DBDiomidis Botsikas

Diomidis Botsikas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Diomidis Botsikas has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diffusion-Weighted MRI in the Genitourinary System

    by Thomas De Perrot, Christine Sadjo Zoua, Carl G. Glessgen, Diomidis Botsikas, Lena Berchtold, Rares Salomir, Sophie De Seigneux, Harriet C. Thoeny, Jean-Paul Vallée

    Diffusion weighted imaging (DWI) constitutes a major functional parameter performed in Magnetic Resonance Imaging (MRI). The DW sequence is performed by acquiring a set of native images described by their b-values, each b-value representing the strength of the diffusion MR gradients specific to that sequence. By fitting the data with models describing the motion of water in tissue, an apparent diffusion coefficient (ADC) map is built and allows the assessment of water mobility inside the tissue. The high cellularity of tumors restricts the water diffusion and decreases the value of ADC within tumors, which makes them appear hypointense on ADC maps. The role of this sequence now largely exceeds its first clinical apparitions in neuroimaging, whereby the method helped diagnose the early phases of cerebral ischemic stroke. The applications extend to whole-body imaging for both neoplastic and non-neoplastic diseases. This review emphasizes the integration of DWI in the genitourinary system imaging by outlining the sequence’s usage in female pelvis, prostate, bladder, penis, testis and kidney MRI. In gynecologic imaging, DWI is an essential sequence for the characterization of cervix tumors and endometrial carcinomas, as well as to differentiate between leiomyosarcoma and benign leiomyoma of the uterus. In ovarian epithelial neoplasms, DWI provides key information for the characterization of solid components in heterogeneous complex ovarian masses. In prostate imaging, DWI became an essential part of multi-parametric Magnetic Resonance Imaging (mpMRI) to detect prostate cancer. The Prostate Imaging–Reporting and Data System (PI-RADS) scoring the probability of significant prostate tumors has significantly contributed to this success. Its contribution has established mpMRI as a mandatory examination for the planning of prostate biopsies and radical prostatectomy. Following a similar approach, DWI was included in multiparametric protocols for the bladder and the testis. In renal imaging, DWI is not able to robustly differentiate between malignant and benign renal tumors but may be helpful to characterize tumor subtypes, including clear-cell and non-clear-cell renal carcinomas or low-fat angiomyolipomas. One of the most promising developments of renal DWI is the estimation of renal fibrosis in chronic kidney disease (CKD) patients. In conclusion, DWI constitutes a major advancement in genitourinary imaging with a central role in decision algorithms in the female pelvis and prostate cancer, now allowing promising applications in renal imaging or in the bladder and testicular mpMRI.


  • Pelvic MRI for Endometriosis: A Diagnostic Challenge for the Inexperienced Radiologist. How Much Experience Is Enough?

    by Clemence Bruyere, Ioanna Maniou, Céline Habre, Anastasia Kalovidouri, Nicola Pluchino, Xavier Montet, Diomidis Botsikas


  • Cell Spillage after Contained Electromechanical Morcellation Using a Specially Designed In-Bag System for Laparoscopic Myomectomy: Prospective Cohort Pilot Study

    by Shahzia Lambat Emery, Nicola Pluchino, Patrick Petignat, Jean-Christophe Tille, Jean-Claude Pache, Joana Pinto, Diomidis Botsikas, Jean Dubuisson


  • What is the diagnostic performance of 18-FDG-PET/MR compared to PET/CT for the N- and M- staging of breast cancer?

    by Diomidis Botsikas, Ilias Bagetakos, Marlise Picarra, Ana Carolina Da Cunha Afonso Barisits, Sana Boudabbous, Xavier Montet, Giang Thanh Lam, Ismini Mainta, Anastasia Kalovidouri, Minerva Becker

    To compare the diagnostic performance of 18-FDG-PET/MR and PET/CT for the N- and M- staging of breast cancer.


