Andrew Trigg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andrew Trigg has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
- Berend Terluin
Department of General Practice, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
5 shared publications - Jakob Bue Bjorner
QualityMetric and IQVIA Company, Johnston, USA
5 shared publications - Caroline Barbara Terwee
Department of Epidemiology and Data Science, Amsterdam Public Health Research Institute, Amsterdam UMC, Vrije Universiteit Amsterdam, the Netherlands
3 shared publications - Christian Seitz
Bayer AG, Berlin, Germany
3 shared publications Christoph Gerlinger
Bayer AG, Berlin, Germany
3 shared publicationsClaudia Haberland
Bayer AG, Berlin, Germany
3 shared publications
Latest Publications
- Open Access
- 25 November 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Performance and comparative analysis of the touchless home sleep monitor Sleepiz One+ with polysomnography in women with sleep disturbance associated with menopause (Preprint)
BACKGROUND Sleep disturbances can affect up to 60% of postmenopausal women and can have a profound impact on quality of life, mental health, and physical health. Polysomnography (PSG) conducted within a sleep laboratory is the reference standard for assessing sleep disturbance, however, it has several limitations. Home sleep monitors, such as the contactless Sleepiz One+ device, counter some limitations of in-lab PSG and provide valuable insights into sleep health, as well as the variability of sleep between nights, due to longitudinal measures in the user’s natural sleep environment at home. It is important to gain insight into the level of agreement between PSG and Sleepiz One+ to identify its suitability for use in future clinical trials assessing sleep disturbances in a clinically relevant population. OBJECTIVE To assess the performance of Sleepiz One+ compared with reference standard in-lab PSG and further evaluate Sleepiz One+ as a home-based sleep monitoring tool for measuring sleep disturbance associated with menopause. METHODS Agreement between modalities was exploratorily assessed using epoch-level (sleep/wake classification in 30-second intervals) and sleep parameter-level analyses using data from postmenopausal women with sleep disturbances who participated in the randomized NIRVANA Phase II trial (NCT06112756). Synchronized PSG and Sleepiz One+ assessments were conducted over 3 visits (6 nights total) within a laboratory setting, and Sleepiz One+ data were also collected nightly in the participant’s home over a period of 12-weeks. RESULTS Epoch-level classification of sleep/wake status by Sleepiz One+ was mostly consistent across nights. In 237,258 epochs from 66 subjects, sensitivity (to detect sleep), specificity (to detect wake), accuracy, and inter-device reliability (prevalence-adjusted bias-adjusted kappa [PABAK]) in comparison to PSG were estimated to be 91%, 64%, 86%, and 0.72, respectively. Mean differences between Sleepiz One+ and PSG at the parameter-level were: wakefulness after sleep onset (WASO) −4.8 minutes; sleep efficiency (SE) +2.1%; number of awakenings (NAW) −0.4. Negative values indicated underestimation by Sleepiz One+ and positive indicated overestimation. Test-retest reliability was high (intraclass correlation coefficients: WASO 0.91–0.96; SE 0.87–0.98; NAW 0.94–0.97), with ≥4 nights per week recommended to yield a weekly average. CONCLUSIONS Sleepiz One+ is a reliable tool for sleep assessment in clinical trials with comparable performance to PSG, addressing the unmet need for longitudinal monitoring of natural sleep at-home, and should be considered for future studies assessing menopause-associated sleep disturbance. CLINICALTRIAL A Study to Learn About How Elinzanetant Works and How Safe it is in Women Having Sleep Disturbances Associated With Menopause (NIRVANA), Phase II, randomized clinical trial, NCT06112756, study registration date 2023-10-27, https://clinicaltrials.gov/study/NCT06112756
- 25 November 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessPerformance and comparative analysis of the touchless home sleep monitor Sleepiz One+ with polysomnography in women with sleep disturbance associated with menopause (Preprint)
BACKGROUND Sleep disturbances can affect up to 60% of postmenopausal women and can have a profound impact on quality of life, mental health, and physical health. Polysomnography (PSG) conducted within a sleep laboratory is the reference standard for assessing sleep disturbance, however, it has several limitations. Home sleep monitors, such as the contactless Sleepiz One+ device, counter some limitations of in-lab PSG and provide valuable insights into sleep health, as well as the variability of sleep between nights, due to longitudinal measures in the user’s natural sleep environment at home. It is important to gain insight into the level of agreement between PSG and Sleepiz One+ to identify its suitability for use in future clinical trials assessing sleep disturbances in a clinically relevant population. OBJECTIVE To assess the performance of Sleepiz One+ compared with reference standard in-lab PSG and further evaluate Sleepiz One+ as a home-based sleep monitoring tool for measuring sleep disturbance associated with menopause. METHODS Agreement between modalities was exploratorily assessed using epoch-level (sleep/wake classification in 30-second intervals) and sleep parameter-level analyses using data from postmenopausal women with sleep disturbances who participated in the randomized NIRVANA Phase II trial (NCT06112756). Synchronized PSG and Sleepiz One+ assessments were conducted over 3 visits (6 nights total) within a laboratory setting, and Sleepiz One+ data were also collected nightly in the participant’s home over a period of 12-weeks. RESULTS Epoch-level classification of sleep/wake status by Sleepiz One+ was mostly consistent across nights. In 237,258 epochs from 66 subjects, sensitivity (to detect sleep), specificity (to detect wake), accuracy, and inter-device reliability (prevalence-adjusted bias-adjusted kappa [PABAK]) in comparison to PSG were estimated to be 91%, 64%, 86%, and 0.72, respectively. Mean differences between Sleepiz One+ and PSG at the parameter-level were: wakefulness after sleep onset (WASO) −4.8 minutes; sleep efficiency (SE) +2.1%; number of awakenings (NAW) −0.4. Negative values indicated underestimation by Sleepiz One+ and positive indicated overestimation. Test-retest reliability was high (intraclass correlation coefficients: WASO 0.91–0.96; SE 0.87–0.98; NAW 0.94–0.97), with ≥4 nights per week recommended to yield a weekly average. CONCLUSIONS Sleepiz One+ is a reliable tool for sleep assessment in clinical trials with comparable performance to PSG, addressing the unmet need for longitudinal monitoring of natural sleep at-home, and should be considered for future studies assessing menopause-associated sleep disturbance. CLINICALTRIAL A Study to Learn About How Elinzanetant Works and How Safe it is in Women Having Sleep Disturbances Associated With Menopause (NIRVANA), Phase II, randomized clinical trial, NCT06112756, study registration date 2023-10-27, https://clinicaltrials.gov/study/NCT06112756
