm to charge consumers and distributed energy resources (DERs) based on their impact on the distribution network. This method utilizes a sensitivity approach to calculate the deviation in system annual chargeable cost based on the incremental change in a) the real and reactive power flow of the facilities, b) the MW-Miles and MVAr-Miles flow of the system, and c) the power factor of the system. This reflects the combined effect of all these parameters and either charges or incentivizes the consumers based on the amount of real and reactive power they are consuming, the distance used to support customers’ real and reactive power injection/withdrawal, the capacity of DN assets being utilized while power is being delivered to consumers and influence on system power factor.The main advantage of the proposed approach is that it is not dependent on the tracing algorithm to detect the power flow paths, hence capable of computing DUoN for decent-sized DNs embedded with DERs, where the contribution of power to the consumers by the DERs or from the grid is difficult to determine or trace. Additionally, due to the appraising and penalizing characteristics of the proposed DUoN charging mechanism, the proposed pricing algorithm may encourage users to act based on local economic signals. This algorithm has been tested on a modified Western network, the IEEE-15 bus network, the IEEE-69 bus network, and the IEEE-123 bus network.
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 5251-5260
Condition Monitoring of Polymeric Insulators: A Remote Diagnostic Framework With Improved Intermediate Hydrophobicity Grade Detection
Polymeric insulators deliver superior pollution performance owing to their excellent hydrophobic characteristics. However, due to aging, temporary loss of hydrophobicity occurs and continuous water films start to form, leading to dry-band arcing and subsequently, flashover of the insulators. Hence, accurate identification of different hydrophobicity grades (HGs) is essential. Considering this issue, a novel image visibility theory-aided remote HG detection framework with improved intermediate HG identification has been proposed in this contribution. To achieve this, image visibility patches (VPs) were extracted to quantify the intricate pixel-level alterations taking place particularly for the intermediate HGs. In addition, the concept of uniform visibility patches is proposed to reduce computational burden of the conventional VP extraction process along with providing additional noise resiliency. The employed HG detection methodology infused with a transformer encoder-based classifier module was trained on experimental HG images acquired from an 11kV silicone rubber (SiR) insulator and tested on benchmark data utilizing a cross-dataset learning strategy, which yielded satisfactorily high HG detection performance, Ablation study in addition to comparison with existing studies revealed superior efficiency of the proposed framework with highly impressive reliability and robustness in identifying different HGs, suggesting it's potential application for remote condition monitoring of outdoor polymeric insulators.
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 5251-5260
Condition Monitoring of Polymeric Insulators: A Remote Diagnostic Framework With Improved Intermediate Hydrophobicity Grade Detection
Polymeric insulators deliver superior pollution performance owing to their excellent hydrophobic characteristics. However, due to aging, temporary loss of hydrophobicity occurs and continuous water films start to form, leading to dry-band arcing and subsequently, flashover of the insulators. Hence, accurate identification of different hydrophobicity grades (HGs) is essential. Considering this issue, a novel image visibility theory-aided remote HG detection framework with improved intermediate HG identification has been proposed in this contribution. To achieve this, image visibility patches (VPs) were extracted to quantify the intricate pixel-level alterations taking place particularly for the intermediate HGs. In addition, the concept of uniform visibility patches is proposed to reduce computational burden of the conventional VP extraction process along with providing additional noise resiliency. The employed HG detection methodology infused with a transformer encoder-based classifier module was trained on experimental HG images acquired from an 11kV silicone rubber (SiR) insulator and tested on benchmark data utilizing a cross-dataset learning strategy, which yielded satisfactorily high HG detection performance, Ablation study in addition to comparison with existing studies revealed superior efficiency of the proposed framework with highly impressive reliability and robustness in identifying different HGs, suggesting it's potential application for remote condition monitoring of outdoor polymeric insulators.
- 27 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2077-2092
Robustness Assessment of Distributed Optimal Power Flow Under Communication Non-Idealities
In recent years, distributed optimal power flow (OPF) algorithms have found applications to distribution system operations. These algorithms decompose the system into small areas, each solving a local optimization problem and periodically sharing boundary variable values with neighbors. Unlike centralized approaches, the performance of distributed algorithms is significantly affected by non-ideal communication conditions. This article assesses the performance of a fast distributed algorithm, named Equivalent Network Approximation method (ENApp), for three-phase radial distribution system under four different non-ideal communication scenarios, erroneous data transfer, packet loss, additive noise effect, and communication delays. First, the paper proposes ENApp-based distributed OPF algorithms for normal and stressed main grid conditions. Communication non-idealities are considering the physical aspects of two widely used wide-area network mediums, viz. power line communication and optical fiber. The performance is evaluated using the IEEE 123 bus test system in a cyber-physical co-simulation environment based on the Hierarchical Engine for Large-scale Infrastructure Co-Simulation (HELICS), providing insights into ENApp's robustness in terms of convergence time and success rate.