  • Open Access

    Evaluating the effect of increased pitch, iterative reconstruction and dual source CT on dose reduction and image quality

    by Joanna Gariani, Steve P Martin, Diomidis Botsikas, Christoph D Becker, Xavier Montet

    Objective:to compare radiation dose and image quality of thoraco-abdominal scans obtained with a high-pitch protocol (pitch 3.2) and iterative reconstruction (SAFIRE) in comparison to standard pitch reconstructed with FBP using dual-source CT.Methods:114 CT scans (Somatom Definition Flash, Siemens), 39 thoracic scans, 54 thoraco-abdominal scans and 21 abdominal scans were performed. Analysis of three protocols was undertaken; pitch of 1 reconstructed with FBP, pitch of 3.2 reconstructed with SAFIRE, pitch of 3.2 with stellar detectors reconstructed with SAFIRE. Objective and subjective image analysis was performed. Dose differences of the protocols used were compared.Results:Dose was reduced when comparing scans with a pitch of 1 reconstructed with FBP to high pitch scans with a pitch of 3.2 reconstructed with SAFIRE with a reduction of CTDIvol of 75% for thoracic scans, 64% for thoraco-abdominal scans and 67% for abdominal scans. There was a further reduction after the implementation of stellar detectors...


  • Clitoral Anatomy, Physiology and Pathology Demystified by Imaging

    by Diomidis Botsikas, Amal Djema, Marlise Picarra, Patrick Petignat, Xavier Montet, Benedicte Delattre, Karen Kinkel, Jasmine Abdulcadir

    Background: Clitoris is an organ, whose only known function is sexual pleasure. Clinically, clitoris is only partially visible. Therefore medical imaging is important for studying it. Objective: Knowledge of radiologic anatomy and variations of the clitoris is useful for studying female sexual function, understanding it's pathological conditions and planning clitoral surgical interventions. Discussion: Anatomy of clitoris is complex with an external part, including the glans and a body and an internally lying part, the crura, in contact with vestibular bulbs. Ultrasound offers high spatial resolution and possibility of dynamic assessment allowing optimal exploration of the superficial parts of the organ. MRI is the imaging modality of choice for investigating anatomy of the whole organ, including its' deep-lying parts. It has excellent soft tissue contrast and the possibility of imaging in all planes. Conclusion: In this article, are presented imaging methods assessing normal clitoral anatomy and physiology, as well as the main pathological conditions of the organ as assessed by imaging.


  • CT vaginography: a new CT technique for imaging of upper and middle vaginal fistulas

    by Diomidis Botsikas, Nicola Pluchino, Anastasia Kalovidouri, Alexandra Platon, Xavier Montet, Patrick Dallenbach, Pierre-Alexandre Poletti

    Different types of vaginal fistulas is a relatively uncommon condition in the Western world but very frequent in developing countries. In the past, conventional vaginography was the radiological examination of choice for exploring this condition. CT and MRI are now both used for this purpose. Our objective was to test the feasibility and to explore the potential role of a new CT imaging technique implementing vaginal introitus obstruction and opacification of the vagina with iodine contrast agent, to show patency of a fistula. We describe the technical protocol of CT-vaginography as performed in Geneva University Hospitals, including vaginal catheterization with a Foley catheter and obstruction of the introitus by inflating the balloon of the catheter. We also report three cases of patients with suspected vaginal fistula who underwent CT-vaginography. The examinations were technically successful. In one patient, it revealed the presence of fistulous pathways from the vaginal fornix along the bilateral infected surgical prostheses. In a second patient, it showed a fistula between the vagina and the necrotic cavity of a recurrent cervical cancer. In a third patient, it proved the absence of a suspected vaginal fistula. CT-vaginography is a technically feasible CT protocol that provides anatomical and functional information on clinically suspected vaginal fistulas. After the abandon of conventional vaginography in the era of transaxial imaging, the current modalities of imaging vaginal fistulas provide excellent anatomical detail but less functional information concerning the permeability of a vaginal fistulous pathway. We propose the use of CT-vaginography, a technical protocol that we describe in detail.