- Open Access
- 19 September 2026
- Published by Springer Nature in Journal of Patient-Reported Outcomes
Psychometric evaluation of the PROMIS SD SF 8b and ISI for sleep disturbances associated with menopause
Background: Sleep disturbances are common and impactful symptoms associated with menopause, negatively affecting women’s quality of life. Reliable and valid patient-reported outcome (PRO) instruments are needed to assess menopause-associated sleep disturbances in clinical trials. This study aimed to evaluate the psychometric properties of the PROMIS Sleep Disturbance Short Form 8b (PROMIS SD SF 8b) and Insomnia Severity Index (ISI) for this specific context of use. Methodology: Measurement properties of the PROMIS SD SF 8b and ISI scores were assessed using data ( n = 110 participants) from a randomized, placebo-controlled, phase 2 study evaluating the efficacy and safety of elinzanetant for the treatment of sleep disturbances associated with menopause. Analyses included assessments of distributional properties, reliability (test-retest/score stability, internal consistency), validity (inter-item correlations, dimensionality, convergent/divergent, and known-groups), responsiveness to change, and minimal detectable change (MDC90). Results: PROMIS SD SF 8b and ISI completion rates were generally high. No floor or ceiling effects were observed. For the PROMIS SD SF 8b T-score, test-retest reliability was excellent (intraclass correlation coefficients (ICCs) = 0.91), and acceptable internal consistency reliability was observed (Cronbach’s alpha = 0.91–0.94). The ISI total score showed good reproducibility among participants classified as stable between Weeks 4 and 12 (ICC = 0.82), and acceptable internal consistency reliability (Cronbach’s alpha = 0.86–0.88). Both scores demonstrated unidimensionality and mostly met convergent and divergent hypotheses for validity. Differences were observed between clinically distinct subgroups defined by Patient Global Impression of Severity items for severity of sleep problems and time spent awake ( p < 0.0001). Responsiveness analyses indicated both instruments could detect change, with large effect sizes in improved groups and correlations consistent with predefined hypotheses. MDC90 was 3.89 for the PROMIS SD SF 8b T-score and 3.99 for the ISI total score; individual changes exceeding these thresholds likely represent true change rather than measurement error. Conclusions: Our findings support the reliability, validity and responsiveness of PROMIS SD SF 8b T-score and ISI total score for assessing sleep disturbances in women experiencing menopause. These findings support their use to assess clinical trial endpoints in this population and highlight the value of evaluating established PRO measures when applied in new contexts of use.
- 19 September 2026
- Published by Springer Nature in Journal of Patient-Reported Outcomes
Open AccessPsychometric evaluation of the PROMIS SD SF 8b and ISI for sleep disturbances associated with menopause
Background: Sleep disturbances are common and impactful symptoms associated with menopause, negatively affecting women’s quality of life. Reliable and valid patient-reported outcome (PRO) instruments are needed to assess menopause-associated sleep disturbances in clinical trials. This study aimed to evaluate the psychometric properties of the PROMIS Sleep Disturbance Short Form 8b (PROMIS SD SF 8b) and Insomnia Severity Index (ISI) for this specific context of use. Methodology: Measurement properties of the PROMIS SD SF 8b and ISI scores were assessed using data ( n = 110 participants) from a randomized, placebo-controlled, phase 2 study evaluating the efficacy and safety of elinzanetant for the treatment of sleep disturbances associated with menopause. Analyses included assessments of distributional properties, reliability (test-retest/score stability, internal consistency), validity (inter-item correlations, dimensionality, convergent/divergent, and known-groups), responsiveness to change, and minimal detectable change (MDC90). Results: PROMIS SD SF 8b and ISI completion rates were generally high. No floor or ceiling effects were observed. For the PROMIS SD SF 8b T-score, test-retest reliability was excellent (intraclass correlation coefficients (ICCs) = 0.91), and acceptable internal consistency reliability was observed (Cronbach’s alpha = 0.91–0.94). The ISI total score showed good reproducibility among participants classified as stable between Weeks 4 and 12 (ICC = 0.82), and acceptable internal consistency reliability (Cronbach’s alpha = 0.86–0.88). Both scores demonstrated unidimensionality and mostly met convergent and divergent hypotheses for validity. Differences were observed between clinically distinct subgroups defined by Patient Global Impression of Severity items for severity of sleep problems and time spent awake ( p < 0.0001). Responsiveness analyses indicated both instruments could detect change, with large effect sizes in improved groups and correlations consistent with predefined hypotheses. MDC90 was 3.89 for the PROMIS SD SF 8b T-score and 3.99 for the ISI total score; individual changes exceeding these thresholds likely represent true change rather than measurement error. Conclusions: Our findings support the reliability, validity and responsiveness of PROMIS SD SF 8b T-score and ISI total score for assessing sleep disturbances in women experiencing menopause. These findings support their use to assess clinical trial endpoints in this population and highlight the value of evaluating established PRO measures when applied in new contexts of use.