- 27 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2077-2092
Robustness Assessment of Distributed Optimal Power Flow Under Communication Non-Idealities
In recent years, distributed optimal power flow (OPF) algorithms have found applications to distribution system operations. These algorithms decompose the system into small areas, each solving a local optimization problem and periodically sharing boundary variable values with neighbors. Unlike centralized approaches, the performance of distributed algorithms is significantly affected by non-ideal communication conditions. This article assesses the performance of a fast distributed algorithm, named Equivalent Network Approximation method (ENApp), for three-phase radial distribution system under four different non-ideal communication scenarios, erroneous data transfer, packet loss, additive noise effect, and communication delays. First, the paper proposes ENApp-based distributed OPF algorithms for normal and stressed main grid conditions. Communication non-idealities are considering the physical aspects of two widely used wide-area network mediums, viz. power line communication and optical fiber. The performance is evaluated using the IEEE 123 bus test system in a cyber-physical co-simulation environment based on the Hierarchical Engine for Large-scale Infrastructure Co-Simulation (HELICS), providing insights into ENApp's robustness in terms of convergence time and success rate.
- Open Access
- 17 January 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 157
A new iterative mixed integer linear programming based real time energy efficient management of AC-DC distribution networks
- 17 January 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 157
Open AccessA new iterative mixed integer linear programming based real time energy efficient management of AC-DC distribution networks
- Open Access
- 21 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Impact Assessment of Weather Dependent Dynamic Transmission Line Capacity on Renewable Penetration in an Indian Transmission Grid
The electricity demand is increasing day by day and that is exhausting limited conventional energy resources rapidly. Thus, renewable energy is becoming very attractive source of electricity to meet the load and prevent the global warming threat. The challenges in integration of renewable energy sources are its intermittency and old existing power system infrastructure. Renewable energy sources collocated with energy storage facilities can mitigate the effect of renewable energy uncertainty. However, high penetration of green energy is only possible by upgrading the existing power system network. Most of the time transmission lines are under loaded from its actual power handling capacity, as worst possible power handling capacity of line is considered while scheduling power to generators. Actual power capacity of line depends on many environmental factors and changes accordingly with the weather conditions. This article elucidates the impact of weather variation on economic operation of a practical Indian 75 bus power system network placed at Uttar Pradesh, India. The simulation is carried out by accounting the proposed solar power plants in that region and the effect of dynamic line rating on renewable curtailment, thermal power fuel cost and line congestion has been studied.
- 21 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessImpact Assessment of Weather Dependent Dynamic Transmission Line Capacity on Renewable Penetration in an Indian Transmission Grid
The electricity demand is increasing day by day and that is exhausting limited conventional energy resources rapidly. Thus, renewable energy is becoming very attractive source of electricity to meet the load and prevent the global warming threat. The challenges in integration of renewable energy sources are its intermittency and old existing power system infrastructure. Renewable energy sources collocated with energy storage facilities can mitigate the effect of renewable energy uncertainty. However, high penetration of green energy is only possible by upgrading the existing power system network. Most of the time transmission lines are under loaded from its actual power handling capacity, as worst possible power handling capacity of line is considered while scheduling power to generators. Actual power capacity of line depends on many environmental factors and changes accordingly with the weather conditions. This article elucidates the impact of weather variation on economic operation of a practical Indian 75 bus power system network placed at Uttar Pradesh, India. The simulation is carried out by accounting the proposed solar power plants in that region and the effect of dynamic line rating on renewable curtailment, thermal power fuel cost and line congestion has been studied.
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 138-147
Multi-Objective Energy Management of a Smart Home in Real Time Environment
In home energy management, the occupants schedule the operating appliances to achieve lowest optimal energy cost with minimum discomfort. Smart home energy management turns out to be challenging due to the penetration of rooftop intermittent solar power generations. This article develops a multi-objective and real time smart residential load management and hence energy management topology considering variation in rooftop solar power generation with variation in price of distribution grid energy. Primarily, the optimization problem is established as a time average stochastic optimization formulation and then simplified to mixed integer linear programming (MILP) using Lyapunov optimization. The energy cost minimization objective is added with ocular and thermal discomfort minimization which also lowers the discomfort level for occupants due to actions caused by real time load management. The home loads are managed by an Internet-of-Things (IoT) based controller which also alerts the occupants for any incipient malfunction in the household loads. The proposed control technique is authenticated on a real-life smart residential data with simulations and experiments. The resultant controller can thus optimally control the smart residential loads in real time.
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 138-147
Multi-Objective Energy Management of a Smart Home in Real Time Environment
In home energy management, the occupants schedule the operating appliances to achieve lowest optimal energy cost with minimum discomfort. Smart home energy management turns out to be challenging due to the penetration of rooftop intermittent solar power generations. This article develops a multi-objective and real time smart residential load management and hence energy management topology considering variation in rooftop solar power generation with variation in price of distribution grid energy. Primarily, the optimization problem is established as a time average stochastic optimization formulation and then simplified to mixed integer linear programming (MILP) using Lyapunov optimization. The energy cost minimization objective is added with ocular and thermal discomfort minimization which also lowers the discomfort level for occupants due to actions caused by real time load management. The home loads are managed by an Internet-of-Things (IoT) based controller which also alerts the occupants for any incipient malfunction in the household loads. The proposed control technique is authenticated on a real-life smart residential data with simulations and experiments. The resultant controller can thus optimally control the smart residential loads in real time.