  • Open Access

    Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction

    by Diomidis Botsikas, Isabelle Barnaure, Sylvain Terraz, Christoph D Becker, Anastasia Kalovidouri, Xavier Montet

    AIM: To evaluate the image quality of hepatic multidetector computed tomography (MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/mL (Visipaque 270) and 80 kVp acquisitions reconstructed with sinogram affirmed iterative reconstruction (SAFIRE®) in comparison with a standard MDCT protocol. Fifty-three consecutive patients with known or suspected hepatocellular carcinoma underwent 55 CT examinations, with two different four-phase CT protocols. The first group of 30 patients underwent a standard 120 kVp acquisition after injection of Iohexol 350 mg/mL (Accupaque 350®) and reconstructed with filtered back projection. The second group of 25 patients underwent a dual-energy CT at 80-140 kVp with iodixanol 270. The 80 kVp component of the second group was reconstructed iteratively (SAFIRE®-Siemens). All hyperdense and hypodense hepatic lesions ≥ 5 mm were identified with both protocols. Aorta and portal vessels/liver parenchyma contrast to noise ratio (CNR) in arterial phase, hypervascular lesion/liver parenchyma CNR in arterial phase, hypodense lesion/liver parenchyma CNR in portal and late phase were calculated in both groups. RESULTS: Aorta/liver and focal lesions altogether/liver CNR were higher for the second protocol (P = 0.0078 and 0.0346). Hypervascular lesions/liver CNR was not statistically different (P = 0.86). Hypodense lesion/liver CNR in the portal phase was significantly higher for the second group (P = 0.0107). Hypodense lesion/liver CNR in the late phase was the same for both groups (P = 0.9926). CONCLUSION: MDCT imaging with 80 kVp with iterative reconstruction and iodixanol 270 yields equal or even better image quality.


  • Clinical utility of 18F-FDG-PET/MR for preoperative breast cancer staging

    by Diomidis Botsikas, Anastasia Kalovidouri, Minerva Becker, Michele Copercini, Dahila Amal Djema, Alexandre Bodmer, Sindy Monnier, Christoph D. Becker, Xavier Montet, Benedicte M. A. Delattre, et al.

    To evaluate the performance of 18F-fluorodeoxyglucose (FDG) positron emission tomography magnetic resonance imaging (PET/MR) for preoperative breast cancer staging.


  • Image quality of low mA CT pulmonary angiography reconstructed with model based iterative reconstruction versus standard CT pulmonary angiography reconstructed with filtered back projection: an equivalency trial

    by Xavier Montet, Anne-Lise Hachulla, Angeliki Neroladaki, Frederic Lador, Thierry Rochat, Diomidis Botsikas, Christoph D. Becker

    To determine whether CT pulmonary angiography (CTPA) using low mA setting reconstructed with model-based iterative reconstruction (MBIR) is equivalent to routine CTPA reconstructed with filtered back projection (FBP). This prospective study was approved by the institutional review board and patients provided written informed consent. Eighty-two patients were examined with a low mA MBIR-CTPA (100 kV, 20 mA) and 82 patients with a standard FBP-CTPA (100 kV, 250 mA). Region of interests were drawn in nine pulmonary vessels; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate the image quality of FBP-CTPA and low mA MBIR-CTPA. Compared to routine FBP-CTPA, low mA MBIR-CTPA showed no differences in the attenuation measured in nine pulmonary vessels, higher SNR (56 ± 19 vs 43 ± 20, p p p 2. Low mA MBIR-CTPA is equivalent to routine FBP-CTPA and allows a significant dose reduction while improving SNR and CNR in the pulmonary vessels, as compared with routine FBP-CTPA. • Low mA MBIR-CTPA is equivalent to routine FBP-CTPA. • MBIR-CTPA may be achieved with drastic (93 %) dose reduction. • Low mA MBIR-CTPA should be studied in the setting of suspected PE.