- Open Access
- 9 January 2026
- Published by Springer Nature in Quality of Life Research
- Vol. 35 (2) , 39
Estimating the minimal important change of single-item measures using the adjusted predictive modeling method or the longitudinal confirmatory factor analysis method
Purpose: Recently developed minimal important change (MIC) estimation methods recover the mean individual MIC in a sample. These methods are the adjusted predictive modeling (APM) method and the longitudinal confirmatory factor analysis (LCFA) method. Both methods require LCFA of patient-reported outcome measure (PROM) data. In the APM-method, LCFA is used to estimate the reliability of the transition ratings, whereas in the LCFA-method, LCFA is used to estimate the latent MIC. However, LCFA cannot be performed if the PROM is a single item measure (SIM). Adding an auxiliary variable, that is correlated with the PROM, to the LCFA-model may be a solution. We developed three different LCFA-models in which an auxiliary variable is included. In this simulation study, we assessed the performance of the APM- and LCFA-methods to recover the true MIC of an SIM. We applied both methods to a real dataset in which the SIM was a numeric rating scale for pain. Methods: We simulated 15,552 samples, varying in 11 parameters, and estimated the APM-based and LCFA-based MICs. Results: The APM-method performed well, except if the proportion improved was high or low, and the present state bias (PSB) was high. The LCFA-method performed well, irrespective of the proportion improved and the PSB. In the real data, the LCFA-based MIC was 17 (on a 100-point scale), whereas the estimated APM-based MIC was 4 points higher, probably due to a high proportion improved and a high PSB. Conclusion: The MIC of an SIM can be accurately estimated using an auxiliary PROM.
- 9 January 2026
- Published by Springer Nature in Quality of Life Research
- Vol. 35 (2) , 39
Open AccessEstimating the minimal important change of single-item measures using the adjusted predictive modeling method or the longitudinal confirmatory factor analysis method
Purpose: Recently developed minimal important change (MIC) estimation methods recover the mean individual MIC in a sample. These methods are the adjusted predictive modeling (APM) method and the longitudinal confirmatory factor analysis (LCFA) method. Both methods require LCFA of patient-reported outcome measure (PROM) data. In the APM-method, LCFA is used to estimate the reliability of the transition ratings, whereas in the LCFA-method, LCFA is used to estimate the latent MIC. However, LCFA cannot be performed if the PROM is a single item measure (SIM). Adding an auxiliary variable, that is correlated with the PROM, to the LCFA-model may be a solution. We developed three different LCFA-models in which an auxiliary variable is included. In this simulation study, we assessed the performance of the APM- and LCFA-methods to recover the true MIC of an SIM. We applied both methods to a real dataset in which the SIM was a numeric rating scale for pain. Methods: We simulated 15,552 samples, varying in 11 parameters, and estimated the APM-based and LCFA-based MICs. Results: The APM-method performed well, except if the proportion improved was high or low, and the present state bias (PSB) was high. The LCFA-method performed well, irrespective of the proportion improved and the PSB. In the real data, the LCFA-based MIC was 17 (on a 100-point scale), whereas the estimated APM-based MIC was 4 points higher, probably due to a high proportion improved and a high PSB. Conclusion: The MIC of an SIM can be accurately estimated using an auxiliary PROM.