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (11) , 7444-7453
Residential Appliance Identification Using 1-D Convolutional Neural Network Based on Multiscale Sinusoidal Initializers
Appliance identification and classification are primary requirement for successful deployment of demand side management in smart grid. Traditionally, load identification is carried out after extracting handcrafted features from electrical signals followed by classification algorithms, which is laborious and time consuming. To nullify the abovementioned shortcomings, this article proposes a 1-D convolutional neural network (CNN) with sinusoidal kernel initializers for classification of domestic appliances operating individually or in combination with other devices. For efficient operation, 15 primary and 225 multiscale sinusoidal kernels (MSK) are formed and included in the CNN architecture for extracting important discriminative features from the current signals. Classification accuracy of the proposed CNN module, named as MSK-CNN, is further improved by adding a new nonlinear activation function (AF), SL-ReLU, having an adjustable logarithmic function along with softsign and ReLU functions. The efficacy of MSK-CNN is tested on a practical dataset, created by the authors, consists current signals of different real life residential appliances. It is showed that MSK-CNN can successfully distinguish 18 single and 12 appliance combinations, and can attain an accuracy of 98.61%. The experimental outcomes reveal superiority of the MSK-CNN over classical CNN modules with other kernel initializers and AFs in terms of classification accuracy and training convergence.
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (11) , 7444-7453
Residential Appliance Identification Using 1-D Convolutional Neural Network Based on Multiscale Sinusoidal Initializers
Appliance identification and classification are primary requirement for successful deployment of demand side management in smart grid. Traditionally, load identification is carried out after extracting handcrafted features from electrical signals followed by classification algorithms, which is laborious and time consuming. To nullify the abovementioned shortcomings, this article proposes a 1-D convolutional neural network (CNN) with sinusoidal kernel initializers for classification of domestic appliances operating individually or in combination with other devices. For efficient operation, 15 primary and 225 multiscale sinusoidal kernels (MSK) are formed and included in the CNN architecture for extracting important discriminative features from the current signals. Classification accuracy of the proposed CNN module, named as MSK-CNN, is further improved by adding a new nonlinear activation function (AF), SL-ReLU, having an adjustable logarithmic function along with softsign and ReLU functions. The efficacy of MSK-CNN is tested on a practical dataset, created by the authors, consists current signals of different real life residential appliances. It is showed that MSK-CNN can successfully distinguish 18 single and 12 appliance combinations, and can attain an accuracy of 98.61%. The experimental outcomes reveal superiority of the MSK-CNN over classical CNN modules with other kernel initializers and AFs in terms of classification accuracy and training convergence.
- 1 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Recognition of Hydrophobicity Class of Polymeric Insulators Employing Residual Morphological Neural Network and Granulometry-Based Image Analysis
Hydrophobicity is an important property of polymeric insulators which allow formation of discrete water droplets on the insulator surface. However, with aging or under extreme humidification, the insulator surface loses its hydrophobic property, resulting in continuous water channel formation, which may lead to dry band arcing and subsequently flashover, thereby affecting the long-term performance of the insulator. Therefore, accurate recognition of hydrophobic class (HC) is important as it provides information regarding the surface condition of the insulator. Considering the above-said facts, this article investigates the feasibility of employing residual morphological neural network (Res-Morph-NN) to accurately recognize different HC of polymeric insulators. In addition, for better understanding of the distribution of water droplets on the insulator surface, a novel approach based on multiscale mathematical morphology viz. granulometry is used in this article. Our investigations revealed significant alterations in the granulometric patterns with the change in HC of polymeric insulators. The efficacy of the proposed framework employing Res-Morph-NN has been validated on HC images obtained from experiment as well as on large set of images obtained from an online database, which returned satisfactory results. The proposed method can be efficiently used to discriminate different hydrophobicity classes which can be implemented for monitoring insulator surface condition in real time.
- 1 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Recognition of Hydrophobicity Class of Polymeric Insulators Employing Residual Morphological Neural Network and Granulometry-Based Image Analysis
Hydrophobicity is an important property of polymeric insulators which allow formation of discrete water droplets on the insulator surface. However, with aging or under extreme humidification, the insulator surface loses its hydrophobic property, resulting in continuous water channel formation, which may lead to dry band arcing and subsequently flashover, thereby affecting the long-term performance of the insulator. Therefore, accurate recognition of hydrophobic class (HC) is important as it provides information regarding the surface condition of the insulator. Considering the above-said facts, this article investigates the feasibility of employing residual morphological neural network (Res-Morph-NN) to accurately recognize different HC of polymeric insulators. In addition, for better understanding of the distribution of water droplets on the insulator surface, a novel approach based on multiscale mathematical morphology viz. granulometry is used in this article. Our investigations revealed significant alterations in the granulometric patterns with the change in HC of polymeric insulators. The efficacy of the proposed framework employing Res-Morph-NN has been validated on HC images obtained from experiment as well as on large set of images obtained from an online database, which returned satisfactory results. The proposed method can be efficiently used to discriminate different hydrophobicity classes which can be implemented for monitoring insulator surface condition in real time.