- Open Access
- 12 July 2025
- Published by Springer Nature in The Patient - Patient-Centered Outcomes Research
- Vol. 18 (6) , 687-697
Exit Interviews Examining Changes to Mood and Work/Productivity Impacts Related to Vasomotor Symptoms: Perspectives of Postmenopausal Women Receiving Elinzanetant in Phase III Clinical Trials
Background Vasomotor symptoms (VMS; hot flashes) significantly impact women’s health-related quality of life during the menopausal transition. Two phase III trials (OASIS 1 and 2) were conducted to investigate the efficacy and safety of elinzanetant for the treatment of moderate-to-severe VMS associated with menopause. This exit interview study explored the impact of VMS on women’s mood and work/productivity before and since treatment. Methods A total of 40 postmenopausal women from the USA who participated in OASIS 1 and 2 (receiving elinzanetant for 26 weeks or placebo for 12 weeks followed by elinzanetant for 14 weeks) took part in a 60-min exit interview. Interviews were conducted via telephone by trained qualitative interviewers using a semi-structured interview guide; concept-elicitation techniques, followed by focused questioning, were used to explore concepts of interest. Interview transcripts were analyzed using thematic analysis methods in Atlas.ti. Saturation analysis was conducted to determine the appropriateness of the sample size. Results Twelve mood concepts and seven work/productivity concepts were reported to be associated with VMS before taking the study medication. Most commonly reported mood concepts included reduced happiness (60.0%), embarrassment (50.0%), and mood swings (45.0%). Most commonly reported work/productivity concepts included reduced concentration (77.5%) and reduced productivity (67.5%). Most participants reported improvements since taking the study medication (mood: ≥ 82.4%; work/productivity: ≥ 80.0%), which contributed to other positive changes (e.g., in social wellbeing). Improvements were considered meaningful (≥ 72.2%) and highly satisfying (≥ 71.4%). Conclusion This study provides novel insights into women’s experiences of VMS-associated impacts on mood and work/productivity, highlighting the emotional and economic burdens of VMS. Data support and contextualize the treatment benefits of elinzanetant on mood and work/productivity that are meaningful to women.
- 12 July 2025
- Published by Springer Nature in The Patient - Patient-Centered Outcomes Research
- Vol. 18 (6) , 687-697
Open AccessExit Interviews Examining Changes to Mood and Work/Productivity Impacts Related to Vasomotor Symptoms: Perspectives of Postmenopausal Women Receiving Elinzanetant in Phase III Clinical Trials
Background Vasomotor symptoms (VMS; hot flashes) significantly impact women’s health-related quality of life during the menopausal transition. Two phase III trials (OASIS 1 and 2) were conducted to investigate the efficacy and safety of elinzanetant for the treatment of moderate-to-severe VMS associated with menopause. This exit interview study explored the impact of VMS on women’s mood and work/productivity before and since treatment. Methods A total of 40 postmenopausal women from the USA who participated in OASIS 1 and 2 (receiving elinzanetant for 26 weeks or placebo for 12 weeks followed by elinzanetant for 14 weeks) took part in a 60-min exit interview. Interviews were conducted via telephone by trained qualitative interviewers using a semi-structured interview guide; concept-elicitation techniques, followed by focused questioning, were used to explore concepts of interest. Interview transcripts were analyzed using thematic analysis methods in Atlas.ti. Saturation analysis was conducted to determine the appropriateness of the sample size. Results Twelve mood concepts and seven work/productivity concepts were reported to be associated with VMS before taking the study medication. Most commonly reported mood concepts included reduced happiness (60.0%), embarrassment (50.0%), and mood swings (45.0%). Most commonly reported work/productivity concepts included reduced concentration (77.5%) and reduced productivity (67.5%). Most participants reported improvements since taking the study medication (mood: ≥ 82.4%; work/productivity: ≥ 80.0%), which contributed to other positive changes (e.g., in social wellbeing). Improvements were considered meaningful (≥ 72.2%) and highly satisfying (≥ 71.4%). Conclusion This study provides novel insights into women’s experiences of VMS-associated impacts on mood and work/productivity, highlighting the emotional and economic burdens of VMS. Data support and contextualize the treatment benefits of elinzanetant on mood and work/productivity that are meaningful to women.
- Open Access
- 11 June 2025
- Published by Springer Nature in Journal of Patient-Reported Outcomes
- Vol. 9 (1) , 1-15
Psychometric validation of the severity of chronic cough diary, leicester cough questionnaire, and a cough severity visual analogue scale in patients with refractory chronic cough
Background: Refractory chronic cough (RCC) is commonly reported in primary care and associated with significant morbidity. Patient-reported outcome (PRO) measures are important for evaluating the efficacy of antitussive medications for RCC in clinical trials from the patient-perspective. Psychometric properties of Severity of Chronic Cough Diary (SCCD) Cough Severity and Cough Frequency, Leicester Cough Questionnaire (LCQ) Total and Physical Domain and Cough Severity Visual Analogue Scale (VAS) scores using data from a 12-week Phase 2b trial evaluating the efficacy of eliapixant in patients with RCC (NCT04562155) are reported. Results: Quality of completion for the SCCD, LCQ and Cough Severity VAS across the study was high, no ceiling or floor effects were observed at baseline. Internal consistency for LCQ Total and Physical domain scores was also high (Cronbach’s alpha = 0.939 and 0.806, respectively). SCCD Cough Frequency and Cough Severity, LCQ Total and Physical domain, and Cough Severity VAS scores demonstrated strong test-retest reliability (Intraclass correlation coefficient ≥ 0.848) among participants defined as stable between Week 3 and Week 4 according to Patient Global Impression of Severity (PGI-S) ratings and Awake Cough Count readings. Construct validity was supported by known-groups comparisons, with large differences (effect sizes 1.99–4.16) observed between groups categorized according to PGI-S ratings and objective Awake Cough Counts. Ability to detect improvement was supported by large effect sizes (≥0.8) observed for mean changes in SCCD, LCQ and Cough Severity VAS scores from baseline to Week 12 among participants classified as ‘improved’ according to PGI-S/PGI-C ratings and Awake Cough Counts. Triangulated thresholds (score range) for meaningful within-patient improvement based on anchor-based assessments were -0.82 for SCCD Cough Frequency (0–4), -0.69 for SCCD Cough Severity (0–4), 2.36 for the LCQ Total (3–21), 0.77 for the LCQ Physical (1–7) and -17.73 for the Cough Severity VAS (0–100) scores. Conclusion: Findings support the reliability, validity and responsiveness of the newly developed SCCD Cough Frequency and Severity items as fit-for-purpose PRO measures of cough frequency or severity for use in drug development programs within RCC. The LCQ Total, LCQ Physical Domain and Cough Severity VAS also exhibit acceptable measurement properties for use in this population.
- 11 June 2025
- Published by Springer Nature in Journal of Patient-Reported Outcomes
- Vol. 9 (1) , 1-15
Open AccessPsychometric validation of the severity of chronic cough diary, leicester cough questionnaire, and a cough severity visual analogue scale in patients with refractory chronic cough
Background: Refractory chronic cough (RCC) is commonly reported in primary care and associated with significant morbidity. Patient-reported outcome (PRO) measures are important for evaluating the efficacy of antitussive medications for RCC in clinical trials from the patient-perspective. Psychometric properties of Severity of Chronic Cough Diary (SCCD) Cough Severity and Cough Frequency, Leicester Cough Questionnaire (LCQ) Total and Physical Domain and Cough Severity Visual Analogue Scale (VAS) scores using data from a 12-week Phase 2b trial evaluating the efficacy of eliapixant in patients with RCC (NCT04562155) are reported. Results: Quality of completion for the SCCD, LCQ and Cough Severity VAS across the study was high, no ceiling or floor effects were observed at baseline. Internal consistency for LCQ Total and Physical domain scores was also high (Cronbach’s alpha = 0.939 and 0.806, respectively). SCCD Cough Frequency and Cough Severity, LCQ Total and Physical domain, and Cough Severity VAS scores demonstrated strong test-retest reliability (Intraclass correlation coefficient ≥ 0.848) among participants defined as stable between Week 3 and Week 4 according to Patient Global Impression of Severity (PGI-S) ratings and Awake Cough Count readings. Construct validity was supported by known-groups comparisons, with large differences (effect sizes 1.99–4.16) observed between groups categorized according to PGI-S ratings and objective Awake Cough Counts. Ability to detect improvement was supported by large effect sizes (≥0.8) observed for mean changes in SCCD, LCQ and Cough Severity VAS scores from baseline to Week 12 among participants classified as ‘improved’ according to PGI-S/PGI-C ratings and Awake Cough Counts. Triangulated thresholds (score range) for meaningful within-patient improvement based on anchor-based assessments were -0.82 for SCCD Cough Frequency (0–4), -0.69 for SCCD Cough Severity (0–4), 2.36 for the LCQ Total (3–21), 0.77 for the LCQ Physical (1–7) and -17.73 for the Cough Severity VAS (0–100) scores. Conclusion: Findings support the reliability, validity and responsiveness of the newly developed SCCD Cough Frequency and Severity items as fit-for-purpose PRO measures of cough frequency or severity for use in drug development programs within RCC. The LCQ Total, LCQ Physical Domain and Cough Severity VAS also exhibit acceptable measurement properties for use in this population.
- Open Access
- 7 May 2025
- Published by Springer Nature in Journal of Patient-Reported Outcomes
- Vol. 9 (1) , 1-17
Psychometric evaluation of the HFDD, PROMIS SD SF 8b, and MENQOL questionnaire in women experiencing vasomotor symptoms associated with menopause
Background: Vasomotor symptoms (VMS; hot flashes) associated with menopause have significant impacts on health-related quality of life and are a leading cause for women seeking medical attention. Patient-reported outcome (PRO) instruments are commonly used to assess treatment benefit in VMS clinical trials and must demonstrate supportive evidence of measurement properties within the context of use. This study evaluated the measurement properties of scores from the Hot Flash Daily Diary (HFDD), PROMIS Sleep Disturbance Short Form 8b (PROMIS SD SF 8b) and Menopause-Specific Quality of Life (MENQOL) for measuring treatment efficacy in VMS clinical trials. Methods: Measurement properties of the HFDD, PROMIS SD SF 8b, and MENQOL scores were assessed using data (n = 400 participants) from a randomized, placebo-controlled, phase 3 study evaluating the efficacy and safety of elinzanetant for the treatment of VMS in postmenopausal women (OASIS 2). Analyses assessed distributional properties, reliability, validity, responsiveness, and thresholds for meaningful change. Results: Minimal floor and ceiling effects were found across the instruments at baseline. Inter-item correlations, and confirmatory factor analysis or item-response theory supported dimensionality and scoring for the MENQOL and PROMIS SD SF 8b, respectively. Test-retest reliability between Weeks 8 and 12 was good to excellent for HFDD Frequency and Severity of moderate-to-severe hot flashes scores, PROMIS SD SF 8b T-score and MENQOL Total score (intra-class correlation coefficients 0.835–0.971). Convergent and divergent correlations with instruments assessing similar or distinct constructs were consistent with pre-specified hypotheses. Known-groups validity was supported by significant differences (p < 0.0001) between subgroups hypothesized a priori as being clinically distinct. Responsiveness was indicated by consistent and statistically significant differences (p < 0.0001) in mean changes from baseline to Week 4 and 12 between groups of participants classified as ‘improved’, ‘stable’ and ‘worsened’ (effect sizes for improvement 0.81–4.62). Triangulation of estimates from multiple anchor-based analyses derived meaningful within-individual change thresholds for the HFDD, PROMIS SD SF 8b and MENQOL scores that were likely to exceed measurement error. Conclusions: Findings provide evidence that HFDD, PROMIS SD SF 8b, and MENQOL scores are valid, reliable and responsive to change, supporting their use for assessing key efficacy endpoints in VMS clinical trials.
- 7 May 2025
- Published by Springer Nature in Journal of Patient-Reported Outcomes
- Vol. 9 (1) , 1-17
Open AccessPsychometric evaluation of the HFDD, PROMIS SD SF 8b, and MENQOL questionnaire in women experiencing vasomotor symptoms associated with menopause
Background: Vasomotor symptoms (VMS; hot flashes) associated with menopause have significant impacts on health-related quality of life and are a leading cause for women seeking medical attention. Patient-reported outcome (PRO) instruments are commonly used to assess treatment benefit in VMS clinical trials and must demonstrate supportive evidence of measurement properties within the context of use. This study evaluated the measurement properties of scores from the Hot Flash Daily Diary (HFDD), PROMIS Sleep Disturbance Short Form 8b (PROMIS SD SF 8b) and Menopause-Specific Quality of Life (MENQOL) for measuring treatment efficacy in VMS clinical trials. Methods: Measurement properties of the HFDD, PROMIS SD SF 8b, and MENQOL scores were assessed using data (n = 400 participants) from a randomized, placebo-controlled, phase 3 study evaluating the efficacy and safety of elinzanetant for the treatment of VMS in postmenopausal women (OASIS 2). Analyses assessed distributional properties, reliability, validity, responsiveness, and thresholds for meaningful change. Results: Minimal floor and ceiling effects were found across the instruments at baseline. Inter-item correlations, and confirmatory factor analysis or item-response theory supported dimensionality and scoring for the MENQOL and PROMIS SD SF 8b, respectively. Test-retest reliability between Weeks 8 and 12 was good to excellent for HFDD Frequency and Severity of moderate-to-severe hot flashes scores, PROMIS SD SF 8b T-score and MENQOL Total score (intra-class correlation coefficients 0.835–0.971). Convergent and divergent correlations with instruments assessing similar or distinct constructs were consistent with pre-specified hypotheses. Known-groups validity was supported by significant differences (p < 0.0001) between subgroups hypothesized a priori as being clinically distinct. Responsiveness was indicated by consistent and statistically significant differences (p < 0.0001) in mean changes from baseline to Week 4 and 12 between groups of participants classified as ‘improved’, ‘stable’ and ‘worsened’ (effect sizes for improvement 0.81–4.62). Triangulation of estimates from multiple anchor-based analyses derived meaningful within-individual change thresholds for the HFDD, PROMIS SD SF 8b and MENQOL scores that were likely to exceed measurement error. Conclusions: Findings provide evidence that HFDD, PROMIS SD SF 8b, and MENQOL scores are valid, reliable and responsive to change, supporting their use for assessing key efficacy endpoints in VMS clinical trials.
- Open Access
- 17 February 2025
- Published by Springer Nature in Journal of Patient-Reported Outcomes
- Vol. 9 (1) , 1-8
Comparative performance of PROMIS Sleep Disturbance computerized adaptive testing algorithms and static short form in postmenopausal women
Background: The Patient-Reported Outcomes Measurement Information System (PROMIS) Sleep Disturbance v1.0 item bank (27 items) measures sleep disturbances. Rather than the full item bank, an 8-item short form (PROMIS SD SF 8b) or computerized adaptive testing (CAT) can be used. This study compares the performance of the PROMIS SD SF 8b with two CAT algorithms in postmenopausal women. Methods: This is a secondary analysis of data collected for the original psychometric testing of the PROMIS Sleep Disturbance item bank, in a sub-sample of women aged ≥55. A graded response model (GRM) was fitted for the item bank, then simulations evaluated the performance of CAT algorithms and the short form, in terms of root mean square error (RMSE) versus the latent trait estimate derived from the full bank. Two CAT algorithms were tested: CAT1 (stop once standard error p < 0.001 for all). Conclusions: The results of this study support using the PROMIS Sleep Disturbance item bank in postmenopausal women. The choice of PROMIS SD SF 8b versus CAT can largely be driven by practical reasons (respondent burden and operational complexity) rather than concerns of differential reliability and validity.
- 17 February 2025
- Published by Springer Nature in Journal of Patient-Reported Outcomes
- Vol. 9 (1) , 1-8
Open AccessComparative performance of PROMIS Sleep Disturbance computerized adaptive testing algorithms and static short form in postmenopausal women
Background: The Patient-Reported Outcomes Measurement Information System (PROMIS) Sleep Disturbance v1.0 item bank (27 items) measures sleep disturbances. Rather than the full item bank, an 8-item short form (PROMIS SD SF 8b) or computerized adaptive testing (CAT) can be used. This study compares the performance of the PROMIS SD SF 8b with two CAT algorithms in postmenopausal women. Methods: This is a secondary analysis of data collected for the original psychometric testing of the PROMIS Sleep Disturbance item bank, in a sub-sample of women aged ≥55. A graded response model (GRM) was fitted for the item bank, then simulations evaluated the performance of CAT algorithms and the short form, in terms of root mean square error (RMSE) versus the latent trait estimate derived from the full bank. Two CAT algorithms were tested: CAT1 (stop once standard error p < 0.001 for all). Conclusions: The results of this study support using the PROMIS Sleep Disturbance item bank in postmenopausal women. The choice of PROMIS SD SF 8b versus CAT can largely be driven by practical reasons (respondent burden and operational complexity) rather than concerns of differential reliability and validity.
- 9 October 2024
- Published by Springer Nature in Quality of Life Research
- Vol. 34 (1) , 151-160
Conceptualizing meaningful between-group difference in change over time: a demonstration of possible viewpoints
Purpose Determining if group-level differences in health outcomes are meaningful has recently been neglected in favour of determining if individuals have experienced a meaningful change. We explore interpretation of a meaningful between-group difference (MBGD) in clinical outcome assessment scores, primarily in the context of randomized clinical trials. Methods We constructed a series of possible ‘viewpoints’ on how to conceptualize MBGD thresholds. Each viewpoint is discussed critically in terms of potential advantages and disadvantages, with simulated data to facilitate their consideration. Results Five viewpoints are presented and discussed. The first considers whether thresholds for meaningful within-individual change over time can be equally applied at the group-level, which is shown to be untenable. Viewpoints 2-4 consider what would have to be observed in treatment groups to conclude a meaningful between-group difference has occurred, framed in terms of the proportion of patients perceiving that they had meaningfully improved. The final viewpoint considers an alternative framework where stakeholders are directly questioned on the meaningfulness of varying magnitudes of between-group differences. The choice of a single threshold versus general interpretative guidelines is discussed. Conclusion There does not appear to be a single method with clear face validity for determining MBGD thresholds. Additionally, the notion that such thresholds can be purely data-driven is challenged, where a degree of subjective stakeholder judgement is likely required. Areas for future research are proposed, to move towards robust method development.
- 9 October 2024
- Published by Springer Nature in Quality of Life Research
- Vol. 34 (1) , 151-160
Conceptualizing meaningful between-group difference in change over time: a demonstration of possible viewpoints
Purpose Determining if group-level differences in health outcomes are meaningful has recently been neglected in favour of determining if individuals have experienced a meaningful change. We explore interpretation of a meaningful between-group difference (MBGD) in clinical outcome assessment scores, primarily in the context of randomized clinical trials. Methods We constructed a series of possible ‘viewpoints’ on how to conceptualize MBGD thresholds. Each viewpoint is discussed critically in terms of potential advantages and disadvantages, with simulated data to facilitate their consideration. Results Five viewpoints are presented and discussed. The first considers whether thresholds for meaningful within-individual change over time can be equally applied at the group-level, which is shown to be untenable. Viewpoints 2-4 consider what would have to be observed in treatment groups to conclude a meaningful between-group difference has occurred, framed in terms of the proportion of patients perceiving that they had meaningfully improved. The final viewpoint considers an alternative framework where stakeholders are directly questioned on the meaningfulness of varying magnitudes of between-group differences. The choice of a single threshold versus general interpretative guidelines is discussed. Conclusion There does not appear to be a single method with clear face validity for determining MBGD thresholds. Additionally, the notion that such thresholds can be purely data-driven is challenged, where a degree of subjective stakeholder judgement is likely required. Areas for future research are proposed, to move towards robust method development.
- Open Access
- 22 August 2024
- Published by Springer Nature in Quality of Life Research
- Vol. 33 (11) , 2963-2973
Effect of present state bias on minimal important change estimates: a simulation study
Purpose: The minimal important change (MIC) in a patient-reported outcome measure is often estimated using patient-reported transition ratings as anchor. However, transition ratings are often more heavily weighted by the follow-up state than by the baseline state, a phenomenon known as “present state bias” (PSB). It is unknown if and how PSB affects the estimation of MICs using various methods. Methods: We simulated 3240 samples in which the true MIC was simulated as the mean of individual MICs, and PSB was created by basing transition ratings on a “weighted change”, differentially weighting baseline and follow-up states. In each sample we estimated MICs based on the following methods: mean change (MC), receiver operating characteristic (ROC) analysis, predictive modeling (PM), adjusted predictive modeling (APM), longitudinal item response theory (LIRT), and longitudinal confirmatory factor analysis (LCFA). The latter two MICs were estimated with and without constraints on the transition item slope parameters (LIRT) or factor loadings (LCFA). Results: PSB did not affect MIC estimates based on MC, ROC, and PM but these methods were biased by other factors. PSB caused imprecision in the MIC estimates based on APM, LIRT and LCFA with constraints, if the degree of PSB was substantial. However, the unconstrained LIRT- and LCFA-based MICs recovered the true MIC without bias and with high precision, independent of the degree of PSB. Conclusion: We recommend the unconstrained LIRT- and LCFA-based MIC methods to estimate anchor-based MICs, irrespective of the degree of PSB. The APM-method is a feasible alternative if PSB is limited.
- 22 August 2024
- Published by Springer Nature in Quality of Life Research
- Vol. 33 (11) , 2963-2973
Open AccessEffect of present state bias on minimal important change estimates: a simulation study
Purpose: The minimal important change (MIC) in a patient-reported outcome measure is often estimated using patient-reported transition ratings as anchor. However, transition ratings are often more heavily weighted by the follow-up state than by the baseline state, a phenomenon known as “present state bias” (PSB). It is unknown if and how PSB affects the estimation of MICs using various methods. Methods: We simulated 3240 samples in which the true MIC was simulated as the mean of individual MICs, and PSB was created by basing transition ratings on a “weighted change”, differentially weighting baseline and follow-up states. In each sample we estimated MICs based on the following methods: mean change (MC), receiver operating characteristic (ROC) analysis, predictive modeling (PM), adjusted predictive modeling (APM), longitudinal item response theory (LIRT), and longitudinal confirmatory factor analysis (LCFA). The latter two MICs were estimated with and without constraints on the transition item slope parameters (LIRT) or factor loadings (LCFA). Results: PSB did not affect MIC estimates based on MC, ROC, and PM but these methods were biased by other factors. PSB caused imprecision in the MIC estimates based on APM, LIRT and LCFA with constraints, if the degree of PSB was substantial. However, the unconstrained LIRT- and LCFA-based MICs recovered the true MIC without bias and with high precision, independent of the degree of PSB. Conclusion: We recommend the unconstrained LIRT- and LCFA-based MIC methods to estimate anchor-based MICs, irrespective of the degree of PSB. The APM-method is a feasible alternative if PSB is limited.
- 27 December 2023
- Published by Springer Nature in Quality of Life Research
- Vol. 33 (4) , 963-973
Estimating anchor-based minimal important change using longitudinal confirmatory factor analysis
Purpose The minimal important change (MIC) is defined as the smallest within-individual change in a patient-reported outcome measure (PROM) that patients on average perceive as important. We describe a method to estimate this value based on longitudinal confirmatory factor analysis (LCFA). The method is evaluated and compared with a recently published method based on longitudinal item response theory (LIRT) in simulated and real data. We also examined the effect of sample size on bias and precision of the estimate. Methods We simulated 108 samples with various characteristics in which the true MIC was simulated as the mean of individual MICs, and estimated MICs based on LCFA and LIRT. Additionally, both MICs were estimated in existing PROMIS Pain Behavior data from 909 patients. In another set of 3888 simulated samples with sample sizes of 125, 250, 500, and 1000, we estimated LCFA-based MICs. Results The MIC was equally well recovered with the LCFA-method as using the LIRT-method, but the LCFA analyses were more than 50 times faster. In the Pain Behavior data (with higher scores indicating more pain behavior), an LCFA-based MIC for improvement was estimated to be 2.85 points (on a simple sum scale ranging 14–42), whereas the LIRT-based MIC was estimated to be 2.60. The sample size simulations showed that smaller sample sizes decreased the precision of the LCFA-based MIC and increased the risk of model non-convergence. Conclusion The MIC can accurately be estimated using LCFA, but sample sizes need to be preferably greater than 125.
- 27 December 2023
- Published by Springer Nature in Quality of Life Research
- Vol. 33 (4) , 963-973
Estimating anchor-based minimal important change using longitudinal confirmatory factor analysis
Purpose The minimal important change (MIC) is defined as the smallest within-individual change in a patient-reported outcome measure (PROM) that patients on average perceive as important. We describe a method to estimate this value based on longitudinal confirmatory factor analysis (LCFA). The method is evaluated and compared with a recently published method based on longitudinal item response theory (LIRT) in simulated and real data. We also examined the effect of sample size on bias and precision of the estimate. Methods We simulated 108 samples with various characteristics in which the true MIC was simulated as the mean of individual MICs, and estimated MICs based on LCFA and LIRT. Additionally, both MICs were estimated in existing PROMIS Pain Behavior data from 909 patients. In another set of 3888 simulated samples with sample sizes of 125, 250, 500, and 1000, we estimated LCFA-based MICs. Results The MIC was equally well recovered with the LCFA-method as using the LIRT-method, but the LCFA analyses were more than 50 times faster. In the Pain Behavior data (with higher scores indicating more pain behavior), an LCFA-based MIC for improvement was estimated to be 2.85 points (on a simple sum scale ranging 14–42), whereas the LIRT-based MIC was estimated to be 2.60. The sample size simulations showed that smaller sample sizes decreased the precision of the LCFA-based MIC and increased the risk of model non-convergence. Conclusion The MIC can accurately be estimated using LCFA, but sample sizes need to be preferably greater than 125.